Loading...
HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0003-2023-BRES (7) APPLICATION ACCEPTED DATE: 2023-01-12 PERMIT NUMBER: 0003-2023-BRES Field Plan Set Must Be Printed In Color ,`ik1 didgl r COMMUNITY DEVELOPMENT DEPARTMENT CITY OF ASPENuu BUILDING PERMIT COVERSHEET 1�l►`I►( ASPEN PERMIT CITY 4F ASPEN NO, 0003-2023-BRES These plans ms eKeept at the building site or inspection delays may occur.Construction PROPERTY INFORMATION shall conform to these plans.All OWNERI M & AY LLC changes shall be approved by ADDRESS: 205 E DURANT AVE 1G UNIT: , lifiliging official. PARCEL ID: 273513109014 LEGAL DESCRIPTION: SOUTH POINT ' OWNER: IM&AY LLC PERMIT CONTRACTOR: ADDRESS SEPARATE PERMITS ARE 205 E Durant, #1G REQPRATEPEELECTRICAL, E PLUMBING,MECHANICAL,OR • FIRE SPRINKLER WORK DESCRIPTION OF WORK Kitchen Remodel 27351 31 0901 4 SMOKE ALARMS AND pARcELID CARBON MONOXIDE Change location of restroom doors to non-load bearing walls _—_ .��.. , DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN Drywall MUNICIPAL CODE 8.15 Complete Ceiling Remodelling. - RESIDENTIAL REFERENCES FROM 2015C Dwelling Separation Required-2015 IBC CV/CS=crawl space ventilation sec.1203.4. 18"x 24"accesscess required -708 Fire Partitions,711 Horizontal Assemblies: 1209.1 ' - Walls and floor/ceilings separating dwelling units shall have a fire-resistance EE=emergency escape required sec 1030 It should be known that this review shall rating of at least 1 hour.Walls shall extend from the top of the floor assembly EU=enclosed usable space under stairs shall be 1-hr construction or stair not relieve the applicant of their below to the underside of the floor or roof slab or deck above or to the enclosure rating.No access from stair enclosure.'/gypsum permitted for responsibility to comply with the fire-resistance-rated floor/ceiling assembly above. stairs inside a single dwelling unit.1011.7.3. requirements of the City of Aspen -714:Penetrations must be protected by a through-penetration firestop RV=roof and rafter ventilation required 1203.2 system.Recessed fixtures shall not reduce the required fire resistance by use1Municipal Code.Pursuant to A=Atticsmoke Accessla2(x PA 72)required a listed fixture,a listed frehood,or a drywall assembly meeting the required SA=smoke alarm(NFPA 72)required sec 907.2.11 Sec.26.104.050,any permit or approval fire resistance.Exhaust fans require ceiling radiation damper. ssued in error or otherwise not in USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? Yes q 9 p COSG=carbone monoxideingeuredcser req.per Aspen Municipal Code 8.15 -1207 Sound Transmission:Separating walls and floor/ceilings shall have an SG=safety glazing required sec 2406 conformity with the requirements of this STC rating of at least 50.Floor/ceilings shall have an IIC rating of at least 50. V=mechanical ventilation required sec 1203.1&IMC 403(bath fans and Title,shall be void.Similarly,any permit • whole house ventilation) or approval issued in reliance upon or GR=guards,42"min ht,4"max opening.Guards within dwelling unit 36"min as a result of,a materially false CLASS OF WORK Residential FIRE SPRINKLER TYPE ht sec 1015 HR=handrails 34"-38"ht sec 1014 statement or representation made in FIRE DAMPERS REQUIRED FIRE RATED HATS REQUIRED DS=Draft stopping/fire blocking 718 the process of obtaining the permit or Where floor/ceiling or roof/ceiling RD=Roof drainage 1503.4 development approval shall,likewise, Ducts and air transfer openings in fire eveP PP dwelling at d 50 than not l l i i d t required to have a STC=Sound class ess weng separations,sec REQUIRED SPECIAL resistive floor/ceiling or root/ceiling assemblies are be void.Any person having received a BUILDING TYPE(IRC) fire-resistive rating,recessed fixtures shall 1207 assemblies shall be protected with approved void or voidable permit or approval INSPECTIONS fire dampers installed in accordance with b installed such that the required fire Si=Stairway Illumination shall not be relieved from havingto General Electrical Requirements their listing(IBC 717.5.2&717.5.4) resistance will not be reduced(IBC 714.4.2) PD=protect against decay,y,sec sec 2304.12 Any areas affected by the renovation must be brought REFERENCES FROM 2015 IMC comply with all applicable terms and DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM conditions of this Title and the City shall CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table up to the current electrical code including: AS=access and service space for maintenance req'd,sec 306 not be estopped from fully enforcing tamperproof receptacles(NEC 406.12), MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2 same. ground-fault circuit interrupter protection(NEC 210.8), CEILING RADIATION DAMPERS REQUIRED ET=exhausts terminate 3'from prop line and openings,10'from intakes, Ducts and air transfer openings penetrating the ceiling of 501.3.1 arc-fault protection(NEC 210.12), afire rated ceilingassembly must be protected with a IT=intake openings 10'from lot line&contaminant sources(vents,streets), WORK CHANGES BUILDING yREVisoirEW/16-0) OCCUPANCY GROUP(IBC) R-2 No receptacle spacing(NEC 210.52)etc. listed ceiling radiation damper.This includes bathroom 401.4 FOOTPRINT? exhaust fans.(IBC 717.6.2) D=fasten and seal all ductwork per 603.9REFERENCES FROM 2015 IFGC phlev DV=direct vent req'd,sec 303.3 01/12/2023 J CA=combustion air not taken from bedrooms,bathrooms or CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. storage sec 303.3 ZONING OD=outdoor appliances must be listed for outdoor use,sec 303.6 REFERENCES FROM 2015 IECC • F=new or replacement fenestration shall not exceed 0.28 U-factor,NFRC label required,Ordinance 40,2016 All interior remodel.No impact to exterior 2015 I E BC,2015 IMC,2015 IPC, L=75%of lampsin permanently Installed lights must be high efficacy,sec p OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. ; 'a' R4041 p y g g y mechanical systems,exterior lighting, 2020 NEC SE=Continuous air barrier required;all exterior joints,cracks,and holes to be exterior wall or roof penetrations. caulked,gasketed,sealed,table R402.4.1.1 REFERENCES FROM 2014 NEC HISTORIC PROPERTY? No TOTAL POOL SQ.FT. EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 riliEWE i")) City of Aspen September 12,2022FIRE SPRINKLER EXISTING? Yes Building Department 427 Rio Grande Place 06/2023 i Aspen,Colorado 81611 Re:Plan changes for 205 E.Durant,Unit 1G. READ THIS OR FAIL YOUR INSPECTION! FORCOMCOMKINICE limp Building department: Furred&Dropped Ceilings,Soffits,and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any Attached are the existing/new proposed plans for 205 E.Durant,Unit 1G.The project is a full assemblies that are required to be either fire-rated or remodel,demo to the studs.We are planning to remove a partition wall to enlarge the two non-combustible and is separate from the fire-rated bathrooms.The walls to be removed are non-load bearing,and do not contain any plumbing assembl requirement. lines.Please review plans and ring me with any questions. y Per Architect-Project scope modified: Walls,Ceilings&Soffits:If furred 1'/e inches or Sincerely, 1)Drywall only being demoed to less,do one of the following: iliailkY change doorways and bathrooms. 4.Fill spaces with Class A material. 2)Fireplace not changing. 5.Fill spaces with inorganic or non-combustible material. Kurt Carruth,Architect i1403049 3)Electric panel not moving. 6.Fire block 8 feet in all directions. hixgeARCHITECTS 4)mechanical closet not changing. 812 grand ave,ste.201 gws,co.81601 Walls:If set out(furred)greater than 1%inches, www.hinqe-architects.com do one of the following: 4.Use a Class A finish material(such as drywall). 5.Use non-combustible framing. C pF Cpte9,9 6.Protect both sides with fire sprinklers. a aUP r L. 0 W RUH Ceilings&Soffits:If dropped(furred)greater ?,\"jt,_=/F' than 1%inches: 'Ea A' Framing members,hangers,and other assembly members must be non-combustible.You may not use wood. In Type III and V construction only,you may use fire retardant treated wood or non-combustible framing. IlkRECEIVED )111 u���, J60 01/05/2023 /__ ,,_ ASPEN „w,„v.•,,,, _,... BUILDINGDEPARTMENT a Re ,ed z3'-5" 0/h imawn H ill 111 ILM I1ki l• MANTEL IIII IIII , sii OV2. , Oib rm p added 7 .,,.,,., ..�-- = a KIT LIVIN ROOM �L ]_ Cityof Aspen September 12,2022 ® 'e'e" P P � ft walkway ry� • KITCHEN Building Department both bat ' 427 Rio Grande Place E.T. ® o� Aspen,Colorado 81611 P'TIO LIVING ROOM _ O [ JJ Re.Plan changes for 205 E.Durant,Unit 1G. '� PEA e�FeOAPDHEpFp 1 MECH. CLOSET ._PATIO 1 „�N L �. EnTRv 9 �� �_ � 00 1411 c "'+' mm . ECH. CLOSET mBuilding department: e MBEDROOM ® "'Attached are the existing/new proposed plans for 205 E.Durant,Unit 1G.The project is a full C' BEDROOM "° 10_ N� Ii�_ remodel,demo to the studs.We are planning to remove a partition wall to enlarge the two - s\ /\. - BA al 0• Fr bathrooms.The walls to be removed are non-load bearing,and do not contain any plumbing �� •• - lines.Please review plans and ring me with any questions. T= CLOSET " M5 h• -" u ® ��1�1 CLOSET (_ `i� Sincerely, s's 3 4'-10" "'` 5 6 Ec 1,e �� S 0' ,, 5 Y 3'.1 4 im Y Per architect-Project scope modified. II �� I _ l y �_ 1)Drywall only being demoed to change �'l doorways and bathrooms. ®m - LINEN .. Kurt Carruth,Architect#403049 2)Fireplace not changing. LINEN �� hingeARCHITECTS 3)Electric panel not moving. I o BEDROOM : BEDROOM 812 grand ave,ste.201 1 `' gws,co.81601 II u D I�t4Nf1� 6 P r��mt www.hinge-architects.com \ 205 E.DURANT,APT.1G r r5mut'.VVL s-o^ s'r NovP oPm. n i. 205 E. DURANT, APT. 1G mnznaz3 CLOSET ASPEN,CO.81611 O f. 01/12/2023 U ZONING FLOOR PLAN SCALE 3/8'=T-0 ZONING ti�OF COL099 �I= CLOSET ASPEN, CO. 81611 O EXISTING y Kther UM $ FLOOR PLAN SCALE:3/8"=1'-0" -_ W/�l,(,S f' ' RECEIVED �Y V MEGA' r W GO p 01/05/2023 oz, /- 5 23 � ASPEN o,3D S=."'"_ ASPEN DEPARTMENT A BUILDING DEPARTMENT p TG11la n Z UU RECEIVED ZONING 01/05/2023 RO0 ASPEN BUILDING DEPARTMENT 28'-11" 1C-11" 3' FIREPLACE Y 5-8" l 160, 1 a- ,12"MANTEL - .- Living Area I. U•x I _ II 1. I lam_I 28'11"x 13'78 iii ■E 5 • -11 L� I.000' — 1. iil O O O lectric •-.nel ,:T 0 n �'' '0 0 0 Ia< -- I _ I —, a Q �_ Guest oo Ls.o" tem R st•om I oat Room ' I ' Bedroom _ 0'10z" 50 x10'!." / 0� II , 111 flr�lji !I!I !I! S -4 �i o� - echanical Room with • III -. 11 III ��� �r� On Demand Hot Water .q• ❑- -❑ ►, 1.p; WPM War and Bailer. ❑ i ❑ _Ox ❑ ►/ J 1 1 5' 5' �� I llla Bedroom I H1Vlt�1 ,., • 205 E.DURANT,APT.1G 11 11'1"x 13'5" ASPEN,CO.81611 __ FLOOR PLAN PROPOSED SCALE:3/8'=1'-0"� Ei sIr p III �1r 13'-4. it ZONING _ ? '� II I� IIIII.;./ o�a,,—°°0 RECEIVED g 1v,�, f �/, IJOU 205 E. DURANT APT. 1G ZONING tai �.I1....TLII ASPEN, CO. 81611 RECEIVED BUILIINGDEPARTMENT FLOOR PLAN PROPOSED SCALE:3/8"=1-0"O 02/06/2023 °"°"'°"� ASPEN BUILDINGDEPARTMENT