Loading...
HomeMy WebLinkAboutFile Documents.413 E Main St.0029-2023-BCOM (10)0029-2023-BCOM_413 E Main_BuildingComment1 Subject: PlanCheck Page Label: 17 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: A1.2 and A5.1 show roof drainage sloping to gutters in the middle/back half of the roof, this shows a gutter on the front of patio roof and all drainage sloping to it. Coordinate plans and confirm what the actual proposed drainage will be. 90.JingAspenArchPlans.20230511.pdf (9) Subject: PlanCheck Page Label: 18 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Heaters to be provided with occupant sensor or timer switch so that system is automatically de-energized when occupants are not present. Controls shall be configured to allow the system to operate for four hours max per day (Aspen IECC C403.13.1). Please note this on the plan. Subject: PlanCheck Page Label: 18 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Your S sheets are marked not for construction. The sheets stamped by your engineer still make reference to the removable wall panels that will not be approved. Your engineer will need to stamp sheets that outline framing req's and make no reference to removable wall panels. Subject: PlanCheck Page Label: 19 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Removable panels are not a part of your HP and planning approvals. Remove references to removable wall panels or enclosing of the patio in any way. Acknowledge that the applicant understands that no walls or enclosures other than the roof are approved, installation of any walls or enclosing the patio after the fact without proper approvals/permits will result in enforcement against Jing. Subject: PlanCheck Page Label: [1] COVER Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Revise to be 2021 IBC and 2021 editions of all other I codes (2020 NEC is correct) A1.2 and A5.1 show roof drainage sloping to gutters in the middle/back half of the roof, this shows a gutter on the front of patio roof and all drainage sloping to it. Coordinate plans and confirm what the actual proposed drainage will be. IDEWALK TREE GRATE URE NEERING ELECTRIC HEATING UNIT ABOVE ROOF O ABOVE *ALL WI LINE BO 12" ABO *NO PER FLA *INT & D EXISTING DRAIN TO BE USED AS NEEDED FROM ROOF DRAINAGE *ROUTED UNDER FLOORING 8"x TIM 22'-03 8" 6'-8"6'-8"6'-8" SP A N D I R E C T AC PROPOSED 20"SQ X 12" CONC FTG 2 S2.3 C Heaters to be provided with occupant sensor or timer switch so that system is automatically de-energized when occupants are not present. Controls shall be configured to allow the system to operate for four hours max per day (Aspen IECC C403.13.1). Please note this on the plan. 37'-0" ROOF FRAMING & FOUNDATION PLAN 1/2" = 1'-0" 1 S1.0 ROOF FRAMING & FOUNDATION PLAN SCALE: 1/2"=1'-0" S1.0N FOR CONSTRUCTION OWNER : PHASE : JING TITLE : Your S sheets are marked not for construction. The sheets stamped by your engineer still make reference to the removable wall panels that will not be approved. Your engineer will need to stamp sheets that outline framing req's and make no reference to removable wall panels. SIMPSON LUS210 FMH SLOPING TPO ROOF 1/4"=1'TOWARDS SCUPPER* GUTTER/DOWNSPOUTSTBDPARAPET BUILD UPW/FLASHING CAP 4" GUTTER DETAIL/TYPTBD WOOD SOFFIT TBD 6X10 DF#2 TIMBER BM W/(2) 5/8"DIAx __ MACH BOLTS &WASHER @EA POST, STAGGER SPACE EXISTING 9.5 LVLLEDGER *VRFYSTRUCTURAL DETAILS 2X10 LATERAL BLK'G PL 8" HT COLUMNS DF#2TREATED STAINEDBLACK TO MATCH TRIM 6" REV E A L 1 1/4" EXISTING SLAB EXIST BLDG SUBSTRATE,2X__ WOOD FRAME WALLTO BE VERIFIED BY GC TOE.O.R EXIST FLR FRAMING RIMBD. TBV BY GC TO E.O.R. 2X10 @ 16"OC DF#2 ROOFJOISTS W/ SIMPSONLUS210 FACE MOUNT HGR EXISTING CEILINGHGT TO BE VFD BY ARCHITECTOF RECORD EXISTING FINISH FLR ADD LEDGER PLATES &STR FASTENERS AS REQ'DBY E.O.R. A 10" SQ CONC. PEDESTAL W/ (4) NO.4 PREBENT VERT DOWELS W/10" BEND AT AT BOTTOM TIED TO BOTTOM STEEL REBAR.SIMPSON CB88 COLUMN BASE OR ALT CBSQ88-SDS2 OR ALT CPS7STANDOFF BASE B 20" SQ X 10" THK, 4000PSI @ 28 DAYS CONC PAD FTG W/ (3) #5,GR 60 REBAR EA. WAY 10" 1'-8" 2"8" A B 6" REMOVABLE PANELS6.5" SIP PANELS ATTACHED TO2X4DF#2 FRAMING WALLSEGMENTS W/ OPER. WINDOWS) PL STRUCTURAL NOTES: SIMPSON POST BASE (3) ALTS. SEENOTEA 3 3/8" 10" 10" 10" SQUARE CONCPEDESTAL 3'-0 " ASSUMEDGRAVEL/COBBLESUBGRADE TBV BY GCE.O.R 4 1/2" A 8X8 TREATED TIMBER POST LEGEND: B 1/2" DRYWALL C 6 1/2" THICK SIP PANEL R=25 W/ 7/16"OSB & EPS CORE D 48" X 50" SLIDER WINDOWS (2) PANELS E (3) METAL LOOP GRAB HANDLES EA. END REMOVABLE PANELS A 1'-0"4'-0" 6'-0" 1'-0" B ED 6'-8" C 3S2.3 3S2.3 4" GUTTER 2X6 TOP PL LET INTO SIPPANEL W/ CONST GRADEGLUE 6X10 TIMBER BM LET INTO8X8 POST PL 1/2" DRYWALL PL 1'-4 " 4'-2 " 3'-7 " 6 1/2" SIP PANEL, R-21 @ 75°F 8X8 POST BEYOND 48"W X 50"H SLIDER WINDOW (2PANELS @ 24" X 50") 2X6 PL LET INTO SIP PANELW/ CONST GRADE GLUE 2X6 SILL PL LET INTOSIP PANEL W/ CONSTGRADE GLUE 4"7 1/2"ROOF COV'G 2X10 @ 16" O/C EXISTING FINISH FLR 9'-1 " EXTERIOR DETAILS SCALE: 1"=1'-0" S2.3 ROOF/ COLUMN SECTION 1" = 1'-0" 2 S2.3 FORCONSTRUCTION OWNER : PHASE : PROJECT No. : EN G I N E E R O F R E C O R D CA L V E T T I E N G I N E E R I N G INC . P O B O X 4 2 3 1 ASP E N , C O 8 1 6 1 1 (C) 2 3 9 . 4 6 4 . 0 6 2 4 AL C E N G R G @ A O L . C O M DATE : SEAL: JIN G A S P E N 41 3 E . M A I N S T AS P E N , C O 8 1 6 1 1 JING 2217 AUGUST 1, 2022 TITLE : HPC REVIEW: NOV 16, 2022 PLAN SECTION 1" = 1'-0" 1 S2.3 REMOVABLE WALL SECTION 1" = 1'-0" 3 S2.3 Removable panels are not a part of yourHP and planning approvals. Removereferences to removable wall panels orenclosing of the patio in any way. Acknowledge that the applicantunderstands that no walls or enclosuresother than the roof are approved,installation of any walls or enclosing thepatio after the fact without properapprovals/permits will result in enforcementagainst Jing. CEILING HEIGHT A.F.F.+13'-11" PROJECT ADDRESS: PARCEL ID: FIRE SPRINKLER SYSTEM INSTALLED: no APPLICABLE CODES: ·2015 IRC (International Residential Code) Chapters 1-10 ·2015 IRC appendixes: ·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission. ·2015 IPC (International Plumbing Code) ·2015 IMC (International Mechanical Code) ·2015 IFGC (International Fuel Gas Code) ·2015 IECC (International Energy Conservation Code) - Prescriptive Path ·2015 IFC (International Fire Code) ·2020 NEC (National Electrical Code) 413 e main street - aspen, co 81611 cc - commercial core n/a mixed use n/a ZONING: F.A.R. PERMITTED USE: SETBACKS: Return Air Recessed Radius Riser Reference Reflected Refrigerator REC. RAD. R.A. R. REFR. REFL. REF. Overlay Mechanical Membrane Minimum Metal Medicine Cabinet Medium Density Manufacturer M.D.O. MEMB. MECH. M.C. MIN. MTL. MFR. Gypsum Handicapped Hose Bibb Hollow Core or Header Head Hardboard H.B. H.C. GYP. HDR. HDBD. HD. . . ST. UIP. U.Forced Air Unit Fire Alarm Equipment Existing Expansion Exterior ols HOSE BIBB REVISION COLOR FINISH MATERIALXX X JUNCTION BOX project statistics TYPE: OCCUPANCY : OVERALL PROJECT HEIGHT AND AREA: iv - ht a-2 n/a # 273707330002 Revise to be 2021 IBC and 2021 editions of all other I codes (2020 NEC is correct) The structural pages have been updated, notating that all drainage direction and slopes should refer to the architectural plans and details. Drainage will go towards the sides, not the front. *However - our square box gutter will continue all the way around to keep the fascia profile consistent throughout - A2.1 / A5.1 Timed / Sensor controls located and Aspen IECC comment noted. A1.1 / A1.3 / A4.1 Sheets are marked "For Construction" as reviewed by Justin H. Sheets have been updated to cross out and note that all dwgs and details involving walls or temp walls are no longer included in this permit. S2.3 Sheets have been updated and re-stamped to cross out and note that all dwgs and details involving walls or temp walls are no longer included in this permit. There are no plans anymore for the temporary wall situation. S2.3 Updated G-01 07/27/2023 Subject: PlanCheck Page Label: [1] JING ELEVATIONS PROPOSED Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Show the fire department connection in elevation and plan view to demonstrate it will still be fully accessible after this alteration. Subject: PlanCheck Page Label: [1] JING SECTIONS PROP 1 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: 2 Layer of 5/8" gyp required on underside of roof construction for 1 hour roof assembly, revise detailing to show that or propose a different 1 hour rated assembly for the roof (required due to IIIA type of construction). Subject: PlanCheck Page Label: [1] JING SECTIONS PROP 1 Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: You show insulation in the roof assembly in your graphic. Clarify what is proposed and revise if that is not actually being proposed. Subject: PlanCheck Page Label: [1] JING SITE PLAN RCP Author: justinh File Name: 90.JingAspenArchPlans.20230511.pdf Color: Note that exterior lighting shall be provided with a photocell or timer switch that will automatically keep lights turned off during daylight hours per IECC C405.2.7.1. 15'-8" 9'- 7 14" 9' - 1 34" door an awning new slab flush en beyond th elevation Show the fire department connection in elevation and plan view to demonstrate it will still be fully accessible after this alteration. -8 " 9' - 2 " 10 ' - 1 0 34" ass 'a' roof assembly 2 Layer of 5/8" gyp required on underside of roof construction for 1 hour roof assembly, revise detailing to show that or propose a different 1 hour rated assembly for the roof (required due to IIIA type of construction). class 'a' roof assembly You show insulation in the roof assembly in your graphic. Clarify what is proposed and revise if that is not actually being proposed. flat roof with parapet*integrated drainage& downspouts to slopeto existing storm drain fl u s h 3% grade to patio downspout 4'-378" Note that exterior lighting shall be provided with a photocell or timer switch that will automatically keep lights turned off during daylight hours per IECC C405.2.7.1. Fire Dep. Connections have been shown accurately on floor plans and elevations Accessibility to remain throughout / afterwards has been noted on relevant sheets A1.1 / A2.1 Building Section has been updated to show 2 layers of GYP for 1 hr rating. A5.1 Interior Roof insulation has been removed from the section & permit set. A5.1 Exterior Lighting Switch shown on RCP noting a timer and lights to be off during daylight hours. A4.1 07/27/2023