HomeMy WebLinkAboutFile Documents.1050 Matchless Dr.0113-2020-BRES (31) Colorado Regional Office Corporate Headquarters Nil C O L O R A D O CODE 4610 S Ulster,Ste.150 5776 Stoneridge Mall Rd,Ste.150 Denver,CO0 85637 Pleasant 46 C-0A 951 CONSULTING (303)400-6564 (925)463-06588 51 A shums coda Associates Company Fax:(925)463-0691 Fax:(925)463-0691 Plan Review Report Project: 1040 and 1050 Matchless Drive Project Location: Aspen, Colorado Date of Review: December 23, 2020 Based on Plans Dated: January 24, 2020 Architect: Bryan May Architecture Review Contact: Gil Rossmiller gilrossmiller@coloradocode.net Project Information Occupancy Classification: Accessory structure to Two Family Dwelling Type of Construction: N/A Total Floor Area: 1,234 s.f. and 1,141 s.f. Height (Stories/Feet): One/ -9' Automatic Fire Sprinklers: None Codes Used For Review Edition Code 2015 International Residential Code Notice This cursory plan review is based on the codes above and represents a list of corrections necessary to comply with the requirements contained within them. This review is not a building permit. The local jurisdiction is responsible for issuing the appropriate permits based on this review. The approval of plans and specifications does not permit the violation of any section of any federal, state or local regulations. All comments in this report are based on the information provided on the drawings and supporting documentation provided for review. Colorado Code Consulting, LLC does not accept any responsibility for any condition that was not known at the time of this report. We reserve the right to amend this report if additional information is received. This report does not purport to review, interpret, apply, or certify compliance with the accessibility requirements set forth within the Americans with Disabilities Act (ADA). The application, interpretation and enforcement of the ADA are vested with the Federal Department of Justice. Applicants are encouraged to seek professional review to ensure compliance with the ADA. Review Comments RECEIVED 12/24/2020 ASPEN BUILDING DEPARTMENT CCC First Review 1040 and 1050 Matchless Drive December 23, 2020 The items noted below with a comment number(B-1, B-2 etc.)are items that need to be corrected to show compliance with the applicable codes. Please provide a written response indicating where the corrections are made on the plans. This will speed up the second review process. BUILDING CODE COMMENTS B-1 This project does not specify if it was designed as an accessory structure to the duplexes per the 2015 IRC or if it was designed as a U occupancy per the 2015 IBC. This will need to be specified. We have based comments on 2015 IRC compliance. B-2 Refer to sheet A0.01; a. Listed that 0 hour fire resistance rating requirements for the building elements. However, it appears the building will be located a foot away from the property line. This will require for the wall to have a 1 hour fire rating with no openings. 2015 IRC Table R302.1(1). b. Indicates will be an unconditioned building. The assemblies on sheet A7.01 contain insulation. The code would allow an insulated unconditioned building. Please verify these buildings will not be conditioned. B-3 Refer to the ES evaluation report for the Versashield Fire-Resistant Roof Deck Protection and Underlayment; section 1.0 does not demonstrate it is in compliance with the 2015 edition of the IRC. Please provide an updated evaluation B-4 Refer to sheets A2.01 and A7.01; the following wall types do not match what is listed: a. Sheet A2.01 it lists the separation wall from units 1 from 2 and 3 from 4 as wall type W2 but on sheet A7.01 wall type W2 is listed as the trash enclosure wall (Exterior) b. Sheet A2.01 lists the trach enclosure walls as wall type W3, but on sheet A7.01 lists wall type W3 as the foundation wall. B-5 Please verify with the jurisdiction if this project will qualify for the exception to section of R309.6 as amended by Aspen. STRUCTURAL COMMENTS S-1 Refer to sheet S0.001: a. The Design Loads list the Site Elevations, K, and Ground Snow Load as ???. The established ground snow load for Aspen is 100 psf. Please clarify. b. Please verify that a portal frame design will not be required at the overhead garage door openings. S-2 Refer to sheet S6.001: a. Detail 10 Please indicate the required hanger MECHANICAL CODE COMMENTS RECEIVED M-1 No mechanical shown on the submitted plans �`// �J 12/24/2020 ASPEN BUILDING DEPARTMENT 2IPage Colorado Code Consulting, a Shums Coda Associates Company CCC First Review 1040 and 1050 Matchless Drive December 23, 2020 PLUMBING CODE COMMENTS P-1 No plumbing shown on the submitted plans ENERGY CODE COMMENTS EN-1 Un-conditioned building. Also see comment B2b ELECTRICAL CODE COMMENTS E-1 Reviewed for energy requirements only RECEIVED 12/24/2020 ASPEN BUILDING DEPARTMENT 3I ' acre Colorado Code Consulting, a Shums Coda Associates Company