File Documents.508 E Cooper Ave.0006-2023-BCOM (6)
508 Cooper Building Comments 2 30. INTERIOR LIGHTING CUT SHEETS. 20230201.pdf(1) Subject: PlanCheck Page Label: 56 I'm not finding this fixture on the Author:justinh plan or ComCheck. File Name: 30. INTERIOR LIGHTING CUT SHEETS. - ~ -- 20230201.pdf -17 Color: ■ P1 PENDANT FIXTURES OVER THE BAR 7,7 30. INTERIOR LIGHTING PLANS AND COMCHECK. 20230201.pdf(7) --.m Subject: PlanCheck Page Label: [1] LEAX 508 COOPER BAR 1-31-2023-LD1.0 Revise code references to be Author:justinh the 2015 IECC " 1- File Name: 30. INTERIOR LIGHTING PLANS AND COMCHECK. 20230201.pdf BUILDING CODE INFORMATION Color: • CODE REVISED ON TITLE SHEET „o,. I I r°°^ Subject: PlanCheck Page Label: [1] LEAX 508 COOPER BAR 1-31-2023-LD1.0 Provide a general note that all Author:justinh controls shall be mounted 15-48" File Name: 30. INTERIOR LIGHTING PLANS AND above finish floor per ICC COMCHECK. 20230201. df A117.1 308 Provide a general note that all controls shall be mounted p 15-48"above finish floor per ICC A1171308 Color: ■ 1, HEIGHT ADDED TO TITLE SHEET Subject: PlanCheck 4 Page Label: [8] LEAX 508 COOPER BAR 1-31-2023-LD1.6 LED tape light should be entered COMCHECK as the driver wattage. Author:justinh File Name: 30. INTERIOR LIGHTING PLANS AND COMCHECK. 20230201. df p Color: ■ ALL TAPE LIGHT WATTAGE NOW DEFINED BY DRIVER WATTAGE Subject: PlanCheck Per cutsheets WS1 is 100W Fa,.a=F.wa Page Label: [8] LEAX 508 COOPER BAR 1-31-2023-LD1.6 heck•Nkh fixture,WS2 adn WS3 are 60W ®®� COMCHECK � fixtures. Author:justinh File Name: 30. INTERIOR LIGHTING PLANS AND BEIMCOMCHECK. 20230201.pdf Color: • Provide NRTL listings for those q1 �9"III fixtures, did not see that on the cutsheets. POWER FEEDING WS1, WS2 AND WS3 IS PROVIDED FROM A CURRENT LIMITED CIRCUIT. IT IS INTENDED TO LAMP THESE FIXTURES WITH LED LAMPS TO MINIMIZE THE WATTAGE AND CURRENT LIMITED POWER WILL MEAN THESE FIXTURES CANNOT BE RELAMPED WITH HIGHER WATTAGES. Subject: PlanCheck What fixtures are these? If they Page Label: [8] LEAX 508 COOPER BAR 1-31-2023-LD1.6 COMCHECK are tape light fixtures they Author:justinh should be entered as the driver File Name: 30. INTERIOR LIGHTING PLANS AND wattage. o,`, ; COMCHECK. 20230201.pdf Color: ■ LED TAPE LIGHT USING 30 WATT DRIVER. COMCHECKED FOR 30 WATTS PER FIXTURE. 3 OF THESE FIXTURES IN TOTAL w ,µ Subject: PlanCheck Code should be 2015 IECC and ������ ®®®® Page Label: [8] LEAX 508 COOPER BAR 1-31-2023-LD1.6 . COMCHECK project type should be alteration .-......; _..... so that the program does not M . -- _— , Author:justinh "' °''"'°`"°"""""" attempt to apply the additional M. File Name: 30. INTERIOR LIGHTING PLANS AND y- . energy COMCHECK. 20230201.pdf energy efficiency measures of "- Color: • C406 ' _.. \ COMCHECK CHANGED TO 2015 AND ALTERATION Subject: PlanCheck Provide the actual compliance Page Label: [8] LEAX 508 COOPER BAR 1-31-2023-LD1.6 COMCHECK report in the plan rather than this e._ Author:justinh screen shot of the input. Mil = File Name: 30. INTERIOR LIGHTING PLANS AND COMCHECK. 20230201.pdf Color: • ACTUAL REPORT PROVIDED 90. ARCHITECTURAL PLANS. 20230201.pdf(11) Subject: PlanCheck Page Label: 2 Architectural set should be Author:justinh stamped for permit submittal File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf Architectural set should be stamped Color: • for permit submittal ARCH PLANS ARE STAMPED Subject: PlanCheck Page Label: 4 The 1 occupant/5 sq.ft. occupant = -��--' 3 load factor is for standing space —F _=ff- Author:justinh only, 1/15 would be the proper .111 File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf factor for the table and chairs Color: ■ layout you show later in the set. OIL -I:: :.: We can base occupant load off r anormeenmemenno _-_ _ either the floor area factor, or by e== a_,.'- is the compliant seating plan plus employees (currently that would get you an occupant load of 52 with the 8 employees you call out and seats shown). SECOND OCCUPANCY CALC HAS BEEN ADDED FOR TABLES AND CHAIRS ALONGSIDE THE CALC FOR STANDING ROOM ON PAGE A-0.30.A NOTE HAS We could also post two different BEEN ADDED ON THE SAME PAGE ABOUT THE OFFSITE STORAGE FOR TABLES occupant loads for your space, AND CHAIRS WHEN THE STANDING ROOM OCCUPANCY WILL BE TAKING one for when tables and chairs PLACE. are present based off the seating plan and one based off 1 occ/5 sq.ft.for a standing only scenario if all tables and chairs were removed (specific events, etc.). You would need to add an occupant load calc to your floor plan showing seating (8 employees shown here+ number of seats that fit in the space compliantly)and identify where the tables and chairs would be stored if on this plan for the standing room only option (they cannot be placed in your exit stair enclosure or anywhere else that blocks egress). Call to discuss if you have questions. Subject: PlanCheck q Page Label: 5 Call out the hangers as Author:justinh metal/non-combustible for File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf compliance with IBC 803.13 Call out the hangers as and show the proposed method metal/non-combustible Color: • for compliance with of framing or attachment for the IBC 803.13 column wrap(must also be HANGERS CALLED OUT ON A-0.25 TO BE IN COMPLIANCE WITH IBC 803.13 non-combustible) III; Subject: PlanCheck si Page Label: 10 Remove the 30"x48"clearance Author:justinh shown over the toilet N Remove the30"x48" IAAa � File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf clearance shown over - /h Color: • •r the toilet 1I` I lj. II t �� I IiM REMOVED ON A-101 o• .6• _-; _. �9 Subject: PlanCheck �/ Door maneuvering clearance _1$ 0 % n :1-ii _ B Page Label: 10 o�Q���F�,°" " O Author:justinh inside the restroom should be Nems!! o * °= "wee'" File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf shown as front approach, push ���;,\ ° �a ' I Color: • side per figure 404.2.3.2 in ICC `_L_ j ___ ����; m A117.1 (48"deep full width of il door, extending 12"beyond latch — ,__is O if closer is provided). j�-a,_°_ q�,I DOOR MANEUVERING CLEARANCE IS SHOWN AS FRONT APPROACH, PUSH SIDE ON A-101 v ® . �. Subject: PlanCheck � Dimension the clear width of all �,S,_4u . t , -- Page Label: 10 l ! /•�� =' ' Author:justinh doors from jamb to face of door igugait sN �, CI _` ®LI File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf open at 90(32" min req'd) 141, ' �. ,a,, -rj�'I__ � Color: ■ . •�,;' \Ilililllllllllll ALL NEW DOORS DIMENSIONED ON A-101 m 0 ® b o 0 o bo — — Subject: PlanCheck I,. Page Label: 10 4 Dimension center line of sink to Author:justinh adjacent wall (15"min) �_ accessible approach should be °f ai"kt°a";eest ' File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf (15'minJ accessible °a°nab°°i"ba centered on fixture in the Color: • a°°°a3aibia accessible restroom. 3otT.Nei * DIMENSION ADDED TO SINK ON A-101 a,1 M' - _ ,, 1 n., Subject: PlanCheck ��, C ©i�i Page Label: 10 Dimension center line of sink to '88 °°E �� Author:justinh wall (15" min)and centerline sink I� ii •iiii File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf to centerline urinal (30" min). Qaa„� it mA- Color: ■ rt r�1=;....ilismozriwom I oisek oo (IF ime or sink to wall(Is^ THESE DIMENSIONS ARE ADDED TO A-101 si k to centerline a"nal 30'min. aril - Subject: PlanCheck lam.■ 21j!II Pa a Label: 10 Dimension your handrail "= 1 = �'�r__ g extensions (one tread depth `�lI Author:justinh !' File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf min.), note handrail height - II !a 1\�IllhilllllllNEp Color: • (34-38"), and identify shape/size ' �'� to show compliance with IBC 1014 for graspability 3o-30a, da i" '"' /� //�� a° •°� �_ HANDRAIL EXT. DIMENSIONED ON A-101. HANDRAIL HEIGHT/SHAPE/SIZE ON SHEET A-0.25 121 12.51 3 r41 3 . mp„m ;�„> Subject: PlanCheck Tables with seats back to back "iiiuji�aar! page Label: 10 V— — should be a minimum of 38" 14■ ■.--- Author:justinh `u E apart(19"clearance for seating etrftKn'n� 0 i File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf 4.477, n''::1 ee € per IBC 1029.12.1 x 2). This mo�38 �= Color: • ;; a,acea,°rt ,...,_ ov , — only scales at 35". allriI g TABLE LAYOUT HAS BEEN CHANGED AND DIMS ADDED TO A-101 EREIMUL i�, T T - Subject: PlanCheck Page Label: 10 I believe you need an aisle Author:justinh accessway of 12" plus the 38" " °� - - File Name: 90.ARCHITECTURAL PLANS. 20230201.pdf width for back to back seats per . INE: Ipl- Color: • IBC 1029.12.1 and 1029.12.1.1 i�i�i� ..�.�� ;�. ��. �m for compliant egress to all bar '�i � i r, seating because it can only be it aiT.i� e< ��`��� accessed from either side with ' � 'o�h TABLE LAYOUT HAS BEEN CHANGED AND DIMS the existingcolumn location I'r � l gt ""e= '1 ''t ADDED TO A-101 ! //A N =_1_- 1 __= ot% , between the closest tables. See "rn" commentary to IBC 1029.12.1 for figure that will hopefully help explain this. Revise as needed. 90. MEP PLANS. 20230201.pdf(4) Subject: PlanCheck 4 mn"ff.n Page Label: [1] 22338-508 E COOPER-MECH-MO-1 Revise all code references to be p.".m"�" ••"°m"" Author:justinh the 2015 International code - °•-�• °•�«"" % File Name: 90. MEP PLANS. 20230201.pdf editions Color: ■ BCE Response: Plan code references have been updated to show 2015 codes. �= - °n� -WF•« �" •F-"•w See attached plans. ;ROVIDE WITH HANGERS,FLEXIBLE DUCT CONNECTIONS, Subject: PlanCheck Page Label: [4] 22338-508 E COOPER- MECH-M3-1 Provide a mechanical Author:justinh ComCheck File Name: 90. MEP PLANS. 20230201.pdf Color: ■ Provide a mechanical ComCheck BCE Response: Refer to attached PDF for ComCheck. NFORMATION Subject: PlanCheck _ Page Label: [5] 22338-508 E COOPER-MECH-M3-2 What is supplying the 1050 cfm '" "°'l Author:justinh OA to the restaurant shown on - �« File Name: 90. MEP PLANS. 20230201.pdf the balance calc? Not finding "` �- that on the plan or schedules, Color: ■ please clarify. -- 774-7 BCE Response: 5n Outside air provided existing supply duct from the roof. oo.AmE oo.A Subject: PlanCheck Page Label: [5] 22338-508 E COOPER-MECH-M3-2 Kitchen area to be exhausted FaEs aRoEOFaoM'a° Author:justinh should be 100 sq.ft. larger to File Name: 90. MEP PLANS. 20230201.pdf account for the un-vented "�narearoa m.atln;R; '°°� Color: • dishwasher at the bar per IMC oo ?=aq 507.3 to demonstrate the heat and moisture is properly being accounted for in the HVAC design. BCE Response: Ventilation calculations updated to show kitchen area 100ft2 larger.