Loading...
HomeMy WebLinkAboutFile Documents.1215 Snowbunny Ln.0063-2022-BRES (7)0063-2022-BRES_1215 Snowbunny Ln B_BuildingComment1 Subject: PlanCheck Page Label: 6 Author: justinh File Name: 90.Architectural Drawings.20220526.pdf Color: It appears that gross fire area for the entire building (not just unit B) exceeds 5000 sq.ft. The fire marshal may require the installation of fire sprinklers with this alteration if the interior demo allows for installation of sprinkler lines. Unless you can confirm that the total building fire area is less than 5000 sq.ft. we will mark that fire sprinklers are required, with the caveat that this may be waived pending a post demo inspection with the fire marshal. No plan revisions required. 90.Architectural Drawings.20220526.pdf (3) Subject: PlanCheck Page Label: 10 Author: justinh File Name: 90.Architectural Drawings.20220526.pdf Color: Show snow guards above all required locations (above parking, utility meters, and any other potentially occupied areas). Subject: PlanCheck Page Label: 12 Author: justinh File Name: 90.Architectural Drawings.20220526.pdf Color: Provide a class A roof asembly detail and associated documentation of class A assembly 123 C D 2.7 SHOWER CLOSET It appears that gross fire area for the entire building (not just unit B) exceeds 5000 sq.ft. The fire marshal may require the installation of fire sprinklers with this alteration if the interior demo allows for installation of sprinkler lines. Unless you can confirm that the total building fire area is less than 5000 sq.ft. we will mark that fire sprinklers are required, with the caveat that this may be waived pending a post demo inspection with the fire marshal. No plan revisions required. A4.011 A4.013 NEW STANDING SEAM METAL ROOFING A4.013 PREPARE ROOF FOR NEW FINISH Contractor must verify all dimensions on site before commencing work or preparing shop drawings. Do not scale drawings. Sheet number Sheet title Scale Project number 1" Sheet size 24"X36" Size check Project Address Notes & Legend Stamp # DescriptionDate © Bryan May Architecture LLC bryan may architecture+interiors © Bryan May Architecture LLC (BMA)The information and design intent contained within this document is the property of BMA. No part of this information may be used without the prior written permission of BMA. BMA shall retain all common law statutory and other reserved rights, including copyright thereto. www.bryanmayarchitecture.com 970.300.2086 1/4" = 1'-0" A2.23 2128 1215 SNOWBUNNY LN UNIT BASPEN, CO 81611 LINDEN LANE ROOF LEVEL PLAN SCALE: PLAN NORTH TRUE NORTH A2.23 1/4" = 1'-0" 1 PROPOSED - ROOF PLAN PLAN NORTH TRUE NORTH 2022.04.26 PERMIT SET Show snow guardsabove all required locations (aboveparking, utility meters,and any other potentially occupiedareas). EXAMPLE TEXT TO LEVELRE: PLANS BO CEILINGRE: RCP RE : S T R U C T EXAMPLE TEXT TO LEVELRE: PLANS BO CEILINGRE: RCP RE : S T R U C T PLYWOOD SHEATHING, RE: STRUCTURAL FLOOR FRAMING, RE: STRUCTURAL SUSPENDED FINISH CEILING, RE: FINISH SCHEDULE AND RCP FINISH MATERIAL. RE: FINISH SCHEDULE 5/8" GYPSUM WALL BOARD UNFACED SOUND BATT INSUL 1 1/8" WARMBOARD SHEATHING W/ HYDRONIC PIPING INSTALLED FLOOR FRAMING, RE: STRUCTURAL CEILING FINISH, RE: RCP MAPEI GRANIRAPID THIN-SET MORTAR OR APPROVED EQ. DECOUPLING MEMBRANE, SCHLUTER DITRA OR APPROVED EQ. THIN-SET MORTAR CERAMIC TILE UNFACED SOUND BATT INSUL TILE SHOWN (WOOD SIM) PLYWOOD SHEATHING FLOOR FRA STRUCTUR FINISH MAT INTERIOR F R-30 SPRA INSULATIO R-19 BATT 1/2" PLYWO WOOD SOF SCALE:A7.01 1 1/2" = 1'-0" R1 R1_roof_placeholder 1 SCALE:A7.01 1 1/2" = 1'-0" R2 R2_roof_placeholder 2 Provide a class A roofasembly detail and associateddocumentation of class A assembly BMA Response: Please add a note to the plans requiring a post-demo inspection by the fire marshal. Gross fire area for the entire duplex will exceed 5,000 sf. BMA Response: Snow guards added to roof plan on sheet A2.23. BMA Response: Roof assembly updated on Sheet A7.01. 07/29/2022