Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.701 Gibson Ave.0086-2021-BRES (37)
DMC 150SS PROFILE CORPORATE HEADQUARTERS: 1234 GARDINER LANE, LOUISVILLE, KY 40213 | 888-321-9630 TOLL-FREE | 502-690-6174 FAX | DREXELMETALS.COM IDEAL APPLICATION COMMERCIAL & RESIDENTIALAVAILABLE WIDTHS 12", 14", 16", 18", and 20"* STANDARD PANEL WIDTHS 16", 20" *Drexel Metals design pressures, wind uplifts and test reports are for specific deck attachments, material gauges, clip spacing and panel widths.A complete specification and listing is available online at www.drexelmetals.com SUBSTRATES AVAILABLE • Painted Galvalume® – 24ga and 26ga • Drexlume® – 24ga and 26ga • Aluminum – .032" • Copper – 16 oz and lead-coated copper • Zinc Our DMC 150SS roof system will lend striking dimension to any architectural design. This versatile 1-1⁄2" mechanically seamed panel can be curved to a wide range of radiuses and applications – from barrel roofs to conical shapes and more. Concealed fasteners and a floating clip system reduce the effect of thermal stresses on the panels, helping to maintain a beautifully smooth, uniform appearance despite fluctuations in temperature. PANEL DETAILS www.drexelmetals.comwww.drexelmetals.com ©2023 Drexel Metals, Inc. All rights reserved. Galvalume® is a registered trademark of BEIC International, Inc. Sherwin-Williams® Coil Coatings is trademark of The Sherwin-Williams Company. Drexlume™ is a trademark of Drexel Metals, Inc. Colors shown represent the actual color as closely as possible. To ensure exact color for final approval, a metal color chip is available. Warranty statements mentioned are outlines; complete Limited Warranty information is available on request. No other warranty expressed or implied is applicable. Please call or visit drexelmetals.com or residentialmetalroof.com for more details. DMC 150SS PROFILE CORPORATE HEADQUARTERS: 1234 GARDINER LANE, LOUISVILLE, KY 40213 | 888-321-9630 TOLL-FREE | 502-690-6174 FAX | DREXELMETALS.COM 02.09.23 DM-15891 - “DMC 150SS Profile Data Sheet” Single lock panel Double lock panel PROFILE OPTIONS • Single lock panel • Double lock panel • Radius panel (single or double lock) FINISHES Available in a wide variety of coatings and colors. See the Drexel Metals color charts for standard colors and paint specifications. PANEL RIB Factory made or field rolled to exact lengths options • Flat Panel • Clip Relief • Striations INSTALLATION Can be installed over steel decking with PolyIso or plywood decking with approved underlayments. Please see Drexel Metals installation details for complete information. SLOPE Minimum slope 2:12 TESTING PRODUCT INFORMATION 35 YEAR WARRANTY - GALVALUME AND ALUMINUM SUBSTRATES 35 year non Pro-rated PVDF Paint Warranty High-performance painted metal roofing product, carefully tensioned leveled for superior flatness. 25 YEAR WARRANTY - DREXLUME SUBSTRATE Mill finished Galvalume® with a two-sided, clear acrylic finish. WARRANTY Small Pencil Small V Striations PROFILE OPTIONS PANEL RIB OPTIONS Testing in accordance with • UL 580 Wind Uplift (Class 90) • TAS 125 Wind Uplift • UL 1897 Extended Phase Wind Uplift • UL 2218 Class 4 Hail Impact • UL 790 Class A Fire Rating • UL Environmental – SRI Third Party Verified • ASTM E1646 Water Infiltration • TAS 100 Wind Driven Rain • ASTM E1680 Air Infiltration • ASTM E1886 Missile Impact • ASTM 2140 Static Pressure Water Head • Miami-Dade County Approved • Florida Building Code Approved • Texas Department of Insurance Approval • UL 263 Fire Certification Flat Panel Bead Large V Large Pencil • Bead • Small and Large V • Small and Large Pencil Clip Relief METSHIELD® HIGH-TEMP HIGH-TEMPERATURE UNDERLAYMENT APPLICATIONS FEATURES AND BENEFITS • Protects the roof structure from water seepage caused by ice dams and wind-driven rains • Resists temperatures up to 250°F without degradation of the adhesive • Seals around roofing nails, staples and screws • Bonds directly to the roof substrate for fast and easy installation without the need for additional adhesives • Split-release film provides easier, faster installation • Resists cracking, drying and rotting, providing long-term waterproofing performance and low lifecycle cost • Concealed waterproofing system will not detract from the architectural aesthetics of the primary roofing system • Exposed rubberized asphalt bead along the membrane edge ensures watertightness of lap seams • Made in USA STANDARDS • UL Classified • ICC-ES ESR #2206 • 2009 and 2012 International Building Code™ • Florida Building Code Approved Product • Meets ASTM D1970 STORAGE MetShield roofing underlayment rolls should be stored on end, under cover and in areas where the temperature is between 40° and 100°F (4.4° and 38°C). Do not doublestack pallets. WARRANTY MetShield is backed by Drexel’s industry-leading warranty. Visit our website for warranty details. INSTALLATION MetShield underlayment is applied when the roof deck is dry and the substrate temperature is 40°F (4.4°C) or higher. At temperatures below 40°F, nailing or priming should be used to temporarily hold the membrane in place while adhesion develops. MetShield is designed to be covered with the primary roofing system and should not be exposed to sunlight for more than 180 days. Moisture: Substrate must be free of any moisture. If moisture is present, it may inhibit adhesion. New construction: Prepare the roof deck by removing all loose objects, dirt, dust and debris. Re-roofing: Remove all old materials from the roof deck in the area to be covered with MetShield underlayment. Best-in-class MetShield ice and water underlayment protects the roof structure from water seepage caused by ice dams and wind-driven rain. Designed specifically for high-temperature applications of Steel, Aluminum, Copper, Zinc*, CRCQ and A606 roof installations. It will resist temperatures up to 250° without degradation of the adhesive, and self- seals around roofing nails, screws and clips used to install the primary roofing system. This high-tensile strength underlayment is a 40 mil SBS modified bitumen with a UV-resistant anti-slip polyethylene woven top facer and is required under all Drexel Metals roof warranted systems. *Although MetShield is compatible with Zinc, Drexel always recommends checking with the Zinc manufacturer to ensure proper project design, backer, and ventilation. Weather Tightness Warranty Approved! CORPORATE HEADQUARTERS: 1234 GARDINER LANE, LOUISVILLE, KY 40213 | 888-321-9630 TOLL-FREE | 502-690-6174 FAX | DREXELMETALS.COM ©2021 Drexel Metals, Inc. All rights reserved. MetShield® is a registered trademark of Drexel Metals, Inc. DensDeck® is a registered trademark of Georgia-Pacific. ENERGY STAR name and logo are registered U.S. marks and are owned by the U.S. government. CAV-GRIP is a trademark of Carlisle Coatings & Waterproofing Incorporated. Warranty statements mentioned are outlines: complete Limited Warranty information is available on request. No other warranty expressed or implied is applicable. CORPORATE HEADQUARTERS: 1234 GARDINER LANE, LOUISVILLE, KY 40213 | 888-321-9630 TOLL-FREE | 502-690-6174 FAX | DREXELMETALS.COM 04.16.21 DM-13412 - “MetShield High-Temperature Underlayment Technical Data Sheet” METSHIELD HIGH-TEMP UNDERLAYMENT Replace water-damaged sheathing and sweep roof deck thoroughly. Priming: Priming is not required on clean, dry wood,metal or most polyisocyanurate surfaces. Masonry and exterior gypsum boards (such as DensDeck ®) should be primed using an appropriate primer or adhesive. Some rigid insulation boards with porous or dusty surfaces may require priming to promote initial adhesion. Priming is required on all substrates when air or substrate temperatures are below 40°F (4.4°C). Adhesives such as CCW-702, CCW- 702WB, CAV-GRIP™ and CCW-AWP are approved for use with Drexel MetShield. Refer to your local building codes to determine acceptable product for use in your region. Selection of roof deck or insulation substrate and/or use of a primer or adhesive are the responsibility of the architect, specifier or roofing contractor to determine based on the roof assembly and environmental conditions. Valleys, hips and ridges: Cut MetShield roofing underlayment into manageable lengths. Align over the center of the valley, hip or ridge. Remove release film. Press the middle of the membrane first before working toward the edges. For open valleys, cover MetShield roofing underlayment with metal valley liners. Eaves and rakes: Cut MetShield underlayment into 10-15' pieces. Remove 2-3' of release film and align the edge of the membrane, sticky side down, so it overhangs the drip edge by 3⁄8" (10 mm). Continue to remove release film and press as you move across the roof. Use a hand roller and/or hand pressure to press into place. Overlap end laps a minimum of 6". MetShield roofing underlayment should reach a point 2' inside the interior wall line. Local codes may require additional courses. If additional courses are required, the top lap must be at least 3 ½". Drip edges: At the rake edge, apply MetShield underlayment first and place drip edge on top. At the eave, apply drip edge first and place MetShield underlayment on top of the drip edge so that it overhangs drip edge by 3⁄8" (10 mm). For standard installation details, follow the MetShield detail drawings. For non- standard installation instructions, contact your local Drexel Metals representative. Metal roof underlayment: Under water-shedding metal roof systems or low-slope metal roofs with a minimum ½" slope, start at the low point and apply MetShield over the full surface of the roof deck. Review the metal roofing manufacturer’s instructions for limitations and precautions. Beginning at the eaves, apply underlayment from the low point to the high point of the roof, running the roll horizontally. LIMITATIONS • MetShield should be installed when air, roof deck and membrane temperatures are at or above 40°F (4.4°C). • MetShield should not be left exposed to sunlight for more than 180 days. • MetShield membrane should not be folded over the roof edge unless protected by a gutter or other flashing materials. • The primary roof system must be ventilated to prevent excessive moisture build-up in the interior structure. • Use caution during the installation of the membrane as it may become slippery when wet or covered with frost. • MetShield must not to be used in contact with flexible PVC material. • MetShield not approved for use in foam set tile applications. PRODUCT SPECIFICATIONS Physical Properties Surface Black/White Engineered Polyolefin Composite Film with Factory-applied Anti-skid Coating Membrane Rubberized Asphalt Physical Properties Units Results Roll Length feet 66 Roll Weight lbs 55 Roll Size sq/ft 198 Roll Width inches 36 Typical Performance Properties Test Method Results Thickness ASTM D1970 40 mils Low Temperature Flexibility ASTM D1970 -45°F Adhesion to Plywood at 75°F ASTM D1970 35 lbs/ft Lap Seam Adhesion at 75°F ASTM D1970 21 lbs/ft Sealability Around Nail ASTM D1970 Pass Slip Resistance ASTM D1970 Pass Thermal Stability ASTM D1970 Pass Moisture Vapor Permeance ASTM D1970 0.02 perms Water Absorption ASTM D1970 0.5% Tensile Strength Machine Direction ASTM D412 250 psi Tensile Strength Transverse Direction ASTM D412 1390 psi Elongation at Break Machine Direction ASTM D412 250% Elongation at Break Transverse Direction ASTM D412 170% 2 VersaShield ® Fire-Resistant Roof Deck Protection Help improve your roof system’s fire resistance while protecting it from damaging moisture with fire-resistant roof deck protection ■ Provides a UL Class A rating on most roof systems1 ■ Helps protect against dangerous flame spread and penetration into the interior ■ Provides a critical layer of extra protection between your roof covering and deck to resist wind-driven rain (or moisture from other sources) that can cause damage to your roof structure We protect what matters most™ Benefits: To learn more about the Lifetime Roofing System visit gaf.com/Lifetime Nominal Specifications: For use with asphaltic shingles, metal, slate, wood, and most other roof systems.2 ■ Roll size: 3.5 squares (350 sq. ft. [32.5m2]) (excludes laps) ■Roll width: 42" (1.07 m) ■Roll length: 100' (30.48 m) ■Approx. roll weight: 53 lb. (24 kg) ■ UV exposure: Resists UV degradation for up to 60 days3 ■ Storage: Do NOT double stack pallets. Always protect from moisture, sunlight, and extreme temperatures during storage. Code Approvals and Standards: ■ Meets or exceeds the physical requirements of ASTM D146, D226 Type II, D828, and D4869 Type IV, D6757 Type I or Type II ■ Component of a UL Listed ANSI/UL 790 Class A system when used with UL Class A shingles. See UL Certifications Directory for ratings with other roof covering assemblies.1 ■ICC ESR-2053 ■ICC AC-160 ■ Miami-Dade County Product Control approved ■State of Florida approved VersaShield ® Fire-Resistant Roof Deck Protection ■ Excellent protection against fire spread and penetration ■ Helps upgrade the UL fire classification of almost any type of roof system, including upgrading most metal roofs to a UL Class A rating1 ■ An efficient fire-resistant slip sheet and roof deck protection all in one product ■ Fiberglass-reinforced so it lies flatter for a better-looking finished roof ■ Slip-resistant walking surface helps improve traction for installers ■ Light color provides a cooler working surface (vs. conventional black felts) ■ Eligible for up to a Lifetime† limited warranty. It’s also an eligible accessory product in the Roof Deck Protection category of GAF residential enhanced warranties. ©2 0 2 3 G A F • R E S G N 2 2 2 - 0 3 2 3 4 1 9 3 4 4 - 0 4 2 3 † Lifetime refers to the length of warranty coverage provided and means as long as the original individual owner(s) of a single-family detached residence [or eligible second owner(s)] owns the property where the qualifying GAF products are installed. For other owners/structures, Lifetime coverage is not applicable. Lifetime coverage on shingles requires the use of GAF Lifetime Shingles only. See the GAF Shingle & Accessory Limited Warranty for complete coverage and restrictions. Visit gaf.com/LRS for qualifying GAF products. Lifetime coverage on shingles and accessories requires the use of any GAF Lifetime Shingle and at least 3 qualifying GAF Accessories. See the GAF Roofing System Limited Warranty for complete coverage and restrictions. For installations not eligible for the GAF Roofing System Limited Warranty, see the GAF Shingle & Accessory Limited Warranty. Visit gaf.com/LRS for qualifying GAF products. 1 Always refer to Underwriters Laboratories Certifications Directory for actual roof system assemblies. 2 Contact GAF Technical Support at 1-800-766-3411 or visit gaf.com for acceptable non-asphaltic roofing systems and limited warranty coverage. 3 60-day UV resistance refers to standardized testing conducted to ensure the product will not physically degrade when exposed to UV. It is NOT related to withstanding water, snow, or wind. While VersaShield® Fire-Resistant Roof Deck Protection is water resistant, it is NOT WATERPROOF. DO NOT USE VersaShield® Fire-Resistant Roof Deck Protection as a temporary roof to protect property or possessions. *When installed in accordance with section 4.2.1 of GAF ESR-2053, VersaShield® can be used over existing wood shakes or shingles as an alternative of the covering materials specified in 1510.4 of the IBC, section R907.4 of the IRC, or section 1513.3 of Chapter 15 Appendix to the UBC. VersaShield ® Fire-Resistant Roof Deck Protection physical/ performance properties VersaShield ® Fire-Resistant Roof Deck Protection Class A rating layer requirements*1 Tensile MD ASTM D146/D828 60 lb./in. width CMD 30 lb./in. width Tensile MD ASTM D1922 400 grams CMD 550 grams Water vapor transmission Permeance ASTM E96 3 Perms minimum Liquid water transmission test ASTM D4896 Pass Roofing material Roof t ype Minimum thickness 15/32" plywood Existing wood shake/shingle Spaced sheathing UL Listed Stone Coated Steel Direct to deck shingle 0.013" 1 Layer N/A 1 Layer UL Classified or Listed Steel Direct to deck shingle 0.013"1 Layer + 30 Felt N/A 1 Layer + 30 Felt Any UL Classified or Listed Steel Batten required shingle 0.013" 1 Layer 2 Layers 1 Layer Any UL Classified or Listed Steel Panel of standing seam 0.015" 1 Layer N/A 1 Layer Any UL Classified or Listed Copper Panel of standing seam 0.016" 1 Layer N/A 1 Layer Any UL Classified or Listed Copper Shingle 0.016" 1 Layer + 30 Felt 2 Layers 1 Layer + 30 Felt Any UL Classified or Listed Aluminum Panel or shingle 0.018" 2 Layers N/A N/A Typical applications for combustible decks Roof covering will determine actual assembly Product Details: LIFETIME LIMITED WARRANTY TERM †