HomeMy WebLinkAboutFile Documents.155 Miners Trail Rd.0068-2022-BCHO (6)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. bobn 10/24/2022ZONING REVIEWED BY ZONING 10/24/2022 bobn It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Land Use Code requirements. The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 0097-2021-BRES Blissful LLC 155 Miners Trail 273707323002 APPLICATION ACCEPTED DATE: 2022-09-12 PERMIT NUMBER: 0068-2022-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 155 MINERS TRL RD UNIT: PARCEL ID: 273707323002 LEGAL DESCRIPTION: MOCKLIN OWNER: BLISSFUL LLC PERMIT CONTRACTOR: IA SEDGWICK INC DESCRIPTION OF WORK Revised lower patio footprint to fit in building envelope. Added steel stair off south side of deck. Added stairs from front entry porch to garage exterior. Further details on REMP locations and calcs. New stone bench on lower patio. Removed center column of garage (see additional structural submitted 07- 15 to original permit 0097-2021-BRES. Additional skylight shown on roof. Removed column at M Bedroom 201 between door and windows. Minor exterior material changes to north side of garage. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? No CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE (IRC) One family REQUIRED SPECIAL INSPECTIONS High-Strength Bolting;Structural Steel Welding CONSTRUCTION TYPE ENERGY CODE COMPLIANCE RESCheck UA Alternative OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. 37 OTHER CODE EDITIONS 2015 IEBC, 2020 NEC TOTAL SNOWMELT SQ.FT. 1,081 HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? SEE NOTES #1 PLANS 1 SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ 0097-2021-BRES 1/6/22 1081 SF 37 SF (exempt) A3.1-A3.3 0 75% Jim Pomeroy General Electrical Requirements Any areas affected by the renovation must be brought up to the current electrical code including: tamperproof receptacles (NEC 406.12), ground-fault circuit interrupter protection (NEC 210.8), arc-fault protection (NEC 210.12), receptacle spacing (NEC 210.52) etc. 01/06/2023 jimp