Loading...
HomeMy WebLinkAboutFile Documents.1050 Matchless Dr.0113-2020-BRES (34) ESICC EVALUATION SERVICE ICC-ES Evaluation Report ESR-1463 Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE 2.0 USES PROTECTION Carlisle ethylene propylene diene monomer (EPDM), Section: 07 53 23—Ethylene-Propylene-Diene-Monomer polyvinyl chloride(PVC)and thermoplastic polyolefin(TPO) Roofing single-ply roofing membranes are used as roof coverings in Section: 07 54 19—Polyvinyl-Chloride Roofing adhered and mechanically fastened membrane roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing systems. REPORT HOLDER: 3.0 DESCRIPTION 3.1 General: CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single-ply roofing EVALUATION SUBJECT: membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and CARLISLE EPDM, PVC AND TPO SINGLE-PLY adhesives that are installed on a combustible or ROOFING MEMBRANES noncombustible deck.See Table 1 for Carlisle product trade names and corresponding product names for Mule-Hide ADDITIONAL LISTEES: Products Company, Inc., WeatherBond, Versico, Kelly Company/2001 Inc., and Roofing Products International, KELLY COMPANY/2001 INC. Inc.,the additional listees. MULE-HIDE PRODUCTS COMPANY, INC. 3.2 EPDM Membranes: VERSICO 3.2.1 Sure-Seal: Sure-Seal is a black, nonreinforced EPDM membrane,45 mils thick[0.045 inch (1.14 mm)]. WEATHERBOND 3.2.2 Sure-Seal FR: Sure-Seal FR is a black, nonreinforced EPDM membrane with fire retardants. ROOFING PRODUCTS INTERNATIONAL, INC. Available thicknesses range from 45 mils (0.045 inch 1.0 EVALUATION SCOPE [1.14 mm])to 90 mils(0.090 inch [2.29 mm]). 3.2.3 Sure-White: Sure-White is a white, nonreinforced Compliance with the following codes: EPDM membrane. It is available in thicknesses of 60 mils • 2018, 2015, 2012 and 2009 International Building Code® [0.060 inch (1.52 mm)]and 90 mils [0.090 inch (2.29 mm)]. (IBC) 3.2.4 Sure-Tough: Sure-Tough is a black, reinforced • 2018, 2015, 2012 and 2009 International Residential membrane consisting of a polyester reinforcement Code®(IRC) encapsulated between two EPDM membrane plies. It is available in thicknesses ranging from 45 mils [0.045 inch • 2013 Abu Dhabi International Building Code(ADIBC)t (1.14 mm)]to 75 mils[0.075 inch (1.90 mm)]. tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced 3.2.5 Sure-Tough FR: Sure-Tough FR is a black, in this report are the same sections in the ADIBC. reinforced membrane consisting of a polyester For evaluation for compliance with codes adopted by the reinforcement encapsulated between two EPDM membrane Los Angeles Department of Building and Safety (LADBS), plies with fire retardants. Available thicknesses are 45 mils see ESR-1463 LABC and LARC Supplement. [0.045 inch (1.14 mm)]and 60 mils [0.060 inch (1.52 mm)]. Properties evaluated: 3.2.6 Sure-Seal FleeceBACK: Sure-Seal FleeceBACK is a 45-mil to 90-mil [0.045 inch to 0.090 inch (1.14 mm to • Weather resistance 2.29 mm)] non-reinforced EPDM bonded to a polyester • Roof covering fire classification fleece. Available product thicknesses range from 100 mils [0.100 inch (2.55 mm)]to 145 mils[0.145 inch (3.68 mm)]. • Wind uplift resistance 3.2.7 Sure-White FleeceBACK: Sure-White FleeceBACK • Impact resistance is a 45-, 60- or 90-mil [0.045, 0.060 or 0.090 inch ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not.specifically addressed,nor are they to be construed � � as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as - to any finding or other matter in this report,or as to any product covered by the report. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 14 ESR-1463 I Most Widely Accepted and Trusted Page 2 of 14 (1.14, 1.52 or 2.29 mm)]nonreinforced white EPDM bonded (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils to a polyester fleece.Available product thicknesses are 100, [0.60 inch (2.03 mm)] thick, with a laminated polyester 115 and 145 mils[0.100, 0.115 or 0.145 inch (2.54, 2.92 or fleece backing. Available thicknesses are 100 mils 3.68 mm)]. [0.100 inch(2.54 mm)], 115 mils[0.115 inch(2.92 mm)]and 3.2.8 Sure-Seal AFX: Sure-Seal AFX is a 45-mil 135 mils [0.135 inch (3.43 mm)]. [0.045 inch(1.14 mm)or 60-mil[0.060 inch(1.52 mm)] non- 3.4.5 Sure-Weld AFX: Sure-Weld AFX is the Sure-Weld reinforced EPDM bonded to a 7 polyester fleece. Available HS membrane with a laminated polyester fleece backing. thicknesses are 90 mils[0.090 inch(2.29 mm)]and 105 mils Available thicknesses range from 120 mils [0.120 inch [0.105 inch (2.67 mm)]. (3.05 mm)]to 155 mils[0.155 inch (3.94 mm)]. 3.3 PVC Membranes: 3.4.6 Spectro-Weld: Spectro-Weld is the Sure-Weld 3.3.1 Sure-Flex PVC: Sure Flex PVC is a heat weldable membrane, described in Section 3.4.1, formulated with a PVC thermoplastic membrane consisting of a weft-inserted brighter white color. Available thicknesses are 60 mils polyester fabric that is encapsulated by PVC based top and [0.060 inch (1.52 mm)]and 80 mils [0.080 inch (2.03 mm)]. bottom plies. Available thicknesses range from 50 mils 3.4.7 Spectro-Weld FleeceBACK: Spectro-Weld [0.050 inch (1.27 mm)]to 80 mils [0.080 inch (203 mm)]. FleeceBACK is the Spectro-Weld membrane with a 3.3.2 Sure-Flex KEE HP: Sure Flex KEE HP is a heat laminated 5.5-ounce-per-square-yard (0.18 kg/m2) weldablepolyester fleece backing. It is 115 mils [0.115 inch theromoplastic membrane that consists of a polyester fabric that is encapsulated by KEE HP based top (2.92 mm)]thick. and bottom plies. Available thicknesses range from 50 mils 3.5 Insulation: [0.50 inch (1.27 mm)]to 80 mils[0.80 inch (2.03 mm)]. See Tables 2 through 5 for insulations for use with specific 3.3.3 Sure-Flex PVC FRS: Sure-Flex PVC FRS is a heat- roofing systems. Foam plastic insulation, where used, must weldable thermoplastic membrane that consists of a have a flame-spread index of not more than 75 when tested fiberglass reinforcement encapsulated with PVC based top at the maximum thickness intended for use in accordance and bottom plies. Available thicknesses range from 60 mils with ASTM E84 or UL 723. [0.60 inch (1.52 mm)]to 80 mils[0.80 inch (2.03 mm)]. 3.6 Barrier Board: 3.3.4 Sure-Flex PVC FleeceBACK: Sure-Flex PVC Barrier board, where used, must be either minimum FleeceBACK membrane consists of polyester reinforcing 1/4-inch-thick (6.4 mm) Georgia-Pacific Gypsum LLC scrim and polyester fleece backing. Available thicknesses "DensDeck®Roofboard" or"DensDeck Prime®Roofboard," range from 115 mils [0.115 inch (2.92 mm)] to 135 mils minimum 1/4-inch-thick (6.4 mm) Owens Corning [0.135 inch (3.43 mm)]. "StrataGuard," minimum 1/4-inch-thick (6.4 mm) USG 3.3.5 Sure-Flex KEE HP FleeceBACK: Sure Flex KEE Corporation "SECUROCK® Gypsum-Fiber Roof Board" HP FleeceBACK membrane consists of a polyester or `SECUROCK® Glass-Mat Roof Board," or minimum 1/2-inch-thick (12.7 mm) gypsum board. Barrier board must reinforcing scrim, polyester fleece backing, and DuPont® be UL-classified for roofing applications or UL classified Elvaloy® KEE HP copolymer. Available thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 135 mils gypsum board. [0.135 inch (3.43 mm)]. 3.7 Slip Sheet: 3.3.6 Sure-Flex PVC FRS FleeceBACK: Sure-Flex PVC The slip sheet,where used, must include Carlisle"FR Base FRS FleeceBACK membrane consists of a high-strength Sheet 1 S or 2S," GAF "VersaShield® Fire-Resistant Roof fiberglass scrim and polyester fleece backing. Available Deck Protection (ESR-2053)," Elk "VersaShield thicknesses range from 115 mils [0.115 inch (2.92 mm)] to FB-1S or FB-2S", or Atlas "FR 10 or FR 50." Slip sheets 135 mils[0.135 inch (3.43 mm)]. must be UL-classified for roofing applications. 3.3.7 Sure-Flex KEE HP FRS FleeceBACK: Sure-Flex 3.8 Flashing: KEE HP FRS FleeceBACK membrane consists of a Flashing must be provided in accordance with IBC Section fiberglass reinforcing scrim, polyester fleece backing, and 1503.2 or IRC Section R903.2, as applicable. Where DuPont® Elvaloy® KEE HP copolymer. Available flashing is of metal, the metal must be corrosion-resistant, thicknesses range from 105 mils [0.105 inch (2.67 mm)] to minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized 135 mils[0.135 inch (3.43 mm)]. steel. 3.4 TPO Membranes: 3.9 Fasteners: 3.4.1 Sure-Weld: Sure-Weld membrane consists of a Fasteners, used to mechanically attach insulation and polyester reinforcement encapsulated between two plies of membranes to the roof deck, must be corrosion-resistant, TPO. The membrane is available in white, gray, tan and and must be Carlisle fasteners, plates or fastening bars, custom colors. Available thicknesses range from 45 mils unless otherwise noted in this report. Refer to Table 4 and [0.045 inch (1.14 mm)]to 80 mils [0.080 inch (2.03 mm)]. 5 for spacing of fasteners. 3.4.2 Sure-Weld HS: Sure-Weld HS is the Sure-Weld 3.9.1 HP Fastener: This is an epoxy-coated steel screw membrane formulated with an additional flame retardant for used in combination with Carlisle's fastening plates or bars fire resistance at higher slopes.The membrane is available to mechanically attach roofing insulation and membranes to in white,gray,tan and custom colors.Available thicknesses steel or wood substrate. Fastener length must be selected are 45 mils (0.045 inch [1.14 mm])and 60 mils (0.060 inch to penetrate through the steel deck a minimum of 3/4 inch [1.52 mm]). (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.4.3 Sure-Weld SAT-TPO:Sure-Weld SAT-TPO is a self 3.9.2 InsulFast Insulation Fastener: This is an epoxy adhered version of the Sure-Weld HS membrane with adhesive. coated steel screw used in combination with Carlisle's insulation plates to mechanically attach roofing insulation to 3.4.4 Sure-Weld FleeceBACK: Sure-Weld FleeceBACK steel or wood substrates. Fastener length must be selected is the Sure-Weld HS membrane, 45 mils [0.045 inch to penetrate through the steel deck a minimum of 3/4 inch ESR-1463 I Most Widely Accepted and Trusted Page 3 of 14 (19.1 mm), or into the wood deck a minimum of 3.9.14 PVC Oval Barbed Plate: This is a 11/2-inch-by- 1 inch (25.4 mm). 23/4-inch(35 mm by 69.85 mm)Oval Barbed Plate designed 3.9.3 HP Purlin Fastener: This is an epoxy coated steel to be used with HP-X Fasteners to mechanically attach PVC screw used in combination with Carlisle's fastening plates or membranes to the roof deck. bars to mechanically attach roofing insulation and 3.9.15 OMG Roofing Products RhinoBond Plate: The membranes to structural steel members. Fastener length RhinoBond Plate is a 3-inch-diameter (76.2 mm), must be selected to penetrate through the steel member a 0.028-inch-thick (0.7 mm) galvalume-coated steel plate, minimum of 3/4 inch (19.1 mm.) coated with a proprietary adhesive and used with the HP-X fastener to mechanically attach PVC and TPO membranes 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy- to the roof deck. The adhesive bonds the plate to the coated steel screw used in combination with Carlisle's underside of the membrane. fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener 3.10 Carlisle Syntec Adhesives: See Tables 2 and 5 for length must be selected to penetrate into the concrete deck adhered roofing systems. a minimum of 1 inch (25.4 mm). 3.10.1 90-8-30A Bonding Adhesive: 90-8-30A Bonding 3.9.5 CD-10 Fastener: The CD-10 is an epoxy-coated, Adhesive is a high-strength, solvent-based contact hammer-driven, nonthreaded fastener specifically designed adhesive used to adhere EPDM membranes to the to be used with insulation and seam fastening plates to insulation or substrate. It has a coverage rate of secure membrane and insulation to structural concrete. approximately 60 square feet per gallon (1.5 m2/L) when Fastener length must be selected to penetrate into the applied to the finished surface area. The adhesive is concrete deck a minimum of 1 inch (25.4 mm). supplied in 5-gallon (18.9 L) containers and has a shelf life of one year. 3.9.6 Lite-Deck Fastener:The Lite-Deck Fastener is used in conjunction with a specially designed 3-inch 3.10.2 Aqua Base 120 Bonding Adhesive:Aqua Base 120 (76.2 mm) Lite-Deck Metal Plate for insulation attachment Bonding Adhesive is a high strength, water based contact to gypsum, cementitious wood fiber (Tectum [ESR-1112]), adhesive used to adhere EPDM and TPO membranes to the and lightweight concrete decks. Fastener length must be insulation or substrate. It has a coverage rate of selected to penetrate into the deck a minimum of 2 inches approximately 120 square feet per gallon (3 m2/L) when (50.8 mm). applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life 3.9.7 GypTec Fastener:The GypTec Fastener is a glass- of one year. filled nylon auger fastener designed for securing 3.10.3 Low-VOC PVC Bonding Adhesives: Low VOC mechanically attached membranes and insulation to PVC Bonding Adhesives is high-strength, solvent-based gypsum and cementitious wood fiber(Tectum [ESR-1112]) contact adhesives used to adhere PVC membranes to an decks. Fastener length must be selected to penetrate into insulation or substrate. They have a coverage rate of the deck a minimum of 1.5 inches(38.1 mm). approximately 60 square feet per gallon (1.5 m2/L) when 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter applied to the finished surface area. The adhesive is (50 mm)polymer plate designed to be used with HP and HD supplied in 5-gallon (18.9 L) containers with a shelf life of 14-10 fasteners to mechanically attach roofing membranes one year. to the roof deck. 3.10.4 Sure-Weld TPO Bonding Adhesive: Sure-Weld 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is TPO Bonding Adhesive is a high-strength, solvent-based a heavy-duty, epoxy-coated steel screw and bar used to contact adhesive used to adhere TPO membranes to an secure reinforced EPDM membranes to steel or wood deck. insulation or substrate. It has a coverage rate of The bar is 1-inch-wide-by-0.040-inch-thick-by-10-foot-long approximately 60 square feet per gallon (1.5 m2/L) when (25.4 mm by 1.1 mm by 3.1 m)galvalume-coated steel with applied to the finished surface area. The adhesive is pre-punched holes 6 inches(150 mm)on center. supplied in 5-gallon (18.9 L) containers with a shelf life of 3.9.10 HP-X Fastener: This is an epoxy-coated carbon one year. steel screw used in combination with the Piranha Fastening 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Plate to mechanically attach TPO membranes to steel or Adhesive is a high-strength, solvent-based contact wood substrate. Fastener length must be selected to adhesive used to adhere EPDM and TPO membranes to an penetrate through the steel deck a minimum of 3/4 inch insulation or substrate. It has a coverage rate of (19.1 mm), and into the wood deck a minimum of 1 inch approximately 60 square feet per gallon (1.5 m2/ L) when (25.4 mm). applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- one year. diameter galvalume-coated steel plate designed to be used with HP-X fasteners to mechanically attach PVC and TPO 3.10.6 HydroBond Water-Based Bonding Adhesive: membranes to the roof deck. HydroBond Water-Based Bonding Adhesive is a water- based,wet lay-in, one-sided adhesive to be used to adhere 3.9.12 HP-XTRA Fastener:This is an epoxy-coated carbon Sure-Flex PVC, Sure-Flex PVC FRS and FleeceBACK steel screw used in combination with the Piranha XTRA membranes to an insulation or substrate. It has a coverage Fastening Plate to mechanically attach PVC and TPO rate of 100 square feet per gallon (2.5 m2/L). The adhesive membranes to steel or wood substrate. Fastener length is supplied in 5-gallon (918.9 L) containers with a shelf life must be selected to penetrate through the steel deck a of one year. minimum of 3/4 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC Bonding Adhesive 1168 is high-strength, solvent-based 3.9.13 Piranha XTRA Fastening Plate: This is a 23/8-inch- contact adhesive used to adhere EPDM and TPO diameter galvalume-coated steel plate designed to be used membranes to an insulation or substrate. It has a coverage with HP-XTRA fasteners to mechanically attach PVC and rate of approximately 60 square feet per gallon (1.58 m2/L) TPO membranes to the roof deck. when applied to the finished surface area. The adhesive is ESR-1463 I Most Widely Accepted and Trusted Page 4 of 14 supplied in 5-gallon (18.9 L) containers with a shelf life of against contact with incompatible materials.Where gypsum one year. board is used as barrier board in the roofing assembly, 3.10.8 Solvent-Free EPDM Bonding Adhesive: Solvent- weather protection must be provided to prevent damage to Free EPDM Bonding Adhesive is a high-strength, polymer the gypsum board prior to application of the roofing based adhesive. This adhesive can be used to adhere all membrane. Sure-Seal or Sure-White EPDM membranes as a The slope of the roof on which the single-ply membranes one-sided, wet lay-in adhesive. It has a coverage rate of are installed must not be more than the maximum slope 100 square feet per gallon (2.5 m2/L). The adhesive is indicated for the particular assembly as listed in Tables 2 supplied in 5-gallon(18.9 L)containers with a shelf life of six and 3. months. Penetrations and terminations of the roof covering must 3.10.9 Cold Applied Adhesive: Cold Applied Adhesive is a be flashed and made weather tight in accordance with the solvent-free, asphalt-modified polyether adhesive. This requirements of the membrane manufacturer and the adhesive can be used with all Sure-Seal or Sure-Weld AFX applicable code. membranes as a one-sided, wet lay-in adhesive. It has a coverage rate of 67 square feet per gallon (1.6 m2/L). The 4.2 Fire Classification: adhesive is supplied in 5-gallon (18.9 L) containers with a 4.2.1 New Construction: The adhered and mechanically shelf life of one year. fastened EPDM, PVC, and TPO single-ply membrane 3.10.10 FAST Adhesives: FAST 100, FAST 100LV, and roofing systems, when installed in accordance with this Flexible FAST Adhesives are two-component polyurethane report, are Class A, B or C roof covering systems in adhesives used to adhere FleeceBACK membranes and accordance with ASTM E108 or UL 790, as noted in Tables insulations to various substrates. The adhesives have a 2 and 3. coverage rate of approximately 100 square feet per gallon 4.2.2 Reroofing: The existing deck must be inspected to (2.5 m2/L). The adhesives are supplied in 5-gallon (18.9 L) verify that the structure to be reroofed is structurally sound jugs, 15-gallon (56.7 L) and 50-gallon (189 L) drums, box and adequate to support and secure the roofing membrane. sets, cartridge tubes,dual tanks, and/or cylinders,and have Prior to installation of new roof coverings, inspection by and a shelf life of one year. written approval from the code official having jurisdiction 3.10.11 OlyBond 500 Adhesive: OMG Roofing Products must be required. OlyBond 500 Spot Shot and OlyBond 500 BA are Class A, B or C roof covering systems may be installed two-component polyurethane adhesives used to adhere over existing classified roof covering systems under the insulations to various substrates. The adhesives have a following conditions without additional roof classification coverage rate of approximately 100 square feet per gallon tests, provided the resulting classification is the lower of the (2.5 m2/L). The adhesives are supplied in cartridge tubes new or existing roofing classification: and box sets, and have a shelf life of one year. • New uninsulated systems installed only over existing 3.10.12 EPDM X-23 Low-VOC Bonding Adhesive: uninsulated assemblies. EPDM X-23 Low-VOC Bonding Adhesive is a high strength, solvent-based contact adhesive used to adhere EPDM • New insulated systems installed over existing membranes to an insulation or substrate. It has a coverage uninsulated systems only. rate of approximately 60 square feet per gallon (1.5 m2/L) 4.3 Wind Resistance: when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of 4.3.1 New Construction: The allowable wind uplift one year. pressures for the EPDM,PVC,and TPO roofing membranes 3.10.13 CAV-GRIP III Low-VOC Adhesive/Primer: CAV as parts of roof assemblies are noted in Tables 4 and 5. GRIP III Low-VOC Adhesive/Primer is a contact adhesive Metal edge securement systems must be listed in used to adhere EPDM and TPO membranes to various accordance with the 2011 edition of ANSI/SPRI/FM4435 substrates. It has a coverage rate of 1000 ft2 per cylinder ES-1 and designed and installed for wind loads in when applied to the finished surface area. The adhesive is accordance with IBC Section 1504.5 and IBC Chapter 16. supplied in No. 40 cylinders with a shelf life of one year 4.3.2 Reroofing: Mechanically anchored systems may be (unopened). accepted based on the adequacy of anchors penetrating 3.11 Impact Resistance: through existing roof coverings into structural substrates. The EPDM, PVC, and TPO roofing membranes described Since the composition and/or condition of any particular in this report meet requirements for impact resistance in IBC existing underlying material may vary widely, reroofing with Section 1504.7,based on testing in accordance with Section adhered systems is outside the scope of this report. 4.6 of FM 4470. 5.0 CONDITIONS OF USE 4.0 INSTALLATION The single-ply EPDM, PVC, and TPO roofing membranes 4.1 General: described in this report comply with, or are suitable Installation of the EPDM, PVC, and TPO roofing alternatives to what is specified in, those codes listed in membranes described in this report must comply with the Section 1.0 of this report,subject to the following conditions: applicable code, the manufacturer's published installation 5.1 Installation must comply with the applicable code, the instructions and this report. The manufacturer's published manufacturer's published installation instructions and installation instructions must be available at all times on the this report. The instructions within this report must jobsite during installation. govern if there are any conflicts between the The substrate to which the membrane is to be applied manufacturer's installation instructions and this report. must be clean, dry, and free of frost, loose fasteners, and 5.2 The adhered and mechanically fastened single-ply other protrusions or contaminates that will interfere with the membrane roofing systems must be installed by adhesion or attachment of the membrane or that will professional roofing contractors who are trained and puncture the membrane. All materials must be protected approved by the manufacturer. ESR-1463 I Most Widely Accepted and Trusted Page 5 of 14 5.3 Foam plastic insulation must be separated from the additional listee, the manufacturer's address or plant interior of the building by an approved thermal barrier code and the ICC-ES evaluation report number in accordance with IBC Section 2603.4.1.5 or IRC (ESR-1463). Section R316.4, as applicable. 7.2 The report holder's contact information is the following: 5.4 Foam plastic insulation, where used, must bear the CARLISLE SYNTEC SYSTEMS, A DIVISION OF label of an approved agency indicating that the foam CARLISLE CONSTRUCTION MATERIALS plastic has a flame-spread index of not more than 75 POST OFFICE BOX 7000 when tested at the maximum thickness intended for CARLISLE, PENNSYLVANIA 17013 use in accordance with ASTM E84 or UL 723, subject (717)245-7000 to the approval of the code official. www.carlislesyntec.com 5.5 Design wind uplift pressure on any roof area, including 7.3 The Additional Listees' contact information is the edge and corner zones, must not exceed the allowable following: wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures KELLY COMPANY/2001 INC. for systems as listed in Tables 4 and 5. 325 THOMASTON AVENUE 5.6 The allowable wind uplift pressures listed in Tables 4 WATERBURY, CONNECTICUT 06702 and 5 are for the roof covering system only. The deck (203) 575-9220 and framing to which the system is attached must be MULE-HIDE PRODUCTS COMPANY, INC. designed for the applicable components and cladding 1195 PRINCE HALL DRIVE wind loads in accordance with the applicable code. BELOIT,WISCONSIN 53511 5.7 When application is over existing roofs,documentation (800) 786-1492 of the wind-uplift resistance of the composite roof construction must be submitted to the code official for VERSICO approval at the time of permit application. POST OFFICE BOX 1289 5.8 For buildings under the IBC, above deck thermal CARLISLE, PA 17013 insulation board must comply with the applicable (800)992-7663 standards listed in IBC Table 1508.2 or IRC Table WEATHERBOND R906.2, as applicable. POST OFFICE BOX 251 5.9 The roofing membranes are manufactured at Carlisle, PLAINFIELD, PENNSYLVANIA 17081 Pennsylvania; Greenville, Illinois; Tooele, Utah; and (866)471-5125 Senatobia, Mississippi,under a quality control program with inspections by ICC-ES. ROOFING PRODUCTS INTERNATIONAL, INC. 6.0 EVIDENCE SUBMITTED 57460 DEWITT STREET ELKHART, INDIANA 46517 Data in accordance with ICC-ES Acceptance Criteria for (800)628-2957 Membrane Roof-covering Systems (AC75), dated July 2010 (editorially revised March 2018). 7.0 IDENTIFICATION 7.1 Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec Systems) or the name of the ESR-1463 I Most Widely Accepted and Trusted Page 6 of 14 TABLE 1—PRODUCT NAMES CARLISLE KELLY CO./ MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND PRODUCT ROOFING PRODUCTS PRODUCT NAME 2001 INC. NAME NAME NAME INTERNATIONAL PRODUCT NAME PRODUCT NAME Sure-Seal C-EPDM Mule-Hide Standard VersiGard Non-reinforced WeatherBond EPDM Non- Royal Edge Non- Black EPDM EPDM Reinforced Membrane Reinforced EPDM Sure-Seal FR C-EPDM-C Mule-Hide FR EPDM VersiGard FR Non- WeatherBond EPDM FR Royal Edge Non- Reinforced EPDM Non-Reinforced Membrane Reinforced FR EPDM Sure-Seal FleeceBACK C-EPDM-FB - VersiFleece EPDM WeatherBond Fleece EPDM Royal Edge EPDM Membrane FleeceBACK - Sure-Seal AFX C-EPDM-AFX - VersiFleece AC EPDM WeatherBond EPDM AC Fleece Membrane Sure-Tough C-EPDM-C,Type 2 Mule-Hide Standard VersiGard Reinforced WeatherBond EPDM Royal Edge Reinforced Reinforced EPDM EPDM Reinforced Membrane EPDM Sure-Tough FR C-EPDM-CR Reinforced Mule-Hide FR VersiGardFR Reinforced WeatherBond EPDM FR Royal Edge Reinforced Reinforced EPDM EPDM Reinforced Membrane Fire Rated EPDM Sure-White C-EPDM-White Mule-Hide White-on- VersiGard—White WeatherBond EPDM White Re-Flex White EPDM Black EPDM Standard Membrane Sure-White FleeceBACK C-EPDM-FB-White - - Re-Flex White EPDM FleeceBACK Sure-Weld TPO-K Mule-Hide TPO-c VersiWeld Reinforced WeatherBond TPO Re-Flex TPO TPO Membrane Membrane Sure-Weld HS TPO-K-FR Mule-Hide TPO-c(FR) VersiWeld HS WeatherBond TPO High Re-Flex TPO HS Slope Membrane Sure-Weld SAT-TPO TPO-K_SAT Mule-Hide SA-TPO VersiWeld QA TPO WeatherBond TPO PAS Re-Flex TPO SAT Membrane Membrane Sure-Weld FleeceBACK TPO-K-FB Mule-Hide TPO-c VersiFleece TPO WeatherBond FleeceTPO Re-Flex TPO Fleece Back Membrane FleeceBACK Sure-Weld AFX TPO-K-AFX Mule-Hide TPO-c VersiFleece AC TPO WeatherBond TPO AC Fleece Back Plus Fleece Membrane Spectro-Weld - - - - - Spectro-Weld - FleeceBACK Mule-Hide PVC WeatherBond PVC Re-Flex PVC Sure-Flex PVC - Membrane VersiFlex PVC Membrane Mule-Hide PVC KEE HP WeatherBond KEE HP Re-Flex KEE HP Sure-Flex KEE HP - Membrane VersiFlex KEE HP Membrane Sure-Flex PVC FRS Mule-Hide PVC FRS VersiFlex FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC Membrane Membrane Sure-Flex PVC Mule-Hide PVC VersiFleece PVC WeatherBond PVC Fleece - - FleeceBACK FleeceBack Membrane Membrane Sure-Flex KEE HP Mule-Hide PVC KEE HP WeatherBond KEE HP - - FleeceBACK Fleece Back Membrane VersiFleece KEE HP Fleece Membrane Sure-Flex PVC FRS VersiFleece FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC - -FleeceBACK Fleece Membrane FleeceBACK Sure-Flex KEE HP FRS WeatherBond KEE HP FRS - FleeceBACK - - VersiFleece FRS KEE HP Fleece Membrane 90-8-30A Bonding 2001 Inc.Bonding Mule-Hide Bonding G200SA Yellow LC-60 Bonding Adhesive Royal Edge Bonding Adhesive Adhesive Adhesive Substrate Adhesive Adhesive EPDM X-23 Low-VOC EPDM X-23 Low VOC EPDM X-23 Low VOC EPDM X-23 Low VOC - Bonding Adhesive Bonding Adhesive Bonding Adhesive Bonding Adhesive Solvent-Free EPDM Solvent-Free EPDM Solvent-Free EPDM Bonding Royal Edge Solvent-Free Bonding Adhesive Bonding Adhesive Adhesive EPDM Bonding Adhesive Aqua Base 120 Bonding _ Aqua Base 120 Bonding Aqua Base 120 Bonding Aqua Base 120 Bonding Royal Edge Water Based Adhesive Adhesive Adhesive Adhesive Bonding Adhesive Sure-Weld TPO Bonding - Mule-Hide TPO-c VersiWeld TPO Bonding TPO Bonding Adhesive Royal Edge EPDM/TPO Adhesive Bonding Adhesive Adhesive Bonding Adhesive Low VOC Bonding - Low VOC Bonding LOW VOC Bonding Low VOC Bonding Adhesive Royal Edge Low VOC Adhesive Adhesive Adhesive Bonding Adhesive Low VOC Bonding - Low VOC Bonding Low VOC Bonding Low VOC Bonding Adhesive -- Adhesive 1168 Adhesive 1168 Adhesive 1168 1168 Low VOC PVC Bonding _ Low-VOC PVC Bonding Low-VOC PVC Bonding Low-VOC PVC Bonding Re-Flex PVC Low VOC Adhesive Adhesive Adhesive Adhesive Bonding Adhesive HydroBond Water- HydroBond Water- HydroBond Water-Based HydroBond Water-Based Based Bonding Based Bonding Bonding Adhesive Bonding Adhesive Adhesive Adhesive- CAV-GRIP III Low VOC Cav-Grip 3V Low VOC Cav-Grip III Low VOC - Adhesive/Primer AeroWeb Adhesive Adhesive/Primer Adhesive/Primer ESR-1463 I Most Widely Accepted and Trusted Page 7 of 14 TABLE 1—PRODUCT NAMES(continued) CARLISLE KELLY CO./ MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND ROOFING PRODUCTS PRODUCT NAME 2001 INC. NAME NAME PRODUCT NAME INTERNATIONAL PRODUCT NAME PRODUCT NAME Cold Applied Adhesive - Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive RPI Cold Applied Adhesive FAST 100 Adhesive - DASH 100 Adhesive - - FAST 100-LV Adhesive Helix®2 Low-Rise DAST Adhesive DASHAdhesive FastBond 100 LV Adhesive Adhesive Flexible FAST Adhesive Helix®Max Low-Rise Flexible DAST Adhesive Flexible DASH Adhesive FastBond Flex Adhesive Adhesive OlyBond 500 Adhesive - - OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2,5 SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 1 1/4:12 Sure-Weld,Spectro-Weld — Sure-Seal FR,Sure-Tough, Sure-White,Sure-Seal FleeceBACK, 2 1/2:12 Any of the following Sure-Weld HS,Sure-Weld SAT-TPO, insulations, 1-inch min.to Sure-Weld FleeceBACK, 6-inch max.thickness: Spectro-Weld FleeceBACK, A Noncombustible — Carlisle"SecurShield Sure-White FleeceBACK Polyiso","InsulBase", Sure-Flex PVC FleeceBACK, Hunter Panels"H-Shield" Sure-Flex KEE HP FleeceBACK, 3 3/4:12 or"H-Shield-CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 4 2:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP 5 3/4:12 Sure-White FleeceBACK 6 1:12 Sure-Seal FR,Sure-Tough 1/2-inch-thick fiberboard4, Sure White,Sure Seal FleeceBACK, 1/2-inch-thick fiberboard4 Sure-Weld,Spectro-Weld,Sure-Weld or barrier board HS,Sure-Weld SAT-TPO, (see Section 3.6)over Sure-Weld FleeceBACK, A Noncombustible — 5-inch max Insulfoam EPS3, 1/2-inch-thick Spectro-Weld FleeceBACK, 7 11/2:12Sure-Flex PVC,Sure-Flex PVC FRS, fiberboard or barrier board Sure Flex KEE HP, (see Section 3.6)over Sure-Flex PVC FleeceBACK, System No. 1 insulations Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 8 3/4:12 Sure-White FleeceBACK 9 11/2:12 Sure-White,Sure-Seal FleeceBACK Sure-Tough,Sure-Weld,Spectro-Weld, 10 Noncombustible 3:12 1/4-inch thick Sure-Weld FleeceBACK, or Combustible _ "DensDeck Prime" Spectro-Weld FleeceBACK 11 A -min.15/32-inch- 4:12 or 1/4-inch thick — Sure-Weld HS,Sure-Weld SAT-TPO thick plywood or "SECUROCK 12 min.7/16-inch- Unlimited Gypsum Fiber Roof Sure-Seal FR,Sure-Flex PVC, thick OSB. Board" Sure-Flex PVC FRS,Sure-Flex KEE HP Sure-Flex PVC FleeceBACK, 13 3:12 Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBack ESR-1463 I Most Widely Accepted and Trusted Page 8 of 14 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2'5(continued) SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 14 1/4:12 Sure-Weld,Spectro-Weld Sure-Seal FR,Sure-Tough,Sure-White, Sure-Seal FleeceBACK,Sure-Weld HS, 15 1/2:12 Any of the following Sure-Weld SAT-TPO,Sure-Weld Combustible Barrier board insulations, 1-inch min.to FleeceBACK,Spectro-Weld min.15/32-inch- (see Section 3.6)or 6-inch max.thickness: FleeceBACK,Sure-White FleeceBACK A thick plywood or Carlisle"SecurShield Slip sheet:2 layers Sure-Flex PVC FleeceBACK, min.7/16-inch- Polyiso","InsulBase", 16 thick OSB. 3/4:12 (see Section 3.7) Hunter Panels"H-Shield" Sure Flex KEE HP FleeceBACK, or"H-Shield-CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE FRS FleeceBACK 17 2:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP Noncombustible or Any of the following Combustible insulations, min. 1-inch. 18 C min.15/32-inch- Unlimited — thickness:Carlisle EPDM, PVC and TPO Membranes thick plywood or "InsulBase"or Hunter min.7/16-inch- Panels"H-Shield" thick OSB. Single layer of minimum 3.0"or double layer of 19 A Combustible 1/2:12 — minimum 1.5"Carlisle EPDM, PVC,and TPO Membranes "SecurShield Polyiso"or Hunter Panels "H-Shield-CG" Single layer of minimum 20 B Combustible I 1/2;12 — 1.9"Carlisle"SecurShield EPDM, PVC,and TPO Membranes Polyiso"or Hunter Panels "H-Shield-CG" I For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2See Section 3.10 for adhesive application rate. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to max.1/2:12. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 9 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS" SYSTEM ROOF DECK MAX. BARRIER BOARD INSULATION' MEMBRANE/MAX.ROOF SLOPE NO. CLASS SLOPE OR SLIP SHEET 1 /z:12 Any of the following Sure-Tough,Sure-Weld, insulations, 1-inch min.to Spectro-Weld 2 11/2:12 6-inch max.thickness: Sure-Weld HS A Noncombustible — Carlisle"SecurShield 3 3/4:12 Polyiso"or"InsulBase", Sure-Tough FR 4 21/2:12 Hunter Panels"H-Shield"or Sure-Flex PVC,Sure-Flex KEE HP "H-Shield-CG" 5 1:12 1/2-inch-thick fiberboard3, Sure-Tough,Sure-Flex /2-inch-thick fiberboard4 or barrier board Sure-Weld,Spectro-Weld, 6 1 /2:12 (see Section 3.6)over 5-inch _ A Noncombustible — max Insulfoam EPS2, Sure-Weld HS 1/2-inch-thick fiberboard or 7 21/2:12 barrier board Sure-Tough FR (see Section 3.6)over System No. 1 insulations Sure-Weld,Spectro-Weld, 8 A Noncombustible 1/2:12 — To 5-inch max: Insulfoam SP Sure-Weld HS,Sure-Flex, Sure-Flex KEE HP 9 Noncombustible 3:12 Sure-Tough,Sure-Weld,Spectro-Weld or Combustible 10 A min.13/32-inch- 31/2:12 Barrier board — Sure-Tough FR thick plywood or (see Section 3.6) min.7/16-inch- Sure-Weld HS,Sure-Flex, 11 thick OSB. Unlimited Sure-Flex KEE HP 12 1/2:12 Any of the following Sure-Tough,Sure-Weld,Spectro-Weld Combustible insulations, 1-inch min.to 13 min. 15/32-inch- 11/2:12 Barrier board(see Section 3.6) 6-inch max.thickness: Sure-Weld HS A thick plywood or or Carlisle"SecurShield 14 min.'/,6 inch- 3/4:12 Slip sheet:2 layers, Polyiso"or"InsulBase", Sure-Tough FR thick OSB. (see Section 3.7) Hunter Panels"H-Shield"or 15 21/2:12 "H-Shield-CG" Sure-Flex PVC,Sure-Flex KEE HP 16 Combustible 1:12 Sure-Tough min.15/32 inch- Slip sheet,2 layers A thick plywood or — Sure-Tough FR,Sure Weld, (see Section 3.7) 17 min.7/16-inch- 11/2:12 Spectro-Weld,Sure-Weld HS, thick OSB Sure-Flex,Sure-Flex KEE HP Combustible min.15/32-inch- Slip sheet, Sure-Tough,Sure-Tough FR, 18 B thick plywood or 11/2:12 1 layer — Sure-Weld,Spectro-Weld,Sure-Weld min.7/16-inch- (see Section 3.7) HS,Sure-Flex,Sure-Flex KEE HP thick OSB. Combustible Any of the following min 15/32 inch- insulations, 1-inch min. 19 C thick plywood or Unlimited — thickness:Carlisle EPDM, PVC and TPO Membranes min.'/1s inch- "SecurShield Polyiso"or thick OSB. "InsulBase",Hunter Panels "H-Shield"or H-Shield CG" Single layer of minimum 3-inch or double layer of 20 A Combustible 1/2:12 — minimum 1.5-inch Carlisle EPDM,PVC,and TPO Membranes "SecurShield Polyiso"or Hunter Panels"H-Shield-CG" Single layer of minimum 1.9-inch Carlisle"SecurShield 21 B Combustible 1/2:12 — Polyiso"or Hunter Panels EPDM,PVC,and TPO Membranes "H-Shield-CG"or single layer of an inverted G3 cap sheet. For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 4When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 10 of 14 TABLE 4—WIND RESISTANCE—MECHANICALLY FASTENED ASSEMBLIES4'7 MAXIMUM MAXIMUM MAXIMUM SYSTEM ALLOWABLE DECKS INSULATIONS MEMBRANE MEMBRANE FASTENER FASTENER NO. WIND UPLIFT FASTENING SPACING ROW (psf) (inches) SPACINGS Foam plastic insulation'2' 1 45 Noncombustible 1/2-inch-thick fiberboards or Sure-Tough HP-X Fastener& 12 6 ft 6 inches barrier board Metal Fastening Bar (See Sect.3.6) — 2 75 Noncombustible Same as System No.1 Sure-Tough HP-X Fastener& 6 6 ft 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches Polymer Seam Plate 4 45 Noncombustible Same as System No.1 Sure-Tough Sure-Tite Fastener& 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 12 9 ft 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure-Weld or HP-X or HP-Xtra 7 45 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 7 ft 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure-Weld or HP-Xtra Fasteners with 12 9 ft 6 inches Spectro-Weld Piranha Xtra Plates HP-X or HP-Xtra 9 60 Noncombustible Same as System No. 1 Sure-Weld or Fasteners with 6 9 ft 6 inches Spectro-Weld Piranha or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 10 67 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 7 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 11 30 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 12 60 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure-Flex PVC or HP-X Fasteners with 6 6 ft 4 inches Sure-Flex KEE HP Piranha Plates 14 83 Noncombustible Same as System No.1 Sure-Flex PVC or HP-X Fasteners with 6 2 ft 11 inches Sure-Flex KEE HP Piranha Plates Sure-Flex PVC or HP-X or HP-Xtra 15 30 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates Sure-Flex PVC or HP-X or HP-Xtra 16 45 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure-Flex KEE HP Sure-Flex PVC or HP-X Fasteners Plateswith 12 2 ft 11 inches Piranha Sure-Flex PVC or HP-X or HP-Xtra 18 60 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 6 9 ft 7 inches Plates 19 45 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 5.3 ft2 N/A OMG RhinoBond Plates 20 60 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa. 'Foam plastic insulation must be any of the following(1-inch min.to 6-inch max.thickness):Carlisle"SecurShield Polyiso","InsulBase"Hunter Panels"H-Shield"or Hunter Panels"H-Shield-CG". 2All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 'Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength(VO of 2500 psi.See Section 5.6 of this report. °For existing metal roofing,the assemblies listed must be installed by fastening through the roofing and into structural members(purlins,angle iron,beams,etc.) capable of resisting all expected loads.The maximum allowable wind uplift(field)pressures are shown in Column 2. 'UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. 'Fastener row spaces shown are for field of roof only.See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies.Distance between the edge of the roof and the first row of fasteners must be determined accordingly. ESR-1463 I Most Widely Accepted and Trusted Page 11 of 14 TABLE 5—WIND RESISTANCE—ADHERED ASSEMBLIES5,6 ALLOWABLE INSULATION SYSTEM WIND UPLIFT DECK2 INSULATION/MIN.THICKNESS''' FASTENING MEMBRANE NO. (FIELD) RATE TYPE (psf) 1/2 inch fiberboard4,15/32 inch OSB,or'/4-inch thick 1 45 Combustible or "DensDeck Prime"or 1/4-inch thick"SECUROCK 1 er 2 ft2 EPDM, PVC and TPO Noncombustible Gypsum Fiber Roof Board" p Membranes Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 2 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/1.4 inch 1 per 3.2 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 3 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 4 ft2 EPDM, PVC and TPO Noncombustible with 5/8-inch SECUROCK coverboard(optional) Membranes 4 68 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/1.0 inch Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 5 75 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1.6 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes 6 113 Combustible or Carlisle"SecurShield"or"H-Shield CG"/2.0 inch 1 per 1ft2 PVC Membranes Noncombustible TPO Membranes; 7 120 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 1per 1 ft2 EPDM membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch p (with noncombustible deck only) Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 8 128 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 EPDM and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 9 135 Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 FleeceBACK Membranes with 1/2-inch SECUROCK coverboard(optional) 10 143 Combustible or 1/2 inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes Noncombustible For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa 1AII foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength (f"c)of 2500 psi.See Section 5.6 of this report. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When application is over existing roofs,documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application.For reroofing or recovering,installation must be in accordance with 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. 'See Section 3.10 for adhesive application rate. ESlcc EVALUATION SERVICE ICC-ES Evaluation Report ESR-1463 LABC and LARC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety(LADBS). Applicable code editions: • 2017 City of Los Angeles Building Code(LABC) • 2017 City of Los Angeles Residential Code(LARC) 2.0 CONCLUSIONS The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463,comply with the LABC Chapters 7A and 15,the LARC Section R337 and LARC Chapter 9,and are subjected to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in this evaluation report must comply with all of the following conditions: • All applicable sections in the evaluation report ESR-1463. • The design, installation, conditions of use and identification are in accordance with the 2015 International Building Code° (2015 IBC) and 2015 International Residential Code° (2015 IRC) provisions noted in the evaluation report ESR-1463. • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, or LARC Chapter 3, as applicable. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must not be installed over existing wood shakes or wood shingles in accordance with LABC Section 1511. • The installation of the Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must comply with City of Los Angeles Information Bulletin P/BC 2014-16, "Dwellings in High Wind Velocity Areas(HWA)". • Reroofing applications must comply with Sections 4.2.2,4.3.2 and 5.7 of the evaluation report ESR-1463 and LABC Section 1511 or LARC Section R908, as applicable. Where spaced sheathing exists, a minimum of 15/32-inch-thick (11.9 mm)plywood shall be installed prior to roofing installations. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not.specifically addressed,nor are they to be construed ANSI as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as anw to any finding or other matter in this report,or as to any product covered by the report. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 12 of 14 ESR-1463 LABC and LARC Supplement I Most Widely Accepted and Trusted Page 13 of 14 • Where moderate or heavy foot traffic occurs for maintenance of equipment,the roof covering shall be adequately protected. • The Building Inspector shall be notified 24 hours in advance prior to installation of the roof membranes. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2015 International Building Code®(IBC)provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the LABC. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2015 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.3.1 and R337.5 of the LARC. This supplement expires concurrently with the evaluation report, reissued October 2020. ESICC EVALUATION SERVICE ICC-ES Evaluation Report ESR-1463 CBC and CRC Supplement Issued October 2020 This report is subject to renewal October 2021. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS,A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Carlisle EPDM, PVC and TPO single-ply roofing membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2019 California Building Code(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)and Division of State Architect(DSA), see Sections 2.1.1 and 2.1.2 below. • 2019 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CBC Chapter 15, provided the design and installation are in accordance with the 2018 International Building Code®(IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CRC Chapter 95, provided the design and installation are in accordance with the 2018 International Residential Code®(IRC)provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed AN.S1 as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i w I„ to any finding or other matter in this report,or as to any product covered by the report. tI ,o. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 14 of 14