HomeMy WebLinkAboutFile Documents.128 Park Ave.0077-2023-BRES (4) IAPPLICATION ACCEPTED DATE: 2023-05-23 PERMIT NUMBER: 0077-2023-BRES Field Plan Set Must Be Printed In Color �`1��/�
COMMUNITY DEVELOPMENT DEPARTMENT ITY 14EN �� ��
c o r
BUILDING PERMIT COVERSHEET
til��� CITY OF
CITY OF ASPEN� PERMIT NO. o977-2o23-BRs. • ASPEN
PROPERTY INFORMATION These plans muffs eKeept at the
building site or inspection
OWNER delays may ocou plans.All
ADDRESS: 128 PARK AVE UNIT: Silver Lake Family Trust shall conform to these plans.All
PARCEL ID: 273718167001 LEGAL DESCRIPTION: ADAIR DUPLEX - +......m...+ ...F changes shall be approved by
OWNER: SILVER LAKE FAMILY TRUST 03/19/2015 lifiliging official.
PERMIT CONTRACTOR: ADDRESS
DDRES
128 Park Ave
SEPARATE PERMITS ARE
' REQUIRED FOR ELECTRICAL,
PLUMBING,MECHANICAL,OR
DESCRIPTION OF WORK New cabinets in all 4 bathrooms,new plumbing fixtures and solid surfaces.New tile flooring in all 4 bathrooms. FIRE SPRINKLER WORK
New cabinets,appliances and solid surfaces in 2 kitchens.re-finish wood flooring on upper level only.Re-paint Paô-r&IC E L ID 27371 81 67001
all areas. 3 SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
Dwelling Separation Required-2021 IBC UNIT PER CITY OF ASPEN
-708 Fire Partitions,711 Horizontal Assemblies: MUNICIPAL CODE 8.15
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? No rating of at least 1 hour.Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714:Penetrations must be protected by a through-penetration firestop I It should be known that this review shall
system.Recessed fixtures shall not reduce the required fire resistance by use not relieve the applicant of their
CLASS OF WORK Residential FIRE SPRINKLER TYPE of a listed fixture,a listed firehood,or a drywall assembly meeting the required
fire resistance.Exhaust fans require ceiling radiation damper. responsibility to comply with the
-1207 Sound Transmission:Separating walls and floor/ceilings shall have an RESIDENTIAL REFERENCES FROM 2015 IBC requirements of the City of Aspen
STC rating of at least 50.Floor/ceilings shall have an IIC rating of at least 50. CV/CS=crawl space ventilation sec.1203.4. 18"x 24"access required Municipal Code.Pursuant to
REQUIRED SPECIAL 1209.1 Sec.26.104.050,any permit or approval
BUILDING TYPE(IRC) Two family EE=emergency escape required sec 1030 issued in error or otherwise not in
INSPECTIONS EU=enclosed usable space under stairs shall be 1-hr construction or sta. conformity with the requirements of this
enclosure rating.No access from stair enclosure.Y."gypsum permitted fo
stairs inside a single dwelling unit.1011.7.3. Title,shall be void.Similarly,any permit
RV=roof and rafter ventilation required 1203.2 or approval issued in reliance upon or
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table A=Attic Access 20"x 30"1209.2 as a result of,a materially false
SA=smoke alarm(NFPA 72)required sec 907.2.11 statement or representation made in
CO=carbon monoxide detector req.per Aspen Municipal Code 8.15 the process of obtaining the permit or
SG=safety glazing required sec 2406
WORK CHANGES BUILDING V=mechanical ventilation required sec 1203.1&IMC 403(bath fans and development approval shall,likewise,
OCCUPANCY GROUP(IBC) R-2 No whole house ventilation) be void.Any person having received a
FOOTPRINT? GR=guards,42"min ht,4"max opening.Guards within dwelling unit 36"min void or voidable permit or approval
ExistingFireplaces and Woodstoves: ht sec 1015 shall not be relieved from having to
P HR=handrails 34"-38"ht sec 1014
-If you propose to alter the firebox of a fireplace or move a DS=Draft stopping/fire blocking 718 comply with all applicable terms and
CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT. fireplace,it shall be removed or replaced with a gas direct RD=Roof drainage 1503.4 conditions of this Title and the City shall
vent or electric appliance. STC=Sound transmission class not less than 50 at dwelling separations, not be estopped from fully enforcing
-Conversion to or replacement with gas log is prohibited. 1207
-New or replacement gas fireplaces are subject to REMP. same.
-If you propose to move or alter a woodstove,it shall be Si= protecty
Illuminationgitdecay,
y,1205.4c
PD=protect against decay,sec 23
removed or replaced with a department certified woodstove. REFERENCESES FROM 20151MC
OTHER CODE EDITIONS 2021IEBC,2021IPC,2020NEC TOTAL SNOWMELT SQ.FT. DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM
AS=access and service space for maintenance req'd,sec 306
MA=make up air required if hood exhausts greater than 400 CFM,sec 50 rgavieore i
100%of lamps in ET=exhausts terminate 3'from prop line and openings,10'from intakes,
HISTORIC PROPERTY? No TOTAL POOL SQ.FT. permanently installed light 501.3.1
fixtures must be high efficacy o=intake openings 10'from lot line&contaminant sources(vents,streets
119
-IECC R404.1 D=fasten and seal all ductwork per 603.9 06/22/2023
REFERENCES FROM 2015 IFGC �pr���
DV=direct vent req'd,sec 303.3 f'�7�lbr/r.la.
FIRE SPRINKLER EXISTING? No CA=combustion air not taken from bedrooms,bathrooms or
General Electrical Requirementssutdaorge apciance jimp
Q OD=outdoor appliances must be listed for outdoor use,sec 303.6
Any areas affected by the renovation must be brought REFERENCES FROM 2015 IECC
upto the current electrical code including: F=new or replacement fenestration shall not exceed 0.28 U-factor,NFRC
label required,Ordinance 40,2016
tamperproof receptacles(NEC 406.12), L=75%of lamps in permanently installed lights must be high efficacy,sec
ground-fault circuit interrupter protection(NEC 210.8), R404.1
arc-fault protection(NEC 210.12), SE=Continuous air barrier required;all exterior joints,cracks,and holes to be
caulked,gasketed,sealed,table R402.4.1.1
receptacle spacing(NEC 210.52)etc. REFERENCES FROM 2014 NEC
EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26