HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0028-2023-BCHO (3)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SEE NOTES #1 PLANS
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
09/12/2023
justinh
SEE NOTES #1 PLANS
APPLICATION ACCEPTED DATE: 2023-04-17 PERMIT NUMBER: 0028-2023-BCHO
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 855 CHATFIELD RD UNIT:
PARCEL ID: 273502402006 LEGAL DESCRIPTION: WEST ASPEN
OWNER: CHATFIELD VIEW LLC
PERMIT CONTRACTOR: SCHLUMBERGER SCHERER CONSTRUCTION
DESCRIPTION OF WORK Small snowmelt addition to existing permit
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D
BUILDING TYPE (IRC) One family REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE
OCCUPANCY GROUP (IBC) WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. 3,242
HISTORIC PROPERTY? No TOTAL POOL SQ.FT. 111
FIRE SPRINKLER EXISTING?
CITY OF ASPEN|2022 427 RIO GRANDE PL| ASPEN, CO
81611
External Energy Use Approved
RREMP CREMP
PERMIT #:_______________DATE:________
SNOWMELT:_____________________________
POOL: _____________________________
SPA: _____________________________
OFFSET:________________________________
REMP SHEET: __________________________
REVIEWED BY: _________________________
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S.
All snowmelt systems shall meet the following:
-Any portions in the Right of Way must be on a separate zone. A ROW
permit and Permanent Encroachment License are required.
-R10 insulation shall be installed under the area to be snow melted or R5
insulation shall be installed under and at the slab edges. (Ordinance 11
Series 2011)
-Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling. (2009 IECC
Sec. 403.8 & 503.2.4.5)
-Automatic or manual controls installed for system shut off when outdoor
temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5)
-Inspection by testing hydrostatically at 1½ times max system design
pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec.
1208.1)
MINIMUM BOILER AFUE: _________________
18.87kW PV
X
0028-2023-BCHO 9/12/23
3242 sq.ft.
111 sq.ft.
LS 3.0
97%
JH