HomeMy WebLinkAboutFile Documents.1039 E Cooper Ave.0116-2023-BRES (6)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
09/18/2023
09/22/2023
jimp
Type VA Construction
Codes: 2021 IBC, 2021 IEBC,
2020 NEC, 2021 IPC
READ THIS OR FAIL YOUR INSPECTION!
Dropped Ceilings and Soffits beneath fire rated
assemblies
2021 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
1. Dropped Ceilings & Soffits: If dropped 1 ¾
inches or less, do one of the following:
-Fill spaces with Class A material.
-Fill spaces with inorganic or non-combustible material.
-Fire block 8 feet in all directions.
2. Dropped Ceilings & Soffits: If dropped greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
3. Dropped Ceilings & Soffits below Heavy
Timber T&G ceilings, do all of the following:
-One layer 5/8” type X gypsum board directly
attached with minimum level one finish.
-Drop ceiling according to item 1 or 2 above as
applicable.
(City Policy)
100% of lamps in
permanently installed light
fixtures must be high efficacy
- IECC R404.1
IF ROOF/CEILING IS FULLY EXPOSED:
INSULATION REQUIRED
If finish materials are removed to expose framing
cavities or dropped ceilings are removed to expose
areas where insulation can be installed in the
thermal envelope, insulation must be installed:
Residential: R-49
Commercial: R-60
Ordinance 1, 2023
IF FRAMING CAVITIES ARE EXPOSED:
QUALITY INSULATION REQUIRED
If finish materials are removed to expose
framing cavities in the thermal envelope,
those cavities must be filled with insulation
installed to Grade I quality standard
(ICC/RESNET 301).
Ordinance 1, 2023
Batts/loose fill: Insulation shall be closely
fitted wiring, pipes, etc. and avoid
substantial gaps, voids or compression. No
more than 2% of the total insulated area
shall be compressed or contain gaps or
voids in the insulation. These areas shall
not be compressed more
than 3/4 inch.
General Electrical Requirements
Any areas affected by the renovation must be brought
up to the current electrical code including:
tamperproof receptacles (NEC 406.12),
ground-fault circuit interrupter protection (NEC 210.8),
arc-fault protection (NEC 210.12),
receptacle spacing (NEC 210.52) etc.
09/22/2023
jimp
APPLICATION ACCEPTED DATE: 2023-09-20 PERMIT NUMBER: 0116-2023-BRES
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 403 MIDLAND PARK PL UNIT:
PARCEL ID: 273707412719 LEGAL DESCRIPTION: MIDLAND PARK CONDO
OWNER: MACCRACKEN SCOTT R
PERMIT CONTRACTOR: GUILLONTA PROPERTY SERVICE INC
DESCRIPTION OF WORK Remove a 6x2 L wall in the kitchen to open it up. Replace countertops and cabinets. Replace wall with support
column
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? No
CLASS OF WORK Residential FIRE SPRINKLER TYPE
BUILDING TYPE (IRC) Townhouse REQUIRED SPECIAL
INSPECTIONS Other
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table
OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS Not sure TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? No
Based on the Engineers letter, before installation, a revised
engineering drawing must be submitted. The post and the beam
shall be protected per IBC 704 or constructed of heavy timber per
2304.11