Loading...
HomeMy WebLinkAboutFile Documents.1265 Red Butte Dr.0072-2023-BCHO (8)1265 Red Butte_BuildingComment1_Markup Summary Subject: PlanCheck Page Label: 1 Author: linzhid Color: File Name: 90. 1265 Red Butte_Plans_STAMPED.pdf Window spec sheets do not meet U-factor 0.28 requirement because it only provides the U-factor of the glass. Please provide new spec sheet of entire window assembly that has a U-factor of 0.28 or better. 90. 1265 Red Butte_Plans_STAMPED.pdf (2) Subject: PlanCheck Page Label: 3 Author: linzhid Color: File Name: 90. 1265 Red Butte_Plans_STAMPED.pdf Provide new detail to meet prescriptive table per 2015 IECC 402.1.2 stating R-49 insulation requirement for ceilings Window spec sheets do not meet U-factor 0.28 requirement because it only provides the U-factor of the glass. Please provide new spec sheet of entire window assembly that has a U-factor of 0.28 or better. Provide new detail to meet prescriptive table per 2015 IECC 402.1.2 stating R-49 insulation requirement for ceilings