Loading...
HomeMy WebLinkAboutFile Documents.1215 Snowbunny Ln.0072-2022-BCHO (4)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. Project: 1215 Snowbunny Ln, Unit B Permit # 0063-2022-BRES 22 September 2022 Change Order 01 – Summary Change order 01 is a structural clarification to replace insufficient existing roof framing. The existing interior volume remains unchanged. Ceilings heights are not impacted, and the overall area remains the same. New parallel chord trusses will replace existing dimensional lumber roof framing. The height of the building will increase approximately 12”-18” as a result. Final heights will be determined through the design-build-engineering process by the roof truss manufacturer. We are submitting the worst case (18”) scenario should we need a 24” tall truss. Included with the change order submittal are the following drawings: 1. Structural engineering drawings 2. Calculations for both height and demolition area 3. Architectural elevations showing the height increase Bryan May, AIA Bryan May Architecture + Interiors 09/26/2022 May 2, 2022 Bryan May Architecture 501 Rio Grande Pl Suite 109 Aspen, CO 81611 Attn: Bryan May RE:Structural Remodel 1215 Snowbunny Lane Unit B, Aspen, CO 8161 Bryan, We have reviewed the Schematic Pricing Drawings for the remodel at 1215 Snowbunny Lane, Unit B provided by your office, dated February 18, 2022. The drawings show a single family residence, approximately 2,700 square feet in size with an attached garage and a finished basement. We understand that as a part of the remodel, many of the interior walls will be reconfigured and/or removed. Prior to removal or demolition of any interior walls or framing members, internal wall and ceiling finishes shall be partially removed to allow observation of the structural system. Once the structure is visible, we shall be contacted to perform a structural observation of the exposed structure in order to determine the structural implications of the proposed modifications. Demolition or removal of any framing members shall not proceed until this visit is completed. If structural reinforcement, strengthening, or modifications are necessary, we can provide sealed structural plans and details as required. We appreciate the opportunity to work with you and your team again. If you have further questions or concerns, please feel free to reach out. We look forward to the project. Sincerely, Tim Strickland, P.E. Principal 2225 E. MURRAY HOLLADAY RD., SUITE 110 ::SALT LAKE CITY, UTAH 84117 ::801.274.3950 ::structuralds.com May 2, 2022 09/22/2022 10/18/2022 justinh SEE NOTES #1 PLANS APPLICATION ACCEPTED DATE: 2022-09-26 PERMIT NUMBER: 0072-2022-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 1215 SNOWBUNNY LN B UNIT: PARCEL ID: 273512236002 LEGAL DESCRIPTION: COTTONTAIL TOWNHOUSES OWNER: LINDEN LANE LLC PERMIT CONTRACTOR: GF WOODS CONSTRUCTION INC DESCRIPTION OF WORK Structural clarification. Structural drawings and associated architectural drawings to replace existing roof framing with new trusses. No change to floor area. USE OF BUILDING Multi -Fa mily FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D BUILDING TYPE (IRC) Two family REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE OCCUPANCY GROUP (IBC) R -3 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? No 0072-2022-BCHO Linden Lane LLC 1215 Snowbunny Ln B 273512236002