HomeMy WebLinkAboutFile Documents.11 E Water Pl.0044-2023-BROF (11) CITY OF ASPEN /
PERMIT NO.DD34-2023-BROF e �— Field Plan Set Must Be Printed In Color /►���
Existing gutter to be1321 ICt `'/ /
Existing gutter to be
replaced Ilk'for Ilk'. p - * EVALUATION �',';I
OWNER 0 re laced like for likeIr
Downspout to J EVALUATION
MAGNUSON RICK ♦ landscaping A i
ADDRESS,0
wo Extent of proposed . , 0 F0jiltilt
10 E WATER PL Hardscape walkway work _ Existing downspout r, xl CITY OF
- - 'to be replaced like
PARCEL IDlandscaping
for Drains to
273513204010 �� a dscaP rig - , Complance wan Co e s codes ASPEN
All areas not called ❑ • Compliance wan Slate Codes
out as hardscape .
are landscaping ll����
APPLICATION ACCEPTED DATE: 2023-04-26 PERMIT NUMBER: 0034202}BROF ,�J 60 , ' www.icc-es.orq I (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council'' These plans muff eMs pt at the
r i��i'_11 E building site or inspection
Existing gutter t°oe delays may occur.Construction
. - y ICC-ES Evaluation Report RessuedJanuary2023 shall conform to these plans.All
4� Existing downspout 'replaced like for like
COMMUNITY DEVELOPMENT DEPARTMENT t(101 to be replaced like - Snow stops required at all locations ESR-1389 This report is subject to renewal January 2024. changes shall be approved by
14/00 Y�
for like.Drains to
IQ/ where roofs could shed snow onto IfiligIng official.
BUILDING PERMIT COVERSHEET landscaping walkways,stairs,alleys,decks,exits,
CITY OF ASPEN F, 1Sf
DIVISION:07 00 00—THERMAL AND MOISTURE with asphalt onthe
born skies,and surfaced with mineral roofing
utilities and meters,emergency escape PROTECTION granules on tue weather side and a mineral release agent
'
and rescue opening window wells,or Section:07 31 13—Asphalt Shingles on the back side. SEPARATE PERMITS ARE
PROPERTY INFORMATION �/ adjacent properties-IBC 1513/COA
ADDRESS 10 E WATER PL UNIT 10 r 8.20.020(z). REPORT HOLDER: 3.3 Laminated Shingles: REQUIRED FOR ELECTRICAL,
PARCEL ID: 273513204010 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE v Laminated shingles,including two-layer laminated,three- PLUMBING,MECHANICAL,OR
HOUSING
' • Heat trace/tape must be self-regulating CERTAINTEED LLC layer laminated and In-laminate laminates shingles, are FIRE SPRINKLER WORK
OWNER. MAGNUSON RICK el, type cable and must include automatic composed of multiple thicknesses of coated and surfaced
PERMIT CONTRACTOR: CITY OF ASPEN-ASSET MANAGEMENT controls and timer capable of turning EVALUATION SUBJECT: fiberglass mat,cut and bonded together n different patterns. SMOKE ALARMS AND
itAoff the system when the outdoor The weather side is surfaced with mineral roofing granules. CARBON MONOXIDE
Lem erature is above 50 de rees and CERTAINTEED ASPHALT SHINGLES and the back side is surfaced with a mineral release agent.P 9 a9 DETECTORS REQUIRED
DESCRIPTION OF WORK :The existingduring daylight hours. THROUGHOUT DWELLING
asphaltshingle reels al to-11E Water Place have reached the of their usable life.Theexisting 1.0 EVALUATION SCOPE 3.4 Accessory Shingles: UNIT PER CITY OF ASPEN
roofs are approximately 25 years old.Project scope will include removal and disposal of the misting roof 11 Compliance with the following Codes:
•2021,2018,2015.2012 and 2009 International Building 3.4.1 Hip and Ridge Shingles:Hip and ridge shingles are
assembly,and installation of a new roof assembly. MUNICIPAL CODE 8.15
factory-made shingles to be used for covering hips and
P lam. (IBC) ridges.The hip and edge shingles are composed of the
i_� — tsame materials as the root shingles.Some of the hip and
•2021, 2018, 2015. 2012 and 2009 lntemalional
t Hardscape walkway ' t Residential Code'(IRC) ridge shingles have perforations that extend from the lop of
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? - t the cut-out to the top of the shingle,which facilitate theIll
It should be known that this review shall
-A ■2013 Abu Dhabi International Building Coda(ADIBC) tearing of the shingle into three or four equal pieces.Others
,The- N ,e ADIBC is based en the 2009 IBC.2009 IBC code sections referenced are manufactured as single hip and ridge units not relieve the applicant of their
CLASS OF WORK Residential FIRE SPRINKLER TYPE AlIn B,is repod a,a the serve•ectiona in the ADIBC. responsibility to comply with the
l , 4'� Properties evaluated: 3.4.2 Starter Strip Shingles:Starter Strip shingles are requirements of the City of Aspen
Existing gutter& ,1Allik fit ; { factory-made shingles to be used as the starter course Municipal Code.Pursuant to
■Weather resistance p
REQUIRED SPECIAL downspout to be Ex�seng gutter& (under the first course of roof shingles).The Starter Strip Sec.26.104.050,anypermit or approval
BUILDING TYPE(IRC) replaced like for like. ' ■Fire classification shingles are composed of the same materials as the roof pp INSPECTIONS P ,, downspout to be fg p0
Drains to �' ` replaced like for like. Site Plan shingles.The shingles are supplied in 7-Inch-b 36-inch- issued in error or otherwise not in
landscaping ,� � igh, Drains to 0 Roof Replacement ■Wind resistance n9 rigy- conformity with the requirements of this
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE 1 landscaping 110-11 EWater PL 2.0 USE- long(178 by 914 mm): 10-inch-by-36-inch-long(254 by
p e 914 mm);or 7-inch-by-39°Ie-inch-long(178 by 1000 mm) Title,shall be void.Similarly,any permit
-• - e CertainTeed asphalt shingles described in this report :pips. As an alternative to factory-made starter strips• or approval issued in reliance upon or
WORK CHANGES BUILDING comply with ASTM D3462 and are Class A roof covenngs -enter strips can be formed by removing the lower tab as a result of,a materially false
OCCUPANCY GROUP(IBC) WORKOIAN :n installed as described in this report. portions of the factory-made shingles except for the statement or representation made in
FOOTPRINT?
- 3.0 DESC• • • Presidential Shake and Presidential Shake TL shingles For the process of obtaining the permit or
Presidential Shake and Presidential Shake TL shingles.the development approval shall,likewise,
coDEEo imoNs xoL51Rc TOTAL SPASQFT. 3.1 General: P PP
Presidential Starter shingles consist of one 13 a nch-wide- be void.Any person having received a
CertainTeed asphalt shingles are available as Three-lab, by-40-inch-long(337 mm by 1016 mm)base shingle and
four-tab, no cutout and laminated asphalt shingle roof one 11'!a-inch-wide-by-40-inch-long(286 mm by 1016 mm) void or voidable permit or approval
OTHER CODE EDITIONS TOTAL SNOW ME LT SOFT. covering materials.See Table 1 and Figure 1 for recognized base shingle. shall not be relieved from having to
product names, shingle types, manufacturing locations, comply with all applicable terms and
overall dimensions,installed weights,maximum exposure to 3.5 Fasteners: conditions of this Title and the City shall
HISTORIC PROPERTY? No TOTAL POOL SQ.FT. the weather,and fastening details-The shingles are self- Fasteners must comply with ASTM F1667 and must not be estopped from fully enforcing
sealing by means of adhesive strips located on either the same.
,a,x.am.r•afa no m.,Inrt.reld. c..Fleece 1 ten•el..•.,.. be minimum No.12 gage(0.105-inch (2-67 min)
FIRE SPRINKLER EXISTING? I
Roof Assembly Listed Below
APPLICATION ACCEPTED DATE: 2023-04-26 PERMIT NUMBER: 0044-2023-BROF iR� s,,,lt,;;,,y,r�. i
�f t1 05U/J{1001 133//22 0 2C33.
COMMUNITY DEVELOPMENT DEPARTMENT ,` / C
FOICUMINICE
00
BUILDING PERMIT COVERSHEET Y
CITY OFAVEr4 2 Proposed Roof Assembly Drawing— Show all layers/components from the roof sheathing up. Each component must k linzhid
PASP
PROPERTY INFORMATION product and manufacturer name and existing to remain components and number of layers. Show flashing and ice baI
ADDRESS: 11E WATER PI UNIT: ® Existing roofing and number of layers: 3 layers: 3/411 CDX ply, #15 bldg. paper, asphalt shingles
PARCEL ID: 273513204011 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE
HOUSING
OWNER. KUNE KYLE
PERMIT CONTRACTOR: 3G Construction&Roofing
DESCRIPTION OF WORK NOTE:All permit fees were paid and review approved part of 0034-2023-8ROF's permit process.Application was
duplicated to reflect separate addresses.
:The existing asphalt shingle roofs of 10-11 E Water Place have reached the end of their usable life.The existing
roofs are approximately 25 years old.Project scope will include removal and disposal of the existing roof
assembly,and Installation of a new roof assembly.
I—
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED?
•
CLASS OF WORK Residential FIRE SPRINKLER TYPE
BUILDING TYPE(IRC) REQUIRED SPECIAL
INSPECTIONS
CITY'OF ASPEN
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE
PERMIT NO.0044-2023-BROF
OCCUPANCY GROUP(IBC) WORK CHANGES BUILDING
FOOTPRINT? OWNER KLINE KYLE
•
CODE EDITIONS 2015IRC TOTAL SPA SQ.FT. ADDRESS 11 E WATER PL
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. PARCEL ID 273513204011
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING?