Loading...
HomeMy WebLinkAboutFile Documents.901 E Hyman Ave.0009-2022-BRES (5)GENERAL 1.All construction shall conform to the 2015 editions of the International Residential Code (IRC) & International Building Code (IBC), and the City of Aspen amendments. 2.Details not specifically shown on these drawings shall be similar to details for like construction as shown on these drawings. 3.The Contractor shall verify all dimensions and conditions at the job site, and shall report any discrepancies to the Architect and Structural Engineer of Record (S.E.O.R.) before proceeding with work. 4.Refer to Architectural drawings for dimensions and other information not specifically shown on Structural Drawings. Dimensions shown are approximate and are provided as an aid in interpreting the drawings and must be verified with the Architectural drawings. In the event of conflict, dimensions shown on the Architectural drawings shall govern. Notify the S.E.O.R. of any discrepancies prior to constructing the impacted portions of the work. Scaled dimensions shall not be used. 5.No structural members shall be cut, notched or otherwise penetrated unless specifically approved by the S.E.O.R. in advance or as shown on these drawings. 6.Provide openings, curbs, framing, supports and attachments for items as indicated on Architectural, Mechanical, Electrical or other drawings included in the Construction Documents. 7.Where these General Notes and typical details are in conflict with the Specifications, these Notes and Details shall govern. MANUFACTURED WOOD PRODUCTS 1.Manufactured wood I-joists shall be installed in accordance with the manufacturer's recommended details for blocking, bracing, bearing and connections. See plan for size, depth and product designations. Any alternate products shall be submitted to the engineer for written approval prior to construction. 2.Laminated Veneer Lumber (LVL) beam & column plies shall be 1 3/4" in width with number of plies and depths as noted on plan. LVL shall have the following minimum working stresses: Fc pll=2,510 psi, Fb=2,600 psi, Fv=285 psi, E=2,000,000 psi. 3.Laminated Strand Lumber (LSL), beams (1 3/4" min) and rimboard (1 1/4" min) shall be as noted on plan, with the following minimum working stresses: Fc pll=1,400 psi, Fb=1,700 psi, Fv=400 psi, E=1,300,000 psi. 4.Versa-Stud (1 1/2" min) shall be noted on plan, with the following minimum working stresses: Fc pll=3,000 psi, Fb=2,400 psi, E=1,700,000 psi. 5.Parallel Strand Lumber (PSL) beams shall be as noted on plan with the following minimum working stresses: Fb=2,900 psi, Fv=290 psi, E=2,000,000 psi. 6.Parallel Strand Lumber (PSL) columns shall be as noted on plan with the following minimum working stresses: Fc pll=2,500 psi, Fb=2,400 psi, Fv=190 psi, E=1,800,000 psi. 7.Glulam (GL) beams shall be as noted on plan with the following minimum working stresses: 24F-V4, Fb(tension zone)=2,400 psi, Fv=265 psi, E=1,800,000 psi. All mult-span beams, including cantilever conditions, shall be 24F-V8 unless noted otherwise in the drawings. 8.Manufactured wood products as noted above shall be installed per manufacturer's specifications. 9.Manufactured wood products in contact with concrete or masonry foundation or exposed to exterior conditions shall be treated per manufacturer's specifications. 10.Wood manufactured products other than those noted, which have ICC-ES approval, may be used with approval by the engineer of record. Substitutions made by the Owner or Contractor shall include all connection hardware as required for sizes used, and shall have equivalent load ratings as those called for on the Drawings. STRUCTURAL ERECTION AND BRACING REQUIREMENTS 1.The Structural Drawings illustrate the completed structure with all elements in their final positions, properly supported and braced. 2.The Contractor, in the proper sequence, shall provide shoring and bracing as required during construction to achieve the final completed structure. Design, sequencing, location, placement, etc. of bracing and shoring is the responsibility of the Contractor. 3.The Contractor shall be responsible for the safety of the building and workers during construction. The Contractor shall comply with all applicable safety regulations. BACKFILLING 1.Contractor shall not backfill against basement and/or retaining walls until all supporting elements (ex: concrete slabs and/or floor framing) are in place and securely anchored, or until adequate temporary shoring is installed. 2.Contractor shall verify type of backfill material with Geotechnical Engineer prior to backfilling. FASTENER AT NEAR FACE FASTENER AT FAR FACE (3-PLY & 4-PLY ONLY) PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 10d NAILS @ 12"o.c.ONE FACE EA FACE PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 12d NAILS @ 12"o.c.ONE FACE EA FACE 2" 12"/24"o.c.2" PLY TO PLY CONNECTION 3-PLY2-PLY 3 ROWS 16d NAILS @ 12"o.c.ONE FACE EA FACE 4-PLY EA FACE2 ROWS 1/4"x6" SDS SCREWS @ 24"o.c. 4-PLY 3 ROWS 1/4"x6" SDS SCREWS @ 24"o.c.EA FACE FOR COLUMNS OVER 3-PLY, ATTACH EACH ADDITIONAL PLY w/ (2) ROWS OF 10d NAILS @ 12"o.c. SAWN LUMBER (2" NOM. THICKNESS) CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH < 14" CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH > = 14" CONNECTION SCHEDULE 2-PLY MEMBER 3-PLY MEMBER 4-PLY MEMBER ELEVATION 1. FLOOR SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS FLOOR SHEATHING, RATED STURD-I FLOOR, 24" o.c, 23/32" THICK, T & G OR 1 1/8" WARMBOARD-S. FLOOR SHEATHING SHALL BE GLUED AND FASTENED TO FLOOR JOISTS & BEAMS USING ADHESIVES CONFORMING TO APA SPECIFICATION AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REMOVE WATER, DUST AND DEBRIS FROM JOISTS. APPLY GLUE TO JOISTS & BEAMS AND COMPLETE ALL FASTENING BEFORE GLUE SETS. FLOOR SHEATHING USED AT EXTERIOR DECKS SHALL BE LABELED "EXTERIOR" OR "EXPOSURE 1". 2. ROOF SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS ROOF SHEATHING, LABELED "EXTERIOR" OR "EXPOSURE 1", RATED SHEATHING, 40/20, 5/8" THICK 3. FLOOR AND ROOF SHEATHING LAYOUT: 3-SPAN CONTINUOUS - MIN, PERP TO FRAMING MEMBERS 2'-0" MIN LAP - U.N.O. WOOD AND TIMBER FRAMING 1.All wood and heavy timber construction shall conform to the American Institute of Timber Construction (AITC) and National Design Specification (NDS) Standards, latest edition. 2.Structural framing lumber shall be at a minimum, as noted below, unless noted otherwise, and shall have a maximum moisture content of 19% at time of delivery. SHEATHING NAILING SHEATHING APPLICATION FASTENERS NAIL SPACING COMMENTS@ INTERMEDIATE SUPPORTS @ PANEL EDGES WOOD FLOOR 8d COMMON (0.131 Ø)12"6"GLUED (SEE NOTE 1) WOOD ROOF 8d COMMON (0.131 Ø)12"6"- DBL 2x TOP PL TYP U.N.O. (2) 10d @ CORNER & INTERSECTION LAPS 10d COMMON @ 24"o.c. (2) 10d ADD'L (8) 10d COMMON MIN BTWN SPLICES TYPE SPECIES GRADE Fb (MIN) Existing 2x structural Joists, Rafters & Headers Hem Fir No. 2 850 psi 2x Structural Joists, Rafters & Headers Douglas Fir-Larch No. 2 900 psi 2x Studs, Posts & Plates Douglas Fir-Larch No. 2 900 psi Versa-Stud 1.7E 2,400 psi Plates Douglas Fir-Larch No. 2 900 psi LSL 1.3E 1,700 psi Stringers, Beams & Posts (4x)Douglas Fir-Larch No. 1 1,000 psi Stringers, beams (6x & greater)Douglas Fir-Larch No. 1 1,350 psi Posts (6x & greater)Douglas Fir-Larch No. 1 1,200 psi SPECIAL INSPECTION 1.The owner shall employ a special inspector per IBC Chapter 17. The special inspector shall submit a copy of all his reports to the Owner, Architect, Structural Engineer and the Building Department. When the work is completed, the special inspector shall submit a final signed report stating whether the work was, to the best of his knowledge, in conformance with the approved set of plans and specifications and the applicable workmanship provisions of the building code. The S.E.O.R. will make visits to the site to observe general compliance with the approved structural plans, specifications and change orders. The contractor shall coordinate with the special inspector in order to ensure that the special inspection as indicated below can be performed with minimal impact to the project schedule. 2.Special inspection is required for the following types of work. Refer to Chapter 17 of the 2015 IBC for additional testing and specific requirements. 2.1.All cast-in-place concrete work & reinforcing placement, except nonstructural concrete (periodic). 2.2.All masonry construction (periodic per IBC 1705.4). 2.3.All bolts and embeds in concrete (continuous if wet stabbed, periodic if tied). 2.4.All shop and field welding (periodic). 2.5.All high-strength bolted connections (periodic). SHOP AND ERECTION DRAWINGS 1.The Contractor shall furnish a PDF set of shop and erection drawings for review to the Architect and Structural Engineer of Record prior to fabrication for the following items: 1.1.Wood roof trusses 1.2.Structural Insulated Panels (SIP's) 1.3.Structural steel 1.4.Concrete and masonry reinforcing steel 1.5.Concrete mix designs 1.6.Glazing and intermediate structure per manufacturer for large areas of wall 2.The manufacture, fabrication or erection of above noted items prior to written review by the Architect and Structural Engineer of Record is at the sole risk of the Contractor. A35 OR LS50 CLIP @ KING STUD TO TOP & BOT PL's @ WALL OPNG WIDTH > 4'-0" & (2) A35 OR LS50's @ WIDTH > 7'-0" - TYP U.N.O. 2x SILL PL - USE (2) 2x PL's w/ A35 EA END @ EXT WALL OPNG 8'-0" & GREATER - TYP (1) 2x6 TRIM STUD MIN, TYP U.N.O. PER PLAN (2) 2x6 HDR MIN, TYP U.N.O. PER PLAN (2) 16d COMMON, END NAIL OR (4) 8d COMMON TOENAIL, EA STUD - TYP BOT/SILL PL - SEE PLAN NOTES OR SPECIFIC DETAILS FOR ANCHOR BOLT SIZE & SPACING 2x6 STUDS @ 16"o.c. PER PLAN & DETAILS - U.N.O 2x SOLID BLKG REQ'D AT CEILING LINES & AT ALL EDGES OF EXT WALL SHTG (1) 2x6 KING STUD MIN, TYP U.N.O. PER PLAN (4) 16d COMMON (2) 16d COMMON, END NAIL, TOP PL TO EACH STUD - TYP TYPICAL FRAMING CONNECTION SCHEDULE (MINIMUM U.N.O.)1, 2 NAILING TYPE Joists or Rafters to T.O. Double Top Plate, Sill Plate or Beam (3) 10d Toenail Rim Joist or Structural Fascia to Joists, Rafters (2) 16d, (1) T&B End Nail Sole Plate to Sill Plate (3) 10d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg - Typ (2) 16d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg at BWP (3) 16d @ 16"o.c.Face Nail Double Studs, Built-up Corner Studs, Trim Studs to King Studs1 Per Typ Detail Rim Joist to Top Plate 8d @ 6"o.c.Toenail Blkg Btwn Rafters & Joists to Top Plate, Sill Plate or Beam 8d @ 6"o.c. (3) min per block Toenail 2x Decking to Joists (2) 10d each joist Face Nail 1. Refer to Typical Multiple Ply Beams & Columns Detail for additional information. 2. Refer to Typical Framed Wall Detail for additional information. TYP DBL TOP PL CONN's ATTACH ALL KING, TRIM STUD & HEADER, BEAM PLIES PER TYP MULTIPLE PLY BM & COL DETAIL FRAMING MEMBERS REINFORCED CONCRETE 1.All concrete design is based on the "Building Code Requirements for Reinforced Concrete", ACI 318, latest edition, associated Commentary (ACI 318R), and IRC/IBC Requirements. 2.All structural concrete shall be in accordance with ASTM C39 and properties noted. Minimum compressive strengths noted are required at 28 days. Typical unless noted otherwise. 2.1.All concrete exposed to freeze-thaw cycles or deicing chemicals shall be air entrained 5-7%. 2.2.For structural concrete in buildings of occupancy categories R-2 & R-3: Minimum compressive strength = 3,000 psi. Garage slab or exterior: Minimum compressive strength = 3,500 psi. 2.3.Structural concrete for all other structures: Minimum compressive strength = 3,500 psi & maximum w/cm ratio of 0.50. Exposed to freeze-thaw cycles: Minimum compressive strength = 4500 psi & maximum w/cm ratio of 0.45. Exposed to deicing chemicals: Minimum compressive strength = 5000 psi & maximum w/cm ratio of 0.40. 2.4.Stained or polished floor slabs: Minimum compressive strength = 4000 psi with low pozzolanic material ratios. 3.All concrete shall be consolidated using mechanical vibrators. 4.All concrete work shall conform to the requirements of the IBC and ACI Standard 318, latest edition, of the American Concrete Institute (ACI), unless shown or noted otherwise on these drawings. 5.Aggregate shall conform to ASTM C33. 6.Cement shall be ASTM C150, Type I or Type II modified. 7.Concrete shall be placed in accordance with ASTM C94 and ACI Standard 304. 8.All embedded items shall be placed accurately and secured prior to beginning concrete placement. 9.Construction joints shall be located so as not to impair the strength of the structure. Construction joints shall comply with ACI 318, unless noted otherwise. 10.Concrete mix designs shall be submitted to the Architect & S.E.O.R. for approval prior to placement of any concrete. 11.Reinforcement and embedded items shall be free of excessive scale, rust, dirt, grease, & all or any other substance that will impair bond with concrete. REINFORCING STEEL 1.All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice. 2.Except where otherwise noted on the Drawings, reinforcing bars shall conform to ASTM Specification A615 and shall be Grade 60. Ties and field-bent bars as noted on plan shall be Grade 40. All reinforcing bars to be welded shall conform to ASTM A706. 3.Welded wire fabric reinforcement shall conform to ASTM A185 and shall be sheet-type; roll-type is not acceptable. 4.Coverage for reinforcing bars shall be in accordance with the requirements of the IBC, the ACI Standard 318 and in the Table below, unless shown otherwise on the Drawings. 5.Lap splices for reinforcing bars shall be 57 bar diameters (24" minimum) for concrete reinforcement and 72 bar diameters (36" minimum) for masonry reinforcement unless shown otherwise on the Drawings. Wire bars together at laps or splices. Stagger laps in adjacent horizontal bars a minimum of the required splice length. Hooks shall be ACI standard hooks unless shown otherwise. Welded wire fabric shall be spliced by lapping a minimum of 12 inches, or (2) cross wires, whichever is greater. STRUCTURAL STEEL 1.All detailing, fabrication, and erection of structural and miscellaneous steel shall be in accordance with the requirements of the American Institute of Steel Construction (AISC) Code of Standard Practice, latest edition, and the American Welding Society (AWS) Specifications. 2.All structural steel rolled shapes, except angles and plates, shall conform to ASTM A992, 50 ksi. 3.Angles, channels & plates shall conform to ASTM A36, 36 ksi, unless otherwise noted on the Drawings. 4.Pipes shall conform to ASTM A53, Grade B, 35 ksi. 5.Tube shapes (HSS) shall conform to ASTM A500, Grade B, rectangular shapes = 46 ksi & round shapes = 42 ksi. 6.All bolts for steel-to-steel connections shall conform to ASTM A325, unless otherwise noted on the Drawings. 7.All anchor bolts shall conform to ASTM F1554 Gr. 36, unless otherwise noted on the Drawings. 8.All shear studs shall conform to ASTM A108 & shall be welded to steel beams for full shear capacity. 9.All welding shall be in accordance with the requirements of the IBC and the Structural Welding Code, AWS D1, latest edition, by the American Welding Society. Shop welding shall be performed in shops approved by the Building Official, per IBC. Welding shall be done using E70XX electrodes, unless noted otherwise on the Drawings. 10.Expansion bolts and epoxy anchors called for on the Drawings shall be Hilti or approved equivalent, with embedment as shown on the Drawings. Expansion bolts shall be Hilti Kwik Bolt 3. 11.Powder actuated fasteners shall be Hilti DNI or approved equivalent, with full penetration into steel members, unless otherwise noted on the Drawings. 12.Steel, including bolts & anchors, in contact with earth, or as otherwise noted on the Drawings, shall be hot dip galvanized or prime painted. Do not paint within 3" of field welds until welds are completed. MINIMUM CONCRETE COVER FOR REINFORCEMENT1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER No. 6 thru No. 18 bars 2" No. 5 bar, W31 or D31 wire, and smaller 1 1/2" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND Slabs, Walls, Joists:No. 14 and No. 18 bars 1 1/2 " No. 11 bar and smaller 3/4" Beams, Columns:Primary reinforcement, ties, stirrups, spirals 1 1/2" 1.Minimum concrete cover specified or for cast-in-place, nonprestressed concrete DESIGN LOADS 1.ROOF LOADS Dead Load .......................................20 psf Flat Roof Load (Snow)*....................70 psf 2.FLOOR LOADS Dead Load .......................................32 psf Live Load .........................................40 psf 3.LATERAL LOADS Seismic Design Category.................C Basic Wind Speed ...........................115 mph Exposure Category .........................B 4. IMPORTANCE FACTOR ...........................1.0 * No duration of load increase was used in design FOUNDATIONS 1.Concrete foundations are designed based on the following assumed soil values (full dead load plus full live load, placed on natural soils and/or engineered structural fill per soils engineer). Soil Density = 120 pcf (Assumed) Allowable Bearing Pressure = 2,000 psf Lateral At-Rest Earth Pressure = 50 pcf Lateral Active Earth Pressure = 40 pcf Lateral Passive Earth Pressure = 400 pcf (Ultimate) Coefficient of Friction for Footing = 0.50 (Ultimate) Frost Depth = 36" min 2.Soils conditions and types, at the proposed foundation bearing elevations, shall be verified as adequate for the noted soil values, by a representative of a qualified Geotechnical Engineer (employed by Owner) during excavation. 3.Proper surface and below grade perimeter drainage shall be installed per Civil & Geotechnical Engineers to relieve foundations from hydrostatic pressures. 4.It is the responsibility of the Contractor to review the Geotechnical Engineer's recommendations and notify the Architect and/or S.E.O.R. if any changes to the design are required prior to start of construction. SCALE: NTS1TYP FLOOR & ROOF SHEATHING SCALE: 3/4" = 1'-0"2 TYP WALL FRAMING DETAIL SCALE: NTS3TYP MULTI-PLY BEAMS & COLUMNS MASONRY 1.Concrete masonry units (CMU's) shall conform to ASTM C90, Grade N, and shall have a minimum 28 day compressive strength of 1900 psi. 2.Compressive strength of masonry construction (F'm) shall be 1500 psi minimum based on net compressive area. 3.Mortar for CMU's shall be Type M or Type S, ASTM C270. Admixtures shall not be used unless approved by the Architect. The use of masonry cement is not permitted. Minimum compressive cube strength shall be 1900 psi. 4.Grout used in masonry construction shall be coarse grout, and shall conform to ASTM C476. Grout shall develop a minimum compressive strength of 3000 psi at 28 days. 5.Reinforce all masonry walls with continuous horizontal 9 gauge ladder or truss type reinforcement meeting ASTM A82. Maximum vertical spacing of joint reinforcing shall be 16 inches. 6.All walls shall be reinforced vertically at wall ends, corners, each side of door or window openings, and as otherwise noted on plans. Provide continuous horizontal bond beams at top of walls and as otherwise noted. 7.All block shall be laid up in running bond. 8.Grout shall be consolidated by mechanical vibration during placement. Grout pours less than 12" may be puddled for consolidation. 9.All bolts, anchors and embedded items shall be grouted in place, unless otherwise noted on the Drawings. Anchor bolts shall have at least 1 inch of grout between the bolt and the masonry shell, and shall be headed or hooked. GROUT, ADHESIVE & EPOXY 1.All grout beneath column base plates, or steel beams at bearing shall be non-metallic, non-shrink high strength grout by BASF "Masterflow", or approved equal installed to manufacturer's specifications. 2.All structural construction adhesive specified shall be Loctite PL Premium Fast Grab or approved equal & shall be installed to manufacturer's specifications. 3.Epoxy shall be Hilti HIT-HY 200 or approved equivalent, unless otherwise noted on the Drawings.3.Provide solid blocking at supports between joists and rafters. Within floor joist spaces beneath solid or built-up posts, provide solid blocking with area same as post above. 4.All plywood shown on these drawings shall be minimum C-D grade with exterior glue in accordance with DOC PS 1 and comply with IBC. 5.Sill plates shall be of naturally durable wood, or Zinc Borate treated LSL or Douglas Fir-Larch per IBC with Fc perp = 625 psi, minimum and shall be protected for dry use. 6.All wood framing shall be preservative pressure treated when in contact with concrete or masonry foundation or exposed to exterior conditions. All fasteners used to connect pressure-treated wood shall be hot-dipped galvanized (HDG) or stainless steel. 7.Except as noted otherwise, provide minimum nailing as specified in IBC. Structural nailing shall be with common nails, unless otherwise noted on the Drawings. Nails exposed to weather shall be galvanized. Nails used to connect preservative treated wood shall be hot dipped galvanized (HDG) or stainless steel. 8.Metal timber connectors shall be Simpson Strong-Tie or equivalent. Hardware specified is for specific member size & manufacturer as show on the structural drawings. Hanger slope, skew & top flange shall be designated by the contractor as required. Simpson connectors for preservative treated wood or connectors in contact with concrete shall be ZMAX or HDG, or as otherwise recommended by specific connector supplier. Install all connectors in accordance with manufacturer's instructions for maximum rated loads. 9.Bolts used as timber-to-steel or timber-to-timber connectors shall be ASTM A307 unless noted otherwise on the Drawings. Bolts shall be installed in accordance with the requirements of the latest edition of the National Design Specification for Wood Construction (NDS) by the American Wood Council. Bolts used to connect pressure-treated wood shall be HDG or stainless steel. 10.Lag screws shall be ASTM A307. Holes for lag screws shall be bored the same depth and diameter as the bolt shank. The remaining depth of penetration shall be bored per NDS requirements. Lag screws used to connect pressure-treated wood shall be HDG or stainless steel. 11.Provide malleable iron washers or equivalent cut plate washers under all nuts, bolts or lag screw heads which bear on wood. 12.Wood screws shall be steel per NDS requirements. Pre-drill holes to prevent splitting as recommended in the NDS. 13.Wood members shall be cut or notched only as shown on the Structural Drawings. 14.Provide cross bridging, solid bridging or other lateral support for all framing members in accordance with the requirements of IBC. 15.Except where more stringent construction is shown on the Drawings, wood construction shall comply with the requirements of the IBC, latest edition, as a minimum. AB ANCHOR BOLT ABV ABOVE ACI AMERICAN CONCRETE INSTITUTE ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR ALT ALTERNATE APA AMERICAN PLYWOOD ASSOC ARCH ARCHITECT OR ARCHITECTURAL B.O.BOTTOM OF BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BOT BOTTOM BOW BOTTOM OF WALL BRG BEARING BTWN BETWEEN BWP BRACED WALL PANEL CANTD CANTILEVERED CCW COUNTER-CLOCKWISE CIP CAST-IN-PLACE CJ CONTROL JOINT CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT CNTRD CENTERED COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CW CLOCKWISE DBA DEFORMED BAR ANCHOR DEFL DEFLECTION DIAG DIAGONAL DL DEAD LOAD E.F.EACH FACE E.N.EDGE NAILING E.W.EACH WAY EL ELEVATION ELEV ELEVATOR EMBED EMBEDMENT EQ EQUAL EQUIV EQUIVALENT EXISTG/(E)EXISTING EXP EXPANSION EXT EXTERIOR F.D.FLOOR DRAIN FDN FOUNDATION FLG FLANGE FS FULL SAWN FTG FOOTING G.C.GENERAL CONTRACTOR GA GAUGE/GAGE GALV GALVANIZED, HOT DIP GB GRADE BEAM GL GLUE-LAMINATED MEMBER H.A.S.HEADED ANCHOR STUD HDR HEADER HGR HANGER HORIZ HORIZONTAL HSS HOLLOW STRUCTURAL STEEL HT HEIGHT I.F.INSIDE FACE IBC INTN'L BUILDING CODE INT INTERIOR IRC INTN'L RESIDENTIAL CODE ISO ISOLATION JST JOIST JT JOINT K KING KSI KIPS PER SQUARE INCH LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LOC LOCATION LT LIGHT LVL LAMINATED VENEER LUMBER MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MF MOMENT FRAME MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTL METAL N.S.NOT SHOWN NTS NOT TO SCALE o.c.ON-CENTER O.F.OUTSIDE FACE OPNG OPENING OPP OPPOSITE OSB ORIENTED STRAND BOARD P.E.PRE-ENGINEERED P.T.PRESSURE TREATED PAF POWER-ACTUATED FASTENER PC PRE CAST PEN PENETRATION PERP PERPENDICULAR PL PLATE PLCS PLACES PLF POUNDS PER LINEAR FOOT PLL PARALLEL PLY PLYWOOD PSF POUNDS PER SQUARE FOOT PSL PARALLEL STRAND LUMBER R RADIUS R.D.ROOF DRAIN RE:REFER TO REINF REINFORCING/MENT REQD REQUIRED RS ROUGH SAWN RTU ROOF TOP UNIT S.O.G.SLAB ON GRADE SCHED SCHEDULE SEOR STRUCTURAL ENGR OF RECORD SHT SHEET SHTG SHEATHING SIM SIMILAR SP SPACE OR SPACING SPECS SPECIFICATIONS SS STAINLESS STEEL STD STANDARD STGD STAGGERED STL STEEL STRUCT STRUCTURAL SYM SYMMETRICAL T TRIMMER T&B TOP AND BOTTOM T&G TONGUE AND GOOVE T.O.TOP OF TOF TOP OF FOOTING TOL TOP OF LEDGE TOS TOP OF SLAB TOW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD w/WITH WP WORK POINT WWF WELDED WIRE FABRIC SHEAR WALL (SW) PANELS 1.All bearing walls, including unlabeled, hatched Shear Walls, shall be continuously sheathed as Typical Exterior or Interior Shear Wall, accordingly. 2.Typical Exterior Shear Wall shall be 7/16" APA rated OSB or plywood attached to studs w/ 8d common or galvanized box nails (1 3/8" stud penetration) @ 6"o.c. at panel edges & 12"o.c. at intermediate supports. Block all panel edges. 3.Typical Interior Shear Wall shall be 5/8" gypsum board, both sides of wall, attached to studs w/ 6d cooler nails, 0.120”Ø x 1 3/4", min, 3/8" head (or No. 6 1 1/4" Type S or W screws), spaced at 4"o.c. at all supports, studs & plates. Studs shall be spaced @ 24"o.c. max @ panels. 4.All hatched Shear Walls are critical to the current lateral force resisting system design. They shall not be modified. 5.Special Shear Walls, holdown straps & anchors, as required, are denoted per plan and shall be constructed per schedules shown on these drawings. 6.Nails for gyp board attachment shall be Dritite or 'cooler' type nails. 7.Nails for plywood shall be common nails. Use of pneumatically driven nails is subject to approval by the building department and structural engineer. Do not overdrive nails. 8.Plywood sheathing shall be standard (C-D) grade with exterior glue. 9.Gypsum board and plywood to conform to IBC tables 2306.4.5 and 2306.4.1. 10.Install 2x continuous blocking at horizontal panel joints/edges as needed for edge nailing. 11.Provide edge nailing to stud or post where holdowns occur. STRUCTURAL GENERAL NOTES ABBREVIATIONS EXISTING FLOOR JOIST OR ROOF RAFTER EXISTING FLUSH BEAM EXISTING DROPPED BEAM EXISTING HEADER BEAM OR LINTEL STRUCTURAL SYMBOLS LEGEND EXISTING MASONRY WALL & CONCRETE FOOTING CONCRETE WALL & FOOTING EXISTING CONCRETE WALL & FOOTING EXISTING LEDGER EXISTING WALL BELOW FRAMING TO BE REMOVED EXISTING BEARING STUD WALL BELOW FRAMING EXISTING ROOF RAFTER OR FLOOR JOIST SPAN, ARROWS DESIGNATE BEARING LOCATIONS ROOF OVERFRAMING PER TYPICAL DETAIL X STEEL OR WOOD COLUMN WHICH SUPPORTS FRAMING OR LOADS FROM ABOVE SEE WALL FRAMING NOTES FOR MIN SIZE, NUMBER, & TYPE FLOOR JOIST OR ROOF RAFTER JOIST HANGER OR BEAM TO BEAM CONNECTION RE: HANGER SCHEDULE FOR CONNECTION, U.N.O. FLUSH BEAM VERTICAL STEP IN FLOOR WOOD STUD STRUCTURAL WALL ABOVE NON-BEARING STUD WALL BELOW FRAMING REVISION CLOUD INDICATING REVISED ITEMS REVISION NUMBER CORRESPONDS WITH REVISIONS IN TITLE BLOCK STEEL OR WOOD COLUMN FROM ABOVE OR BTWN BEAMS WHICH ARE SUPPORTED ON FRAMING, MIN WIDTH TO MATCH SUPPORTED FRAMING, U.N.O. ROOF RAFTER OR FLOOR JOIST SPAN, ARROWS DESIGNATE BEARING LOCATIONS DROPPED BEAM HEADER BEAM OR LINTEL WALL STEP, POINTS IN DIRECTION OF DOWN MASONRY WALL & CONCRETE FOOTING LEDGER BEARING STUD WALL BELOW FRAMING MOMENT CONNECTION SHEAR WALL (SW) PANEL & BEARING WALL BELOW FRAMING HOLDOWN FRAMING OR FOUNDATION ANCHOR PER PLAN & SCHEDULE EXISTING STEEL OR WOOD COLUMN TO BE REMOVED EXISTING FRAMING TO BE REMOVED EXISTING VERTICAL STEP IN FLOOR EXISTING WALL STEP, POINTS IN DIRECTION OF DOWN HOLDOWNS INSTALLED AT BASE OF WALL PANEL ABOVE SHEAR WALL (SW) PANEL & NON-BEARING WALL BELOW FRAMING S1 H1 EXISTING SHEAR WALL (SW) PANEL & BEARING WALL BELOW FRAMING STONE VENEER SLOPE ROOF SLOPE ARROW, POINTS TO DOWN EDGE OF FLOOR DECKING OR SHEATHING EXISTING STEEL OR WOOD COLUMN WHICH SUPPORTS FRAMING OR LOADS FROM ABOVE EXISTING STEEL OR WOOD COLUMN FROM ABOVE OR BTWN BEAMS WHICH ARE SUPPORTED ON FRAMING PROJECT # : 22.006C DRAWN BY: SL CHECKED BY: SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 UN I T # 5 R E M O D E L 90 1 E H Y M A N A V E # 5 AS P E N , C O L O R A D O DATE: ISSUE: PLOT DATE: 5/25/2022 05/25/2022 PERMIT S0.01 GENERAL NOTES & TYP DETAILS 05/25/2022 SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. 05/31/2022 justinh 05/25/2022 SCALE: 3/4" = 1'-0" RE: x/x.xxxx 22.006C PLANS (2022-04-28) 1 TYP STL BM AT WOOD COL END PL 3/8" SOLID WOOD OR STEEL SHIM AS REQ'D COL PER PLAN CNTRD BELOW BEAM (2) 5/8"Ø LAG SCREWS, ONE EA SIDE OF WEB @ BM GUAGE 5" MIN PEN INTO TOP PL/COL CONT DBL 2x TOP PL AS OCCURS STL BM PER PLAN 2x NAILER AS REQ'D TYP AT FLATS 3/161/2" PER PLAN T.O. STL SCALE: 3/4" = 1'-0" RE: x/x.xxxx 22.006C PLANS (2022-04-28) 2 STL BM AT (E) TIMBER PERP BM PER PLAN w/ PACKOUT PER TYP DTL (E) JOIST & HANGER PER PLAN (E) BM PER PLAN SCALE: 3/4" = 1'-0" RE: x/x.xxxx 22.006C PLANS (2022-04-28) 3 TYP WF BM PACKOUT & 2x TOP PL RIPPED TOP PL TO MATCH BM FLANGE WIDTH, GLUE TO TOP FLANGE OF BM & ATTACH w/ 0.157Ø P.A.F. STGD @ 8"o.c.w /1/2" PEN INTO STL - TYP AT STL BM FLANGES <= 1/2". AT STL BM FLANGES > 1/2", GLUE TO TOP FLANGE OF BM & ATTACH w/ (2) ROWS OF 1/2"Ø THRU BOLTS AT 48"o.c. ADHESIVE SHALL BE PER GENERAL NOTES ON S0.001 MULTIPLE TOP PL's SHALL BE ATTACHED TO BASE TOP PL w/ 10d COMMONS STGD @ 6"o.c. (2) ROWS 1/2"Ø THRU BOLTS @ 48"o.c. MIN (4) BOLTS PER PACKOUT MEMBER 2x OR LVL OUTER PLY SPACER BLKG BEAR ON BOT FLANGE & FLUSH w/ OUTER EDGE ONE SIDE SHOWN, RE: PLAN FOR ONE SIDE OR BOTH SIDES TO BE PACKED OUT 2 1 / 2 " 7 5 / 8 " 2 1 / 2 " PER PLAN T.O. STL SCALE: 3/4" = 1'-0" RE: x/x.xxxx 22.006C PLANS (2022-04-28) 4 TYP STL BM-COL BRG CAP PL 1/2 (4) 5/8"Ø THRU-BOLTS AT BM GAUGE BM PER PLAN STIFF PL 3/8 CNTRD ON COL TYP AT FLATS 3/16 3/16 PER PLAN T.O. STL 3/16 3" COL PER PLAN STIFF PL 3/8 CNTRD ON COL CAP PL 1/2 (4) 5/8"Ø THRU-BOLTS AT BM GAUGE COL PER PLAN 1 1/2" TYP BM PER PLAN PL 1 4 x 4" EA SIDE w/ (2) 1 2"Ø BOLTS @ 3"o.c. SCALE: 3/4" = 1'-0" RE: x/x.xxxx 22.006C PLANS (2022-04-28) 5 COL TO STL BM BELOW TYP 3/16 (E) STL BM NEW COL PER PLAN BASE PL 1 2 MIN x 5 x 0'-5" SHIM PL 1 2 MIN x 7 x 0'-7" (E) FLOOR DECKING ALT: DIRECT WELD COL TO BM FLANGE BRG PL 1 4 x 4 41 2" BACK PL 1 4 STIFF PL 1 4 CNTRD 1/4TYP1/4 (E ) 3 x 1 2 W12x30 - CONT (E ) 4 x 1 2 (E ) 4 x 1 2 (E ) 4 x 1 2 (E) ( 3 ) 2 x 4 (E ) ( 3 ) 2 x 4 ( E ) ( 3 ) 2 x 4 ( E ) ( 3 ) 2 x 4 ( E ) ( 3 ) 2 x 4 (E) (4) 2x4 - W E L D T O ( E ) B M B E L O W RE : 5 / S 2 . 0 1 HS S 3 1 / 2 x 3 1 / 2 x 1 / 4 R E 4 / S 2 . 0 1 (4) 2 x 4 2 S2.01 1 S2.01 FULL DEPTH SIDE PL 3/8x0'-6 5/8" EA SIDE w/ BRG PL 3/8x0'-3 1/2" AT EA TIMBER JOIST LIVING ROOM KITCHEN BATHROOM ENTRY OF F I C E BEDROOM (5) 2 x 4 (E)(3) 2x4COL TO BEAR ON STEEL BM BELOW (E) 2x12 @ 16"o.c. w/ LUS210 TO NEW BM PACKOUT (E) FRAMING TO REMAIN - TYP U.N.O. 3"Ø MAX PLUMBING PENETRATION THRU FLOOR BM BELOW 2'-0" 3"Ø MAX PLUMBING PENETRATION THRU FLOOR BM BELOW 2'-0" ALL EXISTING STRUCTURE IS TO REMAIN - U.N.O. CONTRACTOR SHALL FIELD VERIFY ALL NOTED EXISTING STRUCTURE PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE S.E.O.R. OF ANY DISCREPANCIES BRG CONN SIM TO 1/S2.01 BM TO EXTEND TO SUPPORT (E) TIMBER JOIST INSTALL NEW 4x12 OVER NEW WALL V.I.F. PROJECT # : 22.006C DRAWN BY: SL CHECKED BY: SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 UN I T # 5 R E M O D E L 90 1 E H Y M A N A V E # 5 AS P E N , C O L O R A D O DATE: ISSUE: PLOT DATE: 5/25/2022 05/25/2022 PERMIT UPPER FLOOR FRAMING PLAN SCALE: 1 4" = 1'-0"A PARTIAL UPPER FLOOR FRAMING PLAN & DETAILS N S2.01 05/25/2022 05/31/2022 justinh 05/25/2022 2 layers of 5/8" type X gyp required to wrap all sides of each new column for required 1 hour fire rated protection. Overlap edges of layers so that joints do not align between layers.