HomeMy WebLinkAboutFile Documents.13 E Water Pl.0045-2023-BROF (11) CITY OF ASPEN
Field Plan Set Must Be Printed In Color �1►�
PERMIT NO.0033-2023-BROF _ _ 11 ' am,� 11CC
\` 1'�
t_ EVALUATION ',�,
OWNER TERRY TRINITY&TRACY R ` SERVICE'
ADDRESS Hardscape walkway
12 E WATER PLS\ • .
/� 1 _ CITY OF
PARCEL ID All areas not calledh ` ASPEN
273513204012 out as hardscape •x •
Compliance with mbrrYomW Codes
• are landscaping • • O' .w. • ealpWce with Sect Codes
Existing gutter to be
��f'PLICATION ACCEPTED DATE: 2023-04-26 PERMIT NUMBER: 0033 2023 RROF �� replaced like for like. I (800)423-6587 • These plans site o e act at the
Downspout to wwW.icc es.ora I (562)699-0543 A Subsidiary of the Infemationa/Code Council
r. building or inspection
_•. landscaping
e al
delays may occur.Construction
ICC-ES Evaluation Report Reissued January 2023 shall conform to these plans.All
COMMUNITY DEVELOPMENT DEPARTMENT ,40,0k ESR-1389 This report is subject to renewal January 2024. changes shall be approved by
14 Ifiliging official.
BUILDING PERMIT COVERSHEET ` •'
cmOFAS ILIA
Existing downspout to be DIVISION:07 DO 00—THERMAL AND MOISTURE with asphalt on both sides.and surfaced with mineral roofing
J - replaced like for like.Drains PROTECTION granules on the weather side and a mineral release agent
Existing gutter to be r 12 to landscaping
replaced like for like Section:07 31 13—Asphalt Shingles on the back side- SEPARATE PERMITS ARE
PROPERTY INFORMATION
REPORT MOLDER: 3.3 Laminated Shingles: REQUIRED FOR ELECTRICAL,
ADDRESS 12 E WATER PL UNIT Existing gutter for like be PLUMBING,MECHANICAL,OR
PARCEL ID: 273513204012 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE replaced like Laminated shingles.including two-layer laminated,three- FIRE SPRINKLER WORK
CERTAINTEED LLC layer laminated and tri-laminate laminated shingles. are
HOUSING Existing downspout to be _ composed of multiple thicknesses of coated and surfaced
OWNER. TERRY TRINITY&TRACYR replaced like for like.Drains
PERMIT CONTRACTOR: CITY OF ASPEN-ASSET MANAGEMENT to landscaping 13 - • 1 Extent of proposed EVALUATION SUBJECT: fiberglass mat,col and bonded together in Pelham.. SMOKE ALARMS AND
I, 4 work The weather side is surfaced with mineral roofing granules. CARBON MONOXIDE
♦♦♦ — ---III.
-. --� CERTAINTEED ASPHALT SHINGLES and the back side is surfaced with a mineral release agent. DETECTORS REQUIRED
e3.4 Accessory Shingles: THROUGHOUT DWELLING
1.0 EVALUATION SCOPEory 9
DESCRIPTION OF WORK :The existing asphak shingle roofs of 12-13 E Water Place have reached the end of their usable life,The existing Existing downspoutUNIT PER CITY OF ASPEN
roofs are approximately 25 years old.Project scope will include removal and disposal of the misting roof - • f to be replaced like Compliance with the following codes: 3.4.1 Hip and Ridge Shingles:Hip and ridge shingles are MUNICIPAL CODE 8.15
S. for like.Drains to •2021,2018,2015.2012 and 2009 International Building factory-made shingles to be used for coveting hips and
assembly,and installation of a new roof assembly. Y _ • patio Coda°(IBC) ridges.The hip and ridge shingles are composed of the
404116 -tH. ,
�1 - -a same materials as the roof shingles,Some of the hip and
• I ■2021, 2018. 2015. 2012 and 2009 International
,I Hardscape patio ridge shingles have perforations that extend from the top of
1 Residential Code'(IRC)
- . the cut-out to the top of the shingle.which facilitate the
• —y Y� ■2013 Abu Dhabi International Building Code(ADIBC)' tearing of the shingle Into three or four equal pieces.Others It should be known that this review shall
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? 711-3.../ • 7 not relieve the applicant of their
► rThe colec is based on the 2009 IBC.2009 IBC cede...coons rererenced are manufactured as single hip and ridge units pp
A V_laJ lo this repsere masame secuo�mmeADlec responsibility to comply with the
Properties evaluated: 3.4.2 Starter Strip Shingles:Starter Strip shingles are requirements of the City of Aspen
E Snow stops required at all locationsfactory-made shingles to be used as the starter course
CLASS OF WORK Residential FIRE SPRINKLER TYPE ■Weather resistanceMunicipal Code.Pursuant to
• where roofs could shed snow onto (under the first course of roof shingles).The Starter Strip
at I Sec.26.104.050,any permit or approval
Ili . walkways,stairs,alleys,decks,exits, •Fire classification shingles are composed of the same materials as the roof issued in error or otherwise not in
REQUIRED SPECIAL utilities and meters,emergency escape I •Wind resistance shingles.The shingles are supplied in 7-inch-by-36-inch- conformitywith the requirements of this
BUILDING TYPE(IRC) and rescue opening window wells,or long(178 by 914 min): 10-inch-by-36-inch-long 254 by q
INSPECTIONS I ' P 9 2. 9( Title,shall be void.Similarly,anypermit
adjacent properties-IBC 1513/COA 914 mm);or 7-inch-by-39'/a-inch-long(178 by 1000 min)
A,18.20.020(z). The CertainTeed asphalt shingles described in this report strips. As an alternative to factory-made starter strips- or approval issued in reliance upon or
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE • e y _ • F comply with ASTM D3162 and are Class A roof coverings starter strips can be formed by removing the lower tab as a result of,a materially false
# , 1 n installed as described in this report. portions of the factory-made shingles except for the statement or representation made in
4 , Heat trace/tape must be self-regulating - 3.0 DESCRIPT Presidential Shake and Presidential Shake TL shingles.For the process of obtaining the permit or
WORK CHANGES BUILDING - A • 41 type cable and must include automatic Presidential Shake and Presidential Shake TL shingles.the development approval shall,likewise,
OCCUPANCY GROUP IIBC) 3.1 General: P PP
FOOTPRINT? controls and timer capable of turning Presidential Starter shingles consist of one 13'/c-inch-wide- be void.Any person having received a
off the system when the outdoor CertainTeed asphalt shingles are available as three-tab, by-40-inch-long(337 mm by 1016 mm)base shingle and
temperature is above 50 degrees and four-tab, no cut-out and laminated asphalt shingle roofvoid or voidable permit or approval
CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. p g coveringmaterials.See Table 1 and Figure 1 for recognized baseons 11'inglers-wide-wide -inch-long(286 min by 1016 mm) shall not be relieved from having to
during daylight hours. 9 a shingle. applicable names. shingle types, manufacturing locations. comply with all terms and
overall dimensions,installed weights,maximum exposure to 3.5 Fasteners: conditions of this Title and the City shall
OTHER COOS EDITIONS TOTAL SNOWMELT SQ.FT. the weather,and fastening details-The shingles are self- Fasteners must comply with ASTM F1667 and must not be estopped from fully enforcing
sealing by means of adhesive strips located on either the same.
wool..r owls nix lbw nnel.rel.1a caw cle,en t r wth.er.ra be minimum No.12 gage[0.105-Inch-diameter(2-67 min)
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
Roof Assembly Listed Below
FIRE SPRINKLER EXISTING?
05/03/2023 91
APPLICATION ACCEPTED DATE: 2023-04-26 PERMIT NUMBER: 0045-2023-BROF FORCIOat GUIRPLIANCE
linzhid
COMMUNITY DEVELOPMENT DEPARTMENT N`1i% 0 Proposed Roof Assembly Drawing—Show all layers/components from the roof sheathing up. Each component must k
01,1
BUILDING PERMIT COVERSHEET i�►► product and manufacturer name and existing to remain components and number of layers. Show flashing and ice bai
cINOFASPENJ ® Existing roofing and number of layers: 3 layers: 3/4" CDX ply, #15 bldg. paper, asphalt shingles
PROPERTY INFORMATION
ADDRESS: 13 E WATER PL UNIT:
PARCEL ID: 273513204013 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE
HOUSING
OWNER: FABROCINI ROBERT
PERMIT CONTRACTOR: 3G Construction&Roofing
DESCRIPTION OF WORK NOTE:All permit fees were paid and review approved part of 0033-2023-BROF's permit process.Application was
duplicated to reflect separate addresses.
:The existing asphalt shingle roofs of 12-13 E Water Place have reached the end of their usable life.The existing
roofs are approximately 25 years old.Project scope will Include removal and disposal of the existing roof
assembly,and installation of a new roof assembly.
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED?
CLASS OF WORK Residential FIRE SPRINKLER TYPE
BUILDING TYPE(IRC) REQUIRED SPECIAL
INSPECTIONS CITY OF ASPEN
•
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE PERMIT NO,.0045-2023-BROF
WORK CHANGES BUILDINGOWNER
OCCUPANCY GROUP lied FABROCINI ROBERT
FOOTPRINT?
CODE EDITIONS 2015IRC TOTAL SPA SQ.FT. ADDRESS.13 E WATER PL
OTHER CODE EDIONS TOTAL SNOWMELT SQ.FT. PARCEL ID 273513204013
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING?