HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0003-2023-BRES (3) e e rn e n
ENVIRONMPNTA ,f
189 County Road 135
Glenwood Springs,CO 81601
(970) 274-3139
Final Clearance Letter
For
205 E. Durant Ave. Unit 1G
Aspen, CO
June 8th, 2022
Prepared for
Soho Construction
Element Environmental Project Number
Soho 060822 Durant
Prepared By:
Joshua Johnson
CDPHE Air Monitoring Specialist#18401
CDPHE Asbestos Consulting Firm #21640
RECEIVED
01/05/2023
ELEMENTr.l�Iti., vIENTAL I Soho 060822 Durant
U2,02,2023 ASPEN
FORCOMGUIIPLIIIKE BUILDING DEPARTMENT
Element Environmental Date: 06/08/2022
189 County Rd. 135
Glenwood Springs, CO 81601
(970) 274-3139
josh@elementconsults.com
Client: Soho Construction
Dear Mr. Heath Johnson,
I am pleased to offer you this report for work performed at the reference site.
On June 8th, 2022, Mr.Joshua Johnson with Element Environmental performed final clearances at 205 E.
Durant Ave. Unit 1G,Aspen, CO. The final clearances consist of a visual inspection for dust and debris and
ambient air sampling. The final clearance consisted of 1 containment.This was an abatement to scrape ACM
ceilings throughout the unit.This was for aesthetic purposes. Some asbestos may still be remaining on the
ceiling. Great care should be taken to not disturb or sand the existing joint compound. Any material or
overspray that is remaining must be assumed to be ACM material until it is tested.
Mr.Joshua Johnson CDPHE AMS#18401 performed a visual inspection.After the visual inspection was
complete, air samples were taken of each of the work areas. Five samples were taken from the work area.
The air samples were analyzed by PCM (Phase Contrast Microscopy) per the NIOSH 7400 method.All samples
must below 0.01 f/cc in order to pass the air clearance. All samples were below the limit amount.
Per Colorado Reg 8 Part B guidelines. The work area is now clear for occupancy or normal work to
resume.
Any suspect asbestos containing materials (ACM) remaining should be assumed to contain asbestos unless
they are properly tested and analyzed by a CDPHE accredited inspector. All work performed MUST follow
appropriate EPA, CDPHE, OSHA, and local government guidelines to protect the employees, occupants, and the
environment.
Joshua Johnson Air Monitoring Specialist#18401
RECEIVED
01/05/2023
ELEMENT ,. , v fr ENTAL I Soho 060822 Durant
a2,oz,2a23 ASPEN
FORCOlkalIPLIAIKE BUILDING DEPARTMENT
e e m e n t
ENVIRONMENTAL.VC Date:06/08/2022
189 County Road 135 Client:Soho Construction
Glenwood Springs,CO 81601 Job Name:Soho 060822 Durant
(970)274-3139 Date Analyzed:06/08/2022
josh@elementconsults.com Time Requested:ASAP
AIHA Pat Proficient Lab#220213 Method:NIOSH 7400
Analyst:J.Johnson
Sample# I Volume(L) #Fields #Fibers f/mm2 f/cc and f/mm2 Fibers/cc
Fiber Detection Limit
Density
608-1 1350 100 17 21.6 0.003 0.006
608-2 1350 100 14 17.8 0.003 0.005
608-3 1350 100 16 20.3 0.003 0.005
608-4 1350 100 17 21.6 0.003 0.006
608-5 1350 100 18 22.9 0.003 0.006
608-6 0 100 0 0 7f/mm2 BDL
608-7 0 100 0 0 7f/mm2 BDL
NIOSH 7400 Method Limit of Detection=7 f/mm2 for filter area
CDPHE(MAAL)Maximum Allowable Asbestos Level.01 f/cc
*BDL=Below Detectable Limit
RECEIVED
01/05/2023
ELEMENT".vki. vAIENTAL I Soho 060822 Durant
2102/2023 ASPEN
FORCOlkalIPLIAIKE BUILDING DEPARTMENT
roi..e s :' 1. s a
r„
• -:.--Ay' ,.*� 41�`r._ ,,,fi r,^ W1..* •�* •`. t '". ' * ^ » .4.
. o'L rr."�u,,,'a:iei•W L ;u 5 y,eta;IL"6 g,:41,1&;,J�k vy •6, u U u
47r4
S�) t r/ 4
) "�Colorado Department =
iii
gi-
- ) ' of Public Health r,,zi :i=i
and Environment -_- y .1 m
_'1 -�; ASBESTOS f I
� .. CERTIFICATION* ,
-- .c<t ') »w
=�'=- ) This certifies that
• "" >'> Joshua Jay Johnson
i'�`�' t:..)) Certification No.. 18401 _ 2j,'
uck .has met the requirements of 25-7-507,C.R.S.and Air Quality Control
k _..' Commission Regulation No.8,Part B,and is hereby certified by the ' "`'\
{: ti state of Colorado in the following discipline: --
ti i.
« Air Monitoring Specialist* )'
/, <'A 'kV.--
' Issued: February 15, 2022
Expires: February 26, 2023 i
Y
.g • _
s f.
- •This certificate is valid old,with the possession of a -
- �K� Y, current Division-approved training mace certification 1
7 in the discipline specified ahoy. .-- '<
A M Yatl Repesentebve i
SEAL
aaR?;.nrA.^I?;'A !f:?':f.,R.,:?..7 11".11:.Z.Id3 fr1lifIri^�R^f.'. .a°I,^.c ,? 1 I. .. ter? �,/
A,• /* ii* 4i 4 4,/* ,it/ ,,orb, „td ;ir >»
1R y
RECEIVED
01/05/2023
ELEMENT ,vki. v lIENTAL I Soho 060822 Durant
02/02/2023 U ASPEN
FORCOMIXIIIPLWICE BUILDING DEPARTMENT
nF C
♦ Colorado Department �I
of Public Health
and Environment
1
ASBESTOS CONSULTING FIRM �'
This certifies that -. -
Element Environmental,Inc.
Registration No.:ACF-21640
has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control
Commission Regulation No.8,Part R,and is hereby authorized to perform asbestos consulting
t activities as required under Regulation No 8,Part 6,in the state of Colorado. j�
1 1
Issued: December 22,2021
Expires: January 25,2023 \ )
•" sun ='�J
it
t �
- Cnvironmental
I' Training & `,
l'
J esulting J
1. 2701 Vest Ostoed Ascnuc 07
I.ng t lewxxd, Ammkt ft01 10 p i
303 701-042__2 -
CERTIFIES THAT /
„t' JOSH JOHNSON
has successfully completed
:ill. THE NIOSH 582 EQUIVALENT COURSE -Iw
SAMPLING& EVALUATING AIRBORNE ASBESTOS DUST -�•
b..!
i '.Y1
, Course Date: 01/26-01/29,15.01i31+'IS
�` � No.of hours: d0 •,.s ,'
Exam D O ate: 1:31:15
('enifi utr No.: DO013115—43 t. e2 4
r'r i,
� Authorized Signature
•
h I
RECEIVED
01/05/2023
ELEMENTj `) ' MENTAL I Soho 060822 Durant
f02/02/2023 ASPEN
FORCO0tUa61.11410E
BUILDING DEPARTMENT