Loading...
HomeMy WebLinkAboutFile Documents.406 E Hopkins Ave.0051-2023-BCOM (3) GRADE Christian Dior Temp Store -Aspen Building Department Plan Review Responses Permit No.: 0051-2023-BCOM Submitted 10.24.2023 Project Information: Address: 406 E. Hopkins Avenue,Space A2 City,State,Zip: Aspen, CO 81611 Contact: Architect: GRADE Address: 180 Varick Street Suite 916 City,State,Zip: New York, NY 10014 Phone: (212) 645-9113 GRADE respectfully submits the following information and responses to the plan review comments from 10/16/2023: Comment: 1. Sheet T-004.00 - DIMENSION THE OVERLAP WITH THE TURN RADIUS AND BENCH CORNER TO SHOW YOU ARE NOT EXCEEDING TOE CLEARANCE ALLOWANCES UNDER THE BENCH FOR TURNING PURPOSES. Response: Both the allowable overlap and actual overlap are dimensioned to show the turning radius is in compliance. The revision is clouded on sheet T-004.00. Comment: 2. PROVIDE A SIGNED AND STAMPED STRUCTURAL VERIFICATION LETTER FOR THE PROPOSED DEMO OR EXPLICITYLY CALL OUT PARTITIONS BEING REMOVED AS NON-STRUCTURAL ON A SHEET YOU STAMP AND SIGN.SOMEONE NEEDS TO TAKE ACCOUNTABILITY FOR ASSESSING WHETHER THESE WALLS ARE STRUCTURAL. Response: The walls scheduled for demolition have been probed and the AOR confirms none of the removed walls shown on the demolition plan are load bearing. A note stating as such is clouded on the signed and sealed sheet DM-100.00. In addition, a demo RCP has been added showing the recessed ceiling lights that will need to be removed to address the COMCheck comment. Regards, Andrew Mattessich GRADE ARCHITECTURE DPC, 180 VARICK STREET, SUITE 916- NEW YORK, NY 10014 RECEIVED T: 212-645-9113- F: 212-645-9982-GRADENYC.COM 10/2 6/2 0 2 3 ASPEN BUILDING DEPARTMENT