Loading...
HomeMy WebLinkAboutFile Documents.701 Gibson Ave.0086-2021-BRES (32)Job# & Name:1401-21-CE 701 Gibson Date:08/17/2021 By:Luke Vickerman DATE SENT APPROVED Tag QT Manufacturer Model #Location Description Power V-PH-MAX FUSE Access Req Ordered Received On Site CU-1 1 Carrier 38MARBQ24AA3 Outside on North East of Building Serves FC-1 208/230-1-35 N FC-1 1 Carrier 40MBAAQ24XA3 Display Closet Serves Main Living 208/230-1 Y CU-2 1 Toshiba/Carrier MCY-MAP0607HS-UL Outside on North East of Building Serves FC-2,3,4,5,6 208/230-1-40 N FC-2 1 Toshiba/Carrier MMD-AP0096BHPUL Above Lavatory Room Serves Submaster 208/230-1-15 Y FC-3 1 Toshiba/Carrier MMD-AP0096BHPUL Northeast Attic Serves Bed 3 208/230-1-15 Y FC-4 1 Toshiba/Carrier MMD-AP0096BHPUL Southeast Attic Serves Craft Room 208/230-1-15 Y FC-5 1 Toshiba/Carrier MMD-AP0126BHPUL Southeast Attic Serves Master/Office 208/230-1-15 Y FC-6 1 Toshiba/Carrier MMD-AP0186BHPUL Northwest Crawlspace Serves Lower Level 208/230-1-15 Y HUM-1 4 Carrier HUMCRSTM3134 Ref. Plans Humidifier 208-1 Y HWC 1 Coil Company 4B-102-20"x20"-QBS Mounted on FC-1 Serves FC-1 -Y GRD 14 Dayus DABLRJ Ref. Plans Mud in Grille -N Outdoor Unit Single Zone Heat Pump Ductless System Outdoor Model: Job Data:Location: Buyer:Buyer P.O. #:Carrier #: Unit Number: Model Number: Date: NOTE: Images for illustration purposes only. Actual models may be slightly different. 24 Face Area Sq. Ft.8.2 38MARBQ24AA3 2 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 20 MCA A.25 4 Recommended Fuse Size A.30 Rotary Inverter MOCP - Fuse Rating A.35 KTM240D43UKT Cooling Outdoor DB Min - Max °F(°C)-22~122 (-30~50)VG74 Heating Outdoor DB Min - Max °F(°C)-22~86 (-30~30)Oil Charge Fl. Oz.21.0 Total Piping Length ft (m)164 (50)Rated Current RLA 14.8 Piping Lift*ft (m)82 (25)Unit Width in (mm)37.24 (946) Pipe Connection Size - Liquid in (mm)3/8 (9.52)Unit Height in (mm)31.89 (810) Pipe Connection Size - Suction in (mm)5/8 (16)Unit Depth in (mm)16.14 (410) R410A Net Weight lbs (kg)134.48 (61) EEV Airflow CFM 2,235 Charge lbs (kg)5.73 (2.6)Sound Pressure dB(A)62.0 * Condensing unit above or below indoor unit See compatibility chart for additional model specific information Model Oil Type OutdoorRefrigerant Type System Size Outdoor CoilOutdoor Model No. Rows Fins per inch Circuits Compressor TypeElectrical Operating Range Piping Refrigerant Metering Device Performance Data Certified By: STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto-Restart function • Condenser High Temp Protection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Anti-corrosive fin coating LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. 38MARBQ24AA3 Submittal Data Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2021 Page 1 Catalog No: 38MARB-24-3-03SB Replaces: 38MARB-24-3-02SB CU-1 Performance Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W W/W 7,500~26,000 SEER 20.0 COP (5°F)1.75 HSPF 11.6 COP (47°F)3.77 COP (17°F)2.60 Heating Maximum Capacity (17°F)25000 Heating Maximum Capacity (5°F)22000 Heating Cap. Range Min - Max 5,600~31,000 26,661 Heating Maximum Capacity (5°F)24,100 Heating Cap. Range Min - Max 12,500~30,500 COP (5°F)1.76 Ai r H a n d l e r Indoor Model 24K (208/230V) Energy Star YES EER 12.5 Heating Rated Capacity (47°F)27000 Heating Rated Capacity (17°F)16500 Cooling Rated Capacity 22000 Cooling Cap. Range Min - Max 20.2 EER 11.5 Heating Rated Capacity (47°F)24,600 Heating Rated Capacity (17°F)15,240 Co n s o l e Indoor Model 24K (208/230V) Energy Star NO Cooling Rated Capacity 24,000 Cooling Cap. Range Min - Max 9,000~26,800 SEER HSPF 11.6 COP (47°F)3.52 COP (17°F)2.70 Heating Maximum Capacity (17°F) COP (47°F)3.66 COP (17°F)2.80 COP (5°F)2.01 Heating Maximum Capacity (5°F)24,600 Heating Cap. Range Min - Max 12,200~32,200 HSPF 12.6 COP (17°F)2.70 COP (5°F)1.75 Du c t e d Indoor Model 24K (208/230V) Energy Star YES Cooling Rated Capacity Ca s s e t t e Heating Rated Capacity (47°F)24,600 Heating Rated Capacity (17°F)16,500 Heating Maximum Capacity (17°F)26,500 24,000 Cooling Cap. Range Min - Max 6,500~27,800 SEER 20.6 EER 12.5 Heating Cap. Range Min - Max 11,840~27,000 HSPF 11.6 COP (47°F)3.50 Heating Rated Capacity (17°F)15,100 Heating Maximum Capacity (17°F)24,200 Heating Maximum Capacity (5°F)24,100 Heating Rated Capacity (47°F)24,000 COP (5°F)1.75 Indoor Model 24K (208/230V) Energy Star NO Cooling Rated Capacity 24,000 Cooling Cap. Range Min - Max 24,480 Heating Maximum Capacity (5°F)25,400 Heating Cap. Range Min - Max 8,600~31,000 8,000~25,000 SEER 20.0 EER 11 21.5 EER 13 Heating Rated Capacity (47°F)29,000 Heating Rated Capacity (17°F)19,800 Hi g h W a l l Indoor Model 24K (208/230V) Energy Star YES Cooling Rated Capacity 24,000 Cooling Cap. Range Min - Max 6,850~27,000 SEER HSPF 12.0 COP (47°F)3.40 COP (17°F)3.05 Heating Maximum Capacity (17°F) Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2021 Page 2 Catalog No: 38MARB-24-3-03SB Replaces: 38MARB-24-3-02SB Performance Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W Btu/h Btu/h Btu/h Btu/h Btu/h W/W W/W to facilitate piping installation when removing the TXV kit from the indoor unit. HSPF 10.0 COP (47°F)3.42 COP (17°F)2.28 Applications with the FB4CNP, FMA4, FX4D, FV4C, FMC and FMU fan coils require the 24V Interface (2nd Generation) KSAIC0301230 and a Piping Adapter Kit HSPF 11.0 COP (47°F)3.85 COP (17°F)2.80 FM C - F M U F a n C o i l Indoor Model FM(C,U)4Z24**AL* Energy Star NO Cooling Rated Capacity 22,000 Cooling Cap. Range Min - Max 11500~26900 SEER 15.5 EER 12.0 Heating Rated Capacity (47°F)26,200 Heating Rated Capacity (17°F)16,100 Heating Cap. Range Min - Max 10.5 COP (47°F)3.72 COP (17°F)2.64 11800~28600 FV 4 C F a n C o i l Indoor Model FV4CNF002L Energy Star NO Cooling Rated Capacity 22,200 Cooling Cap. Range Min - Max 11100~26400 SEER 14.9 EER 11.4 Heating Rated Capacity (47°F)24,400 Heating Rated Capacity (17°F)15,200 Heating Cap. Range Min - Max 11900~28600 COP (47°F)3.54 COP (17°F)2.40 FX 4 D F a n C o i l Indoor Model FX4DNF025L Energy Star NO Cooling Rated Capacity 22,200 Cooling Cap. Range Min - Max 11400~27100 SEER 15.5 EER 12.1 Heating Rated Capacity (47°F)25,400 Heating Rated Capacity (17°F)15,500 Heating Cap. Range Min - Max 11700~27700 HSPF 3.34 COP (17°F)2.28 FM A 4 X F a n C o i l Indoor Model FMA4X24**AL* Energy Star NO Cooling Rated Capacity 22,000 Cooling Cap. Range Min - Max 11400~26900 SEER 15.0 EER 11.8 Heating Rated Capacity (47°F)26,200 Heating Rated Capacity (17°F)16,000 Heating Cap. Range Min - Max 11900~28600 HSPF 10.0 FB 4 C F a n C o i l Indoor Model FB4CNF024L Indoor Model 2 FB4CNP024L Energy Star NO Cooling Rated Capacity 21,600 Cooling Cap. Range Min - Max 11100~26400 SEER 15.5 EER 11.7 Heating Rated Capacity (47°F)26,200 Heating Rated Capacity (17°F)16,100 Heating Cap. Range Min - Max 11900~28600 HSPF 9.5 COP (47°F) Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2021 Page 3 Catalog No: 38MARB-24-3-03SB Replaces: 38MARB-24-3-02SB Construction View Outdoor Model:38MARBQ24AA3 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2021 Page 4 Catalog No: 38MARB-24-3-03SB Replaces: 38MARB-24-3-02SB Copyright 2020 CAC/BDP ● 3300 Riverwood Parkway, Atlanta, GA 30144 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2020 Page 1 Catalog No: 40MBAA-24-3-01SB Replaces: NEW Air Handler Heat Pump Ductless System Indoor Model: Job Data:Location: Buyer:Buyer P.O. #:Carrier #: Unit Number:Model Number: Date: 24 Face Area Sq. Ft.1.69 40MBAAQ24XA3 2 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 20 Power Supply 4 MCA A.5 Unit Width in (mm)19.6 (498) Standard Unit Height in (mm)48.8 (1,240) Standard Unit Depth in (mm)21.0 (533) Cooling Indoor DB Min -Max ° F (° C)62~90 (17~32)Net Weight lbs (kg)141.1 (64) Heating Indoor DB Min -Max ° F (° C)32~86 (0~30)4 Pipe Connection Size - Liquid in (mm)3/8 (9.52)Airflow (lowest to highest)CFM 588/765/882 Pipe Connection Size - Suction in (mm)5/8 (16)Sound Pressure (lowest to highest)dB(A)37.2/40.4/43/45.2 Max Static Pressure In.WG.0.8 For Compatibility See Product Data Field Drain Pipe Size O.D.in (mm)3/4 (19.1) Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data. Accessories Controls Wireless Remote Controller (°F/°C Convertible) Wired Remote Controller (°F/°C Convertible) Operating Range Number of Fan Speeds Piping EHKMA05KN EHKMA10KN Electric Heater 5kW Electric Heater 10kW System Size Indoor CoilIndoor Model No. Rows Electrical Fins per inch Indoor unit powered from outdoor unit Circuits Indoor STANDARD FEATURES Modes: Cool, Heat, Dry, Fan, Auto 4 way installation (Up flow, Down flow, Right, Left) Static Pressure up to 0.8 inWG Less than 2% air leakage Quiet indoor operation Aluminum Hydrophilic pre-coated fins Controls: Wireless Remote Controller included with indoor unit 24V Interface for third party thermostat compatibility built-in LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. 40MBAAQ24XA3 Submittal Data Performance Data Certified By: FC-1 Copyright 2020 CAC/BDP ● 3300 Riverwood Parkway, Atlanta, GA 30144 SUBJECT TO CHANGE WITHOUT NOTICE Edition Date: 07/2020 Page 2 Catalog No: 40MBAA-24-3-01SB Replaces: NEW Construction View R ear S id e Vie w Nomi nal F ilt er Size 20 x 1 6 x 1 i nches (515 x 442 x 25 mm) /AIUl:II A (H eight ) --•• CERT IFIED ,. C -W/l.h rll!l,,:~111 \'•'HQ --------- in mm 1.; o li! f)" S ll>' II Hf PHRI 5t..n:larcl 210.'21( ~:~~~U•~(~hor><;,,u.,.._.,.,. 4 8 .1 1 ,222 Top View D DUCT 182 [462] ~--------f1~:;;;;;;;;;;;;;;;;;i:;;;;;;;;;;;;;~:::;ll ~ "" c;j f- t) 5 1----------l-lllll=,::::::::=::::::::=:::~lll.f w 3 .0 (75] 0 .6 (16] +,,;,,_ + 1.2 (30) 2 .2 [55) C W IDTH 19.7 (501] B ottom V i ew 18 .4 [466] B (D e pthi C (W id th) D (Duct ) E (D uct) i n mm in mm i n mm in mm 2 1 .1 5 35 1 9 .7 5 0 1 18 .2 4 6 2 10.3 262 2 .2 [57] Right S ide V iew E 10 .3 [262] 1.7 (44] B D E PTH 2 1.1 (535] D rain D rain Li q uid Con nec t ion C onn ect ion Gas Line L1 L2 Li ne Prima ry drain ~r imary d ra ir U pflow Ho riz ont al in mm i n mm in mm in mm 5 /8 16 3/8 9 .5 3 /4 1 9 .1 3 /4 19.1 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MCY-MAP0607HS-UL_01 Pg 1 1-17 Replaces: NEW Submittal Data Job Data_________________________________ Location_______________________________ Buyer ______________________ Buyer PO # ____________ Carrier # _____________________ Unit Number ________________________Model Number ________________________________ Performance Data Certified By _______________________________Date____________________ SMMS-e VRF Heat Pump Features • 3, 4, and 5-ton single-phase modules available • Modules have inverter-driven twin rotary compressor • 591 ft (180 m) actual total system piping (liquid line) • 328 ft (100 m) actual piping length from outdoor unit to furthest fan coil • Up to 330 ft (100 m) control wiring between outdoor units • Up to 6560 ft (2000 m) control wiring between the outdoor units and indoor units • Operating temperature range Cooling (db): 23 to 122 F (–5 to 50 C) • Heating (wb): –13 to 60 F (–25 to 15.6 C) • Protection: high pressure sensor and switch, low pressure sensor, process controller board fuse, inverter overload protection • 7-year compressor limited warranty, • 5-year parts limited warranty LEGEND Header Unit Model MCY-MAP0607HS-UL PERFORMANCE Nominal Cooling Capacity Btu/h 60,000 Nominal Heating Capacity Btu/h 66,000 Maximum Total Connected Indoor Unit Capacity Up to 135% COOLING EFFICIENCY† SEER, Ducted FCUs Btu/Wh 17.60 SEER, Ductless FCUs Btu/Wh 20.50 HEATING EFFICIENCY† HSPF, Ducted FCUs 11.00 HSPF, Ductless FCUs 11.50 Fan Type (Qty) Propeller (2) Airflow CFM 4850 Combined System Sound Pressure, Cooling/Heating dBA 55.0/58.0 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Minimum Circuit Amps (MCA) A 36.3 Recommended Fuse Size A 40 db —Dry Bulb SEER —Seasonal Energy Efficiency Ratio FCU —Fan Coil Unit HSPF —Heating Seasonal Performance Factor wb —Wet Bulb COMPRESSORS Type (Number)Hermetic Twin Rotary (1) Motor Output kW 3.75 FAN MOTOR Motor Type (Steps) Propeller Fan (2) Motor Output kW 0.10 + 0.10 PHYSICAL DATA Pipe Connection Size - Liquid (High Pressure)in. 3/8 (Flare) Pipe Connection Size - Gas (Low Pressure)in. 3/4 (Flare) Refrigerant R-410A Factory Charge†† lb 14.8 External Finish Munsell 1Y8.5/0.5 Unit Width in. 39.8 Unit Height in. 61.0 Unit Depth in. 14.6 Unit Net Weight lb 311 †Rated per AHRI (Air-Conditioning, Heating and Refrigeration Institute) 1230 Standard. Cooling: Indoor 80°F (27°C) db/67°F (20°C) wb; Outdoor 95°F (35°C) db Heating: Indoor 70°F (21°C) db; Outdoor 47°F (8°C) db/43°F (6°C) wb ††Additional charge required. SSMS-e Single VRF Outdoor Unit MCY-MAP0607HS-UL—Heat Pump CU-2 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MCY-MAP0607HS-UL_01 Pg 2 1-17 Replaces: NEW © Carrier Corporation 2017 OUTDOOR UNIT HEAT PUMP MCY-MAP0607HS-UL DIMENSIONAL DRAWING Mo u n t i n g b o l t h o l e De t a i l s o f B l e g s Mo u n t i n g b o l t h o l e De t a i l s o f A l e g s 15.4” (391) Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MMD-AP0096BHPUL_01 Pg 1 01-21 Replaces: New Submittal Data Job Name ________________________________ Location _______________________________ Tag ________________________ INDOOR UNIT MODEL MMD-AP0096BHPUL PERFORMANCE Cooling Rated Capacity Btu/h 9,500 Heating Rated Capacity Btu/h 10,500 Fan Type (Qty)Centrifugal (1) External Static Pressure (ESP)in. WG 0.4 (Factory default) 0.6 (Max) Standard Airflow (H / M / L)CFM 395 / 329 / 263 Sound Pressure (H / M / L)*dBA 41 / 36 / 32 FILTER (Standard) Type Washable Quantity 1 MERV Corresponding Value 5 Dimensions (W x L x D)in.10-5/8 x 27-5/8 x 5/8 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Power Consumption (Input)kW 0.09 Full Load Amps (FLA)A 0.88 Minimum Circuit Amps (MCA)A 1.10 Maximum Overcurrent Protection (MOCP)A 15.0 MOTOR Motor Type DC Motor Watts 150 PHYSICAL DATA Pipe Connection Size - Liquid in.1/4 (Flare) Pipe Connection Size - Suction in.3/8 (Flare) Pipe Connection Size - Drain (OD)in.1-1/4 Pipe Connection Size - Drain (ID)in.1 Refrigerant R-410A External Finish Zinc Hot Dipped Steel Plate Unit Width in.27-5/8 Unit Height in.10-7/8 Unit Depth in.29-5/8 Net Weight lb 56 SMMSe / SHRMe CONCEALED DUCT FEATURES • R-410A Refrigerant • Twelve sizes from 7,500 to 54,000 Btu/h • Standard condensate pump with 24.3 in. lift capability • Quiet operation, as low as 30 dBA • Rear return configurable for bottom return • Auto or manually set three fan speeds • Five-year parts limited warranty ACCESSORIES Wired Remote Controller (7-Day Programmable) RBC-AMS54E-UL  Simple Wired Remote Control RBC-AS41UL  Stand-Alone Receiver with Wireless Remote TCB-AX32UL  Remote Sensor TCB-TC41LUL Wired Remote Controller - RBC-AMT32UL Auxiliary OA Flange TCB-FF151US-UL Zoning Duct Flange TCB-SF56C6BP-UL * The actual values in an external operating environment are generally higher than the indicated values due to ambient noise. SMMSe / SHRMe VRF Indoor UnitMMD-AP0096BHPUL—Concealed Duct FC-2,3,4 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MMD-AP0096BHPUL_01 Pg 2 01-21 Replaces: New © Carrier Corporation 2021 DIMENSIONAL DRAWING CONCEALED DUCT MMD-AP0096BHPUL Hanging bolt pitch 30-1/8 25-1/4(Outside) Unit external dimension 27-5/8 2- 1 / 2 7- 1 / 8 ( O u t s i d e ) 10 - 7 / 8 Un i t e x t e r n a l d i m e n s i o n Flexible drain hose (Accessory) 1/100 or more downward At the time of natural drainage 1/100 or more downward Flexible drain hose 11-3/4 (Accessory) or less 24 - 3 / 8 33 - 1 / 2 o r l e s s or l e s s 6- 3 / 4 5-3/8 Drain-up piping Ø 4-7/8 knockout hole (For fresh air intake) 2 2 Electrical control box 25 - 5 / 8 22 - 1 / 2 14 Ha n g i n g b o l t p i t c h 2 5 - 5 / 8 4-1/4 3/4 1-1/2 9-1/8 9-1/8 13 - 5 / 8 Un i t e x t e r n a l d i m e n s i o n 2 9 - 5 / 8 Air filter 25-3/4 9 Refrigerant pipe connecting port Ø1/4 (Liquid side) connecting port Ø3/8 Refrigerant pipe (Gas side) connecting port 9- 1 / 8 3/ 4 Drain pipe 3/4 26 9- 1 / 4 3-7/83-1/2 26-58 10 3- 7 / 8 1- 1 / 8 26 9- 1 / 4 1-1/5 10 1- 1 / 8 Air discharge Ceiling 3-7/8 or more 1 29-1/2 98 - 3 / 8 o r mo r e Floor surface 27-1/2 or more Inspection opening (Ceiling opening) 1/ 4 o r mo r e 2- 3 / 4 o r mo r e 10 - 7 / 8 Ceiling Air intake 1 2 or more 22-1/2 3-7/8 or more Inspection opening (Ceiling opening) 4- 3 / 4 Air discharge 17-3/4 Check port 27-1/2 Service space Ceiling 1 Air intake (for maintenance of air filter) Ceiling Air intake Inspection opening (Ceiling opening) 22-1/2 1 Inspection opening (Ceiling opening) 7/ 8 11-3/4 or more 4- 5 / 8 3/ 4 1- 1 / 8 3- 7 / 8 3-7/8 3-7/8 3-7/8 3-7/8 3-1/2 1-1/5 1- 1 / 8 3- 7 / 8 3-7/8 3- 7 / 8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 1 22-1/2 Bo t t o m V i e w All dimensions are shown in inches. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MMD-AP0126BHPUL_01 Pg 1 01-21 Replaces: New Submittal Data Job Name ________________________________ Location _______________________________ Tag ________________________ INDOOR UNIT MODEL MMD-AP0126BHPUL PERFORMANCE Cooling Rated Capacity Btu/h 12,000 Heating Rated Capacity Btu/h 13,500 Fan Type (Qty)Centrifugal (1) External Static Pressure (ESP)in. WG 0.4 (Factory default) 0.6 (Max) Standard Airflow (H / M / L)CFM 395 / 329 / 263 Sound Pressure (H / M / L)*dBA 41 / 36 / 32 FILTER (Standard) Type Washable Quantity 1 MERV Corresponding Value 5 Dimensions (W x L x D)in.10-5/8 x 27-5/8 x 5/8 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Power Consumption (Input)kW 0.09 Full Load Amps (FLA)A 0.88 Minimum Circuit Amps (MCA)A 1.10 Maximum Overcurrent Protection (MOCP)A 15.0 MOTOR Motor Type DC Inverter Driven Motor Watts 150 PHYSICAL DATA Pipe Connection Size - Liquid in.1/4 (Flare) Pipe Connection Size - Suction in.3/8 (Flare) Pipe Connection Size - Drain (OD)in.1-1/4 Pipe Connection Size - Drain (ID)in.1 Refrigerant R-410A External Finish Zinc Hot Dipped Steel Plate Unit Width in.27-5/8 Unit Height in.10-7/8 Unit Depth in.29-5/8 Net Weight lb 56 SMMSe / SHRMe CONCEALED DUCT FEATURES • R-410A Refrigerant • Twelve sizes from 7,500 to 54,000 Btu/h • Standard condensate pump with 24.3 in. lift capability • Quiet operation, as low as 30 dBA • Rear return configurable for bottom return • Auto or manually set three fan speeds • Five-year parts limited warranty ACCESSORIES Wired Remote Controller (7-Day Programmable) RBC-AMS54E-UL  Simple Wired Remote Control RBC-AS41UL  Stand-Alone Receiver with Wireless Remote TCB-AX32UL  Remote Sensor TCB-TC41LUL Wired Remote Controller - RBC-AMT32UL Auxiliary OA Flange TCB-FF151US-UL Zoning Duct Flange TCB-SF56C6BP-UL * The actual values in an external operating environment are generally higher than the indicated values due to ambient noise. SMMSe / SHRMe VRF Indoor UnitMMD-AP0126BHPUL—Concealed Duct FC-5 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MMD-AP0126BHPUL_01 Pg 2 01-21 Replaces: New © Carrier Corporation 2021 DIMENSIONAL DRAWING CONCEALED DUCT MMD-AP0126BHPUL Hanging bolt pitch 30-1/8 25-1/4(Outside) Unit external dimension 27-5/8 2- 1 / 2 7- 1 / 8 ( O u t s i d e ) 10 - 7 / 8 Un i t e x t e r n a l d i m e n s i o n Flexible drain hose (Accessory) 1/100 or more downward At the time of natural drainage 1/100 or more downward Flexible drain hose 11-3/4 (Accessory) or less 24 - 3 / 8 33 - 1 / 2 o r l e s s or l e s s 6- 3 / 4 5-3/8 Drain-up piping Ø 4-7/8 knockout hole (For fresh air intake) 2 2 Electrical control box 25 - 5 / 8 22 - 1 / 2 14 Ha n g i n g b o l t p i t c h 2 5 - 5 / 8 4-1/4 3/4 1-1/2 9-1/8 9-1/8 13 - 5 / 8 Un i t e x t e r n a l d i m e n s i o n 2 9 - 5 / 8 Air filter 25-3/4 9 Refrigerant pipe connecting port Ø1/4 (Liquid side) connecting port Ø3/8 Refrigerant pipe (Gas side) connecting port 9- 1 / 8 3/ 4 Drain pipe 3/4 26 9- 1 / 4 3-7/83-1/2 26-58 10 3- 7 / 8 1- 1 / 8 26 9- 1 / 4 1-1/5 10 1- 1 / 8 Air discharge Ceiling 3-7/8 or more 1 29-1/2 98 - 3 / 8 o r mo r e Floor surface 27-1/2 or more Inspection opening (Ceiling opening) 1/ 4 o r mo r e 2- 3 / 4 o r mo r e 10 - 7 / 8 Ceiling Air intake 1 2 or more 22-1/2 3-7/8 or more Inspection opening (Ceiling opening) 4- 3 / 4 Air discharge 17-3/4 Check port 27-1/2 Service space Ceiling 1 Air intake (for maintenance of air filter) Ceiling Air intake Inspection opening (Ceiling opening) 22-1/2 1 Inspection opening (Ceiling opening) 7/ 8 11-3/4 or more 4- 5 / 8 3/ 4 1- 1 / 8 3- 7 / 8 3-7/8 3-7/8 3-7/8 3-7/8 3-1/2 1-1/5 1- 1 / 8 3- 7 / 8 3-7/8 3- 7 / 8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 1 22-1/2 Bo t t o m V i e w NOTE: All dimensions shown in inches. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A.Form MMD-AP0186BHPUL_02 Pg 1 03-21 Replaces: MMD-AP0186BHPUL_01 Submittal Data Job Name ________________________________ Location _______________________________ Tag ________________________ INDOOR UNIT MODEL MMD-AP0186BHPUL PERFORMANCE Cooling Rated Capacity Btu/h 18,000 Heating Rated Capacity Btu/h 20,000 Fan Type (Qty)Centrifugal (1) External Static Pressure (ESP)in. WG 0.4 (Factory default) 0.6 (Max) Standard Airflow (H / M / L)CFM 624 / 489 / 394 Sound Pressure (H / M / L)*dBA 45 / 41 / 35 FILTER (Standard) Type Washable Quantity 2 MERV Corresponding Value 5 Dimensions (W x L x D)in.10-5/8 x 19-5/8 x 5/8 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Power Consumption (Input)kW 0.14 Full Load Amps (FLA)A 1.53 Minimum Circuit Amps (MCA)A 1.91 Maximum Overcurrent Protection (MOCP)A 15.0 MOTOR Motor Type DC Motor Watts 150 PHYSICAL DATA Pipe Connection Size - Liquid in.3/8 (Flare) Pipe Connection Size - Suction in.5/8 (Flare) Pipe Connection Size - Drain (OD)in.1-1/4 Pipe Connection Size - Drain (ID)in.1 Refrigerant R-410A External Finish Zinc Hot Dipped Steel Plate Unit Width in.39-3/8 Unit Height in.10-7/8 Unit Depth in.29-5/8 Net Weight lb 73 SMMSe / SHRMe CONCEALED DUCT FEATURES • R-410A Refrigerant • Twelve sizes from 7,500 to 54,000 Btu/h • Standard condensate pump with 24.3 in. lift capability • Quiet operation, as low as 30 dBA • Rear return configurable for bottom return • Auto or manually set three fan speeds • Five-year parts limited warranty ACCESSORIES Wired Remote Controller (7-Day Programmable) RBC-AMS54E-UL  Simple Wired Remote Control RBC-AS41UL  Stand-Alone Receiver with Wireless Remote TCB-AX32UL  Remote Sensor TCB-TC41LUL Wired Remote Controller - RBC-AMT32UL Auxiliary OA Flange TCB-FF151US-UL Zoning Duct Flange TCB-SF80C6BP-UL * The actual values in an external operating environment are generally higher than the indicated values due to ambient noise. SMMSe / SHRMe VRF Indoor UnitMMD-AP0186BHPUL—Concealed Duct FC-6 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form MMD-AP0186BHPUL_02 Pg 2 03-21 Replaces: MMD-AP0186BHPUL_01 © Carrier Corporation 2021 DIMENSIONAL DRAWING CONCEALED DUCT MMD-AP0186BHPUL Air discharge Ceiling 3-7/8 or more 1 41-3/8 99 - 3 / 8 o r mo r e Floor surface 27-1/2 or more 1 Inspection opening (Ceiling opening) 1/ 4 o r mo r e 2- 3 / 4 o r mo r e 10 - 7 / 8 Ceiling Air intake 1 2 or more 22-1/2 3-7/8 or more Inspection opening (Ceiling opening) 4- 3 / 4 Air discharge 17-3/4 Check port 19-5/8 Service space Ceiling 1 Air intake (for maintenance of air filter) 22-1/2 Ceiling Air intake Inspection opening (Ceiling opening) 1 Inspection opening (Ceiling opening) 11-3/4 or more 2- 1 / 2 7- 1 / 8 ( O u t s i d e ) 10 - 7 / 8 Un i t e x t e r n a l d i m e n s i o n Hanging bolt pitch 41-7/8 Unit external dimension 39-3/8 37(Outside) Flexible drain hose (Accessory) 1/100 or more downward 24 - 3 / 8 At the time of natural drainage or l e s s 1/100 or more downward 11-3/4 Flexible drain hose (Accessory) or less 33 - 1 / 2 o r l e s s 6- 3 / 4 5-3/8 Drain-up piping Refrigerant pipe Ø4-7/8 knockout hole (For fresh air intake) connecting port Ø3/8 (Liquid side) connecting port Ø5/8 Refrigerant pipe 4-1/4 (Gas side) connecting port 25 - 5 / 8 Drain pipe 22 - 1 / 2 14 3/4 1-1/2 9-1/8 9-1/8 13 - 5 / 8 9- 1 / 8 3/ 4 3/4 37-1/2 9 Air filter 37-3/4 9- 1 / 4 3-7/81-1/2 1- 1 / 8 10 38-3/8 3-7/81-1/2 9- 1 / 4 1- 1 / 8 10 10-1/4 Un i t e x t e r n a l d i m e n s i o n 2 9 - 5 / 8 3/ 4 22 7/ 8 Ha n g i n g b o l t p i t c h 2 5 - 5 / 8 Electrical control box 1- 1 / 8 1-1/23-7/8 3-7/83-7/83-7/83-7/8 3-7/83-7/83-7/8 1- 1 / 8 1-1/23-7/8 3-7/8 3-7/83-7/83-7/83-7/83-7/8 3-7/8 22-1/2 3- 7 / 8 3- 7 / 8 3- 7 / 8 3- 7 / 8 Bo t t o m V i e w All dimensions are shown in inches. Product Data HUMCR Humidifiers A14603B Controlling indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the culprit for such common problems as itchy or cracked skin, eye irritation, dry nasal passages, and damaged home furnishings. Dry indoor air can also increase the possibility of catching cold and flu viruses and can reduce the efficiency and effectiveness of the heating system. All of these problems can be alleviated with the help of a Carrier humidifier. Carrier offers six humidifier models designed to put moisture back into the indoor environment so homeowners can relax in warm, soothing comfort. Depending on the model that best matches the system, a Carrier humidifier can deliver between 12 and 34 gallons (45 and 129 liters) of moisture per day to minimize the problems of excessively dry air. And, because humidified air feels warmer, using lower thermostat settings may be possible for added energy savings. FEATURES/BENEFITS (Bypass & Fan Powered Models) Easy Access for Cleaning and Maintenance—The treated aluminum water panel (or wicking paper water panel in the water-saver model) ensures top performance. Front or side access door allows for quick and convenient removal and replacement of water panel. Smooth, Low-Noise Operation—Nearly silent operation is the result of Carrier humidifier’s precision-engineered fan and motor combination on fan powered models. Air is drawn through the water panel quietly and efficiently, turning water into the water vapor that humidifies the home. Long Lasting, Attractive Cover—The outside casing and interior components of all Carrier humidifiers are made from durable UV resistant plastic. This plastic resists deterioration, even when exposed to ultra-violet light sources common in many systems. Built-In Bypass Damper—On the LBP, SBP and WBP models. Optimum Distribution of Moisture—Through the combination of the solenoid valve and water distribution system by Carrier, homeowners will benefit from the most optimum distribution of moisture possible. Four Humidity Control Options—Choose between four separate control options, the Humidistat, the HumidiTract,the Thermidistatt, and the Infinitysystem Control. Each of these units provide precise control over the humidity levels in the home. Granite Gray—Color-compatible with most HVAC equipment. Water Saver Models -WBP Series units deliver 100% of water used. For use in applications where water costs are high, with septic systems or in drought-stricken areas HUM-1 2 FEATURES/BENEFITS (Steam Model) The steam humidifier delivers humidity in the form of steam to the conditioned space via the HVAC system duct. Unlike older steam humidifiers using electric heating elements, this device generates steam by energizing two electrodes that extend into a canister of water. Current flowing between the electrodes causes the water to boil, creating steam, which is delivered into the air stream through a dispersion tube mounted in the ductwork. Openings in the dispersion tube are fitted with “tubelets” which extend into the center of the tube. The design of the dispersion tube and tubelets distribute steam over a wide area in the duct and direct any condensed moisture back into the steam hose. S Steam is generated via electrodes in replaceable canister S Canistercan bereplaced easily and quickly - no cleaning required S Capable of operating with either 115 or 208-240 voltage S Unit can be mounted on wall, duct or indoor unit S Dispersion technology prevents condensation in duct S Water filtration not required - suitable for a wide range of water conditions S Granite gray color, compatible with most HVAC equipment S Includes: manual control, 6-ft steam hose, dispersion tube, 10-ft drain tubing, hose clamps, saddle valve MODEL NUMBER NOMENCLATURE HUM CR LFP 15 18 Product Type Gallons (Liters) Per Day HUM = Humidifier LFP = 18 (68) SBP = 12 (45) LBP = 17 (64) WBP = 17 (64) Brand - Carrier STM = 34 (129) Model Type LFP = Large Fan Powered SBP = Small Bypass Series LBP = Large Bypass 15 = LFP WBP = Water Saving Large Bypass 24 = SBP, LBP, WBP STM = Steam 31 = STM 3 PHYSICAL DATA MODEL HUMCRLFP HUMCRLBP HUMCRWBP HUMCRSBP HUMCRSTM Output Gallons (Liters)/Day 18 (68) 17 (64) 12 (45) 34** (128**) TYPE Airflow Fan Bypass N/A Water Flow Drain Through Sump with Overflow Drain Drain Through Steam GENERAL Water Panel Replacement P110- 3545 (10 packs) P110- 3545 (10 packs) P110- 4545 (5 - 2 packs) P110- 1045 (10 packs) N/A Water Panel in (mm) (HxWxD) 13 x 10 x 1- 11/16 (330 x 254 x43) 9- 7/8x9- 5/8x 1- 11/16 (251 x 244 x 43) N/A Water Panel Access Quick Release Cover N/A Unit Size in (mm) (HxWxD) 18 x 16 x 10- 1/4 (457 x 406 x 260) 15- 1/8 x 14 x 10- 1/4 (384 x 356 x 260) 12- 1/4 x 14 x 10- 1/4 (311 x 356 x 260) 21x9x7-1/4 (533 x 229 x 184) Weight lbs (kg)17.1 (7.8)8.0 (4)7.0 (3)23 (10) Water Usage Gal (liters)/hr) 6 (23)3 (11)1.44** (5.45**) ELECTRICAL CONTROL LOW- VOLTAGE SOLENOID Volts 24V- 60Hz N/A Amps (Max)0.5 N/A VA (Max)12 N/A Watts 2.3 N/A HIGH VOLTAGE CORD Volts 120V- 1ph- 60Hz N/A 120V- 1ph- 60Hz 208V- 1ph- 60Hz 240V- 1ph- 60Hz Amps 0.7 N/A 11.5 - 16 (nominal) CONNECTIONS Water Inlet 1/4- in. Copper Tubing Water Drain 1/2-in.I.D.plastichose 7/8 -in.Tube Bypass Opening N/A 6- in. round elbow or straight N/A Duct Opening in (mm) (W x H) 14- 13/16 x 14- 1/4 (376 x 362) 9- 7/8 x 12- 5/8 (251 x 321) 9- 1/2x9- 1/2 (241 x 241) 1- 1/4- inRound (32) STANDARD EQUIPMENT Water Valve Solenoid, 24VAC Motor Thermal Protected 120VAC (0.014HP = 1/70 HP) N/A N/A Relay SPST 24VAC N/A DPST 24VAC Humidistat 24V 24V (not included) 24V Saddle Valve Standard Damper N/A Standard N/A Template Installation Sheet Included N/A ACESSORIES HumidiTract Automatic Cntrl KUAW0101CAC- A10 Blower Activation Relay 5387 **Varies by voltage and amperage. 4 DIMENSIONS 10.25 (260) 14.0 (356) 15.75 (400) 5.68 (144) Damper "Season" Selector Built-In Bypass Damper Built-In Bypass Damper 10.25 (260) 13.0 (330) 5.68 (144) DUCT CUT-OUT SIZE W x H 9.88 x 12.75 (251 x 324) DUCT CUT-OUT SIZE W x H 9.50 x 9.50 (241 x 241) Model HUMCRLBP2417 & HUMCRWBP2417 Model HUMCRSBP2412 10.25 (260) 16.0 (406) 18.0 (457) DUCT CUT-OUT SIZE W x H 14.81 x 14.25 (376 x 362) Model HUMCRLFP1518 SUMMER SUMMER WI N T E R 14.0 (356) Damper "Season" Selector SUMMER SUMMER WI N T E R A14598A 5 DIMENSIONS (cont.) 10 1/8" 20 7/8" FRONT VIEW 3 3/8" 7 7/8" 8 7/8" 3 3/8" 1 5/8" 4 1/4"5 3/4" Dispersion Outlet Electrical Knockouts Fill Cup TOP VIEW 7 1/8" SIDE VIEW 1" 4" 4" 12" BACK VIEW Mounting Holes 3 3/8" 7 7/8" 2" 3 3/8" Water Fill Line Connection Drain BOTTOM VIEW 3" sq 2" sq 8 1/4" 1" dia STEAM DISPERSION TUBE 3" Mounting Plate to first opening1 3/4" UP Model HUMCRSTM3134 A12460A 6 TYPICAL HUMIDIFIER INSTALLATIONS (Bypass and Fan Powered Models) DOWNFLOW HORIZONTAL Built-in Bypass Damper Built-in Bypass Damper UPFLOW UPFLOW *Note - It is recommended that hot water be supplied in this return air application. * UPFLOW Built-in Bypass Damper A06225 7 TYPICAL HUMIDIFIER INSTALLATIONS (Steam Model) 90° long sweep or two 45° elbows Pitch* Duct Dispersion tubeSteam hose or pipe. Insulate pipe with 1” fiberglass to reduce steam loss. * Pitch steam hose down from dispersion tube to humidifier: 2"/ft (15%) minimum when using steam hose. 1/4"/ft when using hard pipe. Pitch Obstruction 90° long sweep or two 45° elbows 6" min 8" min Insulate hard pipe to reduce steam loss To Dispersion Tube 1" air gap Open drain required, See note 1. Drip tee installation for piping over obstruction, or if dispersion tube is lower than humidifier. NOTES: 1. Refer to governing codes for drain pipe size and materials. 2. Support steam hose so there are no sags or low spots. Drip tee Drain trap Dispersion Tube Mounted Above Humidifier Dispersion Tube Mounted Below Humidifier 16" for Steam Hose 30" for Service Access 16" for Electrical Access4" 16" for Drain FRONT VIEW SIDE VIEW Clearances A12461 Steam Humidifier Capacity Steam Hose or Insulated Pipe Length 120 Volts 208 Volts 240 Volts 11.5 Amps 16.0 Amps 11.5 Amps 16.0 Amps 11.5 Amps 16.0 Amps Steam Hose Insulated Pipe Steam Hose Insulated Pipe Steam Hose Insulated Pipe Steam Hose Insulated Pipe Steam Hose Insulated Pipe Steam Hose Insulated Pipe <2 ft.11.5 11.5 16.0 16.0 20.5 20.5 30.0 30.0 23.3 23.3 34.6 34.6 2ft.11 11 15.5 15.5 20 20 29 29.5 23 23 34 34 4ft.10 11 14.5 15.5 19 20 28 29.5 22 23 33 34 6ft.9 11 13.5 15 18 20 27 29 21 22 32 33 8 STEAM HUMIDIFIER WATER QUALITY CONSIDERATIONS Minerals that are naturally found in water cause the water to be electrically conductive. Water conductivity is measured in micro Siemens per centimeter (uS/cm). Mineral content, also described as “water hardness” is usually measured in grains per gallon. Because of the variety of minerals that are found in water, there is no direct correlation between water hardness and conductivity, but generally the higher the mineral content, the higher the conductivity. The Canister Steam Humidifier is designed to operate on water with conductivity between 125 and 1,250 uS/cm. This correlates loosely with water with hardness between 3 and 36 grains/gallon. Water that is considered “hard” and also softened water work well in the humidifier. The humidifier will make steam when plumbed to low-conductivity water but it takes longer to reach nominal capacity. With low conductivity water, it may take the humidifier one week or more of operation to reach rated capacity, especially if it is wired to operate on 120 volts. When operating on 240 volts, the humidifier usually will reach nominal capacity within a few hours, even with lower conductivity water. As water in the canister boils and turns into steam, minerals are left behind. Minerals remaining in solution increase the conductivity of the water. Minerals also deposit onto the submerged portions of the electrodes rendering those areas ineffective. As this occurs, the level of water in the canister rises to expose un-coated electrode surface. There are benefits and trade-offs to consider when the application allows a choice between hard and softened water: Hard water:The benefit of hard water is less frequent draining and filling than with soft water, which results in better energy and water efficiency and more consistent steam output. However, canister replacement could be more frequent with hard water, because hard water scale coats the electrodes. The harder the water, the more frequent the need for a new canister. Softened water:The benefit of softened water is longer canister life (depending on water chemistry) than with hard water, because softened water does not coat the electrodes nearly as much as hard water. However, softened water ions stay in solution to much higher concentrations than hard water ions. This requires more frequent draining and filling, which results in less energy and water efficiency and less consistent steam output. Conductivity (uS/cm) of water connected to humidifier Estimated grains/gallon (prior to any water softening) Hardness (prior to any water softening) Canister Behavior Solution 0- 125 0- 3 Naturally Soft Humidifier does not function Installation not recommended 125- 300 3- 9 Naturally Soft Long start up time Power with 240VAC, use constant fan to increase time to full capacity 300- 500 9- 15 Slightly Hard Optimal performance range Use hard or softened water500- 640 15- 20 Moderately Hard 640- 840 20- 25 Hard 840- 1250 25- 36 Very Hard Shortened canister life due to scale build up Use softened water above 1250 36 Extremely Hard Canister performance degrades quickly Installation not recommended NOTE: If softened water is not available, or if non- softened water will be used in the humidifier, use this table to estimate the conductivity ofthe water delivered to the humidifier. Then take the appropriate actions as necessary. Using softened water is generally acceptableunless the water is extremely conductive. The conductivity of softened water is usually slightly higher than the conductivity of the hardwater entering the softener. For softened water, use a conductivity test together with the table above if there is a concern that the watermay be too conductive. The manufacturer is not responsible for failures due to misapplication of the product using water that is unsuit-able for this technology. 9 Recommended Relative Humidity by Outdoor Temperature OUTDOOR TEMP _F(_C) OUTDOOR RELATIVE HUMIDITY (%) INDOOR RELATIVE HUMIDITY (%) W/O HUMIDIFIER* MAX RECOMMENDED INDOOR RELATIVE HUMIDITY{ -10(-23)30 to 70 1to2 20 (Lo) 0 (- 18)30 to 70 2to4 25 10 (- 12)30 to 70 3to6 30 20 (- 7)30 to 70 4to10 35 30 (- 1)30 to 70 6to15 40 (Med) *Indoor relative humidity level when outdoor air is heated to 72_F/22_C. {As stipulated by the Air Conditioning Contractors of America. Indoor Relative Humidity Limit for no Window Condensation (Indoor Air at 74_F/23_CDryBulb) OUTDOOR TEMPERATURE _F(_C) SINGLE PANE WINDOWS (%) DOUBLE PANE WINDOWS (%) 40 (4)39 59 30 (- 1)29 50 20 (- 7)21 43 10 (- 12)15 36 0 (- 18)10 30 -10(-23)7 26 -20(-29)5 21 -30(-34)3 17 Maximum Moisture Requirements* VOLUME OF RESIDENCE CUBIC FEET (CUBIC METER) TIGHT HOUSE AVERAGE HOUSE POUNDS (KILOGRAMS) PER HOUR GALLONS (LITERS) PER DAY POUNDS (KILOGRAMS) PER HOUR GALLONS (LITERS) PER DAY 8,000 (227)1.76 (0.8)5.09 (19)3.52 (1.6)10.17 (38) 10,000 (283)2.21 (1.0)6.35 (24)4.41 (2.0)12.72 (48) 12,000 (340)2.64 (1.2)7.63 (29)5.29 (2.4)15.26 (58) 14,000 (396)3.09 (1.4)8.91 (34)5.92 (2.7)17.08 (65) 16,000 (453)3.53 (1.6)10.18 (39)7.06 (3.2)20.35 (77) 18,000 (510)3.97 (1.8)11.45 (43)7.94 (3.6)22.89 (87) 20,000 (566)4.41 (2.0)12.72 (48)8.82 (4.0)25.44 (96) 22,000 (623)4.85 (2.2)13.99 (53)9.71 (4.4)27.98 (106) 24,000 (680)5.29 (2.4)15.27 (58)10.59 (4.8)30.52 (116) 26,000 (736)5.74 (2.6)16.54 (63)11.47 (5.2)33.07 (125) 28,000 (793)6.18 (2.8)17.81 (67)12.35 (5.6)35.61 (135) 30,000 (850)6.62 (3.0)19.08 (72)13.24 (6.0)38.16 (144) *Based on design conditions of outdoor 20_F/- 7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residential operations for an absolute humidity difference of 0.0049 lb/hr. NOTE: Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fire-places. Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace. 10 Humidifier Replacement Water Panels and Canisters DESCRIPTION USED WITH TOTALINEORDERING NO. Replacement Water Panel HUMCRLFP1518 P110- 3545 (10 packs)HUMCRLBP2417 HUMCRSBP2412 P110- 1045 (10 packs) HUMCRWBP2417 P110- 4545 (Five 2 packs) Steam Canister HUMCRSTM3134 8045HUM Blower Activation Relay All Models 5387 Humidifier Accessories DESCRIPTION USED WITH PART NO. HumidiTract Automatic Control HUMCRLFP1518 KUAWC0101CAC- A10 HUMCRLBP2417 HUMCRWBP2417 HUMCRSBP2412 HUMCRSTM3134 Humidistat Manual Control HUMCRWBP2417 4363 (Totaline) Relay HUMCRLFP2417 HN61KQ120 (Totaline) Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. E2019 CAC / BDP Heating & Cooling Systems D 7310 W. Morris St.D Indianapolis, IN 46231 Edition Date: 12/19 Replaces: HUMCR- 01PD Catalog No. HUMCR- 02PD Information Project: Project 210824-2 Date: 8/24/2021 9:32:20 AM Coil Name: 701 Gibson Model #: 4B-102-20" x 20" -QBS Coil ID: 300303 Physical Data Materials Internal Fluid Mode: Heating Coils/Bank: 1 Fin Type: 1/2" 1.25" x 1.083" Waffle Fin Height: 20" Fin Length: 20" Rows: 2 Fins/Inch: 10 Circuiting: Quarter Opp End Connections: No Dry Weight (ea.): 19 Lbs. Turbulators: No Fin Matl: Aluminum 0.0060 in. Tube Matl: Copper 0.016 in. Conn Size: 1 | # Conn: 1 Fluid: PropyleneGlycol 40 % Ent Fluid Temp: 140 °F GPM: 8.50 Airside Construction Airflow: 882.0 ACFM Altitude: 7000 ft. Ent. DB: -20 °F LDB Req'd: 60 °F Coil Hand: Right Casing Matl: 18 Ga Galv Steel Casing Type: Slip And Drive Connection Matl: Copper Connection Type: MPT Performance Description UOM Water Perf. Model 4B-102-20" x 2-" -QBS Rows/FPI fpi 2 / 10.0 Total Capacity MBH 72.3 Sensible Capacity MBH 72.3 Lvg Air DB °F 61.7 Face Velocity ACFM 317.52 Lvg Fluid Temp °F 122.4 Fluid Flow Rate GPM 8.50 Air Pressure Drop in. H2O 0.06 Fluid Pressure Drop Ft. H2O 5.62 Coil Circuiting 4 Feeds Connection Size NPS 1" Fluid Velocity fps 3.65 Dry/Operating Weight (ea.)Lbs 19 / 25 Special Notes: T: (800) 523-7590 | http://www.coilcompany.com/ PO Box 84 | Thornton, PA 19373 EZ-Coil Selection Software Version: 5.0.0.0HWC-1 Top View -------1.A.L.--------3.00" 1.75" .D. 6.00" 5.00" Front View ----------11.A.L.--------3.00" 1.75" C.H.= F.H. + 0.125"F .•.. . 0625" 0.25"-j .L. 0.0625" I . r.L. = F.L. + 0.50"---- H.D. .25" Return Supply Connection Size 3/4" M.P.T. 1.00" M.P.T. 1.25" M.P.T. 1.50" M.P.T. 2.00" DRAIN Side View � ·5.00" .00" 5.50" 5.75" 6.00" 6.25" VENT 2.00" Add to F.L. O.A.L. = F.L. + Add On P.O. Box 84, Thornton, PA 19373 Tubes: .500" x .016" Wall Copper Fins: .006" Thick Aluminum Rows: 2 Casing: 18 Gauge Galvanized Steel Header Material: Type "L" Copper Fasteners: Steel/Steel Rivets Notes: All coils are leak tested under water with 550 PSIG dry Nitrogen. All dimensions are in inches. Headers may exceed the "C.D." 4-S-2-H-M Bar Linear J-Bead Flange Removable Core Grille Phone: (519) 737-1199 Fax: (519) 737-1831 Email: mail@dayus.com Web: www.dayus.com Dayus Register & Grille 5290 Pulleyblank St., RR#1  Windsor, Ontario  N9A 6J3 SUBMITTAL DRAWING  Fully extruded aluminum construction for a stylish built-in look  J-Bead recessed flange frame must be taped & plastered over  Removable core held in place with clips  Fixed blades designed for long straight air throw  Sections longer than 84” are joined together for continuous appearance with the aligning pins provided  Available on 1/2” increments as standard  Custom sizes available, but extra charge may apply  Durable powder coat painted finish  Available in White, Silver, Brown, Mill or Special*  Plaster finishing is the responsibility of the installer •New J-Bead flange frame design for a built-in look TAPER DRYWALL AS REQUIRED ver. 06/17 DABLRJ HOW TO ORDER DABLRJ – 00 – TB 30 x 4 COLOR Mounting A or TB Blade -00,-01,-15 -30,-82,-84 Length & Height Not suitable for floor use Dayus Register & Grille White, Silver Brown, Mill or Special* JOB NAME: ___________________________________________________ LOCATION: ___________________________________________________ ARCHITECT:___________________________________________________ ENGINEER: ___________________________________________________ CONTRACTOR:________________________________________________ MODEL DABLRJ FACE BLADES Horizontal Fixed REAR BLADES n/a DAMPER n/a MATERIAL Aluminum COLOR White/Silver/Mill Brown/Special* Page S103 GRD ver. 06/17 Bar Linear Blade Options SUBMITTAL DRAWING Dayus Register & Grille Phone: (519) 737-1199 Fax: (519) 737-1831 Email: mail@dayus.com Web: www.dayus.com Dayus Register & Grille 5290 Pulleyblank St., RR#1  Windsor, Ontario  N9A 6J3 -01- -00- -30- -15- -84- -82- 0o 13/64” blades on ½” centers 0o 1/4” blades on ½” centers 15o 13/64” blades on ½” centers 30o 13/64” blades on ½” centers 0o 1/8” blades on ¼” centers  Additional charges apply for the -84 core option 0o 1/8” blades on ½” centers ver. 06/17 -B SPRING CLIPS Clips behind the flange keep grille snug in opening and are not visible from the face. Only for floor and sill applications. NOT suitable for wall or ceiling use. -A SCREWS Color matched screws with countersunk screw holes. Suitable for ceiling, wall or sill installation. -D SIDEWALL SCREW HOLES Screw holes drilled at 45o on inner flange. Only available with –R Removable core. (Removable option not available for floor) Suitable for ceiling, wall or sill installation. -C CONCEALED BRACKETS Grille gets fastened to duct-mounted brackets that are concealed behind the blades. Suitable for ceiling, wall or sill installation. -TB NO MOUNTING OPTION For custom applications. Bar Linear Mounting Options SUBMITTAL DRAWING Dayus Register & Grille Phone: (519) 737-1199 Fax: (519) 737-1831 Email: mail@dayus.com Web: www.dayus.com Dayus Register & Grille 5290 Pulleyblank St., RR#1  Windsor, Ontario  N9A 6J3 These mounting options are not available with the J-bead frame