Loading...
HomeMy WebLinkAboutFile Documents.1039 E Cooper Ave.0116-2023-BRES (6)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 09/18/2023 09/22/2023 jimp Type VA Construction Codes: 2021 IBC, 2021 IEBC, 2020 NEC, 2021 IPC READ THIS OR FAIL YOUR INSPECTION! Dropped Ceilings and Soffits beneath fire rated assemblies 2021 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. 1. Dropped Ceilings & Soffits: If dropped 1 ¾ inches or less, do one of the following: -Fill spaces with Class A material. -Fill spaces with inorganic or non-combustible material. -Fire block 8 feet in all directions. 2. Dropped Ceilings & Soffits: If dropped greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 3. Dropped Ceilings & Soffits below Heavy Timber T&G ceilings, do all of the following: -One layer 5/8” type X gypsum board directly attached with minimum level one finish. -Drop ceiling according to item 1 or 2 above as applicable. (City Policy) 100% of lamps in permanently installed light fixtures must be high efficacy - IECC R404.1 IF ROOF/CEILING IS FULLY EXPOSED: INSULATION REQUIRED If finish materials are removed to expose framing cavities or dropped ceilings are removed to expose areas where insulation can be installed in the thermal envelope, insulation must be installed: Residential: R-49 Commercial: R-60 Ordinance 1, 2023 IF FRAMING CAVITIES ARE EXPOSED: QUALITY INSULATION REQUIRED If finish materials are removed to expose framing cavities in the thermal envelope, those cavities must be filled with insulation installed to Grade I quality standard (ICC/RESNET 301). Ordinance 1, 2023 Batts/loose fill: Insulation shall be closely fitted wiring, pipes, etc. and avoid substantial gaps, voids or compression. No more than 2% of the total insulated area shall be compressed or contain gaps or voids in the insulation. These areas shall not be compressed more than 3/4 inch. General Electrical Requirements Any areas affected by the renovation must be brought up to the current electrical code including: tamperproof receptacles (NEC 406.12), ground-fault circuit interrupter protection (NEC 210.8), arc-fault protection (NEC 210.12), receptacle spacing (NEC 210.52) etc. 09/22/2023 jimp APPLICATION ACCEPTED DATE: 2023-09-20 PERMIT NUMBER: 0116-2023-BRES COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 403 MIDLAND PARK PL UNIT: PARCEL ID: 273707412719 LEGAL DESCRIPTION: MIDLAND PARK CONDO OWNER: MACCRACKEN SCOTT R PERMIT CONTRACTOR: GUILLONTA PROPERTY SERVICE INC DESCRIPTION OF WORK Remove a 6x2 L wall in the kitchen to open it up. Replace countertops and cabinets. Replace wall with support column USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? No CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE (IRC) Townhouse REQUIRED SPECIAL INSPECTIONS Other CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS Not sure TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? No Based on the Engineers letter, before installation, a revised engineering drawing must be submitted. The post and the beam shall be protected per IBC 704 or constructed of heavy timber per 2304.11