IGREENHECK Cut Sheet - Not for Submittal ® Printed Date: 01/31/2023 Building Value in Air. Mark: EF-1 Model: USGF-180-10 Model: USGF-180-10 035.38 — Ultimate Steel Grease Fan A 28.63 Dimensional 21.00 Quantity 1 [3.30 Weight w/o Acc's(Ib) 286 —... .� Weight w/Acc's(Ib) 304 f Max T Motor Frame Size 184 29.00 SQ Standard Curb Cap Size(in.) 30 x 30 Roof Opening(in.) 20.5 x 20.5 Performance OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. Requested Volume(CFM) 3,000 Actual Volume(CFM) 3,000 1.6 1.2 Total External SP(in.wg) 1.065 — Fan RPM 1229 1229 FRPM -----------, _ Operating Power(hp) 0.96 '� 1.2 0.9 Elevation(ft) 4,839 Airstream Temp.(F) 90 Air Density(Ib/ft3) 0.060 — r Drive Loss(%) 6.3 0.8 0.645 Tip Speed(ft/min) 5,952 w am — 0_0 Static Eff.(%) 56 a bao 0 mISc Fan uata 0 — m co Fan Eff. Index(FEI) 1.32 ul 0.4 •c 0.3 Outlet Velocity(ft/min) 1,027 oQo� e�" O — 0.0 - - - 1 1 1 IIII IIII IIII IIII IIII I IIII III 0.0 Motor 0 5 10 15 20 25 30 35 40 45 50 Motor Mounted Yes Volume (CFM)x 100 Size(hp) 1 Voltage/Cycle/Phase 208/60/3 L Operating Bhp point Enclosure ODP 0 Operating point at Total External SP Fan curve Motor RPM 1725 - - System curve Efficiency Rating Standard Brake horsepower curve Windings 1 NEC FLA*(Amps) 4.6 Min.Circuit Ampacity(MCA) 5.75 Notes: Max.Overcurrent Protection(MOP) 15 All dimensions shown are in units of in. *NEC FLA,MCA and MOP are for reference only—based on Short Circuit Current Rtg(SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020.Actual motor FLA may vary,for sizing thermal overload,consult factory. MCA and MOP values shown only account for the motor,not QfT1CQ accessories(damper actuator,field supplied VFD,etc). moatowioc Sound Power byOctave Band LwA-A weighted sound power level,based on ANSI S1.4 Re OcrfD dBA-A weighted sound pressure level,based on 11.5 dB Sound attenuation per Octave band at 5 ft-dBA levels are not licensed OUOD 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCA International I - ,l1..! I.' Data Sones-calculated using ANSI/AMCA 301 at 5 ft i ,� 441K I!sai.• L J Inlet 77 80 83 74 69 68 64 59 78 67 15.5 The motor provided on this fan is inverter ready and meets NEti'1A ' . ' MG1 Part 31.4.4.2 '! � 03 ..�•--- 23 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com AJ- ?of 19 L_ BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: EF-1 Model: USGF-180-10 Model: USGF-180-10 Ultimate Steel Grease Fan Standard Construction Features: -Entire unit is constructed of steel and powder coated-Backward inclined steel wheel coated with Non-Stick Coating-UL Listed for grease applications-Curb cap with prepunched mounting holes-Motor and drives isolated on flange safety shock mounts-Drain trough-Ball bearing motors-Adjustable motor pulley- Dual drive belt and pulley system-Adjustable motor plate-Fan shaft mounted in ball bearing pillow blocks-Bearings meet or exceed temperature rating of fan- Static resistant belts-Corrosion resistant fasteners-Internal lifting lugs Selected Options &Accessories: Motor VFD Rated without Shaft Grounding Protection Motor with Thermal Overload Provided motor meets the motor efficiency requirements set forth in ANSI/ ASHRAE/IES Standard 90.1 Standard Curb Cap Size-30 Square UL/cUL 762 Listed-"Power Ventilators for Rest. Exh.Appliances" Switch, NEMA-3R,Toggle,Shipped with Unit Junction Box Mounted&Wired Hinged Base(Attached) High Temp Curb Seal Rated for Continuous Duty at 1500 F(Factory Attached) Coated with Permatector,Concrete Gray-RAL 7023, Fan And Attached Acc Non-Stick Coated Wheel(Teflon) Grease Trap(PN 475538) Heat Baffle(Attached) Bearings with Grease Fittings, L10 life of 100,000 hrs(L50 avg.life 500,000 hrs) Clean-out Port-Factory Installed Unit Warranty: 1 Yr(Standard) RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com AP-, - of 19 L BUILDING DEPARTMENT � AlGREEHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: EF-1 Model: USGF-180-10 AMCA amcca WORLDWIDE CERTIFIED RATIAGS sounD AIR PERTORMMICE FEI AIR full EOEIIGY IIIDEX AIOVEAIEAT AAD COATROI •A�c A5SOCIATIOA 0 o4 IATERAATIOAAI. LAC.° AMCA Licensed for Sound and Air Performance and FEI ratings. Power rating (BHP/kW) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA certified ratings seal applies to sound and air performance and FEI ratings only. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) includes transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per ANSI/ AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com Agtitpf 19 L BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: M UA-1 Model: DGX-P114-H12 DGX-P 114-H 12 Unit Performance Design Conditions Summer Min Supply Outdoor Air Elevation (ft) DB(°F) WB(°F) Winter(°F) Supply(CFM) (CFM) Airflow (CFM) 4,839 97.4 65.5 6.0 2,400 2,400 840 Unit Specifications Qty Weight(lb) Cooling Type Heating Type Unit Installation Unit ETL Listing 1 956(+/-5%) Direct Evaporative Direct Gas-Fired Outdoor/Indoor ANSI Z83.4/CSA 3.7 Configuration Unit Orientation Unit Configuration Outdoor Air Intake Return Air Intake Supply Air Discharge Horizontal Variable Volume End - End Cooling Specifications Type Cooling Media Media Required Performance(DB/WB) Depth(in.) Flow(GPM) EAT(°F) LAT(°F) Direct Evaporative GLASdek 12 0.3 97.4/65.5 68.6/65.5 Heating Specifications Gas Pressure Capacity(MBH) Performance Type Gas Type Min Max Temperature(in.wg) (Psi) Input Output Rise(°F) EAT(°F) LAT(°F) Direct Gas Natural 7 0.5 150.9 138.8 64.0 6.0 70.0 Air Performance Total External SP Total SP Operating Fan Type Volume (in.wg) (in.wg) RPM (CFM) Power(hp) Qty Type Size(in.) Drive-Type Supply 2,400 1.02 2.026 2536 1.35 1 Plenum 14 Direct-Drive Motor Specifications Motor Qty Size(HP) Enclosure Efficiency RPM Supply Fan Motor 1 2 ODP NEMA Premium 1725 Electrical Specifications Power Supply Rating (V/C/P) MCA(A) MOP(A) SCCR Unit 208/60/3 11.3 15 5kA `NZERrfi� C US LISTED RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com ARagt4 of 19 J � BUILDING DEPARTMENT ®GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 CONSTRUCTION FEATURES AND ACCESSORIES Unit Accessories Unit Installation-Outdoor Std Factory Installed, Lockable, NEMA 3R Disconnect Std Unit Construction-Double Wall X Weatherhood-Louvered with aluminum mesh filters X Wall Insulation- 1 in.fiberglass-Tempering on X Supply Air Filters-2" MERV 8, 16x20x2-(4) X Base Insulation- 1 in.fiberglass-entire unit base pan Std Outdoor Air Inlet Damper Paneled Bottom-Sheet metal liner for base insulation Supply Air Outlet Damper Corrosion Resistant Fasteners Std Return Air Damper Access and Connections-Right side when facing intake X Diffuser Service Access-Hinged access doors X Roof Curb Unit Finish-G90 Galvanized X Combination Curb Finish Color Electrofin Coil Coating Supply Fan-Direct-drive, backward-curved plenum X Fan Bearing Extended Lube Lines Supply Fan and Motor Vibration isolation-Neoprene X Inlet Damper Module Controls Spare Belts Unit Controls-Terminal strip X Spare Filters Remote Panel Motor with Shaft Grounding BMS Communication Service Outlet-Shipped loose X BMS Protocol Service Lights Temperature Control-Discharge control X Gas Heating Accessories Supply Fan VFD-VFD by factory X Pilot Ignition Std Supply Fan Control- External 0-10 VDC signal X Flame Sensing-Flame rod X Unoccupied Mode(Night Setback) Flame Safeguard Display Control Accessories Agency Approval-ETL Std Remote display FM Compliant X_ Heating Inlet Air Sensor X High Gas Pressure Switch Cooling Inlet Air Sensor X Low Gas Pressure Switch Dirty Filter Switch Visual Indication Valves Fire Stat Type III (Ships loose) Proof of Closure Valve 120V/24V Smoke Detector(Ships loose) External Gas Pressure Regulator(Ships loose) Inlet Damper End Switch Carbon Dioxide Sensor(Ships loose) External Cooling Lockout Relay Evaporative Cooling Accessories Freeze Protection (Supply Air Low Limit) Evap Controls- Recirculating Pump X Auxiliary Supply Starter Contacts Evap Valves(Ship loose) Auxiliary Exhaust Starter Contacts Louvered intake provided with 2"aluminum mesh filters X Airflow Proving Monitoring Contact Warranty Options Unit Warranty- 18 months(std.) X 5 Year Compressor Warranty 5 Year Burner Warranty 10 Year Burner Warranty Standard Option Std Not Included Included X RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com Agist of 19 BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: M UA-1 Model: DGX-P114-H12 Fan Charts And Performance Supply Fan Performance Total Volume External SP Total SP Operating Motor Fan (CFM) (in.wg) (in.wg) RPM Power(hp) Qty (HP) Qty Type Drive-Type 2,400 1.02 2.026 2536 1.35 1 2 1 Plenum Direct Pressure Drop(in.wg) Diffuser Weatherhood Filter Damper Cooling Heating External Total - - - 0.381 0.625 1.02 2.026 Sound Performance in Accordance with AMCA Sound Power by Octave Band Lwa dBA Sones 62.5 I 125 250 500 1000 12000 4000 8000 62 62 74 83 84 81 78 71 88 77 30 Supply Fan 4.0 2.4 3.5 SgsFR', •! 2.1 3.0 1.8 • • • 3 2.5 1.5 ------------------ — �_` — 22.0 a -; Ay — 1.2 3 m o a — a 2• 1.5 y 0.9 o a Y m • O 1.0 �m 0.6 an 0 • c° • 0.5 0.3 0.0 1_.1_..E- -1-..1 1 1 1 1 1 1 I I I I I I I I I I I I 1 1 1 0.0 0 5 10 15 20 25 30 35 Volume(CFM)x 100 L Operating Bhp point O Operating point at Total External TP Fan curve ----..- System curve Brake horsepower curve RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com AP-,agt_kof 19 BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: M UA-1 Model: DGX-P114-H12 Cooling Specifications Cooling Performance Type Cooling Media Media Required Performance(DB/WB) Depth (in.) Flow(GPM) EAT(°F) LAT(°F) Direct Evaporative GLASdek 12 0.3 97.4/65.5 68.6/65.5 Unit Details Stainless steel sump and media casing Ball valve for flow rate adjustment Supply line, drain line and supply line drain valves must be field Recirculating pump(s)provided by factory provided by others Valve provided for bleed-off rate adjustment Recirc. Pump Evap Control Supply Line NA Field-Supplied Field-Supplied Supply Line Valve Drain Line Valve Drain Line �` v_____Overflow� �P� U - Evaporative Cooling Connections LOUVERED INTAKE 9 1l I SUPPLY CONNECTION FIELD LOCATED a a 3/4" NPT OVERFLOW I 3/4" NPT DRAIN p 1 rc ,�: l ��� 11.592 �g .I 5.748 7.i79 3.503 t MERV 8 FILTER RECEIVED " ALUMINUM FILTER 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com A§19tr pf 19 BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: M UA-1 Model: DGX-P114-H12 Heating Specifications Heating Performance Gas Pressure Capacity(MBH) Performance Type Gas Type Min Max Temperature(in.wg) (Psi) Input Output Rise(°F) EAT(°F) LAT(oF) Direct Gas Natural 7 0.5 150.9 138.8 64.0 6.0 70.0 Gas Train Details Redundant Electronic Internal Visual Proof of Gas Pressure External Main Modulating Pilot Valve Regulator Indication Closure Valve Switch(es) Regulator Valves Valve Valve Std Std Std Std - - - - Additional Heating Information ETL Approved FM Compliant Temperature Flame Sensing Ignition Control CO2 Sensor Flame Safeguard Control Display Std Yes Discharge Flame Rod Economy Pilot - - Unit Details 92%thermal efficiency 10 second pre-purge sequence Cast aluminum burner manifold with stainless steel mixing plates Low fire start Electronic modulation burner control Gas Connections i r 2.000 C 4O 15.000 HN_ ELECTRICAL CONNECTION 3/4"NPT GAS CONNECTION 10.250 2.250 — RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com ARagt8 of 19 J � BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 ELEVATION VIEW 102.902 40.244 -- 37.596 H 25.062 i LOUVERED INTAKE 1 .../ • • ,/, c4 38.963 0 / \ s I.-.o C G O_ 1 -"MERV 8 FILTER "ALUMINUM FILTER Notes-Elevation View Standard configuration for unit access is on the right-hand side, when looking into the unit intake in the direction of airflow. Order of unit sections is from intake of unit to discharge of unit. Sections included on this unit: Cooling Section, Heating Section, Blower Section Insulation: Double Wall,from Burner Section through end of unit. PLAN VIEW ACCESS SIDE BURNER PLENUM EVAP COOLING BLOWER h-mill 40.244 -j- 37.596 --h- 25.062 -1 I Ar- ill W� ) --I 33.656 I' / _ 1 ACCESS SIDE ACCESS SIDE ACCESS SIDE CONTROL CENTER Notes -Plan View Standard configuration for unit access is on the right-hand side,when looking into the unit intake in the direction of airfiRw.i, NI fl <,; 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com APttJF'Llof 19 BUILDING DEPARTMENT ESIGREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 END VIEW 33.086 5.25 22.50 5.75 1 SUPPLY 22.50 DUCT 38.963 FOOTPRINT VIEW 59.750 CURB LENGTH RECOMMENDED • • • 29.500 CURB WIDTH RECOMMENDED • • • • Notes-Footprint View Minimum Roof Opening: The minimum roof opening size is the illustrated duct diameter plus 0.25 in. on all sides. For example: If the duct size is 14 x 14 in. square, the minimum roof opening size is 14.5 x 14.5 in. square. Maximum Roof Opening: There must be a minimum perimeter of 1.75 in. between the roof opening and the roof curb. For example: If the roof curb is 75 x 30 in. square,the maximum roof opening is 71.5 x 26.5 in. inches square. The weatherhood and filter sections of the make-up air unit extend beyond the curb. This is by design,to prevent water infiltration. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com Page,1 Q of 19 BUILDING DEPARTMENT IGREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 INTAKE VIEW r 1.049 12.090 1 31.960 40.022 II III\ � t r 4.124 �- 33.195 -� RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com P�1geL1 of 19 BUILDING DEPARTMENT L-151GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 Clearance Specifications Recommended Minimum Combustible Clearances Floor(in.) Top(in.) Sides(in.) Ends(in.) Insulated Units 0 0 0 0 Non-Insulated Units 0 6 6 6 Notes -Combustible Clearances Clearance to combustibles is defined as the minimum distance required between the heating source and the adjacent combustible surfaces to ensure the adjacent surface's temperature does not exceed 90 F above the ambient temperature. Recommended Minimum Service Clearances Housing 32 and less (in.) Housing 35 and higher(in.) 42 on the controls side of the unit 48 on the controls side of the unit Notes -Service Clearances To ensure ample space for component removal (evaporative cooling media, coils,filters, etc.), service clearances should be 6 in.wider than the width of the module itself. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f�,Pr�2 of 19 LTV BUILDING DEPARTMENT ®GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 Wiring Diagram OSI "SPOS 1-LC ro_�L3®TTi® fflGREENHECK GSOBV -- Building Value in Air. SUPPLY FAN u m m MOTOR Wir'Im ® wNTROL suRPLr vnN F)I-) ^Dla0ram Cna.: GD61 N401 F301A30NM24 CAUTION NIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. I En RC tt5v� POWER MUST BE OFF WHILE SERVICINOTESrvc. 1111 EV PUMP E- 1, E USE FOR COPPER RATED LESS THAN 100 AMP TERMINALS RATED 100 AMPS OR MORE C FOR TER FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 0.75 OHM FIELD WIRED • FACTORY SUPPLIED AND WIRED ' WIRE COLOR CODE ® ® BK BLACK BL BLUE BR BROWN GT GRAY LT BL LIGHT BLUE 0 ORANGE PK PINK PR PURPLE R RED © w WHITE V YELLOW LEGEND 7 El AMP AMPLIFIER A FDSI MAIN DISCONNECT Sc FIRE SYSTEM CONTACT CH FSG FLAME SAFE GUARD FM FUSE HLC HIGH LIMIT CONTROL 316 MOTOR MOD MODULATING -S.2 I--X- 0 PINKMB MC • •�gp12q SUPPLY FAN RELAY WITH RF C COOL RE. SUPPLY FAN RELAY RH HEAT RELAY 0 FAN SWITCH S4 HEAT AND COOL SWITCH SG SPARK GENERATOR IMACHS=111 SENSOR TSLOWER 4 INLET AIR DIFFERENTIAL LEAT =2 TSE I SENSOR-HEAT _N DIFFERENTIAL= OFFSET=10 VI PILOT VALVE V2 MAIN VALVE VFD VARIABLE FREQUENCY DRIVE —�� coM.• THERMOSTAT CONTROLLER(S) ▪ ©pro 21� N0 poHERMOSTATS TS<,T53a,®A POST HEAT 30�OFF RF iv.,. TSS ▪ 0 •,• 311134 coM No A, cow. 1 Rl a®rHL1rp - C P�NO NC PSP C wo m DIRECT GAS CONTROL Maaja •SENSE THl24V• •ALM FSG (BURNER)• m •SPARK Pv• (24vi• I® 10 SEC AMPDISCHARGE STAT %RANGE To 0 pW AC 0 0 3 0 0 B 00 WINO T.NPIM•.M24 DOC NUMBER:— REV:— Manufacturer reserves the right to change, modify, or improve this product at anytime RE�'E�VEt� 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com P 1 of 19 BUILDING DEPARTMENT OGREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 Dry Corner Weights 751b 701b 130 lb 160 lb Evap Module Unit 701b 661b 135 lb 166 lb Wet Corner Weights 981b 991b 130 lb 160 lb Evap Module Unit 921b 931b 135 lb 166 lb Notes Estimated corner weights are shown looking down on unit and airflow from left to right. Weights are applied at the base of the unit. Evaporative cooling section shown separately due to calculation of dry and wet corner weights. Images not drawn to scale. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f�,P ��of 19 L BUILDING DEPARTMENT 351 AlGREEHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: M UA-1 Model: DGX-P114-H12 SEQUENCE OF OPERATIONS Unit Controls The unit shall be provided from the factory with: • 24VAC Transformer • Terminal Strip • Supply fan VFD Field Provided Control Requirements The following field provided control signals must be provided for proper operation of the unit (Reference the unit wiring diagram for additional information): • Supply fan enable—Contact closure between R and G (24VAC) • Cooling enable—Contact closure between R and Y1 (24VAC)*Factory installed jumper allows heating to be enabled automatically by outside air temperature- remove jumper for field provided control. • Supply fan VFD speed signal —0-10 VDC Unit Start-Up Sequence • Supply Fan Enable Is Received • Supply Fan Is Enabled Supply Fan Sequence The unit has been provided with a factory mounted variable frequency drive (VFD). The variable frequency drive shall control the supply fan speed as indicated by the following sequence: External 0-10 VDC Signal By Others: The supply fan speed is modulated by an external 0-10 VDC signal (field provided and wired) landed to terminals in the unit control center(see unit wiring diagram for details). Heating Control A heating enable signal must be present and the supply fan must enabled before the unit will enable heating. Heating Inlet Air Sensor(Heating Lockout) The heating will be locked out when the outside air temperature is above the heating inlet air sensor set point (typical 65 F, adj.) Direct Gas Fired Heating (Discharge Control) The gas control amplifier located in the unit shall modulate the heating to maintain a supply temperature set point (55 F-90 F, adj.). • The set point is adjusted in the unit control center. Cooling Control A cooling enable signal must be present and the supply fan must be enabled before the unit will enable cooling. Cooling Inlet Air Sensor(Cooling Lockout) The cooling will be locked out when the outside air temperature is below the cooling inlet air sensor set point (typical 80 F, adj.) Evaporative Cooling (Recirculating Pump) When cooling is enabled the pump recirculates water from the sump over the evaporative cooling media and a float valve maintains the water level in the sump. Supply and drain valves must be field supplied and installed. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f� LTV fzri of 19 BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: MUA-1 Model: DGX-P114-H12 Warranty Statement for Make-Up Air Unit Warranty Greenheck warrants the equipment to be free from defects in material and workmanship for a period of 18 months from the date of shipment. Initial startup must be completed within six months of the shipment date, and a startup report must be submitted to Greenheck. DG Burner Extended Warranty The warranty does not include items deemed as consumable components, including, but not limited to: Igniters, Spark rods, Spark generator, Flame rods,Flame wires, UV eye components, and associated components. Note: Rust, discoloration of the burner material and cracks or holes smaller than .75 in. is not qualification for a defective burner. Warranty Notes Any component which proves defective during the warranty period will be repaired or replaced at Greenheck's sole option when returned to our factory, transportation prepaid. All warranties do not include labor costs associated with troubleshooting, removal, or installation. Greenheck will not be liable for any consequential, punitive, or incidental damages resulting from use, repair, or operation of any Greenheck product.These warranties are exclusive and are in lieu of all other warranties,whether written, oral, or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. No person (including any agent or salesperson)has authority to expand Seller's obligation beyond the terms of this warranty, or to state that the performance of the product is other than that published by Seller. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. RECEIVED Tempered Air Products(TAP) Statement 2018 0 3/10/2 0 2 3 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f�,Pr�6 of 19 LTV BUILDING DEPARTMENT IGREENHECK Cut Sheet - Not for Submittal ® Printed Date: 01/31/2023 Building Value in Air. Mark: EF-2 Model: CUE-099-VG Model: CUE-099-VG Direct Drive Upblast Centrifugal Roof Exhaust Fan 28.25 Dimensional 16.50 Quantity 1 1 3.30 Weight w/o Acc's(Ib) 38 d 01 Weight w/Acc's(Ib) 53 1I1 t Standard Curb Cap Size(in.) 19 x 19 Roof Opening(in.) 15.5 x 15.5 —19.00 SQ Performance OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. Requested Volume(CFM) 700 Actual Volume(CFM) 700 1.2 0.8 Total External SP(in.wg) 0.75 Fan RPM 1619 Operating Power(hp) 0.17 0 9 1 _FRPM 0.6 Elevation(ft) 4,839 • Airstream Temp.(F) 70 c 0 Air Density(Ib/ft3) 0.063 — Tip Speed(ft/min) 4,742 a) 0.6 0.4 `m Static Eff.(%) 49 Co a — o El -a 0 h — a> Misc Fan Data a s — u m Fan Eff. Index(FEI) - g 0.3 4° 0.2 0 Outlet Velocity(ft/min) 547 o — e 0.0 .4.— I".. I I I III Ill III III Ill 0.0 Motor 0 2 4 6 8 10 12 14 Motor Mounted Yes Volume (CFM)x 100 Size(hp) 1/4 Voltage/Cycle/Phase 208/60/1 L Operating Bhp point Enclosure TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 - - - -System curve Efficiency Rating High Brake horsepower curve Windings 1 FLA(Amps) 1.7 Min.Circuit Ampacity(MCA) 2 Notes: All dimensions shown are in units of in. Max.Overcurrent Protection(MOP) 15 *NEC FLA,MCA and MOP are for reference only—based on Short Circuit Current Rtg(SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020.Actual motor FLA may vary,for sizing thermal overload,consult factory. QmCQ MCA and MOP values shown only account for the motor,not aniClaWORIDWIDE accessories(damper actuator,field supplied VFD,etc). CERTIFIED Sound Power byOctave Band LwA-A weighted sound power level,based on ANSI S1.4 RRTIRGS dBA-A weighted sound pressure level,based on 11.5 dB Sound attenuation per Octave band at 5 ft-dBA levels are not licensed A� Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCAlnternational Sones-calculated using ANSI/AMCA 301 at 5 ft R �����` Inlet 75 72 73 68 63 63 58 50 71 59 9.6 nin m nvmm�n e n ccn•on °ago 0 n Wont _ 3 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com P,agagof 19 BUILDING DEPARTMENT �GREENHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: EF-2 Model: CUE-099-VG Model: CUE-099-VG Direct Drive Upblast Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined aluminum wheel-Aluminum curb cap with prepunched mounting holes-Drain trough-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing Standard Curb Cap Size-19 Square UL/cUL 762 Listed-"Power Ventilators for Rest. Exh.Appliances" Switch, NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Hinge, Factory Installed High Temp Curb Seal Rated for Continuous Duty at 1500 F(Factory Attached) Grease Trap(PN 475538) Unit Warranty: 1 Yr(Standard) The Vari-Green Motor included in this order has a'Multi-Voltage'ability. The red wire on the motor is called a`Voltage Doubler',and when it is connected the motor can be powered by 115V. If the Red wire is disconnected,then the motor can be powered with 208-230/277V. The motor will leave the factory with the voltage doubler wired per the order. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f�,PCBN of 19 Ll BUILDING DEPARTMENT AlEGREEHECK Cut Sheet - Not for Submittal Printed Date: 01/31/2023 Building Value in Air. Mark: EF-2 Model: CUE-099-VG AMCA amcca WORLDWIDE CERTIFIED RRTIRGS soune CIAD AIR FERrORAIAACE AIR kid AIOVEAIEAT 4 AAD COATROI •A�c A5SOCIATIOA 404 IATERAATIOAAI. LAC. '5' 9 AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per ANSI/AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. RECEIVED 03/10/2023 C:\Users\Greg\Documents\CAPS\Jobs\508 E Cooper.gfcj CAPS 4.39.1057 Generated by:greg@bighorneng.com f�,PCB of 19 LTV BUILDING DEPARTMENT