HomeMy WebLinkAboutFile Documents.1265 Red Butte Dr.0032-2023-BCHO (5)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SEE NOTES #1 PLANS
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
luisp
04/24/2023ZONING
05/11/2023
linzhid
REFERENCES FROM 2015 IRC
CV/A = crawl space ventilation required, sec. R408.1 Access required, R408.4
EE = emergency escape required sec R310.1
EU = enclosed usable space under stairs shall be ½” Gyp, sec R302.7
G/D = garage/dwelling separation, sec R302.5 and R302.6
STC = Sound transmission class not less than 45 at dwelling separations, app
K
RV = roof and rafter ventilation required, R806.1
A = attic access 22” x 30”, 30” headroom above, R807.1
SA = smoke alarms installed to NFPA 72 requirements, sec R314
CO = carbon monoxide detector per City Ordinance 41 series 2008
SG = safety glazing required, sec R308.4
GR = guardrails, 36” min ht, 4” max opening; req at 30” drop any point w/in 36”
horizontally, sec R312
WFP = window fall protection- operable window <24” AFF & >72” above
grade: use opening control device listed to ASTM F2090, sec R312.2
HR = handrails 34”-38” ht, sec R311.7.8
SI = stairway illumination, sec R303.7
PD = protect against decay, sec R317
REFERENCES FROM 2015 IMC
V = bathroom and balanced whole house mechanical ventilation req.
Ordinance 40, 2016
DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM
AS = access and service space for maintenance req’d, sec 306
MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2
ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes,
501.3.1
IT= intake openings 10’ from lot line & contaminant sources (vents, streets),
401.4
D = fasten and seal all ductwork per 603.9
REFERENCES FROM 2015 IFGC
DV = direct vent req’d, sec 303.3
CA = combustion air not taken from bedrooms, bathrooms or
storage sec 303.3
OD = outdoor appliances must be listed for outdoor use, sec 303.6
REFERENCES FROM 2015 IECC
F = new or replacement glazing shall not exceed 0.28 U-Value, NFRC label
required, Ordinance 40, 2016
L = 75% of lamps in permanently installed lights must be high efficacy, sec
R404.1
SE = Continuous air barrier required; all exterior joints, cracks, and holes to be
caulked, gasketed, sealed, table R402.4.1.1
REFERENCES FROM 2014 NEC
EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26
0032-2023-BCHO
ASPEN SOAP WASH LLC
1265 RED BUTTE DR
273501306003
Page 1 of 1
Job Name: 1265 Red Butte
Job #: 23018
Date: 06/21/2023
Calcs By: B.G.K.
Assembly
Window Assembly Fixed Cardinal 6MM Double 366-Clear-i89 2 81 107 17,334 68 95 12888 0.224 1335 0.379 3,112 0.480 0.28
120 0.28
1. Rader Engineering Inc. Disclaimer: The above U-Factors were determined using the methods in the 2017 ASHRAE Handbook,
values are calculated estimates. The above window was NOT formally tested by the NFRC.
U-Value
UT
Assembly Area (ft.2)Calculated Assembly Area Weighted U-Value
Width
(in.)
Height
(in.)
Area ACG
(in.2)
U-Value
UCG
Area AEG
(in.2)
U-Value
UEG
Unit ID Assembly Type Nom. W
(in.)
Nom. H
(in.)
Area AT
(in.2)
Edge of Glass TOT Frame TOT
Area AF
(in.2)
U-Value UF
ASHRAE Fenestration Performance Calculations
(Refer to Chpt. 15 of 2021 Fundamentals ASHRAE handbook)
Assembly PANEL TOT Center of Glass TOT
QTY OF PANELS
Memorandum of Policy
Building Codes
From: Mike Metheny
Date: May 10, 2018
Revised:
Date: June 1, 2020
Subject: Fenestration U-factor Documentation The following are acceptable methods under the IECC to verify fenestration U-factors as part of the building thermal envelope: 1. NFRC certification, factory assembled: NFRC label applied to window assembly and verified at field inspection. 2. NFRC certification, site assembled: provide an NFRC CPD number or certificate of authorization from an NFRC authorized inspection agency prior to permit approval. To document the chain of custody, project specific NFRC labels must be affixed to the units or a project specific NFRC label certificate must be provided prior to field inspection. 3. Provide a simulation or test by an NFRC–accredited lab in accordance with NFRC-100 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the simulation or test is required prior to field inspection. 4. Provide a calculation using 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3: “U-Factor (Overall Coefficient of Heat Transfer)” prior to permit approval. Calculation is required to be in the standard NFRC window size of 47.2” x 47.2”. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the calculation is required prior to field inspection. 5. Use default values from Table 4 U-Factors for Various Fenestration Products in 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the values is required prior to field inspection. 6. Use default values from IECC tables in chapter 3 of the residential and commercial sections.
Architectural Windows and Doors
0097 County Road 114
Glenwood Springs, Colorado 81601
www.awd.cc
Contact: Gary Grossman
Phone 970-928-9314
Email: garyawd@aol.com
Quote Number:141295 PO Number: Printed Date:Jun 15, 2023 10:57 AM
Job Name:KUNOFSKY RESIDENCE Tag Name:KUNOFSKY RESIDENCE
Quote prepared for TIMBERLINE CONSTRUCTION
Business
ERIC FISHER
BASALT, CO 81621
Cellular: 720-377-4198
06/22/2023 Jun 15, 2023 10:57 AM Quote: 141295 Job Name: KUNOFSKY RESIDENCE Tag: KUNOFSKY RESIDENCE 2 - of -4
Loewen Proposes to Furnish The Products Within This Quote - Errors and Omissions Excepted
Group 1
Item: 1 Qty: 1 Mulled Composite Unit Label: MEDIA ROOM Each Price Extended Price
Exterior View
Frame Size : 162" (4115mm) x 107" (2718mm)Rough Opening : 162 3/4" (4134mm) x 107 3/4" (2737mm)
Casing Not Required
Composite Options
MEDIA ROOM
Unit - Unit - Unit
Number of Sub Units: 3
Rectangular (Or Square)
Curtain Wall Insert Cladding
Field Mull Required
Sub Units
Picture
Picture
Picture
Combo Dimension Details
Jamb: 4 9/16" (116mm)
Base Jamb: 4 1/32" (102mm)
Finish Options
Frame: Dark Bronze Anodized Clad
(Std)
Int Frame: Natural Wood
Attachment Options
Nailing Flange: All Four Sides
Wood Type Options
Douglas Fir
Miscellaneous Options
Cubes: 77
N
Performance Data
UNAVAILABLE
$11,312.20 $11,312.20
COMBINATION BASE PRICE
$174.31 $174.31
Sub Item: 1-1 (2)Qty: 1 Picture (Direct Set)Label: MEDIA ROOM Sub Price Sub Extended
Exterior View
Frame Size : 54" (1372mm) x 107" (2718mm)
Unit Shape/Build Options
Not Impact Certified
Curtain Wall Insert Cladding
Douglas Fir
Picture (Direct Set) - 2019
Dimension Details
Jamb: 4 9/16" (116mm)
Base Jamb: 4 1/32" (102mm)
Finish Options
Frame: Dark Bronze Anodized
Clad (Std)
Sash: Sash Color Matches Frame
Color
Int Frame: Natural Wood
Glazing Options
Double 366-Clear
Interior Surface LOW-E - i89
All Panes Tempered
6 MM Glass Thickness
Black Stainless Steel Spacer
Black Bar(63) 1/2"(13mm)
Preserve Film on INT & EXT
C/W Capillary Tubes Less Argon
Casing Options
No Cas-Component Unit-Check
Parent
Miscellaneous Options
Cubes: 27
N
Performance Data
Not Impact Certified
U-Value Imperial (USA): 0.24
U-Value Metric (CDN) USI: 1.36
Solar Heat Gain Coefficient: 0.24
Visible Transmittance: 0.55
C P D Number: LOW-N-111
01682-00001
Performance Grade:
UNAVAILABLE
$4,389.63 $4,389.63
BASE PRICE
$2,796.61 $2,796.61
CUSTOM CUTTING PRICING
$72.81 $72.81
TEMPERED PRICING
$969.71 $969.71
LOW E PRICING
$550.50 $550.50
06/22/2023
Jun 15, 2023 10:57 AM Quote: 141295 Job Name: KUNOFSKY RESIDENCE Tag: KUNOFSKY RESIDENCE 3 - of -4
Loewen Proposes to Furnish The Products Within This Quote - Errors and Omissions Excepted
Sub Item: 1-2 (3)Qty: 1 Picture (Direct Set)Label: MEDIA ROOM Sub Price Sub Extended
Exterior View
Frame Size : 54" (1372mm) x 107" (2718mm)
Unit Shape/Build Options
Not Impact Certified
Curtain Wall Insert Cladding
Douglas Fir
Picture (Direct Set) - 2019
Dimension Details
Jamb: 4 9/16" (116mm)
Base Jamb: 4 1/32" (102mm)
Finish Options
Frame: Dark Bronze Anodized
Clad (Std)
Sash: Sash Color Matches Frame
Color
Int Frame: Natural Wood
Glazing Options
Double 366-Clear
Interior Surface LOW-E - i89
6 MM Glass Thickness
Black Stainless Steel Spacer
Black Bar(63) 1/2"(13mm)
Preserve Film on INT & EXT
C/W Capillary Tubes Less Argon
Casing Options
No Cas-Component Unit-Check
Parent
Miscellaneous Options
Cubes: 27
N
Performance Data
Not Impact Certified
U-Value Imperial (USA): 0.24
U-Value Metric (CDN) USI: 1.36
Solar Heat Gain Coefficient: 0.24
Visible Transmittance: 0.55
C P D Number: LOW-N-111
01682-00001
Performance Grade:
UNAVAILABLE
$3,374.13 $3,374.13
BASE PRICE
$2,796.61 $2,796.61
CUSTOM CUTTING PRICING
$72.81 $72.81
LOW E PRICING
$504.71 $504.71
Sub Item: 1-3 (4)Qty: 1 Picture (Direct Set)Label: MEDIA ROOM Sub Price Sub Extended
Exterior View
Frame Size : 54" (1372mm) x 107" (2718mm)
Unit Shape/Build Options
Not Impact Certified
Curtain Wall Insert Cladding
Douglas Fir
Picture (Direct Set) - 2019
Dimension Details
Jamb: 4 9/16" (116mm)
Base Jamb: 4 1/32" (102mm)
Finish Options
Frame: Dark Bronze Anodized
Clad (Std)
Sash: Sash Color Matches Frame
Color
Int Frame: Natural Wood
Glazing Options
Double 366-Clear
Interior Surface LOW-E - i89
6 MM Glass Thickness
Black Stainless Steel Spacer
Black Bar(63) 1/2"(13mm)
Preserve Film on INT & EXT
C/W Capillary Tubes Less Argon
Casing Options
No Cas-Component Unit-Check
Parent
Miscellaneous Options
Cubes: 27
N
Performance Data
Not Impact Certified
U-Value Imperial (USA): 0.24
U-Value Metric (CDN) USI: 1.36
Solar Heat Gain Coefficient: 0.24
Visible Transmittance: 0.55
C P D Number: LOW-N-111
01682-00001
Performance Grade:
UNAVAILABLE
$3,374.13 $3,374.13
BASE PRICE
$2,796.61 $2,796.61
CUSTOM CUTTING PRICING
$72.81 $72.81
LOW E PRICING
$504.71 $504.71
06/22/2023
Jun 15, 2023 10:57 AM Quote: 141295 Job Name: KUNOFSKY RESIDENCE Tag: KUNOFSKY RESIDENCE 4 - of -4
Loewen Proposes to Furnish The Products Within This Quote - Errors and Omissions Excepted
Totals
Submitted By :
Accepted By :
Date :
Net Material:$11,312.20
Subtotal:$11,312.20
Misc Charge:$0.00
Aspen City Limits (9.3%):$1,052.03
Deposit:$0.00
Total:$12,364.23
This quote is valid for 30 days. All window and door specifications are the sole responsibility of the purchaser. Please review all specifications, including dimensions,
glazing, functions, colors, finishes, handings and hardware selections with your Architectural Windows & Doors, Inc. sales representative prior to signing off on this
order to insure 100% accuracy. Once the order is placed with the factory it cannot be cancelled or modified. All of these products are made to order and cannot be
returned to Architectural Windows & Doors, Inc. for credit or other consideration. Any shortages must be reported within 7 business days from the date of delivery
to the job site. The purchaser is responsible for inspecting the goods received and should refer to our itemized delivery ticket when verifying missing or incorrect
items. Product representations and warranties are the sole responsibility of the manufacturer.
Note: Structural support may be required around and between mulled units. The size and type to be determined by a structural engineer.
Prices are subject to change without notice.
Please review and report any errors or changes immediately.
Loewen, at its sole discretion, will seek to accommodate changes to orders that have been submitted.
All changes requested after submission will be subject to additional charges as determined by Loewen.
There will be instances where changes to an order in progress will not be possible.
Load dates may be modified due to the changes requested.
All quotes and orders that meet any of the following criteria must be approved by Loewen prior to quotation
or bid submittal by dealer:
(i) valued at over $300,000 Net Loewen sell price, or
(ii) for Commercial building projects, or
(iii) with specification for product performance and/or on-site testing
Loewen reserves the right to require special terms and conditions on sales of these projects or to decline them outright.
Loewen shall have no liability of any kind for any losses or damages due to any delays in fulfilling orders, delays in meeting delivery dates or delays in shipping, or
any losses or damages resulting from causes beyond the immediate and direct control of Loewen.
Jun 15, 2023 10:57 AM
06/22/2023