HomeMy WebLinkAboutFile Documents.716 E Hopkins Ave.0064-2022-BRES (12) REFERENCES FROM 2015 IRC Field Plan Set Must Be Printed In Color �1 � CV/A=crawl space ventilation required,sec.R408.1 Access required,R408.4 ;`' '/ APPLICATION ACCEPTED DATE: 2022-05-24 PERMIT NUMBER: 0064-2022-BRES EE=emergency escape required sec R310.1 EU=enclosed usable space under stairs shall be'/z"Gyp,sec R302.7 �',i,I G/D=garage/dwelling separation,sec R302.5 and R302.6 STC=Sound transmission class not less than 45 at dwelling separations,app K CITY OF ASPEN RV=roof and rafter ventilation required,R806.1 CITY OF A=attic access 22"x 30",30"headroom above,R807.1 A C B�C COMMUNITY DEVELOPMENT DEPARTMENT SA=smoke alarms installed to NFPA 72 requirements,sec R314 ASPS CO=carbon monoxide detector per City Ordinance 41 series 2008 PERMIT NO 0064-2022-BRES o,',�p SG=safety glazing required,sec R308.4 ■ _ GR=guardrails,36"min ht,4"max opening;req at 30"drop any point w/in 36" BUILDING PERMIT COVERSHEET i�• horizontally,sec R312 These plans muus eKeept at the N WFP=window fall protection-operable window<24"AFF&>72"above OWNER CITY OF ASPEN grade:use opening control device listed to ASTM F2090,sec R312.2 Goldberg Aspen Family QPRT building site or inspection HR=handrails 34"-38"ht,sec R311.7.8 . .- -- delays may occur.Construction SI=stairway illumination,sec R303.7 shall conform to these plans.All PD=protect against decay,sec R317 ADDRESS PROPERTY INFORMATION REFERENCES FROM 20151MC 716 E.Hopkins changes shall be approved by V=bathroom and balanced whole house mechanical ventilation req. - - - - Ifiliging official. Ordinance 40,2016 ADDRESS: 716 E HOPKINS AVE UNIT: DE=clothes dryer exhaust,sec504.Makeup air req'd if over 200 CFM PARCEL ID AS=access and service space for maintenance req'd,sec 306 273707334005 PARCEL ID: 273707334005 LEGAL DESCRIPTION: PITKIN ROW MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2 SEPARATE PERMITS ARE OWNER: GOLDBERG ASPEN FAMILY QPRT ET=exhausts terminate 3'from prop line and openings,10'from intakes, - 501.3.1 REQUIRED FOR ELECTRICAL, PERMIT CONTRACTOR: SH BUILDING GROUP LLC IT=intake openings 10'from lot line&contaminant sources(vents,streets), PLUMBING,MECHANICAL,OR 401.4 FIRE SPRINKLER WORK D=fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC DV=direct vent req'd,sec 303.3 SMOKE ALARMS AND CA=combustion air not taken from bedrooms,bathrooms or CARBON MONOXIDE DESCRIPTION OF WORK Interior remodel includinupdating finishesthrou hout,reconfi urationofkitchen,u updating bathrooms andsuomgeapciance DETECTORS REQUIRED p g g g p g OD=outdoor appliances must be listed for outdoor use,sec 303.6 THROUGHOUT DWELLING fire laces,redesign/replacement ofu er level stairs and railin s,replacement of existingheat mat, REFERENCES FROM 2015 IECC ppp g p F=new or replacement glazing shall not exceed 0.28 U-Value,NFRC label Prescriptive Energy Requirements UNIT PER CITY OF ASPEN replacement of lighting with min 90%efficacy for permanentlyi nstalled lighting,addition of sprinklers required,Ordinance40,2016 MUNICIPAL CODE 8.15 L=75%of lamps in permanently installed lights must be high efficacy,sec R404.1 j. Table R402.1.2"Insulation and Insulation and Fenestration Requirements by Component"has SE=Continuous air barrier required;all exterior joints,cracks,and holes to be been amended as follows: R-value caulked,gasketed,sealed,table R402.4.1.1 _ REFERENCES FROM 2014 NEC Fenestration Skylight Glazed Ceiling Wood Mass Wall Floor Basement Slab Crawl- EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 I It should be known that this review shall U-Factor U-Factor Fenestration R-Value Frame R-Value(i) R-Value Wall R-Value& space Wall not relieve the applicant of their USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes (b) (b) SHGC(b) Wall R-Value Depth(d) R-Value responsibility to comply with the (e) R-Value _ (c) (c) requirements of the City of Aspen 0.28 0.55 NR 49 20+5 or 19/21 38(g) 15/19 10,4ft 15/19 Municipal Code.Pursuant to 13+10(h) Sec.26.104.050,any permit or approval CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 R OR issued in error rwise not in conformity with thee r requiequirements of this k. Table R402.1.4"Equivalent U-Factors"has been amended as follows: Title,shall be void.Similarly,any permit U-factor or approval issued in reliance upon or REQUIRED SPECIAL GLASS IN GUARDS AND HANDRAILS as a result of,a materially false BUILDING TYPE(IRC) Two family Glass in guards and handrails shall be two plies equal thickness Fenestration Skylight Ceding Frame Mass Wall Floor Basement Crawl- statement or representation made in INSPECTIONS laminated glass. Tempered glass is only permitted where not U-Factor U-Factor U-Factor Wall U- U-Factor U-Factor Wall space Wall the process of obtaining the permit or above a walking surface and when a top rail that is either Factor (b) U-Factor U-Factor development approval shall,likewise, self-supported(glass infill panels)or is supported by a minimum of II 0.28 0.55 0.026 0.045 0.057 0.028 0.050 0.055 be void.Any person having received a CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE Prescriptive Ta ble three panes of glass. IRC 308.7/IBC 2407. void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall OCCUPANCY GROUP(IBC) R-3 WORK CHANGES BUILDING No not be estoppel frome fully enforcing FOOTPRINT? CODE EDITIONS 2015 I RC TOTAL SPA SQ.FT. EVOLVE No exterior lighting in scope of work.No changes to exterior or party wall penetrations in scope of work.No changes STRUCTURAL DESIGN 1040 MAIN STREET•CARBONDALE.CO81623•19701510-0773 wrnvevolvesvuacvn to exterior mechanical equipment in scope 75%of lamps in permanently Recessed luminaires installed of work. OTHER CODE EDITIONS 2015 I EBC,2015 I FCC,2020 NEC TOTAL SNOWMELT SOFT. installed light fixtures shall be in building thermal envelope March 30,2022 high efficacy-IECC R404.1 shall be sealed and IC-rated ty�q���.d��p�/r•^o�'ry{-IECC sec R402.4.5 re067:3311/12722yy�6L1�lYR\rip Q�Dylan M.Johns,Principal 1:UtL/t "`���^^^[U1Zone 4 Architects HISTORIC PROPERTY? No TOTAL POOL SQ.FT. 432 E Hyman Ave Aspen,Colorado 81611 ZONING djohns@zone4architects.com RE: 716 E Hopkins Avenue Remodel FIRE SPRINKLER EXISTING? No Asp Aspen, Colorado 81611 D g[ a WIE"") Double Wood Stud 1 hour fire,SIC 55 assembly from the Gypsum Manual(GA-600 Fire Resistance Desil Dylan, { Manual): 11 GA FILE NO.WP 3370 I I GENERIC I I 1 HOUR II 45 to 49 SIC We understand the proposed remodel is primarily an interior remodel to an existing residence.The remodel includes 0 /0 OO/r1 O r1 r1 FIRE SOUND revising several interior wall locations and updating the stairway. 7 G G G GYPSUM WALLBOARD.WOOD STUDS ono layer sr:rypaxavm,c wanmam«gn,,,m vanes,mse applied par.waursru Once demolition can begin,the wall and ceiling finishes in the relevant areas shall be at least partially removed in Mlf'li:.f•/tiii'.1 urges w 6ch sae a daft.row or 2 a 4 wood studs 16,o c.on separate gees r �M78P fJN551r span meth 6d mated nabs.m:long.00915'shank.Oi%ads.r o.c. 'y order to verify the existing structure.We shall be contacted to visually observe the conditions and will then work to Janes staggered 16.on opposite.%eonzoniu weans rammed at,me-neighs(LOAD. - .7 define the structural impact of the proposed remodel.This shall be done prior to proceeding with the removal or 1 imp BEARING) modification of any framing members,while also allowing sufficient time for the scope of structural engineering to be Wall assembly on top floor behind fireplace. defined and completed.Please note,no interior partition walls nor ceiling framing shall be removed or modified prior ( 1 to our observation. CONDITIONS OBSERVED @ 708 E HOPKINS BEHING LR FIREPLACE Thickness: svr The structural modification to walls will require an analysis of both the gravity and lateral systems of the affected oevv,.waghc 6 psi structural elements.The analysis will trace the gravity and lateral loads paths through the building,possibly affecting Fere Test. SeewP3605 (UL R13104.6.6-17-52: and requiring structural work in areas of the building outside of the proposed architectural scope and could have an GA FILE NO.WP 3242 GENERIC I 1 HOUR 50 to 54 STC UL Peden3g.1-zaa16; impact on the project direction and schedule. UL R3501-52.Y1546. UL Design Design wg GYPSUM WALLBOARD,RESILIENT CHANNELS, FIRE SOUND utcauv ,0.301k Shouldyou have anyfurtherquestions regarding this matter,please feel free to contact our office.We look forward UL R4e24, W3011 B B MINERAL OR GLASS FIBER INSULATION,WOOD STUDS fw sound Test 5Rcc TL-93-261. to working with you through the completion of your remodel. Resilient channels 16"o.c.attached at right angles to ONE SIDE of 2 x 4 wood studs 16" ' Ty '�".,�' iec ie 161 area 1910 or 24"o.c.with 1 Va"Type S drywall screws.One layer 5/s"type X gypsum wallboard or �Morni.omre or Noise coova O Sincerely, veneer base applied at ri ht angles to channels with 1"T e S drywall screws " rI P e.ee.a. 57C s.mbe gypsum9 9 Type rYv+ / 1 \ /' Test Number Seal.r 8"o.c.with vertical joints located midway between studs End joints backblocked with Sk.1tk Bdrf Dmerlpflon t an..,Teem. Evolve Structural Design LLC resilient channels.3"mineral or glass fiber insulation in stud space. 8.7S1MaraMm� R.S1Ol4G�ti1 Some.6 Dala Tee OPPOSITE SIDE:One layer 5/i't e Xgypsum wallboard orgypsum veneer base applied �wwws,� Y type 0P Approx.Wei ht 7a/sf 1. x 3 Jew.Ms%�WM. rMeurt6 ewe.on ... F,1 aerslas os ss t2ai.: =-�PN00 L�CF��t at parallel or at right angles to studs with 6d cement coated nails,1z/e"long,applie" shank,15/1e"heads,7"o.c. Fire Test g Based on UL R14196, --- ---- 1.1/1./type Kk puns board oard=cuednuation Mee. 59 W.1549 1'VO a p,fo••5��1 Vertical joints staggered 24"on opposite sides.Sound tested with studs spaced 24"o.c. OSNK05371,2-15-05, ,-I 1st •'S� N�, i P Ytype UL Designoven✓cormar :F -a. y (STC=50).Also sound tested with studs spaced 16"o.c.and with two layers of 24 ,2-1 riOerW, :u, 51A35 °t X gypsum board on the resilient channel side(STC=50).(LOAD-BEARING) Sound Test: NRCC TL93-103,3-98 L �1 :••�&..�� t z1 5 NRCC TL93-118,3-98 - •• - - --- �,-$�S,, 7 jW. 14, /0NALEr=_ 03/30/2022 W7 - PARTY WALL REFERENCE n W1 - PARTY WALL ASSEMBLY Steven R.Edmiston,P.E.,S.E. RECEIVED 1 Principal D ouro,/0022 05/23/2022 FOROMSUAa'IWCE ASPEN BUILDING DEPARTMENT