Loading...
HomeMy WebLinkAboutFile Documents.1265 Red Butte Dr.0032-2023-BCHO (4) PO BOX 8610 • AVON, CO 81620 • Telephone 970-845-7910 Fax 970-845-7522 • E-mail drader@raderengineering.co 06/21/2023 Mr. Carlos Rodríguez Timberline Construction 204 Park Ave. Ste 2D Basalt CO. 81621 Via email: carlos@timberlineconstruct.com RE: Fenestration Calculations 1265 Red Butte Aspen, CO 81611 REI Job No. 23018.00 Carlos, Per your request, we have updated the fenestration calculations for the 1265 Red Butte project with a 2-pane window. Calculations for non-NFRC rated assemblies are performed per ASHRAE Fundamentals 2021, Chapter 15 “Determination of Fenestration U-Factor”. Refer to the attached Appendix I for the Fenestration Performance Calculations. Results:  Total Weighted Assembly U-Value = 𝟎.𝟐𝟖 𝑩𝑻𝑼 𝒉𝒓∙𝒇𝒕𝟐∙°𝑭 Method:  Determine the U-Value for three sections of each fenestration assembly separately. o Center of glass (Ucg) o Edge of glass (Ueg) o Window frame (Uf)  Divide fenestration assembly into appropriate sections.  Calculate the weighted average U-Value (UT), by area, of the three sections for each fenestration assembly. 𝑈் =௎಴ಸ ஺಴ಸା௎ಶಸ஺ಶಸ ା௎ಷ஺ಷ ஺೅ Assumptions & Provided Information:  All glass geometries are taken from the email correspondence on 06/20/2023 and Plans dated 10/05/2022.  The Center of Glass U-Values were calculated using the Lawrence Berkeley National Laboratory Window 7.8 software program. o Ucg-Value for the Cardinal 6mm LoE366-6.CIG-i89-6.CIG assembly is 0.224 ஻்௎ ௛௥∙௙௧ మ ∙°ி  The edge of glass is considered to be the glass within 2” of the frame and divider.  The Edge of Glass delta for the U-Value was interpolated from data in ASHRAE Table 4, page 15.9 and corresponding center of glass information. o Ueg-Value for the Cardinal 6mm LoE366-6.CIG-i89-6.CIG assembly is 0.379 ஻்௎ ௛௥∙௙௧ మ ∙°ி  The U-Values for the frame type, vertical orientation were provided by ASHRAE Table 1, page 15.6 as a data for extrapolation was not available. o Uf-Value for wood frame with thermal break is 0 .480 ஻்௎ ௛௥∙௙௧మ∙°ி 6/21/23 Signature (Rader Engineering, Inc.) Date: Appendix I Page 1 of 1 Job Name: 1265 Red Butte Job #: 23018 Date: 06/21/2023 Calcs By: B.G.K. Assembly Window Assembly Fixed Cardinal 6MM Double 366-Clear-i89 2 81 107 17,334 68 95 12888 0.224 1335 0.379 3,112 0.480 0.28 120 0.28 1. Rader Engineering Inc. Disclaimer: The above U-Factors were determined using the methods in the 2017 ASHRAE Handbook, values are calculated estimates. The above window was NOT formally tested by the NFRC. U-Value UT Assembly Area (ft.2)Calculated Assembly Area Weighted U-Value Width (in.) Height (in.) Area ACG (in.2) U-Value UCG Area AEG (in.2) U-Value UEG Unit ID Assembly Type Nom. W (in.) Nom. H (in.) Area AT (in.2) Edge of Glass TOT Frame TOT Area AF (in.2) U-Value UF ASHRAE Fenestration Performance Calculations (Refer to Chpt. 15 of 2021 Fundamentals ASHRAE handbook) Assembly PANEL TOT Center of Glass TOT QTY OF PANELS