HomeMy WebLinkAboutFile Documents.901 E Hyman Ave.0009-2022-BRES (14)System No. C-AJ-5090 SECTION A-A CA J 5 0 9 0 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 14, 2015 A 3 2 1 5B 5A 4 3 5B C CL A S S IFI E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US Page: 1 of 2 ANSI/UL1479 (ASTM E814)CAN/ULC S115 )5DWLQJV²DQG+U 6HH,WHP )5DWLQJV²DQG+U 6HH,WHP 75DWLQJ²+U )75DWLQJ²+U /5DWLQJ$W$PELHQW²&)0VTIW )+5DWLQJV²DQG+U 6HH,WHP /5DWLQJ$W)²/HVV7KDQ&)0VTIW )7+5DWLQJ²+U /5DWLQJ$W$PELHQW²&)0VTIW /5DWLQJ$W)²/HVV7KDQ&)0VTIW Page: 2 of 2 CA J 5 0 9 0 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 14, 2015 )ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWH Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 18 in. (457 mm). See Concrete Blocks (CAZT) Category in the Fire Resistance Directory for names of manufacturers. 0HWDOOLF6OHHYH² 2SWLRQDO ²1RPLQ PP GLDP RUVPDOOHU 6FKHGXOH RUKHDYLHU VWHHOVOHHYHFDVWRUJURXWHGLQWRIORRURUZDOO assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. 7KURXJK3HQHWUDQWV²2QHPHWDOOLFSLSHRUWXELQJWREHFHQWHUHGZLWKLQWKHILUHVWRSV\VWHP3LSHRUWXELQJWREHULJLGO\VXSSRUWHGRQERWK sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used: $6WHHO3LSH²1RPLQ PP GLDP RUVPDOOHU 6FKHGXOH RUKHDYLHU VWHHOSLSH %&RSSHU3LSH²1RPLQ PP GLDP RUVPDOOHU 5HJXODU RUKHDYLHU FRSSHUWXELQJ &&RSSHU7XELQJ²1RPLQ PP GLDP RUVPDOOHU 7\SH/ RUKHDYLHU FRSSHUWXELQJ 7XEH,QVXODWLRQ²3ODVWLFV²0LQLQ PP WRPD[LQ PP WKLFNDFU\ORQLWULOHEXWDGLHQHSRO\YLQ\OFKORULGH $%39& IOH[LEOH foam furnished in the form of tubing. Nom 1 in. (25 mm) thick AB/PVC flexible foam insulation may be used for max 2 hr F and FH Ratings when max 3 in. (76 mm) diam pipe or tubing is used. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When max annular space exceeds 1-1/2 in. (38 mm) the F and FH Ratings are 2 hr. See Plastics+ (QMFZ2) Category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used. )LUHVWRS6\VWHP²7KHILUHVWRSV\VWHPVKDOOFRQVLVWRIWKHIROORZLQJ $3DFNLQJ0DWHULDO²0LQLQ PP WKLFNQHVVRIPLQSFI NJP PLQHUDOZRROEDWWLQVXODWLRQILUPO\SDFNHGLQWRRSHQLQJDVD permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. %)LOO9RLGRU&DYLW\0DWHULDO ²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKWRSVXUIDFHRI floor or with both surfaces of wall. When max annular space exceeds 1-1/2 in. (38 mm) the min thickness of fill material is 1/2 in. (13 mm). +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)62QH6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.