Loading...
HomeMy WebLinkAboutInspection.204 S Galena St.0030-2022-BCOM (6)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 1-1 7 02/21/23 2 / 5 4.00 12.57 77,182 6,140 5 N 1-2 28 03/14/23 2 / 26 4.00 12.57 97,066 7,720 3 C4 N 1-3 28 03/14/23 2 / 26 4.00 12.57 98,520 7,840 3 C4 N 1-4 28 03/14/23 2 / 26 4.00 12.57 96,202 7,650 3 C4 N 1-5 28 03/14/23 2 / 26 Test Age Average Strengths (psi): 7 Day - 6140, 28 Day - 7740 C4: Strength is greater than or equal to f'c. Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5) Checked In : 02/16/2023 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:1 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:158 / 180158 Contractor: Technician:Barto, Matthew Cast By:Barto, Matthew Date Cast:02/14/23 Sampled From:Chute Placement Method:Chute Sample Details Batched:07:57 MST Sampled:09:30 MST Cast:09:40 MST Truck Empty:09:55 MST Placement Time:118 (min) Placement Location:Topping Slab Location Details:North storefront Sample Location / Notes:@20/40 yard Batch Log Strength:4000 (psi) Specifications Supplier:Casey Concrete On-Site Admixtures: None Location Standard Cure Field Cure Field Measurements Plastic Unit Weight:143.0 (lb/ft³) Air Content:2.6 Load Volume:10.00 (yd³) Weather:Slump (in):5-3/4 Air Temperature (F):Concrete Temp (F):68 Lab Test Results Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601 General Remarks Notified contractor of physical property results. Reviewed by RB. Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Sachse Construction Detroit, MI 48201 3663 Woodward Avenue Suite 500 Project: Gucci Aspen GS06753.000F-365 Aspen, CO 204 S Galena Street Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 111309 02/14/2023 Report #: CC-000001 Glenwood Springs 234 Center Drive Glenwood Springs, CO 81601 Phone: 970-945-2809 Report Date: 03/15/2023