Loading...
HomeMy WebLinkAboutFile Documents.332 W Smuggler St.0115-2023-BROF (8) ESICC EVALUATION SERVICE' k it, I Tytit nv iS Compliance to International Codes • Compliance to State/Regional Codes www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® ICC-ES Evaluation Report Reissued October 2022 ESR-1463 Revised May 2023 This report is subject to renewal October 2023. DIVISION: 07 00 00—THERMAL AND MOISTURE 2.0 USES PROTECTION Carlisle ethylene propylene diene monomer (EPDM), Section: 07 53 23—Ethylene-Propylene-Diene-Monomer polyvinyl chloride(PVC)and thermoplastic polyolefin(TPO) Roofing single-ply roofing membranes are used as roof coverings in Section: 07 54 19—Polyvinyl-Chloride Roofing adhered and mechanically fastened membrane roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing systems. REPORT HOLDER: 3.0 DESCRIPTION CARLISLE SYNTEC SYSTEMS, A DIVISION OF 3.1 General: CARLISLE CONSTRUCTION MATERIALS, LLC The EPDM, PVC and TPO Membrane Roofing Systems EVALUATION SUBJECT: described in this report consist of single-ply roofing membranes, insulation where used, barrier board or slip CARLISLE EPDM, PVC AND TPO SINGLE-PLY sheet where used, flashing, mechanical fasteners and ROOFING MEMBRANES adhesives that are installed on a combustible or noncombustible deck.See Table 1 for Carlisle product trade ADDITIONAL LISTEES: names and corresponding product names for Mule-Hide MULE-HIDE PRODUCTS COMPANY, INC. Products Company, Inc., WeatherBond, Versico, and Roofing Products International, Inc.,the additional listees. VERSICO, A DIVISION OF CARLISLE CONSTRUCTION 3.2 EPDM Membranes: MATERIALS, LLC 3.2.1 Sure-Seal EPDM Membrane: Sure-Seal EPDM WEATHERBOND, A DIVISION OF CARLISLE Membrane is a black, nonreinforced EPDM membrane, CONSTRUCTION MATERIALS, LLC 45 mils thick[0.045 inch (1.14 mm)]. ROOFING PRODUCTS INTERNATIONAL, INC. 3.2.2 Sure-Seal FR EPDM Membrane: Sure-Seal FR EPDM Membrane is a black, nonreinforced EPDM 1.0 EVALUATION SCOPE membrane with fire retardants.Available thicknesses range from 45 mils (0.045 inch [1.14 mm]) to 90 mils (0.090 inch Compliance with the following codes: [2.29 mm]). • 2021, 2018, 2015, 2012 and 2009 International Building 3.2.3 Sure-White EPDM Membrane: Sure-White EPDM Code°(IBC) Membrane is a white, nonreinforced EPDM membrane. • 2021, 2018, 2015, 2012 and 2009 International Available in thicknesses of 60 mils [0.060 inch (1.52 mm)] Residential Code°(IRC) and 90 mils [0.090 inch (2.29 mm)]. • 2013 Abu Dhabi International Building Code(ADIBC)t 3.2.4 Sure-White Reinforced EPDM Membrane: Sure- White Reinforced EPDM Membrane is a white, reinforced The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced EPDM membrane. Available in a thickness of 60 mils in this report are the same sections in the ADIBC. [0.60 inch (1.52 mm). For evaluation for compliance with codes adopted by the Los Angeles Department of Building and Safety (LADBS), 3.2.5 Sure-Tough EPDM Membrane: Sure-Tough EPDM see ESR-1463 LABC and LARC Supplement. Membrane is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM Properties evaluated: membrane plies. Available in thicknesses ranging from • Weather resistance 45 mils [0.045 inch (1.14 mm)] to 75 mils [0.075 inch (1.90 mm)]. ■ Roof covering fire classification ■ Wind uplift resistance 3.2.6 Sure-Seal FleeceBACK EPDM Membrane: Sure- Seal FleeceBACK EPDM Membrane is a 45-mil to 90-mil • Impact resistance [0.045 inch to 0.090 inch (1.14 mm to 2.29 mm)] non- ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to he construed 69 as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright©2023 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 14 ESR-1463 I Most Widely Accepted and Trusted Page 2 of 14 reinforced EPDM bonded to a polyester fleece. Available Weld TPO Membrane specified in Section 3.4.1 for product thicknesses range from 100 mils [0.100 inch increased strength and weatherability. The membrane is (2.55 mm)]to 145 mils [0.145 inch (3.68 mm)]. available in white, gray, tan and custom colors.Available in 3.2.7 Sure-White FleeceBACK EPDM Membrane: Sure- a thickness of 80 mils(0.080 inch [2.03 mm]). White FleeceBACK EPDM Membrane is a 45-, 60-or 90-mil 3.4.3 Sure-Weld HS TPO Membrane:Sure-Weld HS TPO [0.045, 0.060 or 0.090 inch (1.14, 1.52 or 2.29 mm)] Membrane is the Sure-Weld membrane formulated with an nonreinforced white EPDM bonded to a polyester fleece. additional flame retardant for fire resistance at higher Available product thicknesses are 100, 115 and 145 mils slopes. The membrane is available in white, gray, tan and [0.100, 0.115 or 0.145 inch (2.54, 2.92 or 3.68 mm)]. custom colors.Available thicknesses are 45 mils(0.045 inch 3.2.8 Sure-Seal AFX EPDM Membrane: Sure-Seal AFX [1.14 mm])and 60 mils(0.060 inch [1.52 mm]). EPDM Membrane is a 45-mil [0.045 inch (1.14 mm) or 3.4.4 Sure-Weld SAT-TPO Membrane: Sure-Weld SAT- 60-mil[0.060 inch(1.52 mm)]non-reinforced EPDM bonded TPO Membrane is a self-adhered version of the Sure-Weld to a polyester fleece. Available thicknesses are 90 mils HS TPO membrane with adhesive. [0.090 inch(2.29 mm)]and 105 mils[0.105 inch(2.67 mm)]. 3.4.5 Sure-Weld FleeceBACK TPO Membrane: Sure- 3.3 PVC Membranes: Weld FleeceBACK TPO Membrane is the Sure-Weld HS 3.3.1 Sure-Flex PVC Membrane: Sure Flex PVC TPO Membrane, 45 mils [0.045 inch (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils [0.60 inch (2.03 mm)] Membrane is a heat weldable PVC thermoplastic membrane consisting of a weft-inserted polyester fabric that thick, with a laminated milsp [0.10000r inchflee(2.54 backing. Available is encapsulated by PVC based top and bottom plies. thicknesses are 100 mm)], 115 mils Available thicknesses range from 50 mils [0.050 inch [0.115 inch(2.92 mm)]and 135 mils[0.135 inch(3.43 mm)]. (1.27 mm)]to 80 mils [0.080 inch (203 mm)]. 3.4.6 Sure-Weld AFX TPO Membrane: Sure-Weld AFX TPO Membrane is the Sure-Weld HS TPO Membrane with 3.3.2 Sure-Flex KEE HP Membrane: Sure Flex KEE HP a laminated polyester fleece backing.Available thicknesses Membrane is a heat-weldable thermoplastic membrane that range consists of a polyester fabric that is encapsulated by KEE from120 mils [0.120 inch (3.05 mm)] to 155 mils HP based top and bottom plies.Available thicknesses range [0.155 inch (3.94 mm)]. from 50 mils [0.50 inch (1.27 mm)] to 80 mils [0.80 inch 3.4.7 Spectro-Weld TPO Membrane: Spectro-Weld TPO (2.03 mm)]. Membrane is the Sure-Weld membrane, described in 3.3.3 Sure-Flex PVC FRS Membrane: Sure Flex PVC Section 3.4.1, formulated with a brighter white color. Available thicknesses are 60 mils [0.060 inch (1.52 mm)] FRS Membrane is a heat-weldable thermoplastic and 80 mils [0.080 inch (2.03 mm)]. membrane that consists of a fiberglass reinforcement encapsulated with PVC based top and bottom plies. 3.4.8 Spectro-Weld FleeceBACK TPO Membrane: Available thicknesses range from 60 mils [0.60 inch Spectro-Weld FleeceBACK TPO Membrane is the Spectro- (1.52 mm)]to 80 mils [0.80 inch (2.03 mm)]. Weld membrane with a laminated 5.5-ounce-per-square- yard (0.18 kg/m2) polyester fleece backing. Available in a 3.3.4 Sure-Flex PVC FleeceBACK Membrane:Sure-Flex thickness of 115 mils[0.115 inch (2.92 mm)]. PVC FleeceBACK Membrane consists of polyester reinforcing scrim and polyester fleece backing. Available 3.5 Insulation: thicknesses range from 115 mils [0.115 inch (2.92 mm)] to See Tables 2 through 5 for insulations for use with specific 135 mils[0.135 inch (3.43 mm)]. roofing systems. Insulation must comply with IBC Section 3.3.5 Sure-Flex KEE HP FleeceBACK Membrane: Sure- 1508.2 or IRC Section R906.2, as applicable. Foam plastic Flex KEE HP FleeceBACK Membrane consists of a insulation, where used, must have a flame-spread index of polyester reinforcing scrim, polyester fleece backing, and not more than 75 when tested at the maximum thickness DuPont° Elvaloy® KEE HP copolymer. Available intended for use in accordance with ASTM E84 or UL 723. thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 3.6 Barrier Board: 135 mils[0.135 inch (3.43 mm)]. Barrier board, where used, must be either minimum 3.3.6 Sure-Flex PVC FRS FleeceBACK Membrane: 1/4-inch-thick (6.4 mm) Georgia-Pacific Gypsum LLC Sure-Flex PVC FRS FleeceBACK Membrane consists of a "DensDeck®Roofboard" or"DensDeck Prime°Roofboard," high-strength fiberglass scrim and polyester fleece backing. minimum 1/4-inch-thick (6.4 mm) Owens Corning Available thicknesses range from 115 mils "StrataGuard," minimum 1/4-inch-thick (6.4 mm) USG [0.115 inch (2.92 mm)]to 135 mils [0.135 inch (3.43 mm)]. Corporation "SECUROCK° Gypsum-Fiber Roof Board" 3.3.7 Sure-Flex KEE HP FRS FleeceBACK Membrane: or "SECUROCK° Glass-Mat Roof Board," or minimum Sure-Flex KEE HP FRS FleeceBACK Membrane consists 1/2-inch-thick (12.7 mm) gypsum board. Barrier board must of a fiberglass reinforcing scrim, polyester fleece backing, be UL-classified for roofing applications or UL-classified and DuPont° Elvaloy° KEE HP copolymer. Available gypsum board. thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 3.7 Slip Sheet: 135 mils[0.135 inch (3.43 mm)]. The slip sheet,where used, must include Carlisle"FR Base 3.4 TPO Membranes: Sheet 1 S or 2S," GAF "VersaShield° Fire-Resistant Roof 3.4.1 Sure-Weld TPO Membrane: Sure-Weld TPO Deck Protection(ESR-2053)"or Atlas"FR 10 or FR 50."Slip Membrane consists of a polyester reinforcement sheets must be UL classified for roofing applications. encapsulated between two plies of TPO. The membrane is 3.8 Flashing: available in white, gray, tan and custom colors. Available Flashing must be provided in accordance with IBC Section thicknesses range from 45 mils [0.045 inch (1.14 mm)] to 1503.2 or IRC Section R903.2, as applicable. Where 60 mils[0.060 inch (1.52 mm)]. flashing is of metal, the metal must be corrosion-resistant, 3.4.2 Sure-Weld EXTRA TPO Membrane: Sure-Weld minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized EXTRA TPO Membrane is a thicker version of the Sure- steel. ESR-1463 I Most Widely Accepted and Trusted Page 3 of 14 3.9 Fasteners: penetrate through the steel deck a minimum of 3/4 inch Fasteners, used to mechanically attach insulation and (19.1 mm), and into the wood deck a minimum of 1 inch membranes to the roof deck, must be corrosion-resistant, (25.4 mm). and must be Carlisle fasteners, plates or fastening bars, 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- unless otherwise noted in this report. Refer to Table 4 and diameter galvalume-coated steel plate designed to be used 5 for spacing of fasteners. with HP-X fasteners to mechanically attach PVC and TPO 3.9.1 HP Fastener: This is an epoxy-coated steel screw membranes to the roof deck. used in combination with Carlisle's fastening plates or bars 3.9.12 HP-XTRA Fastener:This is an epoxy-coated carbon to mechanically attach roofing insulation and membranes to steel screw used in combination with the Piranha XTRA steel or wood substrate. Fastener length must be selected Fastening Plate to mechanically attach PVC and TPO to penetrate through the steel deck a minimum of 3/4 inch membranes to steel or wood substrate. Fastener length (19.1 mm), and into the wood deck a minimum of must be selected to penetrate through the steel deck a 1 inch (25.4 mm). minimum of 3/4 inch (19.1 mm) and into the wood deck a 3.9.2 InsulFast Insulation Fastener: This is an epoxy- minimum of 1 inch (25.4 mm). coated steel screw used in combination with Carlisle's 3.9.13 Piranha XTRA Fastening Plate: This is a 23/s-inch- insulation plates to mechanically attach roofing insulation to diameter galvalume-coated steel plate designed to be used steel or wood substrates. Fastener length must be selected with HP-XTRA fasteners to mechanically attach PVC and to penetrate through the steel deck a minimum of 3/4 inch TPO membranes to the roof deck. (19.1 mm), or into the wood deck a minimum of 3.9.14 PVC Oval Barbed Plate: This is a 11/2-inch-by- 1 inch (25.4 mm). 23/4-inch(35 mm by 69.85 mm)Oval Barbed Plate designed 3.9.3 HP Purlin Fastener: This is an epoxy-coated steel to be used with HP-X Fasteners to mechanically attach PVC screw used in combination with Carlisle's fastening plates or membranes to the roof deck. bars to mechanically attach roofing insulation and 3.9.15 OMG Roofing Products RhinoBond Plate: The membranes to structural steel members. Fastener length RhinoBond Plate is a 3-inch-diameter (76.2 mm), must be selected to penetrate through the steel member a 0.028 inch thick (0.7 mm) galvalume-coated steel plate, minimum of 3/4 inch (19.1 mm.) coated with a proprietary adhesive and used with the HP-X 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy- fastener to mechanically attach PVC and TPO membranes coated steel screw used in combination with Carlisle's to the roof deck. The adhesive bonds the plate to the fastening plates or bars to mechanically attach roofing underside of the membrane. insulation and membranes to concrete roof deck. Fastener 3.10 Carlisle SynTec Adhesives: See Tables 2 and 5 for length must be selected to penetrate into the concrete deck adhered roofing systems. a minimum of 1 inch (25.4 mm). 3.9.5 CD-10 Fastener: The CD 10 is an epoxy coated, 3.10.1 90-8-30A Bonding Adhesive: 90-8-30A Bonding hammer-driven, nonthreaded fastener specifically designed Adhesive is a high strength, solvent based contact to be used with insulation and seam fastening plates to adhesive used to adhere EPDM membranes to the secure membrane and insulation to structural concrete. insulation or substrate. It has a coverage rate of Fastener length must be selected to penetrate into the approximately 60 square feet per gallon (1.5 m2/L) when concrete deck a minimum of 1 inch (25.4 mm). applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life 3.9.6 Lite-Deck Fastener:The Lite-Deck Fastener is used of one year. in conjunction with a specially designed 3-inch 3.10.2 Aqua Base 120 Bonding Adhesive:Aqua Base 120 (76.2 mm) Lite-Deck Metal Plate for insulation attachment Bonding Adhesive is a high strength, water based contact to gypsum, cementitious wood fiber (Tectum [ESR 1112]), adhesive used to adhere EPDM and TPO membranes to the and lightweight concrete decks. Fastener length must be insulation or substrate. It has a coverage rate of selected to penetrate into the deck a minimum of 2 inches approximately 120 square feet per gallon (3 m2/L) when (50.8 mm). applied to the finished surface area. The adhesive is 3.9.7 GypTec Fastener:The GypTec Fastener is a glass- supplied in 5-gallon (18.9 L) containers and has a shelf life filled nylon auger fastener designed for securing of one year. mechanically attached membranes and insulation to 3.10.3 Low-VOC PVC Bonding Adhesives: Low VOC gypsum and cementitious wood fiber(Tectum [ESR-1112]) PVC Bonding Adhesives is high strength, solvent based decks. Fastener length must be selected to penetrate into contact adhesives used to adhere PVC membranes to an the deck a minimum of 1.5 inches(38.1 mm). insulation or substrate. They have a coverage rate of 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter approximately 60 square feet per gallon (1.5 m2/L) when (50 mm)polymer plate designed to be used with HP and HD applied to the finished surface area. The adhesive is 14-10 fasteners to mechanically attach roofing membranes supplied in 5-gallon (18.9 L) containers with a shelf life of to the roof deck. one year. 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is 3.10.4 Sure-Weld TPO Bonding Adhesive: Sure-Weld a heavy-duty, epoxy-coated steel screw and bar used to TPO Bonding Adhesive is a high-strength, solvent-based secure reinforced EPDM membranes to steel or wood deck. contact adhesive used to adhere TPO membranes to an The bar is 1-inch-wide-by-0.040-inch-thick-by-10-foot-long insulation or substrate. It has a coverage rate of (25.4 mm by 1.1 mm by 3.1 m)galvalume-coated steel with approximately 60 square feet per gallon (1.5 m2/L) when pre-punched holes 6 inches(150 mm)on center. applied to the finished surface area. The adhesive is 3.9.10 HP-X Fastener: This is an epoxy-coated carbon supplied in 5-gallon (18.9 L) containers with a shelf life of steel screw used in combination with the Piranha Fastening one year. Plate to mechanically attach TPO membranes to steel or 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding wood substrate. Fastener length must be selected to Adhesive is a high-strength, solvent-based contact ESR-1463 I Most Widely Accepted and Trusted Page 4 of 14 adhesive used to adhere EPDM and TPO membranes to an 4.0 INSTALLATION insulation or substrate. It has a coverage rate of 4.1 General: approximately 60 square feet per gallon (1.5 m2/ L) when applied to the finished surface area. The adhesive is Installation of the EPDM, PVC, and TPO roofing supplied in 5-gallon (18.9 L) containers with a shelf life of membranes described in this report must comply with the one year. applicable code, the manufacturer's published installation 3.10.6 HydroBond Water-Based Bonding Adhesive: instructions and this report. The manufacturer's published HydroBond Water-Based Bonding Adhesive is a water- installation instructions must be available at all times on the based,wet lay-in, one-sided adhesive to be used to adhere jobsite during installation. Sure-Flex PVC, Sure-Flex PVC FRS and FleeceBACK The substrate to which the membrane is to be applied membranes to an insulation or substrate. It has a coverage must be clean, dry, and free of frost, loose fasteners, and rate of 100 square feet per gallon (2.5 m2/L). The adhesive other protrusions or contaminates that will interfere with the is supplied in 5-gallon (918.9 L) containers with a shelf life adhesion or attachment of the membrane or that will of one year. puncture the membrane. All materials must be protected 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC against contact with incompatible materials.Where gypsum Bonding Adhesive 1168 is high strength, solvent based board is used as barrier board in the roofing assembly, contact adhesive used to adhere EPDM and TPO weather protection must be provided to prevent damage to membranes to an insulation or substrate. It has a coverage the gypsum board prior to application of the roofing rate of approximately 60 square feet per gallon (1.58 m2/L) membrane. when applied to the finished surface area. The adhesive is The slope of the roof on which the single-ply membranes supplied in 5-gallon (18.9 L) containers with a shelf life of are installed must not be more than the maximum slope one year. indicated for the particular assembly as listed in Tables 2 3.10.8 Cold Applied Adhesive: Cold Applied Adhesive is a and 3. solvent-free, asphalt-modified polyether adhesive. This Penetrations and terminations of the roof covering must adhesive can be used with all Sure-Seal or Sure-Weld AFX be flashed and made weather tight in accordance with the membranes as a one-sided, wet lay-in adhesive. It has a requirements of the membrane manufacturer and the coverage rate of 67 square feet per gallon (1.6 m2/L). The applicable code. adhesive is supplied in 5-gallon (18.9 L) containers with a 4.2 Fire Classification: shelf life of one year. 3.10.9 Flexible FAST Adhesives: Flexible FAST 4.2.1 New Construction: The adhered and mechanically Adhesives are two-component polyurethane adhesives fastened EPDM, PVC, and TPO single ply membrane used to adhere FleeceBACK membranes and insulations to roofing systems, when installed in accordance with this various substrates. The adhesives have a coverage rate of report, are Class A, B or C roof covering systems in approximately 100 square feet per gallon (2.5 m2/L). The accordance with ASTM E108 or UL 790, as noted in Tables adhesives are supplied in 5-gallon (18.9 L)jugs, 15-gallon 2 and 3. (56.7 L) and 50-gallon (189 L) drums, box sets, cartridge 4.2.2 Reroofing: The existing deck must be inspected to tubes, dual tanks, and/or cylinders, and have a shelf life of verify that the structure to be reroofed is structurally sound one year. and adequate to support and secure the roofing membrane. 3.10.10 OlyBond 500 Adhesive: OMG Roofing Products Prior to installation of new roof coverings, inspection by and OlyBond 500 Spot Shot and OlyBond 500 BA are written approval from the code official having jurisdiction two-component polyurethane adhesives used to adhere must be required. insulations to various substrates. The adhesives have a Class A, B or C roof covering systems may be installed coverage rate of approximately 100 square feet per gallon over existing classified roof covering systems under the (2.5 m2/L). The adhesives are supplied in cartridge tubes following conditions without additional roof classification and box sets, and have a shelf life of one year. tests, provided the resulting classification is the lower of the 3.10.11 EPDM X-23 Low-VOC Bonding Adhesive: new or existing roofing classification: EPDM X-23 Low-VOC Bonding Adhesive is a high strength, • New uninsulated systems installed only over existing solvent-based contact adhesive used to adhere EPDM uninsulated assemblies. membranes to an insulation or substrate. It has a coverage • New insulated systems installed over existing rate of approximately 60 square feet per gallon (1.5 m /L) uninsulated systems only. when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of 4.3 Wind Resistance: one year. 4.3.1 New Construction: The allowable wind uplift 3.10.12 CAV-GRIP III Low-VOC Adhesive/Primer: CAV- pressures for the EPDM,PVC,and TPO roofing membranes GRIP III Low-VOC Adhesive/Primer is a contact adhesive as parts of roof assemblies are noted in Tables 4 and 5. used to adhere EPDM and TPO membranes to various Metal edge securement systems must be listed in substrates. It has a coverage rate of 1000 ft2 per cylinder accordance with the 2017 edition of ANSI/SPRI/FM4435 when applied to the finished surface area. The adhesive is ES-1 and designed and installed for wind loads in supplied in No. 40 cylinders with a shelf life of one year accordance with 2021 IBC Section 1504.6 [2018, 2015, (unopened). 2012 and 2009 IBC Section 1504.5]and IBC Chapter 16. 3.11 Impact Resistance: 4.3.2 Reroofing: Mechanically anchored systems may be The EPDM, PVC, and TPO roofing membranes described accepted based on the adequacy of anchors penetrating in this report meet requirements for impact resistance in through existing roof coverings into structural substrates. 2021 IBC Section 1504.8 [2018, 2015, 2012 and 2009 IBC Since the composition and/or condition of any particular Section 1504.7], based on testing in accordance with existing underlying material may vary widely, reroofing with Section 4.6 of FM 4470. adhered systems is outside the scope of this report. ESR-1463 I Most Widely Accepted and Trusted Page 5 of 14 5.0 CONDITIONS OF USE 7.0 IDENTIFICATION The single-ply EPDM, PVC, and TPO roofing membranes 7.1 The ICC-ES mark of conformity, electronic labeling, or described in this report comply with, or are suitable the evaluation report number (ICC-ES ESR-1463) alternatives to what is specified in, those codes listed in along with the name, registered trademark, or Section 1.0 of this report,subject to the following conditions: registered logo of the report holder or listee must be 5.1 Installation must comply with the applicable code, the included in the product label. [Electronic labeling is the manufacturer's published installation instructions and ICC-ES web address (www.icc-es.org); specific URL this report. The instructions within this report must related to the report; or the ICC-ES machine-readable govern if there are any conflicts between the code placed on the aforementioned items.] manufacturer's installation instructions and this report. 7.2 In, addition, tach roll of the roofing membrane must 5.2 The adhered and mechanically fastened single-ply bear a label noting the product name, the membrane roofing systems must be installed by manufacturer's name(Carlisle SynTec Systems)or the professional roofing contractors who are trained and name of the additional listee, the manufacturer's approved by the manufacturer. address or plant code and the ICC-ES evaluation 5.3 Foam plastic insulation must be separated from the report number(ESR-1463). interior of the building by an approved thermal barrier 7.3 The report holder's contact information is the following: in accordance with IBC Section 2603.4.1.5 or IRC Section R316.4, as applicable. CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC 5.4 Foam plastic insulation, where used, must bear the POST OFFICE BOX 7000 label of an approved agency indicating that the foam CARLISLE, PENNSYLVANIA 17013 plastic has a flame-spread index of not more than 75 (717)245-7000 when tested at the maximum thickness intended for www.carlislesvntec.com use in accordance with ASTM E84 or UL 723, subject to the approval of the code official. 7.4 The Additional Listees' contact information is the 5.5 Design wind uplift pressure on any roof area, including following: edge and corner zones, must not exceed the allowable MULE-HIDE PRODUCTS COMPANY, INC. wind uplift pressure for the system installed in that 1195 PRINCE HALL DRIVE particular area. Refer to allowable wind uplift pressures BELOIT,WISCONSIN 53511 for systems as listed in Tables 4 and 5. (800)786-1492 5.6 The allowable wind uplift pressures listed in Tables 4 and 5 are for the roof covering system only. The deck VERSICO,A DIVISION OF CARLISLE and framing to which the system is attached must be CONSTRUCTION MATERIALS, LLC designed for the applicable components and cladding POST OFFICE BOX 1289 wind loads in accordance with the applicable code. CARLISLE, PA 17013 (800)992-7663 5.7 When application is over existing roofs,documentation of the wind-uplift resistance of the composite roof WEATHERBOND,A DIVISION OF CARLISLE construction must be submitted to the code official for CONSTRUCTION MATERIALS, LLC approval at the time of permit application. POST OFFICE BOX 251 5.8 For buildings under the IBC, above deck thermal PLAINFIELD, PENNSYLVANIA 17081 insulation board must comply with the applicable (866)471-5125 standards listed in IBC Table 1508.2 or IRC Table R906.2, as applicable. ROOFING PRODUCTS INTERNATIONAL, INC. 5.9 The roofing membranes are manufactured at Carlisle, 57460 DEWITT STREET Pennsylvania; Greenville, Illinois; Tooele, Utah; and ELKHART, INDIANA 46517 Senatobia, Mississippi,under a quality control program (800)628-2957 with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC-ES Acceptance Criteria for Membrane Roof-covering Systems (AC75), dated July 2010 (editorially revised April 2021). ESR-1463 I Most Widely Accepted and Trusted Page 6 of 14 TABLE 1—PRODUCT NAMES CARLISLE MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND PRODUCT ROOFING PRODUCTS PRODUCT NAME NAME NAME NAME INTERNATIONAL PRODUCT NAME Sure-Seal EPDM Mule-Hide Standard VersiGard Non-reinforced WeatherBond EPDM Non- Royal Edge Non- Black EPDM EPDM Reinforced Membrane Reinforced EPDM Sure-Seal FR EPDM Mule-Hide FR EPDM VersiGard FR Non- WeatherBond EPDM FR Royal Edge Non- Reinforced EPDM Non-Reinforced Membrane Reinforced FR EPDM Sure-Seal FleeceBACK WeatherBond Fleece EPDM Royal Edge EPDM EPDM - VersiFleece EPDM Membrane FleeceBACK Sure-Seal AFX EPDM - VersiFleece AC EPDM WeatherBond EPDM AC - Fleece Membrane Sure-Tough EPDM Mule-Hide Standard VersiGard Reinforced WeatherBond EPDM Royal Edge Reinforced Reinforced EPDM EPDM Reinforced Membrane EPDM Sure-White EPDM Mule-Hide White-on- VersiGard—White WeatherBond EPDM White Re-Flex White EPDM Black EPDM Standard Membrane Sure-White Reinforced Mule-Hide White on VersiGard White WeatherBond EPDM White - EPDM Black Reinforced EPDM Reinforced EPDM Reinforced Membrane Sure-White Re-Flex White EPDM FleeceBACK FleeceBACK Sure-Weld TPO Mule-Hide TPO-c VersiWeld Reinforced WeatherBond TPO Re-Flex TPO TPO Membrane Membrane Sure-Weld HS TPO Mule-Hide TPO-c(FR) VersiWeld HS WeatherBond TPO High Re-Flex TPO HS Slope Membrane Sure-Weld SAT-TPO Mule-Hide SA-TPO VersiWeld QA TPO WeatherBond TPO PAS Re-Flex TPO SAT Membrane Membrane Sure-Weld TPO Mule-Hide TPO-c WeatherBond FleeceTPO Re-Flex TPO FleeceBACK Fleece Back VersiFleece TPO Membrane FleeceBACK Sure-Weld TPO AFX Mule-Hide TPO-c VersiFleece AC TPO WeatherBond TPO AC Fleece Back Plus Fleece Membrane Spectro-Weld TPO - - - - Spectro-Weld - FleeceBACK TPO Mule-Hide PVC WeatherBond PVC Re-Flex PVC Sure-Flex PVC Membrane VersiFlex PVC Membrane Mule-Hide PVC KEE HP WeatherBond KEE HP Re-Flex KEE HP Sure-Flex KEE HP Membrane VersiFlex KEE HP Membrane Sure-Flex PVC FRS Mule-Hide PVC FRS VersiFlex FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC Membrane Membrane Sure-Flex PVC Mule-Hide PVC VersiFleece PVC WeatherBond PVC Fleece - FleeceBACK FleeceBack Membrane Membrane Sure-Flex KEE HP Mule-Hide PVC KEE HP VersiFleece KEE HP WeatherBond KEE HP - FleeceBACK Fleece Back Membrane Fleece Membrane Sure-Flex PVC FRS VersiFleece FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC FleeceBACK Fleece Membrane FleeceBACK Sure-Flex KEE HP FRS VersiFleece FRS KEE HP WeatherBond KEE HP FRS - - FleeceBACK Fleece Membrane 90-8-30A Bonding Mule-Hide Bonding G200SA Yellow LC-60 Bonding Adhesive Royal Edge Bonding Adhesive Adhesive Substrate Adhesive Adhesive EPDM X-23 Low-VOC EPDM X-23 Low VOC EPDM X-23 Low VOC EPDM X-23 Low VOC - Bonding Adhesive Bonding Adhesive Bonding Adhesive Bonding Adhesive Aqua Base 120 Bonding Aqua Base 120 Bonding Aqua Base 120 Bonding Aqua Base 120 Bonding Royal Edge Water Based Adhesive Adhesive Adhesive Adhesive Bonding Adhesive Sure-Weld TPO Mule-Hide TPO-c VersiWeld TPO Bonding TPO Bonding Adhesive Royal Edge EPDM/TPO Bonding Adhesive Bonding Adhesive Adhesive Bonding Adhesive Low VOC Bonding Low VOC Bonding LOW VOC Bonding Low VOC Bonding Adhesive Royal Edge Low VOC Adhesive Adhesive Adhesive Bonding Adhesive Low VOC Bonding Low VOC Bonding Low VOC Bonding Low VOC Bonding Adhesive -- Adhesive 1168 Adhesive 1168 Adhesive 1168 1168 Low VOC PVC Bonding Low-VOC PVC Bonding Low-VOC PVC Bonding Low-VOC PVC Bonding Re-Flex PVC Low VOC Adhesive Adhesive Adhesive Adhesive Bonding Adhesive HydroBond Water- HydroBond Water- HydroBond Water-Based HydroBond Water-Based Based Bonding Based Bonding I Bonding Adhesive Bonding Adhesive Adhesive Adhesive- CAV-GRIP III Low VOC Cav-Grip 3V Low VOC Cav-Grip III Low VOC - Adhesive/Primer AeroWeb Adhesive Adhesive/Primer Adhesive/Primer ESR-1463 I Most Widely Accepted and Trusted Page 7 of 14 TABLE 1—PRODUCT NAMES(continued) CARLISLE MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND ROOFING PRODUCTS PRODUCT NAME NAME NAME PRODUCT NAME INTERNATIONAL PRODUCT NAME Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive RPI Cold Applied Adhesive Flexible FAST Adhesive Helix®Max Low-Rise Flexible DASH Adhesive Flexible DASH Adhesive FastBond Flex Adhesive Adhesive OlyBond 500 Adhesive - OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2,5 SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 1 1/4:12 Sure-Weld,Spectro-Weld Sure-Seal FR,Sure-Tough, Sure-White,Sure-Seal FleeceBACK, 2 1/2:12 Any of the following Sure-Weld HS,Sure-Weld SAT-TPO, insulations, 1-inch min. Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK, thickness:Carlisle A Noncombustible — "SecurShield Polyiso", Sure-White FleeceBACK "InsulBase", Hunter Sure-Flex PVC FleeceBACK, Panels"H-Shield"or"H- Sure-Flex KEE HP FleeceBACK, 3 3/4:12 Shield-CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 4 1'1A:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP 5 3/4:12 Sure-White FleeceBACK 6 1:12 Sure-Seal FR,Sure-Tough 1/2-inch-thick fiberboard4, Sure-White,Sure-Seal FleeceBACK, 1/2-inch-thick fiberboard4 Sure-Weld,Spectro-Weld,Sure-Weld or barrier board HS,Sure-Weld SAT-TPO, (see Section 3.6)over Sure-Weld FleeceBACK, A Noncombustible — 5-inch max Insulfoam EPS3, '/2-inch-thick Spectro-Weld FleeceBACK, 7 11/2:12 fiberboard or barrier board Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP, (see Section 3.6)over System No. 1 insulations Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 8 3/4:12 Sure-White FleeceBACK 9 11/2:12 Sure-White,Sure-Seal FleeceBACK Sure-Tough,Sure-Weld,Spectro-Weld, 10 Noncombustible 3:12 1/4-inch thick Sure-Weld FleeceBACK, or Combustible "DensDeck Prime" Spectro-Weld FleeceBACK 11 A -min.15/32-inch- 4:12 or'/4-inch thick _ Sure-Weld HS,Sure-Weld SAT-TPO thick plywood or "SECUROCK 12 min.7/16-inch- Unlimited Gypsum Fiber Roof Sure-Seal FR,Sure-Flex PVC, thick OSB. Board" Sure-Flex PVC FRS,Sure-Flex KEE HP Sure-Flex PVC FleeceBACK, 13 3:12 Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBack ESR-1463 I Most Widely Accepted and Trusted Page 8 of 14 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2'5(continued) SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 14 1/4:12 Sure-Weld,Spectro-Weld Sure-Seal FR,Sure-Tough,Sure-White, Sure-Seal FleeceBACK,Sure-Weld HS, 15 1/2:12 Any of the following Sure-Weld SAT-TPO,Sure-Weld Combustible insulations, 1-inch min. FleeceBACK,Sp ectro Weld min.15/32-inch- Barrier board thickness:Carlisle A thick plywood or (see Section 3.6)or "SecurShield Polyiso", FleeceBACK,Sure-White FleeceBACK min.'/16-inch- Slip sheet:2 layers "InsulBase",Hunter Panels Sure-Flex PVC FleeceBACK, 16 thick OSB. 3/4:12 (see Section 3.7) "H-Shield"or"H-Shield- Sure-Flex KEE HP FleeceBACK, CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE FRS FleeceBACK 17 2:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP Noncombustible or Any of the following Combustible insulations,min. 1-inch. Any EPDM,PVC or TPO Membrane 18 C min. /32-inch- Unlimited — thickness:Carlisle specified in this report thick plywood or "InsulBase"or Hunter min.7/16-inch- Panels"H-Shield" thick OSB. Single layer of minimum 3.0"or double layer of 19 A Combustible /2:12 — minimum 1.5"Carlisle Any EPDM,PVC or TPO Membrane "SecurShield Polyiso"or specified in this report Hunter Panels "H-Shield-CG" Single layer of minimum Any EPDM,PVC or TPO Membrane 20 A Combustible 1/2:12 — 1.9"Carlisle"SecurShield specified in this report Polyiso"or Hunter Panels "H-Shield-CG" Min.'/2-to 3-inch-thick Sure-White Reinforced EPDM 21 A Noncombustible 1:12 — Carlisle HP Recovery Membrane Board Any of the following 1/2-inch-thick gypsum insulations, 1-inch min. board or 1/4-inch- thickness:Carlisle Sure White Reinforced EPDM 22 A Combustible 11/2:12 thick"DensDeck "SecurShield Polyiso"," Membrane Roofboard"or InsulBase",Hunter Panels "DensDeck Prime," "H-Shield"or"H-Shield- CG" For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2See Section 3.10 for adhesive application rate. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to max.1/2:12. 5When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021 IBC Section 1512,2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 9 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS" SYSTEM ROOF DECK MAX. BARRIER BOARD INSULATION' MEMBRANE/MAX.ROOF SLOPE NO. CLASS SLOPE OR SLIP SHEET 1 /2:12 Any of the following Sure-Tough,Sure-Weld, insulations, 1-inch min. Spectro-Weld 2 A Noncombustible 11/2:12 — thickness:Carlisle Sure-Weld HS "SecurShield Polyiso"or 3 21/2:12 "InsulBase", Hunter Panels Sure-Flex PVC,Sure-Flex KEE HP "H-Shield"or"H-Shield-CG" 4 1:12 1/2-inch-thick fiberboard3, Sure-Tough,Sure-Flex /2-inch-thick fiberboard or barrier board (see Section 3.6)over 5-inch A Noncombustible — max Insulfoam EPS2, 5 11/2:12 1/2-inch-thick fiberboard or Sure Weld,Spectro-Weld, barrier board Sure-Weld HS (see Section 3.6)over System No. 1 insulations Insulfoam SP,5-inch max Sure-Weld,Spectro-Weld, 6 A Noncombustible 1/2:12 — thickness Sure-Weld HS,Sure-Flex, Sure-Flex KEE HP "Insulfoam SP"or min.1/2- Sure-Weld,Spectro-Weld, 7 A Noncombustible 1:12 — inch-thick Insulfoam EPS Sure-Weld HS,Sure-Tough covered with"Insulfoam SP" 8 Noncombustible 3:12 Sure-Tough,Sure-Weld,Spectro-Weld or Combustible 9 A min.15/32-inch- 31/2:12 Barrier board — Sure-Tough FR thick plywood or (see Section 3.6) min.7/16-inch- Sure-Weld HS,Sure-Flex, 10 thick OSB. Unlimited Sure-Flex KEE HP 11 1/2:12 Any of the following Sure-Tough,Sure-Weld,Spectro-Weld Combustible insulations, 1-inch min.to min. 15/32-inch- 1 Barrier board 6-inch max.thickness: 12 1 /2:12 (see Section 3.6)or Sure-Weld HS A thick plywood or Carlisle"SecurShield — 13 min.7/16-inch- 3/4:12 Slip sheet:2 layers, Polyiso"or"InsulBase", Sure-Tough FR thick OSB. (see Section 3.7) Hunter Panels"H-Shield"or 14 21/2:12 "H-Shield-CG" Sure-Flex PVC,Sure-Flex KEE HP 15 Combustible 1:12 Sure-Tough min.15/32 inch- Slip sheet,2 layers A thick plywood or — Sure-Tough FR,Sure Weld, (see Section 3.7) 16 min.7/16-inch- 11/2:12 Spectro-Weld,Sure-Weld HS, thick OSB Sure-Flex,Sure-Flex KEE HP Combustible min.15/32-inch- Slip sheet, Sure-Tough,Sure-Tough FR, 17 B thick plywood or 11/2:12 1 layer — Sure-Weld,Spectro-Weld,Sure-Weld min.7/16-inch- (see Section 3.7) HS,Sure-Flex,Sure-Flex KEE HP thick OSB. Combustible Any of the following min 15/32 inch- insulations, 1-inch min. 18 C thick plywood or Unlimited — thickness:Carlisle Any EPDM, PVC or TPO Membrane min.'/1s inch- "SecurShield Polyiso"or specified in this report thick OSB. "InsulBase",Hunter Panels "H-Shield"or H-Shield CG" Single layer or double layer of 19 A Combustible /2:12 — minimum 1-inch Carlisle Any EPDM, PVC or TPO Membrane "SecurShield Polyiso"or specified in this report Hunter Panels"H-Shield-CG" Minimum 1/2-inch Carlisle"SecurShield HD,""SecurShield HD Plus," Any EPDM, PVC or TPO Membrane 20 A Combustible 1:12 — "SecurShield HD NH", "SecurShield HD Plus NH", specified in this report "SecurShield HD Plus",or "SecurShield HD RL" Any of the following insulations, 1-inch min. 21 A Noncombustible 1:12 — thickness:Carlisle Sure-White Reinforced EPDM "SecurShield Polyiso"or Membrane "InsulBase",Hunter Panels "H-Shield"or"H-Shield-CG" ESR-1463 I Most Widely Accepted and Trusted Page 10 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS°(continued) SYSTEM ROOF DECK MAX. BARRIER BOARD INSULATION' MEMBRANE/MAX. ROOF SLOPE NO. CLASS SLOPE OR SLIP SHEET 1/2-inch-thick gypsum Any of the following board or'/4 inch- insulations, 1-inch min. 22 A Combustible 2:12 thick"DensDeck thickness:Carlisle Sure-White Reinforced EPDM Roofboard"or "SecurShield Polyiso," Membrane "DensDeck Prime," "InsulBase", Hunter Panels "H-Shield"or"H-Shield-CG" Any of the following insulations, 1-inch min. 23 A Noncombustible /2:12 — thickness:Carlisle Sure-White Reinforced EPDM "SecurShield Polyiso," Membrane "InsulBase", Hunter Panels "H-Shield"or"H-Shield-CG" For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. TABLE 4—WIND RESISTANCE—ADHERED ASSEMBLIES5'6 ALLOWABLE INSULATION SYSTEM WIND UPLIFT DECK2 INSULATION/MIN.THICKNESS''3 FASTENING MEMBRANE NO. (FIELD) RATE TYPE (psf) Combustible or 1/2-inch fiberboard4,15/32-inch OSB,or'/4-inch thick EPDM, PVC and TPO 1 45 Noncombustible "DensDeck Prime"or 1/4-inch thick"SECUROCK 1 per 2 ft2 Membranes Gypsum Fiber Roof Board" Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 2 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/1.4 inch 1 per 3.2 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 3 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 4 ft2 EPDM, PVC and TPO Noncombustible with 5/8-inch SECUROCK coverboard(optional) Membranes 4 68 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/1.0 inch Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 5 75 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1.6 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes 6 113 Combustible or Carlisle"SecurShield"or"H-Shield CG"/2.0 inch 1 per 1ft2 PVC Membranes Noncombustible TPO Membranes 7 120 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 1per 1 ft2 EPDM membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch p (with noncombustible deck only) Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 8 128 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 EPDM and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 9 135 Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 FleeceBACK Membranes with'/2-inch SECUROCK coverboard(optional) 10 143 Combustible or 1/2_inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes Noncombustible For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength TO of 2500 psi.See Section 5.6 of this report. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When application is over existing roofs,documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application.Since the composition and/or condition of any particular existing underlying material may vary widely,reroofing with fully adhered System No.4 is outside the scope of this report. For reroofing or recovering, installation must be in accordance with 2021 IBC Section 1512,2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. 'See Section 3.10 for adhesive application rate. ESR-1463 I Most Widely Accepted and Trusted Page 11 of 14 TABLE 5—WIND RESISTANCE—MECHANICALLY FASTENED ASSEMBLIES°' MAXIMUM MAXIMUM MAXIMUM SYSTEM ALLOWABLE DECKS INSULATIONS MEMBRANE MEMBRANE FASTENER FASTENER NO. WIND UPLIFT FASTENING SPACING ROW (psf) (inches) SPACINGS Foam plastic insulation'2' 1 45 Noncombustible 1/2-inch-thick fiberboards or Sure-Tough HP-X Fastener& 12 6 ft 6 inches barrier board Metal Fastening Bar (See Sect.3.6) — 2 75 Noncombustible Same as System No.1 Sure-Tough HP-X Fastener& 6 6 ft 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches Polymer Seam Plate 4 45 Noncombustible Same as System No.1 Sure-Tough Sure-Tite Fastener& 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 12 9 ft 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure-Weld or HP-X or HP-Xtra 7 45 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 7 ft 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure-Weld or HP-Xtra Fasteners with 12 9 ft 6 inches Spectro-Weld Piranha Xtra Plates HP-X or HP-Xtra 9 60 Noncombustible Same as System No. 1 Sure-Weld or Fasteners with 6 9 ft 6 inches Spectro-Weld Piranha or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 10 67 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 7 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 11 30 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 12 60 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure-Flex PVC or HP-X Fasteners with 6 6 ft 4 inches Sure-Flex KEE HP Piranha Plates 14 83 Noncombustible Same as System No.1 Sure-Flex PVC or HP-X Fasteners with 6 2 ft 11 inches Sure-Flex KEE HP Piranha Plates Sure-Flex PVC or HP-X or HP-Xtra 15 30 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates Sure-Flex PVC or HP-X or HP-Xtra 16 45 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure-Flex KEE Hopi.PVC or HP-X FastPiranhae Platesners with 12 2 ft 11 inches Sure-Flex PVC or HP-X or HP-Xtra 18 60 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 6 9 ft 7 inches Plates 19 45 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 5.3 ft2 N/A OMG RhinoBond Plates 20 60 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa. 'Foam plastic insulation must be any of the following(1-inch min.to 6-inch max.thickness):Carlisle"SecurShield Polyiso","InsulBase"Hunter Panels"H-Shield"or Hunter Panels"H-Shield-CG". 2All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 'Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength(fc) of 2500 psi.See Section 5.6 of this report. 'For existing metal roofing,the assemblies listed must be installed by fastening through the roofing and into structural members(purlins,angle iron,beams,etc.) capable of resisting all expected loads.The maximum allowable wind uplift(field)pressures are shown in Column 2. 5UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. 'Fastener row spaces shown are for field of roof only.See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies.Distance between the edge of the roof and the first row of fasteners must be determined accordingly. ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ESR-1463 LABC and LARC Supplement Reissued October 2022 Revised May 2023 This report is subject to renewal October 2023. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS,A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety(LADBS). Applicable code editions: • 2023 City of Los Angeles Building Code(LABC) • 2023 City of Los Angeles Residential Code(LARC) 2.0 CONCLUSIONS The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463,comply with the LABC Chapters 7A and 15,the LARC Section R337 and LARC Chapter 9,and are subjected to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in this evaluation report must comply with all of the following conditions: • All applicable sections in the evaluation report ESR-1463. • The design, installation, conditions of use and identification are in accordance with the 2021 International Building Code° (IBC)and 2021 International Residential Code°(IRC)provisions noted in the evaluation report ESR-1463. • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, or LARC Chapter 3, as applicable. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must not be installed over existing wood shakes or wood shingles in accordance with LABC Section 1512. • The installation of the Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must comply with City of Los Angeles Information Bulletin P/BC 2020-16, "Dwellings in High Wind Velocity Areas(HWA)". • Reroofing applications must comply with Sections 4.2.2,4.3.2 and 5.7 of the evaluation report ESR-1463 and LABC Section 1512 or LARC Section R908, as applicable. Where spaced sheathing exists, a minimum of 15/32-inch-thick (11.9 mm) plywood shall be installed prior to roofing installations. • Where moderate or heavy foot traffic occurs for maintenance of equipment,the roof covering shall be adequately protected. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to he construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as �� nw�e to any finding or other matter in this report,or as to any product covered by the report. CODE counblr Copyright©2023 ICC Evaluation Service,LLC. All rights reserved. Page 12 of 14 ESR-1463 LABC and LARC Supplement I Most Widely Accepted and Trusted Page 13 of 14 • The Building Inspector shall be notified 24 hours in advance prior to installation of the roof membranes. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Building Code®(IBC) provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the LABC. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.1.3 and R337.5 of the LARC. This supplement expires concurrently with the evaluation report, reissued October 2022 and revised May 2023. ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ESR-1463 CBC and CRC Supplement Reissued October 2022 Revised May 2023 This report is subject to renewal October 2023. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS,A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Carlisle EPDM, PVC and TPO single-ply roofing membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2022 California Building Code(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)AKA:California Department of Health Care Access and Information(HCAI)and the Division of State Architect(DSA), see Sections 2.1.1 and 2.1.2 below. • 2022 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CBC Chapter 15, provided the design and installation are in accordance with the 2021 International Building Code°(IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2021 International Building Code°(IBC)provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the CBC. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CRC Chapter 95, provided the design and installation are in accordance with the 2021 International Residential Code°(IRC)provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2021 International Residential Code°(IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.1.3 and R337.5 of the CRC. This supplement expires concurrently with the evaluation report, reissued October 2022 and revised May 2023. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i w to any finding or other matter in this report,or as to any product covered by the report. Copyright©2023 ICC Evaluation Service,LLC. All rights reserved. Page 14 of 14