Loading...
HomeMy WebLinkAboutFile Documents.701 Gibson Ave.0086-2021-BRES (40)FEATURES: Stainless steel or copper 86”x 86”x 39”with removable panels on all four sides, panel options are stainless steel, copper or no panels Bench seating Five-six-person hot tub LED Lights 14 jets Water maintenance – ultraviolet/peroxide Dedicated circulation pump Fully insulated Stainless steel starting at $26,500 Copper starting at $34,500 The Monarch Portable Spa Diamond Spas stocked portable hot tub, The Monarch,is the perfect solution for clients who prefer a standard design with a faster ship date. This portable stocked spa is a five-person hot tub that is fabricated with a stainless steel frame and removable access panels on all four sides for easy spa maintenance. Panel options are stainless steel, copper or no panels for drop in installation or client choice. Foam cover options are grey or brown and are ASTM certified. The Monarch stainless steel spa meets California Energy Commission guidelines for CEC and ANSI/APSP-14 certifications. Please call and visit with a Diamond Spas sales associate for further details. INTERIOR VIEW STAINLESS STEEL SPA WITH COPPER PANELS STAINLESS STEEL SPA WITH STAINLESS STEEL PANELS STAINLESS STEEL SPA WITH WOOD PANELS FABRICATED & INSTALLED BY OTHERS COPPER SPA WITH WOOD PANELS FABRICATED & INSTALLED BY OTHERS STAINLESS STEEL SPA WITH NO PANELS 1.800.951.spas (7727) 720.864.9115 fax 866.605.2358 diamondspas.com info@diamondspas.com SPA DATA SURFACE AREA: 32.5 sq. ft. CAPACITY: 388 gallons WATER WEIGHT: 3,235 lbs. SHELL WEIGHT: 1,545 lbs. TOTAL WEIGHT: 4,780 lbs. NEW PROPOSED HOT TUB TO BE INSTALLED IN EXISTING TUB LOCATION 06/08/2021 REVISION CHANGES REV.DESCRIPTION DATE APPROVED A AS DRAWN 12/28/2017 JS B CHANGED SEAT DIMENSIONS AND MOVED JETS 1/10/2018 JS C CHANGED COVER TO BIFOLD AND ADDED STRAPS 1/17/2018 JS D MODIFIED SPA HEIGHT - MODIFIED FRAMING 2/1/2018 MM E EQUIPMENT MODIFIED, WATER VOLUME UPDATED, COVER THICKNESS UPDATED 4/6/2018 MR DSI Internal Use Only: Fabrication Plumbing Project Management Sales SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 1 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA ELECTRICAL 1) Electrical requirements are specified for each unit. Only a licensed qualified electrician should connect the power supply. 2) Some units require more than one supply circuit. All power supply circuits must be located in the same disconnect box. (per NEC) Disconnect box must be more than 5(five) feet away from the tub and less than 50(fifty) feet away and within sight of spa. 3) All spas require a continuous bond. All spas are shipped with a bond connection on the frame. This connection must be made in the field. 4) Never turn the power on to the spa if it is empty. The spa needs water to properly test and satisfy diagnostic computations. 5) All electrical supply to the tub must be GFCI protected. 6) Any nearby electrical outlets, windows, hand rails or metal fencing may have special bonding requirements. Consult your licensed qualified electrician. 7) The communication cables for touch pad, low voltage lighting and water level sensors must be housed in separate conduits from the power supply. Never run communication and line voltage wires together. GAS 1) Gas requirements are specified with each unit. (where applicable) 2) Gas lines must follow guidelines and code requirements for your location. 3) Ventilation and combustion air needs are different for each unit. Please take time to check all proposed heater locations with your gas company or gas fitter to insure adequate combustion air and ventilation.PLUMBING 1) Pipe materials for all pool recirculation and therapy lines to be schedule 40 PVC(ASTM D1785). PVC pipng shall be stamped with N.S.F. seal of approval. All plumbing fittings and pipe must be pressure rated. 2) Prior to connection to spa, all underground plumbing must be pressurized and maintain pressure for 24 hours minimum. 3) All plumbing stub-out locations will be labeled on drawing. Confirm location if applicable. 4) Never handle or lift tub by plumbing. It is the responsibility of the client to make sure that all products are in compliance with local codes andregulations. Certain jurisdictions may require additional testing and/or listing. It is also the responsibilityof the client to arrange and pay for any permits, permit fees, inspections and inspection fees.Consult your local governmental agencies for additional information. Diamond Spas, Inc reserves the right to change , amend and/or modify all or any part of the fabrication including but not limited to vessel and/or equipment design, layout and/or components, at any timewithout notice. Approval of this drawing is acknowledgement of this notice and is legally binding. GENERAL INSTALLATION GUIDELINES Stainless steel and copper can become hot if left in direct sunlight for extended periods of time. DSI recommends undermounting all outdoor spas. NEVER LEAVE THE SPA UN-COVERED WHILE EMPTY excessive heat can build up on the spa if it is not full of water. A solid or opaque covering will suffice. Heat damage is not covered under your warranty. NEVER LEAVE CHILDREN UNATTENDED AROUND SPA 1) Spa must sit on a smooth, flat, level concrete pad. Pad should be a minimum of 4" thick an or as per the structural engineer. 2) The area under the hot tub unit and the equipment must have a waterproof pan or membrane that goes into a drain to prevent flooding or water damage to the region below. 3) Certain applications may use plywood decking and or other material for tub support. 4) PVC and conduit requirements are specified for each tub. Make sure that all underground lines are pressure tested prior to and during back fill. 5) DSI will specify the necessary space requirements for remote location equipment rooms. Equipment rooms are to be no more than 50' from the spa unless previously discussed with DSI. The room is recommended to be at or below the same elevation of the spa. 6) DSI recommends a floor drain in the spa vault and the equipment room vault. 7) Once you have the tub placed and level, connect all water, air and communication lines. All plumbing and communication lines are clearly labeled at the stub out location spa side as well as on the equipment package. DSI recommends that you fill and test the spa at this time to verify proper connection of all water, air and communication lines. 8) Upon inspection of all plumbing and conduits, you may now build the remaining retaining vault wall. Take appropriate precaution that the lines are not disturbed during back fill. 9) It is the responsibility of the owner/user to provide clear and easy access on all sides of the spa for repair. Any costs associated w/ gaining access for repairs will not be incurred by DSI. Inspection ports and/or service access is very important, please take this recommendation into consideration. If you have any questions and or need design ideas please discuss prior to approval w/ your sales rep. STAINLESS STEEL CARE 1) Stainless steel is highly resistant to rust and corrosion. Stainless steel is extremely durable and with proper care and maintenance will maintain it's luster and appearance indefinitely. 2) DSI uses 316L or 304L grade stainless. Each unit has a random hand finish applied to it as all product is hand crafted, exhibiting a visible concise weld seam. 3) DSI recommends rinsing any exposed stainless steel with fresh water on a a regular basis to remove any salt air or pollution contaminate. 4) Minor build up and/or spotting is simply removed with regular care and a "Scotch-Brite" scouring pad. 5) NEVER use steel wool or steel brushes on a DSI product. These products are carbon steel and leave particles that will rust and create stains. 6) If you should notice any staining and/or discoloration on the stainless steel surface it must be removed immediately. Most discoloration and staining is removed with the "Scotch-Brite" scouring pad. After the area is cleaned rinse with fresh water and dry with a a soft cloth. 7) If you have any questions, please contact DSI at 1-800-951-7727 COPPER CARE 1) DSI uses CR110 copper sheets to fabricate all units. All products are custom fabricated and TIG welded by hand. Each product has a hand buffed finish and patina applied to it. 2) Recommended cleaning is a mild detergent and a soft cloth. Wipe after each and every use to avoid water spotting. 3) Unless otherwise specified, DSI does apply a patina and wax after fabrication. This wax does not offer a permanent seal to the copper and only aids in excessive spotting. The copper will continue to spot and react to it's envirionment. Copper is referred to as the "living metal" and in this unsealed state has excellent antimicrobial properties. The wax will need to be reapplied as a maintenance issue. How often it will have to be reapplied depends on severaly factors such as usage, type of water, etc. DSI can also leave the product in its raw copper state upon request. 4) Environment will affect the patina process. Factors such as humidity, heat and water quality will determine what color your copper will turn. 5) Copper has the ability to change many colors such as pink, brown, blue, green etc. We are unable to tell you the exact color your product will change - it simply depends on the environment the product is exposed to. 6) Although rare, the possibility does exist that a deep patina finish may cause color change to parts of the body that come into contact with the bathing surface. To reduce the chance of this occurring, simply clean the bath with a copper cleaner. 7) If you have any questions, please contact DSI at 1-800-951-7727 06/08/2021 86.00 86.00 63.50 73.00 37.00 27.50 16.00 SEAT 16.00 6.50 6.50 30.00 SERVICE ACCESS REQUIRED 39.00 4.38 4.38 4.38 77.25 30.25 1.50 4.38 4.38 4.38 77.25 30.25 1.50 NOTE: WOOD PANEL SHOWN FOR ILLUSTRATION ONLY. PANELS SUPPLIED AND INSTALLED BY OTHER SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 2 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA NOTES: - due to the custom nature and welding processes involved in fabrication, there may be some distortion, warping and or pitting of the flat surfaces on our products. - all inside weld seams will be visible. - spa will be insulated with a 2-part polyurethane foam. SPA DATA - SPA SURFACE AREA = 32.5 SQ. FT. - SPA CAPACITY = 390 GALLONS - SPA WATER WEIGHT = 3,235 LBS. - SPA SHELL WEIGHT = 1,545LBS. - SPA TOTAL WEIGHT = 4,780 LBS. DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/4" TWO PLACE DECIMAL 0.25" 06/08/2021 A A B B CC DD 6.00 OPERATIONAL WATER DEPTH SECTION A-A SCALE 1 : 25 24.00 16.00 12.00 37.00 6.00 OPERATIONAL WATER DEPTH 18.00 E SECTION B-B SCALE 1 : 25 24.00 12.00 27.50 6.00 OPERATIONAL WATER DEPTH 18.00 SECTION C-C SCALE 1 : 25 2.00 SEAT SLOPE 27.50 6.00 OPERATIONAL WATER DEPTH SECTION D-D SCALE 1 : 25 2.00 30.25 DETAIL E SCALE 2 : 25 PANEL RECESS DETAIL SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 3 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA 06/08/2021 8 1 5 3 6 8 8 8 6 6 6 7 7 7 7 7 7 7 7 7 7 7 7 7 7 5 2 NOTES: - PLUMBING: - (2x) 3" PVC - SUCTION - (1X) 2.50" PVC - JET RETURN - (1X) 2" PVC - CIRCULATION RETURN - (1x) 1" CONDUIT - COMMUNICATION AND SPA LIGHT POWER - SPA SHELL TO BE BONDED WITH MIN. 6 GA BARE COPPER CONDUCTER - SPA LIGHT POWER REQUIRES MIN. 14 GA WIRE AUTO COVER:-KEYPAD INSTALLED REMOTELY BY OTHERS,NO MORE THAN 15 FEET FROM AUTOCOVER& WITHIN EYESIGHT-REQUIRES 115V 10 A GFCI SERVICE AT KEYPAD-REFER TO MFG. INSTALALTION INSTRUCTIONS FORKEYPAD INSTALL PROCESS ITEM NO.NO PANELS/QTY.Equipment DESCRIPTION 1 1 STAINLESS STEEL SPA 316SS/304SS SPA SHELL & 304 STAINLESS STEEL 2"x2"x1/8" FRAME 2 1 skimmer - Waterway - strip - 215-6927 stainless steel faced strip type skimmer, 2" PVC soc 3 1 topside control - Balboa - TP800 - #50592 9 button topside control w/LCD display 4 1 SPA LED CONTROLLER #701678-DLO-TLA, SPA LED CONTROL-40, 2 POS, DAISY-LINK, OVERMOLD 5 2 light - Waterway - 3.5 inch - #630-6005 // 3-1/2" face - front access - RGB LED w/ preset lighting patterns - 12 volt -low voltage connection to control #410117-60-0-TLA, CONN, ASSY JUMPER, DAISY-LINK, 60", OVERMOLD (Qty.2) // #701570-14-DLSO-TLA, PCBA, 14 LED, RGB, SPA LIGHT, DAISY LINK W/ STANDOFF,OVERMOLD (Qty.1) 6 2 jet - Waterway - DS P/N 228-2000 directional eyeball w/ 1" orifice - 1psi@30gpm 7 14 WATERWAY MINI STORM JET PNs: 228-0379 CPVC, 916-0024, 229-7921-LS JET - WATERWAY - MINI STORM THREAD 8 4 Balboa Suction - 5 Inch - #39152 Balboa - VGB rated 256gpm - 2008 ASME Certified - 5" Suction SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 4 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA 06/08/2021 10 11 9 1213 54.00 CLEARANCE FOR FILTER SERVICE 25.05 NOTES: - spa requires (1x)230V 50A GFCI service @ equipment for control and heater. - spa shell and all equipment to be bonded w/ min. #6AWG bare copper conductor. 6" FREE FROM FLAMABLE MATERIALS MUST BE MAINTAINED AROUND NATURAL GAS HEATER. REFER TO MANUFACTURER INSTRUCTIONS AND LOCAL CODES FOR PROPER VENTING. - Autofill requires 1/2" fresh water line with backflow and freeze protection located at equipment - GAS HEATER CONFIGURED FOR NATURAL GAS OPERATION SELECT POWER SUPPLY 30A CONTROL: HEATER IS DISABLED WHILE JET PUMP IS IN OPERATION - spa requires (1x)230V 30A GFCI service @ equipment for control and heater. - spa shell and all equipment to be bonded w/ min. #6AWG bare copper conductor. 50A CONTROL: - spa requires (1x)230V 50A GFCI service @ equipment for control and heater. - spa shell and all equipment to be bonded w/ min. #6AWG bare copper conductor. EQUIPMENT AND RELATED ELECTRICAL REQUIREMENTS Item No.NO PANELS/QTY.Equipment Description Voltage H.P./Amps Notes 9 1 control/heater - Balboa - BP2000 - 56377 spa control w/ integrated 5.5kw heater - temperature and flow sensors 230 volt 48 amp requires (1x)230V 50A/60A GFCI service. 230V connection to pumps. 115V connection to UV and ozone. low voltage connection to spa light and topside control. 10 1 filter - Waterway - 100 sq/ft cartridge - 502-9910 100 sq.ft. cartridge filter w/ 1 gpm/sq.ft. filtration rate, mechanical bypass requires 54" vertical height to service/replace cartridge filter 11 1 pump - Waterway - Iron Might - 3J10070-1E Centrifugal pump and motor, 1/8 h.p., 40gpm@10ft.TDH, 1-1/2" suction, 1-1/2" discharge 230 volt 1.3 amp 12 1 pump - Waterway - Executive 56 - 4hp - 372162A-13 2-speed centrifugal pump and motor, 4 h.p., 130gpm @ 60 ft.TDH, 2 1/2" suction, 2" discharge 230 volt 4 h.p.- 4.4 amp / 12 amp 230V connection to control 13 1 UV - Delta - EA-4H-5 35W UV sterilizer, 16gpm max. flow rate, 2" union connections 115/230 < 1 amp 115V connection to control SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 5 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA ** A MINIMUM OF 22 CUBIC FEET OF FREE OPEN AREA MUST BE PROVIDED ADJACENT TO EQUIPMENT FOR PROPER VENTALATION.** 06/08/2021 86.00 86.00 43.00 43.00 8.00 FOLD 5.00 4.00 4.00 SKIRTING COVER TAPERED FOR DRAINAGE GG H SECTION G-G 4.00 DETAIL HSCALE 1 : 10 4" SKIRT FEMALE CLIP INSTALLED ONSITE BY CUSTOMER AS PER DSI INSTRUCTIONS COVER STRAP INSTALLED ONSITE BY CUSTOMER AS PER DSI INSTRUCTIONS MALE COVER STRAP CLIP FOAM COVER GREY BROWN SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 6 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-235868 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA FLOATING FOAM COVER *FLOATING COVERS DO NOT MEET SAFETY BARRIER REQUIREMENTS* NOTES: *PROJECTS WILL NOT BE SCHEDULED UNTIL COVER COLOR IS SELECTED* COVER MANUFACTURER MAINTAINS A -1.0" TOLERANCE ON OVERALL COVER DIMENSIONS ASTM TAPERED FOAM COVER COVER MANUFACTURER MAINTAINS A +1.0" TOLERANCE ON OVERALL COVER DIMENSIONS 06/08/2021 30.00 77.00 77.0 30.0 QTY QTY QTY STAINLESS STEEL PLEASE CHECK THIS BOX IF YOU DO NOT WANT ACCESS PANELS 77.0 30.0 COPPER 30.00 77.00 IPE IPE IS A NATURAL HARDWOOD. COLORS AND GRAINS WILL VARY. STAINLESS STEEL CARE 1) STAINLESS STEEL IS HIGHLY RESISTANT TO RUST AND CORROSION. STAINLESS STEEL IS EXTREMELY DURABLE AND WITH PROPER CARE AND MAINTENANCE WILL MAINTAIN IT's LUSTER AND APPEARANCE INDEFINITELY. 2) DSI USES 316L OR 304L GRADE STAINLESS. EACH UNIT HAS A RANDOM HAND FINISH APPLIED TO IT AS ALL PRODUCT IS HAND CRAFTED, EXHIBITING A VISIBLE CONCISE WELD SEAM. 3) DSI RECOMMENDS RINSING ANY EXPOSED STAINLESS STEEL WITH FRESH WATER ON A A REGULAR BASIS TO REMOVE ANY SALT AIR OR POLLUTION CONTAMINATE. 4) MINOR BUILD UP AND/OR SPOTTING IS SIMPLY REMOVED WITH REGULAR CARE AND A "SCOTCH-BRITE" SCOURING PAD. 5) NEVER USE STEEL WOOL OR STEEL BRUSHES ON A DSI PRODUCT. THESE PRODUCTS ARE CARBON STEEL AND LEAVE PARTICLES THAT WILL RUST AND CREATE STAINS. 6) IF YOU SHOULD NOTICE ANY STAINING AND/OR DISCOLORATION ON THE STAINLESS STEEL SURFACE IT MUST BE REMOVED IMMEDIATELY. MOST DISCOLORATION AND STAINING IS REMOVED WITH THE "SCOTCH-BRITE" SCOURING PAD. AFTER THE AREA IS CLEANED RINSE WITH FRESH WATER AND DRY WITH A A SOFT CLOTH. 7) IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT DSI AT 1-800-951-7727 COPPER CARE 1) DSI USES CR110 COPPER SHEETS TO FABRICATE ALL UNITS. ALL PRODUCTS ARE CUSTOM FABRICATED AND TIG WELDED BY HAND. EACH PRODUCT HAS A HAND BUFFED FINISH AND PATINA APPLIED TO IT. 2) RECOMMENDED CLEANING IS A MILD DETERGENT AND A SOFT CLOTH. WIPE AFTER EACH AND EVERY USE TO AVOID WATER SPOTTING. 3) UNLESS OTHERWISE SPECIFIED, DSI DOES APPLY A PATINA AND WAX AFTER FABRICATION. THIS WAX DOES NOT OFFER A PERMANENT SEAL TO THE COPPER AND ONLY AIDS IN EXCESSIVE SPOTTING. THE COPPER WILL CONTINUE TO SPOT AND REACT TO IT's ENVIRONMENT. COPPER IS REFERRED TO AS THE "LIVING METAL" AND IN THIS UNSEALED STATE HAS EXCELLENT ANTIMICROBIAL PROPERTIES. THE WAX WILL NEED TO BE REAPPLIED AS A MAINTENANCE ISSUE. HOW OFTEN IT WILL HAVE TO BE REAPPLIED DEPENDS ON SEVERAL FACTORS SUCH AS USAGE, TYPE OF WATER, ETC. DSI CAN ALSO LEAVE THE PRODUCT IN ITS RAW COPPER STATE UPON REQUEST. 4) ENVIRONMENT WILL AFFECT THE PATINA PROCESS. FACTORS SUCH AS HUMIDITY, HEAT AND WATER QUALITY WILL DETERMINE WHAT COLOR YOUR COPPER WILL TURN. 5) COPPER HAS THE ABILITY TO CHANGE MANY COLORS SUCH AS PINK, BROWN, BLUE, GREEN ETC. WE ARE UNABLE TO TELL YOU THE EXACT COLOR YOUR PRODUCT WILL CHANGE - IT SIMPLY DEPENDS ON THE ENVIRONMENT THE PRODUCT IS EXPOSED TO. 6) ALTHOUGH RARE, THE POSSIBILITY DOES EXIST THAT A DEEP PATINA FINISH MAY CAUSE COLOR CHANGE TO PARTS OF THE BODY THAT COME INTO CONTACT WITH THE BATHING SURFACE. TO REDUCE THE CHANCE OF THIS OCCURRING, SIMPLY CLEAN THE BATH WITH A COPPER CLEANER. 7) IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT DSI AT 1-800-951-7727 IPE CARE 1) IPE PANELS SHOULD BE PERIODICALLY RESEALED USING AN OIL BASED SEALER MADE FOR IPE 2) DSI RECOMMENDS CLEANING WITH A MILD DETERGENT AND A SOFT CLOTH. WIPE AFTER EACH AND EVERY USE TO AVOID WATER SPOTTING. 3) KEEP IPE PANELS CLEAN FROM TREE DROPPINGS, LEAVES & OTHER DIRT. 4) IPE IS AN EXTREMELY DURABLE HARDWOOD HOWEVER, ENVIRONMENTAL FACTORS WILL AFFECT THE AGEING PROCESS. FACTORS SUCH AS HUMIDITY, HEAT AND EXPOSURE TO WATER WILL INFLUENCE BOTH THE BEAUTY AND LONGEVITY OF THIS PRODUCT. 5) IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT DSI AT 1-800-951-7727 PANELS ARE ATTACHED TO SPA USING (4X) 10-32 FLAT HEAD COUNTER SUNK SCREWS SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 4/19/2018 4/19/2018 7 8 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA SHEET OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-235878 304 / 316 L STAINLESS STEEL MONARCH PORTABLE SPA FLOATING FOAM COVER *FLOATING COVERS DO NOT MEET SAFETY BARRIER REQUIREMENTS* NOTES: *PROJECTS WILL NOT BE SCHEDULED UNTIL COVER COLOR IS SELECTED* COVER MANUFACTURER MAINTAINS A -1.0" TOLERANCE ON OVERALL COVER DIMENSIONS ASTM TAPERED FOAM COVER COVER MANUFACTURER MAINTAINS A +1.0" TOLERANCE ON OVERALL COVER DIMENSIONS 06/08/2021 PRIMARY CONTACT: PHONE #: EMAIL: INSTALLATION ADDRESS: CITY: STATE: ZIP CODE: DELIVERY CONTACT: PHONE #: "All service and repairs require access to the outside of the spa. The purchaser accepts the related responsibility for the method of access selected as part of the architectural design outside of the DSI scope of work. These drawings do not include access unless it is part of the metal fabrication we provide." Diamond Spas, Inc reserves the right to change,amend and/or modify any part of the spa fabrication/equipment design without prior notice. Approval of this drawing is acknowledgement of this notice and legally binding. By signing this page and checking "approved as drawn" I acknowledge that I have read and understand all pages in this document. I further acknowledge and agree that I am a fully authorized agent acting on behalf of the owner, have the requsite authority to bind the owner, and have informed the owner of the terms and conditions. Digital acknowledgements and signatures are legally binding. Access Methods below have been reviewed and considered (Checkbox) Date: ACCESS METHODS: Construct a crawl space a person can enter to make repair, minimum 18" wide. Plan to construct removable panels to gain access. - Metal Panel constructed by DSI - Panel Constructed by others Plan for a method to slide, move, or hoist the spa to gain access. Plan for demolition to occur to gain access. Plan to hoist spa as necessary Other method-PLEASE DESCIRIBE NOTE: installer should test the spa for leaks prior to completing surrounding finishes. MONARCH PORTABLE SPA 304 / 316 L STAINLESS STEEL 88 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Rotary Hand Brushed FINISH MATERIAL ARE IN INCHES. DO NOT SCALE DRAWING UNLESS OTHERWISE SPECIFIED DIMENSIONS OF SHEET 4/19/2018 4/19/2018 06/08/2021 06/08/2021 NOTES 50A CONTROL: Spa requires (1x) 230V 50A GFCI service equipment for control and heater Spa shell and all equipment to be bonded w/ min. #6AWG bare copper conductor The Monarch Portable Spa s p e c i f i c a t i o n s 1.800.951.spas (7727) 720.864.9115 fax 866.605.2358 diamondspas.com info@diamondspas.com CERTIFICATIONS: stainless steel shells only: Certified to meet CEC Appliance Efficiency Standards for Portable Electric Spas Certified to meet ANSI/APSP-14 Standard for Portable Spa Energy Efficiency stainless steel & copper shells: IAPMOEGS listing for UL 1795 and CSA C22.2 standards NOTE: Dimensions, design and equipment cannot be modified. 06/08/2021 06/08/2021 06/08/2021 RELAY ® HOT SPOT® COLLECTION 7’ x 7’ x 36” Dimensions FROG® In-Line Cartridge Ready Water Care 6 People 230 Voltage 40 Jets Lounge Seating EXISTING HOT TUB CURRENTLY INSTALLED TO BE REMOVED 06/08/2021 HOT SPOT® COLLECTIONRELAY® Relay spa shown with Alpine White shell, Storm cabinet and Storm Hot Spot Collection Step. Shell Colors Cabinet Colors Cover Colors AlpineWhite Pearl TuscanSunPebble Almond Havana Storm Nutmeg Stone Actual colors and products may vary from print representation. See dealer to verify. *Includes water and 6 adults weighing 175 lbs. each. Export models available in 240 V, 50 Hz, 2,000 W heater. © 2021 Watkins Wellness • Rev. D Seating Capacity 6 people Dimensions 7’ x 7’ x 36” / 2.13 m x 2.13 m x 0.92 m Water Capacity 340 gallons / 1,290 liters Weight 830 lbs. / 375 kg dry; 4,715 lbs. / 2,140 kg filled* Jets 40 total • 3 XL Directional Hydromassage jets • 2 XL Rotary Hydromassage jets • 3 Directional Hydromassage jets • 2 Rotary Hydromassage jets • 30 Directional Precision® jets Water Feature Included Jet Pump 1 Wavemaster® 6200; Two-speed, 1.5 HP Continuous Duty, 3.2 HP Breakdown Torque Jet Pump 2 Wavemaster® 6000; One-speed, 1.5 HP Continuous Duty, 3.2 HP Breakdown Torque Floor Drain Included Water Care System FROG® In-Line Cartridge Ready Control System IQ 2020® 230 V / 50 amp, 60 Hz (Includes G.F.C.I. protected sub-panel) Lighting – Interior 10 multi-color LED points of light, dimmable Lighting – Exterior 4 multi-color LED points of light, dimmable Heater No-Fault® 4,000 W / 230 V Energy Efficiency FiberCor® Insulation; Certified to California Energy Commission (CEC) and APSP 14 energy efficiency standards for portable spas Effective Filtration Area 65 sq. ft., top loading Vinyl Cover 3.5” to 2.5” tapered, 2 lb. density foam core Available Options Cover Lifter CoverCradle®, CoverCradle II, or UpRite® Steps Hot Spot Collection Step (Almond, Havana, and Storm), Polymer Step (Ash) Entertainment Wireless Sound System 06/08/2021 1 Leila Schwyhart From:Elizabeth Lozner <elozner@klaa.com> Sent:Thursday, April 1, 2021 2:43 PM To:Rob Russell; Leila Schwyhart Cc:Rachael Dobosiewicz; Kent Bumgarner Subject:Re: Bauhaus Structural progress notes Rob & Leila- Thanks for finding out more about the existing spa. They are indeed very similar and the new spa does not increase the load on existing structure. Get Outlook for iOS Elizabeth Lozner, PE Project Manager T: 970.927.5174 D: 970.510.5707 From: Rob Russell <rob@keyelementsconstruction.com> Sent: Thursday, April 1, 2021 12:59:49 PM To: Elizabeth Lozner <elozner@klaa.com>; Leila Schwyhart <Leila@bldgseed.com> Cc: Rachael Dobosiewicz <rdobosiewicz@klaa.com>; Kent Bumgarner <kent@keyelementsconstruction.com> Subject: RE: Bauhaus Structural progress notes Hi Elizabeth, I went up to Aspen today and have info: The existing spa is a Hot Spot “Relay”. I’ve attached the spec sheet for this spa, as well as the spec sheet for the proposed Diamond Spa. Let me know if you need anything else. Rob email: rob@keyelementsconstruction.com 06/08/2021