Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1265 Red Butte Dr.0113-2022-BRES (10)
M-SERIES Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SPECIFICATIONS Cooling Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . .17,200 Btu/h Heating Capacity at 47°F* . . . . . . . . . . . . . . . . . . . . .21,600 Btu/h Electrical RequirementsPower Supply . . . . . . . . . . . . . . . . . . . .208 / 230V, 1-Phase, 60 HzMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 A VoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . .AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . .DC ±24V Blower Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 .74 F .L .A . Airflow (Lo - Med - Hi) Cooling . . . . . . . . . . . . . . . . . . . . . . . . . .423 - 529 - 635 Dry CFM381 - 476 - 572 Wet CFM Heating . . . . . . . . . . . . . . . . . . . . . . . . . .423 - 529 - 635 Dry CFM Sound Pressure Level (Lo - Med - Hi) Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 - 34 - 38 dB(A) Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 - 34 - 38 dB(A) DIMENSIONS UNIT INCHES / MM W 46-7/8 / 1,190 D 27-9/16 / 700 H 7-7/8 / 200 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 lbs . / 28 kg External Finish . . . . . . . . . . . . . . . . . . . . . .Galvanized-steel SheetsField Drainpipe Size O .D . . . . . . . . . . . . . . . . . . . . . . .1-1/4" / 32 mm Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R410ARefrigerant Pipe Size O .D . Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/2" / 12 .7 mm Liquid Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4" / 6 .35 mmConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flared SUBMITTAL DATA: SEZ-KD18NA4** 18,000 BTU/H HORIZONTAL-DUCTED INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS Indoor Unit: SEZ-KD18NA4** GENERAL FEATURES • Horizontal-ducted indoor unit for concealed applications • Ultra thin body: 7-7/8" high • Built-in drain mechanism for condensate removal; lifts to 21-11/16" • Air filter is included with indoor unit • Quiet operation ― as low as 23 dBA • Indoor unit powered from outdoor unit using A-Control • AUTO fan speed control • Automatic restart following a power outage • Limited warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit □Filter Box with MERV 8 Filters (FBL1-3) □Bottom Return Plate (BRP-3) Outdoor Unit □Drain Socket (MAC-811DS) □Drain Pan Heater (MAC-641BH-U) □Three-pole Disconnect Switch (TAZ-MS303) □Air Outlet Guide (MAC-856SG) □Mounting Base (DSD-400N) □Mounting Pad (ULTRILITE1) □Wall-mounting Brackets (CWMB1) Controller Options □Wireless Wall-mounted Remote Controller Kit (MHK1)* □Portable Central Controller (MCCH1)* □Outdoor Air Sensor (MOS1)* □Wired Wall-mounted Controller (PAR-31MAA)* □Simple MA Remote Controller (PAC-YT53CRAU)* *See Submittal for information on each option . □Remote Temperature Sensor (M21-JKO-307) □Hand-held Wireless Remote Controller (PAR-FL32MA; eq.PAR-FA32MA-E) □Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA) □Lockdown Bracket for Hand-held Controller (RCMKP1CB) * Rating Conditions per AHRI Standard Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ Technical and Service Manual.) **APPLIES TO INDOOR UNIT: □SEZ-KD18NA4 □SEZ-KD18NA4 .TH □SEZ-KD18NAR1 .TH □SEZ-KD18NA4R1 .TH Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. SEZ-KD18NA4** INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW CHARTS SEZ-KD18NA4 (External static pressure 0.06[in.WG](15Pa)) 208/230V 60Hz 910111213141516171819 0 10 20 30 40 50 Ex t e r n a l s t a t i c p r e s s u r e [ i n . W G ] ( P a ) [0.20] [0.16] [0.12] [0.08] [0.04] [318][353][388][424][494][459][530][565][600][671][636] Middle Low High Limit Rated point Airflow rate(m3/min)[CFM] SEZ-KD18NA4 (External static pressure 0.02[in.WG](5Pa)) 208/230V 60Hz Airflow rate(m3/min)[CFM] 910111213141516171819 0 40 30 20 10 Ex t e r n a l s t a t i c p r e s s u r e [ i n . W G ] ( P a ) [0.16] [0.12] [0.08] [0.04] [318][353][388][424][494][459][530][565][600][671][636] Middle Low High Limit Rated point SEZ-KD18NA4 (External static pressure 0.20[in.WG](50Pa)) 208/230V 60Hz 910111213141516171819 0 10 20 30 40 60 70 50 80 Ex t e r n a l s t a t i c p r e s s u r e [ i n . W G ] ( P a ) [0.32] [0.28] [0.24] [0.20] [0.16] [0.12] [0.08] [0.04] [318][353][388][424][494][459][530][565][600][671][636] Middle Limit Rated point Low High Airflow rate(m3/min)[CFM] SEZ-KD18NA4 (External static pressure 0.14[in.WG](35Pa)) 208/230V 60Hz 910111213141516171819 0 10 20 30 40 60 70 50 80 Ex t e r n a l s t a t i c p r e s s u r e [ i n . W G ] ( P a ) [0.32] [0.28] [0.24] [0.20] [0.16] [0.12] [0.08] [0.04] [318][353][388][424][494][459][530][565][600][671][636] Airflow rate(m3/min)[CFM] Middle Limit Rated point Low High 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. FORM# SEZ-KD18NA4** FOR MULTI-ZONE SYSTEMS - 201411 DIMENSIONS: SEZ-KD18NA4** Unit :mm(in.) (46-7/8)1190 (39)990 (31-1/8)790 N (48-25/32)1239 (40-29/32)1039 (33-1/16)839 M Drain pipe(O.D.ø 32(1-1/4)) Terminal block (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) 2 Refrigerant piping are connection (liquid) ø12.7(1/2) mm(in.) (35-7/16) (27-9/16) (19-11/16) (41-3/4) (33-7/8) (26) (47-1/4) (39-3/8) (31-1/2) (39-3/8) (31-1/2) (23-5/8) (41-3/4) (33-7/8) (26) (47-3/16) (39-5/16) (31-7/16) (45-3/8) (37-1/2) (29-5/8) (43-5/16) (35-7/16) (27-9/16)700 Drain pipe(O.D.ø32(1-1/4)) (Emergency draining) ø 6.35(1/4) ø9.52(3/8) SEZ-KD15NA4** 900 952 998 860 9 800 1000 860 7 700 20 24 16 L 900 500 K 9 5 J 1060 660 H 8006007660798752 Knockout hole ø 27(1-3/32) (Remote controller transmission line) Knockout hole ø 27(1-3/32) (Indoor/outdoor connecting line) G 1200 F 1000 E 11 D 1060 C 1100 B 1152 SEZ-KD09NA4** SEZ-KD12NA4** SEZ-KD18NA4** ModelA 1198 Gas pipe Liquid pipe L-ø 2.9(1/8) 2X2-ø2.9(1/8) 2XE-ø 2.9(1/8) Control box Air lter Suspension bolt hole 4-14X30(9/16X1-3/16) Slot Refrigerant piping are connection (gas) 1 1 2 Drain pipe(O.D.ø32(1-1/4)) (Spontaneous draining) AirinletAiroutlet N M 175 ±5(6-29/32 ±7/32) Less than 300 Le s s t h a n 5 5 0 (11-13/16) (2 1 - 2 1 / 3 2 ) Mo r e t h a n 2 0 Mo r e t h a n 1 0 57 (2 - 1 / 4 ) 57 (2 - 1 / 4 ) (1-3 1 / 3 2 ~ 5 - 2 9 / 3 2 ) (30-1 9 / 3 2 ) (17- 2 3 / 3 2 ) (11-1 3 / 1 6 ) (17-2 3 / 3 2 ) More t h a n 3 0 0 (1 3 / 1 6 ) (1 3 / 3 2 ) (3 - 9 / 1 6 ) (5 - 2 9 / 3 2 ) (2-25/32)(4-19/32) 70 10(13/32) (3 - 1 5 / 1 6 ) (1-15/16)(24-5/8) 45 0 37(1-15/32) 20 0 ( 7 - 7 / 8 ) H 157.5 (6-7/32)20(13/16) 100(3-15/16) 37(1-15/32) 12(1/2) 12 (1 / 2 ) 88 (3 - 1 5 / 3 2 ) 10 0 ( 3 - 1 5 / 1 6 ) X J = K 10 0 (3 - 1 5 / 1 6 ) 88 (3 - 1 5 / 3 2 ) 77 7 50 (1-31 / 3 2 ) 50 ~ 1 5 0 50(1 - 3 1 / 3 2 )G 450 10(13/32) 49 25 (1 ) 17 0 (6 - 2 3 / 3 2 ) 10 2 (4 - 1 / 3 2 ) 116 10 0 25 (1 ) 23(29/32) C B ( S u s p e n s i o n b o l t p i t c h ) 23 (2 9 / 3 2 ) A 90 D ( D u c t ) 10 0 ( 3 - 1 5 / 1 6 ) X ( E - 1 ) = F 10 0 (3 - 1 5 / 1 6 ) 15(19/32) Drain hose (I.D.ø32(1-1/4)) <accessory> (Actual length) Note2 Access door Required space for service and maintenance Access doorCeiling surface Make the access door at the appointed position properly for service maintenance. Note1.Use M10 screw for the suspension bolt (eld supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA4** model,which has 3 fans. SEZ-KD09,12NA4** models have 2 fans. SEZ-KD18NA4** models have 4 fans. 4.In case an inlet duct is used,remove the air lter(supply with the unit), then install the lter(eld supply) at suction side. 15 9 ( 6 - 9 / 3 2 ) 345(13-19/32) 20 ( 1 3 / 1 6 ) 30 ( 1 - 3 / 1 6 ) 23 ( 2 9 / 3 2 ) 270(10-21/32) 20 ( 1 3 / 1 6 ) 625(Suspension bolt pitch) 700(27-9/16) 677(26-21/32) 15 0 ( D u c t ) APPLICATIONS Electro Industries’ Packaged Make-Up Air units are designed for today’s tighter homes where unhealthy negative pressure can be created by appliances such as kitchen vent hoods, fi replaces, dryers, gas furnaces, water heaters, bathroom exhaust fans or any appliance without sealed combustion. These high effi ciency units provide fresh air to keep the home or building at positive pressure, reducing backdrafting combustion gasses that could create a health risk. International Residential Code (IRC) requires exhaust hood systems of 400 CFM and greater to have make-up air equal to the exhaust air and to automatically open and close with the operation of the fan. STANDARD FEATURES ▪ WarmFlo® Digital Proportional Temperature Control - utilizes full element modulation with solid state relay, inlet and outlet temperature sensors, to maintain precise user defi ned temperature set point ▪ Integrated powered inlet damper ▪ Aluminum mesh permanent washable fi lter ▪ All models include (1) CT “doughnut” ▪ Simple installation, mounting kit included ▪ Listed for horizontal or vertical installation ▪ Can be easily wall-hung ▪ 20-year fi nned rod element warranty ▪ 2-year parts warranty ▪ Made in the USA ELECTRO’S INDUSTRY EXCLUSIVE FEATURES OF 5-22 KW MODELS *Electro’s unique control adapts to multi-speed range hoods or multiple fan applications: ▪ Multiple Fan Speed Output - Low, Medium, and High fan speed output to match multi-speed range hoods. ▪ Multiple Control Input Options - Three current transformer (CT) inputs allow for multiple fan applications. CT inputs will also provide variable blower speeds to more closely match multi-speed exhaust fans. Activation can also be as simple as an end switch or contact closure. ▪ LCD Display - Interactive display used for multiple fan speed calibration and real time estimated CFM output. Also displays desired target temperature as well as incoming and supply air temperatures. ELECTRO’S FEATURES OF 1-2 KW MODELS ▪ Variable Fan Speed Output - Easy to adjust fan speed knob allows for precise CFM output. ▪ 120VAC Power Connection - Plug-in cord allows for simple power connection. ▪ Control Input Options - Activated through a basic end switch connection, thermostat, or current sensing relay. SPECIFICATIONS (Reference Installation & Operating Instructions, EI906/EI907) Model kW Btu/h Amps Inter- nal CB Motor FLA Motor HP Phase Voltage CFM Max Fuse/ HACR Duct Connection Shipping WeightMax Static EM-MA01-120-1-06 1 3,410 8.3 N/A 0.5 1/16 1-50/60 120 150 0.03” 15 6” 31 EM-MA02-120-1-06 1.6 5,460 13.3 N/A 0.5 1/16 1-50/60 120 150 0.03” 20 6” 32 EM-MA05-240-1-08 5 17,070 20.8 N/A 0.4 1/10 1-50/60 240 350 0.03” 30 8” 59 EM-MA10-240-1-10 10 34,150 41.6 N/A 0.8 1/5 1-50/60 240 625 0.03” 60 10” 65 EM-MA15-240-1-14 15 51,220 62.4 60 + 30 1.7 1/3 1-50/60 240 1050 0.25” 90 14” 115 EM-MA20-240-1-14 20 68,300 83.2 60 + 60 2.5 1/2 1-50/60 240 1200 0.25” 120 14” 120 EM-MA14-208-3-14 14.4 49,170 40.0 50 1.7 1/3 3-50/60 208 900 0.25” 50 14” 115 EM-MA22-208-3-14 21.6 73,760 60.0 50 + 30 2.5 1/2 3-50/60 208 1250 0.25” 80 14” 125 PACKAGEDMAKE-UP AIR Electro Industries introduces the next generation of with unique multi-speed control* 05/07/2015 EL911Specifi cations subject to change without notice, all rights reserved. TO LOCATE A CONTRACTOR OR DISTRIBUTOR IN YOUR AREA VISIT WWW.ELECTROMN.COM AND CLICK ON DEALER FINDER TEMPERATURE RISE - Selecting the best model for your application: 1 Choose your desired temperature rise (this is the difference between the coldest design day temperature and desired duct air temperature). 2 Move across the chart from your desired temperature rise to the CFM required (you may have to select a model with a higher CFM and adjust down to your required CFM at installation). Example:In an application where your coldest day averages 0° F and you require 50° F duct air, choose 50° F temperature rise. If you require 400 CFM you would select the MA10. SINGLE PHASE MODELS 3-PHASE MODELS Model MA01 MA02 MA05 MA10 MA15 MA20 MA14 MA22 CFM CFM CFM CFM CFM CFM CFM CFM Re q u i r e d T e m p R i s e 80° F 39 71 197 395 604 790 553 869 70° F 45 81 225 451 677 903 632 993 60° F 53 95 260 526 790 1053 737 1160 50° F 63 114 316 632 948 1264 885 N/A 40° F 79 158 N/A N/A 1185 N/A N/A N/A 30° F 105 168 N/A N/A N/A N/A N/A N/A DIMENSIONS* *Dimensional drawings shown in side view. 29 3/8" 10 1/2" 6" MALE DUCT 6" MALE DUCT 12 5/8" 1kW-2kW 39 13/16" 13 1/2" 8" MALE DUCT 8" MALE DUCT 14 3/8" 5kW 10kW 14 3/8" 10" MALE DUCT 10" MALE DUCT 39 13/16" 13 1/2" 14kW-22kW 22 3/8" 14" MALE DUCT14" MALE DUCT 46 9/16" 19 1/2" INSTALLATION SPECIFICATIONS This product is designed for zero clearance, but use the following mounting and spacing criteria: 1. Unit can be installed vertically or horizontally. When vertical, inlet must face down. 2. When using CT doughnut, use Class II low voltage wiring methods to connect CT to Make-Up Air unit. 3. Make mounting provisions for a 1” air space at the top. 4. The sides, any location, can be in direct contact with wood framing materials. 5. No materials shall be in contact with the cabinet housing which has a fl ame point less than wood, 300° F (150° C). 6. Product shall be installed in a conditioned space only. 7. Heating elements are locked out when entering air temperature is > 55° F (12.8° C). Monticello, Minnesota 800.922.4138 www.electromn.com Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit PEAD-A36AA7 Outdoor Unit SUZ-KA36NA2 INDOOR UNIT FEATURES • Unobtrusive ceiling-concealed design for short-run ductwork • Wide ranging external static pressure (0.14-0.60 in. WG) • Built-in condensate lift mechanism (up to 27-9/16”) • Auto fan speed mode • Optional FB Series filter boxes for easy access and service • Ideal for residential homes, retail shopping centers, larger classrooms, office complexes, conference rooms, ballrooms, fitness centers, and more • Multiple control options available: ○kumo cloud® smart device app for remote access ○Third-party interface options ○Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency PEAD-A36AA7 & SUZ-KA36NA236,000 BTU/H HORIZONTAL MID STATIC DUCTED36,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR UNIT Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: PEAD-A36AA7 & SUZ-KA36NA2 test Cooling at 95°F1 Maximum Capacity BTU/H 33,000 Rated Capacity BTU/H 33,000 Minimum Capacity BTU/H 14,000 Maximum Power Input W 3,510 Rated Power Input W 3,510 Moisture Removal Pints/h 4.8 Sensible Heat Factor 0.84 Power Factor %98.6/98.6 Heating at 47°F2 Maximum Capacity BTU/H 36,000 Rated Capacity BTU/H 33,400 Minimum Capacity BTU/H 14,750 Maximum Power Input W 3,200 Rated Power Input W 3,170 Power Factor %98.3/98.3 Heating at 17°F3 Maximum Capacity BTU/H 23,100 Rated Capacity BTU/H 23,000 Maximum Power Input W 2,830 Rated Power Input W 2,830 Efficiency SEER 16.0 EER1 9.4 HSPF [IV]11.6 COP at 47°F2 3.0 COP at 17°F at Maximum Capacity3 2.39 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR]kA 5 Recommended Fuse/Breaker Size (Oudoor)A 20 Recommended Wire Size [Indoor - Outdoor]AWG 14 Indoor Unit MCA A 3.3 Fan Motor Full Load Amperage A 2.64 Fan Motor Output W 244 Airflow Rate at Cooling, Dry CFM 847–1024–1201 Airflow Rate at Cooling, Wet CFM 762–922–1081 Airflow Rate at Heating, Dry CFM 847–1024–1201 Sound Pressure Level [Cooling]dB[A]33–38–42 Sound Pressure Level [Heating]dB[A]33–38–42 External Static Pressure in.WG 0.14–0.2–0.28–0.4–0.6 Drain Pipe Size In. [mm]1-1/4 [32] Condensate Lift Mechanism, Maximum Distance In. [mm]27-9/16 [700] Coating on Heat Exchanger — External Finish Color Galvanized Unit Dimensions W x D x H: In. [mm]55-1/8 x 28-7/8 x 9-7/8 [1400 x 732 x 250] Package Dimensions W x D x H: In. [mm]65 x 34-11/16 x 13-7/16 [1650 x 880 x 341] Unit Weight Lbs. [kg]86 [39] Package Weight Lbs. [kg]101 [46] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]*°F 95 DB, 71 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum]°F 80 DB / 70 DB NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: PEAD-A36AA7 & SUZ-KA36NA2 test Outdoor Unit MCA A 17.0 MOCP A 31 Fan Motor Full Load Amperage A 1 Fan Motor Output W 60 Airflow Rate CFM 2020/1930 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling1 dB(A)55 Sound Pressure Level, Heating2 dB(A)55 Compressor Type DC INVERTER-driven Twin Rotary Compressor Model SNB220FQGM1T Compressor Rated Load Amps A 13.0 Compressor Locked Rotor Amps A 16.0 Compressor Oil Type // Charge oz.FV50S // 15.6 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W x D x H: In. [mm]33-1/16 x 13 x 34-5/8 [840 x 330 x 880] Package Dimensions W x D x H: In. [mm]38-9/16 x 16-9/16 x 39 [980 x 420 x 990] Unit Weight Lbs. [kg]129 [59] Package Weight Lbs. [kg]145 [66] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]*°F 115 DB / 14 DB Cooling Thermal Lock-out / Re-start Temperatures**°F 1.0 / 5 Heating Thermal Lock-out / Re-start Temperatures**°F 10.0 / 14 Refrigerant Type R410A Charge Lbs, oz 4, 14.0 Chargeless Piping Length Ft. [m]25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m]0.538 [50] Piping Gas Pipe Size O.D. [Flared]In.[mm]5/8 [15.88] Liquid Pipe Size O.D. [Flared]In.[mm]3/8 [9.52] Maximum Piping Length Ft. [m]100 [30] Maximum Height Difference Ft. [m]100 [30] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: PEAD-A36AA7 Control Interface 3-Pin Connector PAC-715AD BACnet® and Modbus Interface PAC-UKPRC001-CN-1 CN24 Relay Kit CN24RELAY-KIT-CM3 Connector cable for remote display PAC-SA88HA-EP IT Extender PAC-WHS01IE-E kumo station® for kumo cloud® PAC-WHS01HC-E Lockdown bracket for remote controller RCMKP1CB Remote Operation Adapter‡ PAC-SF40RM-E Thermostat Interface PAC-US444CN-1 USNAP Adapter PAC-WHS01UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 Remote Sensor Flush Mount Temperature Sensor PAC-USSEN001-FM-1 Remote Temperature Sensor surface mount PAC-SE41TS-E Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1 Wired Remote Controller Airzone ZBS Wired Blueface Principal Controller White AZZBSBLUEFACECB Airzone ZBS Wired Lite Controller White AZZBSLITECB Airzone ZBS Wired Think Controller White AZZBSTHINKCB Airzone ZBS Wireless Lite Controller White AZZBSLITERB Airzone ZBS Wireless Think Controller White AZZBSTHINKRB Deluxe Wired MA Remote Controller† PAR-40MAAU Simple MA Remote Controller† PAC-YT53CRAU-J Touch MA Controller† PAR-CT01MAU-SB Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller MHK2 Wireless MA Receiver PAR-FA32MA-W Wireless MA Remote Controller PAR-FL32MA-E Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 Control Wire 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel CW2042S2-100 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel CW2042S2-500 Disconnect Switch (30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 (30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W Filter Box Filter Box with MERV 13 Filter FBM2-4-A Lineset 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-10 100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-100 15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-15 30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-30 50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-50 65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-65 NOTES: ‡PAC-SF40RM-E (Unable to use with wireless remote controller) Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT ACCESSORIES: SUZ-KA36NA2 Air Outlet Guide Air Outlet Guide MAC-886SG-E Control/Service Tool M- & P-Series Maintenance Tool Cable Set M21EC0397 USB/UART Conversion Cable (Required for all laptop connection) M21EC1397 Mini-Split Wire 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW144-50 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW164-50 Mounting Pad Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Optional Defrost Heater Base Heater MAC-642BH-U1 Stand 18” Single Fan Stand QSMS1801M 24” Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Outdoor Unit Stand — 12” High QSMS1201M Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 20 0 ( 7 - 7 / 8 ) 120° 120 °ø125 13 5 378(14-15/16)153(6-1/16) B( S u s p e n s i o n b o l t p i t c h ) 23 ( 1 5 / 1 6 ) CA 40 ( 1 - 5 / 8 ) 15(5/8) 40 ( 1 - 5 / 8 ) H± 3 ( H ± 1 / 8 ) J± 3 ( J ± 1 / 8 ) 58 ( 2 - 5 / 1 6 ) 20 ( 1 3 / 1 6 ) D( D u c t ) 30 ( 1 - 3 / 1 6 ) 10 0 ( 3 - 1 5 / 1 6 ) X ( E - 1 ) = F 10 0 ( 3 - 1 5 / 1 6 ) 10(7/16) 57(2-1/4)643(25-3/8) 18(3/4)210(8-5/16) 21 ( 7 / 8 ) G 732(28-7/8) 32(1-5/16)700(27-9/16) 238(9-3/8) 10(7/16) 33 ( 1 - 5 / 1 6 ) 40 ( 1 - 5 / 8 ) 10 0 ( 3 - 1 5 / 1 6 ) 12 2 ( 4 - 1 3 / 1 6 ) 17 8 ( 7 - 1 / 1 6 ) 136 67 356(14-1/16) 21 7 ( 8 - 9 / 1 6 ) 41 ( 1 - 5 / 8 ) 25 0 ( 9 - 7 / 8 ) 23 ( 1 5 / 1 6 ) (4-15/16) (5 - 3 / 8 ) 3-ø2.9(1/8) mount hole Drain pipe(O.D ø32(1-1/4)Fresh air intake ø100(3-15/16)knock out hole 2XE-ø2.9(1/8) (Suspension bolt pitch) Air filter Drain pipe (Integral lift pump outlet)Drain pump (D U C T ) 2X2-ø2.9(1/8) 1 Refrigerant piping (gas)(5-3/8)(2-11/16) (Emergency drain) 2 Refrigerant piping(liquid) Drain pipe(O.Dø32(1-1/4))(Gravity drain) Terminal block(Power source) Terminal block(Transmission) Note 4 Control box (O.Dø32(1-1/4)) Top Top Bottom view Top Bottom Inlet airside view Outlet airside view Opposite pipingside view Pipingside view (43-5/16) (55-1/8) (45-7/16) (57-1/4)(59-1/16)(53-9/16) (47-1/4)(41-3/4)(39-3/8) (51-3/16) (41-11/16) (53-1/2) 2 Liquid pipe1Gas pipe 1058 13581300 Model 1200 11106011001154 1400 ø15.88(5/8) 1454 1500 ø9.52(3/8) 1360 14 100024,30 36,42 Unit:mm(in.) AirinletAiroutlet Note 1.Use an M10 screw for the suspension bolt (field supply). 2.Keep the service space for maintenance at the bottom. 3.This drawing is for 24·30·36·42 KBTU/H models,which have 2 fans. 09·12·15·18 KBTU/H models have 1 fan. 4.If the inlet duct is used,remove the air filter (supplied with the unit), then install the filter (field supply) at the suction side. 5.Heat air to 0°C (32°F) or higher when taking fresh air with a fresh air intake. 24,30 36,42 12,15, Model AEDCBFG Unit:mm(in.) (35-7/16)(37-9/16)(39-3/8)(33-7/8)(31-1/2)(33-13/16)8581000 9860900954 80009,12, ø12.7(1/2)ø6.35(1/4) (3-1/8)78 H (2-7/8)72 J 66(2-5/8) 62(2-1/2) 09 ø9.52(3/8)ø6.35(1/4)62(2-1/2) INDOOR UNIT DIMENSIONS: PEAD-A36AA7 FORM# PEAD-A36AA7 & SUZ-KA36NA2.TH - 202103 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. cl e a r * 1 *1 4 in. (100 mm) or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes (KA09/12/15NA) (KA09/12/15NAH) REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (09/12 KBTU/H) Ø 1/2 (15 KBTU/H) 4 in. ( 1 0 0 m m ) or mo r e 14 in . ( 3 5 0 m m ) or m o r e8 in. (2 0 0 m m ) or more * 2 4 in. ( 1 0 0 m m ) or m o r e Unit: inch(mm) OUTDOOR UNIT DIMENSIONS: SUZ-KA36NA2 Page 1 of 5 1 / 23 THERMADOR® EXCLUSIVE GENERAL PROPERTIES Controls Metal Knobs Sealed Burners Yes Grate Material Cast Iron BURNER PERFORMANCE Total Number of Cooktop Burners 6 Power of Front Left Burner (NG)18,000 and XLO (NG) Power of Back Left Burner (NG)15,000 and XLO (NG) Power of Back Center Burner (NG)15,000 (NG) Power of Front Center Burner (NG)18,000 (NG) Power of Center 12" Electric Griddle (W)N/A Power of Center 12" Electric Grill (W)N/A Power of Back Right Burner (NG)15,000 (NG) Power of Front Right Burner (NG)18,000 (NG) TECHNICAL DETAILS Circuit Breaker (A)15 A Volts (V)120 V Frequency (Hz)60 Hz Plug Type / Receptacle 120V-3 Prong NEMA 5-15 Power Cord Length (in)65" Energy Source Gas Gas Type Natural Gas 6" Water Column (14.9 mb) Min. (USA) Alternative Gas Type LP 11" Water Column (27.4 mb) Min. (USA) Convertible To LP (Kit Required)Yes DIMENSIONS & WEIGHT Overall Appliance Dimensions (HxWxD) (in)8 11/88" x 35 1515/1616" x 25 1313/1616" Required Cutout Size (HxWxD) (in)7 1111/1616" x 35 11/88" x 22 1313/1616" Minimum Distance From Rear Wall (in)6" Min. to Combustible Surface Net Weight (lbs)142 lbs WARRANTY Limited Warranty, Entire Appliance, Parts and Labor 2 Year FEATURES & BENEFITS - Exclusive Star® Burner delivers superior flame spread for more even heating with QuickClean Base® designed for easy cleaning - 2 ExtraLow® burners offer precision simmering, melting or keeping warm - Professional style, continuous cast iron grates - LED Down Lighting is hidden discreetly above the control panel, providing functional and stylish illumination - Restaurant style metal knobs PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE Page 2 of 5 1 / 23 PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36" RANGETOP SIDE VIEW ACCESSORIES (OPTIONAL) PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners PA12CHPBLK 12" Cutting Board PWOKRINGHC Wok Ring PA36WLBC 10" Low Backguard PAKNOBLUWR Metallic Blue Knob Kit PALPKITHW LP Conversion Kit, Pro Rangetops (4 & 6 Burners) PAALTKITH High Altitude Kit, Natural Gas Rangetops, 5,400 ft. to 10,200 ft. Contact Customer Support High Altitude Kit, Gas Rangetops Connected to LP Gas, 10,000 ft. to 10,200 ft. Page 3 of 5 1 / 23 PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP CUTOUT DIMENSIONS Page 4 of 5 1 / 23 36-INCH RANGETOP GAS LOCATION The gas and electrical supply must be located in an area that is accessible without requiring removal of the rangetop. The appliance electrical power cord and gas pipe connection are located on the left rear underside of the rangetop. The junction box must be located within 3 feet (~900 mm) of the rangetop connection. NATURAL GAS REQUIREMENTS: Inlet Connection: 11/22" NPT (min. 33/44" dia. flex line) Supply Pressure: 6" min. to 14" max. water column (14.9 mb to 34.9 mb) Manifold Pressure: 5" water column (12.5 mb) PROPANE GAS REQUIREMENTS: Inlet Connection: 11/22" NPT (min. 33/44" dia. flex line) Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE Page. 14 NEMA 5-15 NEMA 5-20 ELECTRICAL SUPPLY IMPORTANT: The cord supplied with all-burner gas rangetops requires a NEMA 5-15 receptacle as shown here. Local codes my require a different wiring method. WARNING: This appliance is equipped with a three-prong grounding plug for protection against shock hazard and should be plugged directly into a properly grounded receptacle. DO NOT cut or remove the grounding prong from this plug. DO NOT ALTER THIS PLUG. Page 5 of 5 These warranties give you specific legal rights and you may have other rights that vary from state to state. Limited warranty from date of purchase. For complete warranty details, refer to your Use & Care manual, or ask your dealer. Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model number. Specifications are correct at time of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products that are transported from the U.S. for use in Canada. 1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2023 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED. 1 / 23 36-INCH RANGETOP CLEARANCES NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 11/44 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE