HomeMy WebLinkAboutFile Documents.155 Miners Trail Rd.0068-2022-BCHO (3) 1280 Park Center Drive Vista, California 92083 760-598-6464 Fax 760-598-8908 www.hotspring.com Thursday, July 21, 2022 RE: Portable Electric Hottub Permit: Caldera Niagara To whom it may concern, The surface are the water in a Cadera Niagara spa is is 5360 sq. in. (37.2 sq. ft). Respectfully, Mike McCague Senior Engineer Watkins Manufacturing Corporation 1280 Park Center Drive Vista, CA 92081, U.S.A. Tel: +1 760 305 4137 Fax: +1 760 598 8670 09/12/2022 01/04/2023 jimp Caldera CoC 60Hz 121 CERTIFICATION OF COMPLIANCE Product Caldera Spas (60Hz) Model and Serial # Cantabria CABXXD121XXXX Geneva GEBXXD121XXXX Kauai KAAXXD121XXXX Tahitian TABXXD121XXXX Salina SAAXXD121XXXX Makena MAAXXD121XXXX Martinique MRAXXD121XXXX Niagara NIBXXD121XXXX Florence FLBXXD121XXXX Provence PRBXXD121XXXX Seychelles SEYXXD121XXXX Reunion REUXXD121XXXX Aventine AVHXXD121XXXX Palatino PLTXXD121XXXX Marino MRNXXD121XXXX Tarino TARXXD121XXXX Vanto VNTXXD121XXXX Celio CELXXD121XXXX Applicable Standards & CPSC Regulation(s) Public Law 110-140 Title 16 Sec. 1401-1404 – Virginia Graeme Baker Act UL 1563 – Electric Spas, Equipment Assemblies, and Associated Equipment CAN/CSA-C22.2 No. 218.1 – Spas, Hot Tubs, and Associated Equipment ASTM F 1346-91 – Standard performance Specification for Safety Covers and Labeling Requirement for All Covers for Swimming Pools, Spas, and Hot Tubs ANSI/APSP 16 – Suction Fittings for Use in Swimming Pools, Wading Pools, Spa, and Hot Tubs. ANSI Z124.7 – Uniform Swimming Pool, Spa, and Hot Tub Code CEC Title 20 – California Energy Commission Appliance Efficiency – Portable Spas APSP-14 – Portable Electric Spa Energy Efficiency Standard APSP-6 – Standards for Portable Spas Marks ETL, UPSC, UL (Cover) Manufacturer Watkins Manufacturing Corp 1280 Park Center Dr. Vista CA, 92081 Phone: (760) 305-4137 Individual Maintaining Records of Compliance Mike McCague Watkins Manufacturing Corp 1280 Park Center Dr. Vista CA, 92081 Phone: (760) 305-4137 Manufacturing Information Manufactured in January – March 2021 in Tijuana, Mexico. Testing Information Test data and other relevant information evaluated for compliance with Public Law 110-140 Title 16 Sec. 1401-1404 on January 1, 2021 by Watkins Manufacturing Corp. Watkins Manufacturing Corp is a longstanding provider of quality products that meet or exceed regulatory requirements with respect to consumer product safety. Watkins Manufacturing Corp has engaged in a program to document conformity with all applicable regulations, bans, standards and other requirements administered by the Consumer Product Safety Commission (CPSC). Information on our conformity assessment efforts, along with all General Conformity Certificates, is available upon request. Third-Party Laboratory Information Intertek ETL 25791 Commercentre Dr Lake Forest CA, 92630 949-448-4100 IAPMO R&T 5001 East Philadelphia St Ontario, CA 91761 909-472-4100 UL 2929 E. Imperial Highway Suite 100 Brea, CA 92821-6729 714-223-3600 09/12/2022 01/04/2023 jimp Watkins Manufacturing Corporation 1280 Park Center Drive Vista, CA 92081 Telephone 760 598-6464 Facsimile 760 598-6752 www.hotspring.com Spa Dealer and Owner, August 15, 2012 RE: Spa compliance with International Residential Code barrier requirements and Energy Conservation Code Requirements All spas manufactured by Watkins Manufacturing are equipped with a locking safety cover and meet the local barrier fence requirements per IBC and IRC. Approved safety covers are tested, certified, and UL marked for compliance with ASTM F 1346-91: Standard performance Specification for Safety Covers and Labeling Requirement for All Covers for Swimming Pools, Spas, and Hot Tubs. The markings are imprinted on the side of the cover adjacent to the handle. Safety covers not bearing the UL mark for ASTM F1346-91 will need to be replaced. These covers meet the barrier requirements when properly installed on the spa. This includes traditional installation when a spa is above grade and the cover is secured to the spa as well as when the spa is installed below grade or recessed and the cover is secured to the spa or adjacent deck with the supplied locks. Per the Energy Conservation Code, all covers produced by Watkins Manufacturing have an insulation value of R-14. These covers are required to achieve the energy consumption rating provided in the Appliance Efficiency Database per the California Energy Commissions Title 20 regulations. Marking Reference: Michael McCague Compliance Engineer Watkins Manufacturing Corporation 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements. Remember to carefully read the Owner’s Manual that accompanies your spa and to complete the warranty card within ten days of delivery. These items, along with other valuable information, are included in the Owner’s Packet which can be located in the equipment compartment of your spa. You will also find your serial number in the equipment compartment. Watkins Wellness™ reserves the right to change features, specifications, and design without notification and without incurring any obligation. DATE PURCHASED: _________________________________________________________________ DATE INSTALLED: ___________________________________________________________________ DEALER: ___________________________________________________________________________ ADDRESS: __________________________________________________________________________ TELEPHONE: _______________________________________________________________________ In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and spa enclosures). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your Caldera® spa is equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers, and as a result, is usually exempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your CALDERA dealer can provide information on which permits may be required. Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of CALDERA spa owners. Utopia ® Series 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 2 SITE SELECTION AND PREPARATION IMPORTANT: Site selection and preparation are your responsibility. Carefully read these instructions and consult your authorized CALDERA dealer if you have any questions. You probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or on a deck. Just make sure you check the following: • Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose can support the weight of your filled spa. • Locate your spa away from any reflective surface or glass. The heat generated by some types of double- pane windows and reflective surfaces can cause serious damage to the exterior of the spa, including the siding and cover. • Don’t forget to level your spa (see the Ground and Spa Leveling Preparation section on the next page). • Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house’s circuit breaker. • Leave yourself easy access to the circuit breakers in the subpanel. • Never let water get into the subpanel. Your 230 volt spa’s subpanel is raintight when installed correctly with the door closed. • Leave access to the entire front of the spa (the removable panel provides access to the spa’s equipment) for periodic spa care and maintenance. INDOOR/BASEMENT INSTALLATION Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa, it is recommended that a floor drain be installed. The humidity will naturally increase with the spa installed. Water may get into woodwork and produce dry rot, mildew, or other problems. Check for airborne moisture’s effects on exposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed. CALDERA spas are equipped with a jet pump shroud to remove excessive heat from the equipment compartment. Find this vent, and be sure it is not blocked by anything, including carpeting. Your CALDERA dealer can help you with local information such as zoning regulations and building codes. DECK INSTALLATION To be certain your deck can support your spa, you must know the deck’s maximum load capacity. Consult a qualified building contractor or structural engineer before you place the spa on an elevated deck or indoors. To find the weight of your spa, its contents and occupants, refer to the Spa Specification chart (on back cover). This weight per square foot must not exceed the structure’s rated capacity, or serious structural damage could result. OUTDOOR AND PATIO INSTALLATION No matter where you install your new spa, it’s important that you have a solid foundation to support it. Structural damage to the spa resulting from incorrect installation or placement on an inadequate foundation is not covered under the spa’s limited warranty. (See next page for specifics) GROUND AND SPA LEVELING PREPARATION Your CALDERA spa has been engineered to perform on several types of common yard surfaces. While a concrete slab is best for long-term use*, other foundations are acceptable as long as a level base is prepared prior to delivery. 09/12/2022 01/04/2023 jimp Page 3 *NOTE: A reinforced concrete pad at least 4 inches (10 cm) thick or structurally sound deck able to support the “dead weight” found in the spa specification chart for each model (see back page).The reinforcing rod or mesh in the pad should be attached to a bond wire. • Concrete sloped at 1/2 inch (1.5 cm) per 10 feet (3 m) is preferred so that rain water and water spillover will run off and not puddle underneath the spa. • If brick or wood decking is selected for the spa foundation, it should be placed and leveled below the entire spa to maintain even distribution of the spa weight. • It is important to note that if bricks are used to distribute the weight of the spa there may still be a tendency to settle unevenly, resulting in an unlevel spa. • Remember, placing the spa around grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user’s feet. If you are purchasing a deck package or a spa enclosure with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are a few of the recommended surfaces. As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites. Shimming or point leveling is NOT supported or recommended by the manufacturer. If you are interested in having a concrete slab, brick surface, or wood deck installed, your CALDERA dealer should be able to suggest a qualified, licensed contractor. DELIVERY ACCESS First, locate the dimensions of your spa on the chart that is found on the next page. The dimensions shown are the measurements of the spa in the vertical position, laid on its side. Next, contact your dealer to find the height and width added by the delivery cart which the dealer will use to deliver your new spa. Use the height of the cart plus the dimension shown as H to determine the vertical clearance required to pass the spa and cart. Use the width of the cart, or dimension W, whichever is greater, to determine the maximum width of clearance necessary. Use the length dimension L when making any sharp turns to determine the maximum clearance required. NOTE: It is strongly recommended to keep the spa in its original factory protective packaging particularly when loading, moving or handling the spa in a vertical position. It may be necessary to allow for additional over-head clearance if the spa will be rolled up or down an incline or moved up or down a short flight of stairs. Use the information in the picture on next page to determine the requirements for access to your desired location. It may be necessary to remove a gate, part of a fence, or other movable obstructions in order to roll the spa to its installation site. About ten percent of the time, a crane is the only way to install the spa by lifting it to its final destination. CONCRETE PADS BRICK SURFACES WOOD DECKING FOUNDATIONS FOR SPAS WITH GAZEBOS 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 4 If the spa has to be taken off of the cart to go over a wall (either because the entry area is too narrow, the eaves are too low, the corner is too tight, or the stairway is too steep), a crane will be required. Don’t be alarmed! The crane has a truck-mounted boom which can fit right in your driveway. It is run by a licensed and insured operator. For a charge, the crane operator will lift your spa over walls, buildings, or any other obstruction and place it as close to the installation site as possible. The CALDERA spa delivery personnel will supervise the crane delivery and complete the spa installation. If your spa delivery requires the use of a crane, you may be required to pay for its services at the completion of the delivery SPA DIMENSIONS Model Width (W)Length (L)Height (H) CANTABRIA 38" (97 cm)9' 0" (274 cm)7' 7" (231 cm) GENEVA 38" (97 cm)7' 5" (226 cm)7' 5" (226 cm) NIAGARA 38" (97 cm)7' 5" (226 cm)7' 5" (226 cm) TAHITIAN 36" (91 cm)7' 0" (213 cm)7' 0" (213 cm) FLORENCE 36" (91 cm)7' 0" (213 cm)7' 0" (213 cm) RAVELLO 33" (84 cm)7' 0" (213 cm)5' 6" (168 cm) How is your width and height clearance? Protruding electric meters A/C units Do you have sufficient overhead clearance? Check low roof eaves, overhanging branches, rain gutters Is the path clear? Move away branches, dog houses, firewood, etc. If there is a 90 turn, can we clear it? (The spa will not bend) No more than 6 consecutive stairs without a landing Gas meters Check all gates HOUSE BACK YARD STREET 09/12/2022 01/04/2023 jimp Page 5 Pre-Delivery Instructions NOTE: WATKINS WELLNESS requires that the CANTABRIA be installed on a minimum 4" (10 cm) thick reinforced concrete pad or structurally sound deck able to support the “dead weight” found in the spa specification chart. WARNING: The CANTABRIA must not be shimmed in any manner. CANTABRIA NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Configuration and location may change without notice. 108.0” (274 cm) 38” (97 cm) 30.25” (77 cm) 102.0” (259 cm) 85.125” (216 cm) Cantabria 95” (241 cm) 13” (33 cm) 91” (231 cm) 4” (10 cm) (Front View) Door Opening Drain (Center of Spa) Electrical Cut-Out (both sides) 3" (7.6 cm) up from bottom of spa (Bottom View) Air VentDo Not Block Air Vent Do Not Block Air Vent Do Not Block Base PanSide Walls Base Pan Side Walls DOOR SIDE Electrical Cut-Out (both sides) Front Door Panel 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 6 Niagara & Geneva 89” (226 cm) 30.25” (77 cm)38” (97 cm) 83.5” (212 cm) 83.5” (212 cm) 76.5” (194 cm) 13” (33 cm) 4” (10 cm) 89” (226 cm) NOTE: WATKINS WELLNESS recommends that the GENEVA and NIAGARA be installed on a minimum 4” (10 cm) thick reinforced concrete pad or structurally sound deck able to support the “dead weight” found in the spa specification chart. WARNING: The GENEVA and NIAGARA must not be shimmed in any manner. GENEVA and NIAGARA NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Configuration and location may change without notice. Pre-Delivery InstructionsNiagara & Geneva 89” (226 cm) 30.25” (77 cm)38” (97 cm) 83.5” (212 cm) 83.5” (212 cm) 76.5” (194 cm) 13” (33 cm) 4” (10 cm) 89” (226 cm) Front Door Panel (Front View) Drain (Center of Spa) (Bottom View) Air Vent Do Not Block Air Vent Do Not Block Air Vent Do Not Block Base Pan Side Walls Base Pan Side Walls DOOR SIDE Electrical Cut-Out (both sides) Electrical Cut-Out (both sides) 3" (7.6 cm) up from bottom of spa 09/12/2022 01/04/2023 jimp Page 7 TAHITIAN and FLORENCE NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Configuration and location may change without notice. NOTE: WATKINS WELLNESS recommends that the TAHITIAN and FLORENCE be installed on a minimum 4” (10 cm) thick reinforced concrete pad or structurally sound deck able to support the “dead weight” found in the spa specification chart. WARNING: The TAHITIAN and FLORENCE must not be shimmed in any manner. 84.0” (213 cm) 36” (91 cm)28.25” (72 cm) 78.25” (199 cm) 78.25” (199 cm) TAHITIAN 71” (180 cm) 13” (33 cm) 84” (213 cm) 4” (10 cm) 84.0” (213 cm) 36” (91 cm)28.25” (72 cm) 78.25” (199 cm) 78.25” (199 cm) TAHITIAN 71” (180 cm) 13” (33 cm) 84” (213 cm) 4” (10 cm) Front Door Panel Air Vent Do Not Block (Front View) Base PanSide Walls Base Pan Side Walls DOOR SIDEAir Vent Do Not BlockAir Vent Do Not Block Drain (Center of Spa) Electrical Cut-Out (both sides) (Bottom View) Electrical Cut-Out (both sides) 3" (7.6 cm) up from bottom of spa 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 8 84.0” (213 cm) 25.25” (64 cm)33” (84 cm) 78.5” (199 cm) 61” (155 cm) Ravello 71” (180 cm) 13” (33 cm) 64.5” (164 cm) 4” (10 cm) RAVELLO NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Configuration and location may change without notice. NOTE: WATKINS WELLNESS recommends that the RAVELLO be installed on a minimum 4” (10 cm) thick reinforced concrete pad or structurally sound deck able to support the “dead weight” found in the spa specification chart. WARNING: The RAVELLO must not be shimmed in any manner. Door Opening 84.0” (213 cm) 25.25” (64 cm)33” (84 cm) 78.5” (199 cm) 61” (155 cm) Ravello 71” (180 cm) 13” (33 cm) 64.5” (164 cm) 4” (10 cm) Front Door Panel Air Vent Do Not Block Air Vent Do Not Block DOOR SIDE Air Vent Do Not Block Base Pan Side Walls Drain (Center of Spa) Electrical Cut-Out (both sides) Base Pan Side Walls Electrical Cut-Out (both sides) 3" (7.6 cm) up from bottom of spa 09/12/2022 01/04/2023 jimp Page 9 Locate the two buttons below the front panel. Push up and hold one of the buttons using an Allen wrench less than ¼" (6 mm) in width or small screwdriver into the center of the safety lock then pull the door panel slightly away from the spa next to that button location to completely disengage the bottom clip. Repeat procedure on second button. 1 1a Push Button then pull panel 1b Push Button then pull panel Main Control Panel Safety Lock 2a Pull 2b Pull 2 Pull (with slight force) on bottom left corner until panel un-clips followed by the right corner until panel un-clips. Clip Clip Clip 3a Light connector- Turn and pull to remove 3b Logo Light connector- Push in side clips and pull to remove 3 Pull bottom door panel away (using both hands spaced shoulder length apart) from each side of the spa center, this may require a slight amount of force because of the upper clips until they all un-clip. Lower panel to ground. Disconnect both the logo light and front light wires from door panel, then remove door panel from spa area and set in a cool shaded place. Remove foam to access. Backside of door panel NOTE: To replace the Door Panel see Door Panel Replacement page in the Owner's Manual. DOOR PANEL REMOVAL 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 10 ELECTRICAL REQUIREMENTS To ensure you will have an opportunity to use your spa soon after delivery, it is very important that the required electrical service has been installed. Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY.IMPORTANT: All electrical circuits must be installed by a qualified, licensed electrician. 230 VOLT INSTALLATION Your spa contains a control box designed to operate at 230V, 60Hz. Installation of a 50 amp. dedicated circuit is recommended. The control box must be hard wired directly to a subpanel protected by a Ground Fault Circuit Interrupter (GFCI). The subpanel containing GFCI breakers is included with the spa. IMPORTANT NOTE: All electrical connections to the control box must be accomplished by a qualified electrician in accordance with the National Electrical Code and in accordance with any local electrical codes in effect at the time and place of installation. All electrical connections must be made in accordance with the wiring information contained in this manual and on the back of the field wiring access panel of the control box. A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the subpanel. The equipment pack requires a MINIMUM of 112 volts per line under load. The grounding conductor must be at least #10 AWG. Your electrician should mount the subpanel in the vicinity of the spa but it should not be closer than 5 feet (1.5 m) from the spa water edge (NEC 680-38 to 41-A-3). INSTALLATION NOTE: After the spa has been installed, your electrician can connect the conduit from the subpanel to the spa’s control box and then complete the wiring connections in the control box. NOTE: Complete step-by-step Installation and wiring instructions for all models are included in the Owner’s Manual and with each sub-panel, which can be obtained from your dealer. WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and will void the warranty. 230 VOLT CONVERTED CANTABRIA (OPTIONAL) The CANTABRIA requires an additional 20 amp breaker in order to operate the heater at the same time as the lounge pump #3. This subpanel requires a 70 amp, single phase, 230 volt, four wire service (two line, one neutral, one ground). The ground wire must never be less than #10 AWG. Use NEC 250-122 (table) and local codes for more information. A minimum #6 AWG solid copper bond wire is also required. NOTE: Complete step-by-step Installation and wiring instructions for the CANTABRIA are included in the Owner’s Manual and with each sub-panel, which can be obtained from your dealer. SEE ABOVE FOR IMPORTANT ELECTRICAL INSTALLATION NOTES. 09/12/2022 01/04/2023 jimp Page 11 ** Refer to NEC 250-122 (table) *PROVIDED WITH SPA.NOTE: ALL WIRING SHOULD BE COPPER. ** Refer to NEC 250-122 (table) NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker. GENEVA, TAHITIAN, NIAGARA, FLORENCE & RAVELLO WIRING DIAGRAMS MAIN CONTROL PANEL 220-240 VAC WIRING ACCESS DOOR See page 9 for Door Panel Removal Instructions 220-240 VAC WIRING ACCESS DRAIN POWER CONNECTION ACCESS POWER CONNECTION To connect power to the spa, refer to “230 VOLT WIRING SCHEMATIC DIAGRAM” and “POWER CONNECTION ACCESS” illustrations. When supplying power, remove the equipment door. NOTE: The 230V wiring diagram is located on the inside of the Control Box Cover. 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 12 OPTIONAL CANTABRIA (CONVERTED) *PROVIDED WITH SPA.NOTE: ALL WIRING SHOULD BE COPPER. ** Refer to NEC 250-122 (table) NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker. Remove jumpers A from TB-1 *PROVIDED WITH SPA.NOTE: ALL WIRING SHOULD BE COPPER. ** Refer to NEC 250-122 (table) NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker. Power jumpers CANTABRIA WIRING DIAGRAMS 09/12/2022 01/04/2023 jimp Page 13 Strip wire insulation back ½” Entire stripped end of wire must be inside Terminal Block After step 6, pull on wire to ensure proper installation Remove screwdriver Install Stripped end of wire into Terminal Block Push top of screwdriver away from wire Terminal Block Insert screwdriver to engage cage clamp 4 6 1/2” 3 5 3 WIRE INSTALLATION FOR CONTROL BOX TERMINAL BLOCK Wire Installation Steps Refer to spa’s wiring diagram on back of Control Box Cover for proper wiring and jumper configuration! 09/12/2022 01/04/2023 jimp Pre-Delivery Instructions Page 14 SERVICES AVAILABLE FROM YOUR CALDERA SPA DEALER SERVICE COST Pre-Delivery site inspection _____________ Deliver spa to installation site _____________ Unwrap spa and haul away packaging material _____________ Set up spa _____________ Fill the spa with water _____________ Explain and test the spa’s operation: _____________ • Control panel functions • Set temperature control • Jet systems menu • Lighting • Auxiliary panel functions • Optional CALDERA Entertainment System Explain the safety features _____________ • GFCI • Heater high limit General spa operation & maintenance orientation _____________ Water quality and maintenance orientation _____________ Adjust the water’s pH, Total Alkalinity and Calcium Hardness _____________ Sanitize the water _____________ Inspect the spa cover, place on spa, and install cover locks _____________ Review winterizing instructions _____________ Review Owner’s Manual & complete Warranty Card _____________ Follow-up call _____________ In-store spa water analysis _____________ TOTAL COST _____________ 09/12/2022 01/04/2023 jimp Page 15 ADDITIONAL PRODUCTS AVAILABLE FROM YOUR CALDERA SPA DEALER • FreshWater ® Salt System Start-Up Kit • FreshWater Salt System Replacement Cartridges • Ozone Kit • Monarch Silver Cartridge Mineral Spa Sanitizer • Clean Screen® Pre-Filter • FreshWater Vanishing Act ® Calcium Remover • Replacement Filter Cartridges • FreshWater 5-way Test Strips • FreshWater Salt Test Strips • FreshWater MPS Test Strips • FreshWater Spa Salt • CoolZone™ - Check compatibility for specific models • Caldera ® Entertainment Systems • Avante™ Step to match the spa cabinet • Retractable cover system with clearance requirements: ProLift ® II - 24” (61 cm) Back & 3" (8 cm) side Clearance Required ProLift III - 24” (61 cm) Back & 3" (8 cm) side Clearance Required ProLift IV - 7” (18 cm) Back & 3" (8 cm) side Clearance Required NOTE: Special Cabinet Spacers are required to mount the ProLift II, ProLift III, and ProLift IV Cover Lifters to the cabinet. The ProLift, however, cannot be installed on Utopia spas. Only Caldera branded cover lifters will work on Utopia spas. CONTRACTOR SUGGESTIONS Electrician Name: ______________________________________________________________________________ Telephone: ______________________________________________________________________________ Name: ______________________________________________________________________________ Telephone: ______________________________________________________________________________ Masonry Name: ______________________________________________________________________________ Telephone: ______________________________________________________________________________ Name: ______________________________________________________________________________ Telephone: General Name: _____________________________________________________________________________ Telephone: _____________________________________________________________________________ Name: _____________________________________________________________________________ Telephone: _____________________________________________________________________________ NOTE: Actual clearance may vary depending on spa model and installation location. Check with dealer for further details. 09/12/2022 01/04/2023 jimp 1280 Park Center Drive Vista, California 92081 (800) 669-1881 extension 8432 ©2022 WATKINS WELLNESS. Caldera, Cantabria, Geneva, Niagara, Tahitian, Florence, Ravello, SpaGlo, ProLift and The Home Relaxation Specialists are trademarks of WATKINS WELLNESS. 62907.22 A (1/22) UTOPIA SPA SPECIFICATIONS CANTABRIA 7'7" x 9'0" 2.31 m x 2.74 m 38" 97 cm 100 square feet 4,000 615 gallons 2,325 liters 1310 lbs. 595 kg 7,840 lbs. 3,560 kg 130 lbs./ft² 680 kg/m² 230 volt, 50 or 70 amp Single phase GFCI protected circuit GENEVA 7'5" x 7'5" 2.26 m x 2.26 m 38" 97 cm 100 square feet 4,000 410 gallons 1,550 liters 1,000 lbs. 455 kg 5,470 lbs. 2,485 kg 120 lbs./ft² 590 kg/m² 230 volt, 30 or 50 amp Single phase GFCI protected circuit NIAGARA 7'5" x 7'5" 2.26 m x 2.26 m 38" 97 cm 100 square feet 4,000 400 gallons 1,525 liters 995 lbs. 450 kg 5,555 lbs. 2,535 kg 122 lbs./ft² 600 kg/m² 230 volt, 30 or 50 amp Single phase GFCI protected circuit TAHITIAN 7'0" x 7'0" 2.13 m x 2.13 m 36" 91 cm 100 square feet 4,000 375 gallons 1,425 liters 900 lbs. 410 kg 5,080 lbs. 2,315 kg 125 lbs./ft² 610 kg/m² 230 volt, 30 or 50 amp Single phase GFCI protected circuit FLORENCE 7'0" x 7'0" 2.13 m x 2.13 m 36" 91 cm 100 square feet 4,000 360 gallons 1,365 liters 875 lbs. 395 kg 4,925 lbs. 2,235 kg 120 lbs./ft² 585 kg/m² 230 volt, 30 or 50 amp Single phase GFCI protected circuit REVALLO 7'0" x 5'6" 2.13 m x 1.68 m 33" 84 cm 50 square feet 4,000 230 gallons 875 liters 800 lbs. 365 kg 3,245 lbs 1,480 kg 115 lbs./ft² 545 kg/m² 230 volt, 30 or 50 amp Single phase GFCI protected circuit Foo t p r i n t dim e n s i o n s Wat e r cap a c i t y Fille d w e i g h t * Ele c t r i c a l Req u i r e m e n t s Effe c t i v e filt e r a r e a Hei g h t Hea t e r (W a t t s ) Dry w e i g h t Dea d w e i g h t * CAUTION: WATKINS WELLNESS suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck. * NOTE: The “Filled weight” and “Dead weight” of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs [80 kg]). NOTE: For 30 amp conversion contact your local dealer. 09/12/2022 01/04/2023 jimp