HomeMy WebLinkAboutFile Documents.155 Miners Trail Rd.0097-2021-BRES (13)Generated by REScheck-Web Software Compliance Certificate Project 155 Miners Trail Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:Alteration Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 155 Miners Trail Rd Aspen, CO 81611 Owner/Agent: RAF PT Aspen LLC 10000 Memorial Dr #320 Houston, TX 77023 Designer/Contractor: Alison Agley Ali & Shea LLC PO Box 6564 Snowmass Village, CO 81615 970.274.9796 aliagley@gmail.com Permit Number: Compliance: Passes using prescriptive requirements for alteration projects Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Ceiling Master Deck: Flat Ceiling or Scissor Truss 62 49.0 0.0 0.026 0.026 2 2 Ceilings Exposed: Flat Ceiling or Scissor Truss Exemption: Framing cavity filled with insulation --------------------- Flat Ceilings: Flat Ceiling or Scissor Truss Exemption: Framing cavity not exposed.--------------------- Vaulted Ceilings: Flat Ceiling or Scissor Truss Exemption: Neither sheathing nor insulation is exposed. --------------------- Skylight: Wood Frame 6 0.470 0.550 3 4 Sloped Cathedral Ceiling: Cathedral Ceiling Exemption: Neither sheathing nor insulation is exposed. --------------------- Skylight: Wood Frame 6 0.470 0.550 3 4 East Wall: Wood Frame, 16" o.c. Exemption: Framing cavity filled with insulation --------------------- E- *** Door Garages: Solid Door (under 50% glazing)144 0.320 0.320 46 46 E- *** Door Garages Copy: Solid Door (under 50% glazing)144 0.320 0.320 46 46 E- Door 110: Glass Door (over 50% glazing)24 0.320 0.320 8 8 Project Title: 155 Miners Trail Data filename:Page 1 of 11 10/12/21Report date:11/03/2021 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA E- *** Door 108 FRONT: Glass Door (over 50% glazing)57 0.320 0.320 18 18 E- Window 107 sides: Wood Frame 8 0.260 0.320 2 2 E- Window 107 Picture: Wood Frame 20 0.240 0.320 5 6 E- Window 109: Wood Frame 15 0.260 0.320 4 5 E- Window 204 sides: Wood Frame 14 0.260 0.320 4 4 E- Window 205 Sides: Wood Frame 10 0.260 0.320 3 3 E- Window 205: Wood Frame 8 0.240 0.320 2 3 E- Window 206: Wood Frame 12 0.260 0.320 3 4 E- Window 204: Wood Frame 16 0.240 0.320 4 5 E- Window 011: Wood Frame 20 0.260 0.320 5 6 West Wall: Wood Frame, 16" o.c. Exemption: Framing cavity filled with insulation --------------------- W- Door 003: Glass Door (over 50% glazing)43 0.270 0.320 12 14 W- Door 101: Glass Door (over 50% glazing)64 0.300 0.320 19 20 W- DoorS 102 A+B: Glass Door (over 50% glazing)99 0.320 0.320 32 32 W- Window 001: Wood Frame 10 0.260 0.320 3 3 W- Window 002 Sides - w: Wood Frame 16 0.260 0.320 4 5 W- Window 002: Wood Frame 16 0.240 0.320 4 5 W- Window 100: Wood Frame 18 0.240 0.320 4 6 W- Window100 SIDES: Wood Frame 24 0.260 0.320 6 8 W- Window 102 C+D: Wood Frame 19 0.240 0.320 5 6 South Wall: Wood Frame, 16" o.c. Exemption: Framing cavity filled with insulation --------------------- S- Door 201: Glass Door (over 50% glazing)19 0.320 0.320 6 6 S- Window 102 A+B: Wood Frame 60 0.260 0.320 16 19 S- Window 105: Wood Frame 12 0.260 0.320 3 4 S- Window 107: Wood Frame 12 0.260 0.320 3 4 S- Window 005: Wood Frame 45 0.260 0.320 12 14 S- Window 009: Wood Frame 38 0.260 0.320 10 12 S- Window 204B: Wood Frame 15 0.260 0.320 4 5 S- Window 201A: Wood Frame 33 0.240 0.320 8 11 S- Window 201 B: Wood Frame 17 0.240 0.320 4 5 S- Window 204C: Wood Frame 10 0.260 0.320 3 3 North Wall: Wood Frame, 16" o.c. Exemption: Framing cavity filled with insulation --------------------- N- Window 100b: Vinyl Frame 16 0.260 0.320 4 5 Basement: Solid Concrete or Masonry Wall height: 0.0' Depth below grade: 0.0' Insulation depth: 0.0' Exemption: Framing cavity filled with insulation --------------------- Project Title: 155 Miners Trail Data filename:Page 2 of 11 10/12/21Report date:11/03/2021 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Basement 1: Wood Frame Wall height: 0.0' Depth below grade: 0.0' Insulation depth: 0.0' Exemption: Framing cavity not exposed. --------------------- Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: 155 Miners Trail Data filename:Page 3 of 11 10/12/21Report date:11/03/2021 Inspection Checklist Requirements: 36.0% were addressed directly in the REScheck software REScheck Software Version : REScheck-Web Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Noted, Existing conditions to remain, finish alteration only 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 4 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Noted, Existing conditions to remain, Interior remodeling only 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Existing conditions will be reviewed and repaired if damaged or missing 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 5 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Window Manuf. Specs included 402.1.1, 402.3.3, 402.3.6, 402.5 [FR5]1 Skylight U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Existing conditions will be reviewed where possible and repaired if damaged or missing 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 6 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 7 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Noted, Existing conditions to remain, finish alteration only Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 8 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Details on sheet A8.1 for new ceiling insulation at master deck 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Existing conditions will be reviewed where possible and repaired if damaged or missing 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Existing conditions will be reviewed where possible and repaired if damaged or missing 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.4 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.3 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 9 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 10 of 11 10/12/21Report date:11/03/2021 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.10.2 [FI12]3 Readily accessible switch on heaters for swimming pools or permanent in-ground spas. Switch operation does not change heater thermostat setting. Heater circuit breaker is installed independent of switch. Gas-fired heaters equipped with ignition pilots that are not continuously burning pilots. Complies Does Not Not Observable Not Applicable 403.10.3 [FI19]3 Timer switches or other automatic preset schedule control method are installed on heaters and pumps serving pools and permanent Complies Does Not Not Observable Not Applicable 403.10.4 [FI20]3 Outdoor heated pools and outdoor permanent spas have a vapor retardant cover. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 155 Miners Trail Data filename:Page 11 of 11 10/12/21Report date:11/03/2021 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 0.00Above-Grade Wall 0.00Below-Grade Wall 0.00Floor 49.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.26Window 0.32Door 0.47Skylight Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments 11/03/2021