File Documents.710 N 3rd St.0094-2023-BROF (7)
XL-TRACE nv'ent RAYCHEM SELF-REGULATING HEATING CABLE FOR PIPE F ' PROTECTION AND FLOW MAINTENANCE Heating cable construction PRODUCT OVERVIEW nVent RAYCHEM XL-Trace is designed for pipe freeze protection and flow maintenance in the following applications: • Freeze protection of general water piping Modified polyolefin(-CR) (aboveground and buried) I or fluoropolymer(-CT), outerjacket • Freeze protection of fire sprinkler system piping, �-�� 'il►u=- including sprinklers Tinned copper braid • Flow maintenance of greasy waste lines Modified polyolefin inner jacket (aboveground and buried) Self-regulating conductive core • Flow maintenance of fuel lines(aboveground) NirkPl-nlatarl rnnnar hi is wire The heating element in the XL-Trace heating cable consists of a continuous core of conductive polymer extruded between two copper bus wires.The XL-Trace heating cable regulates its power output in response to pipe temperature changes.This self-regulating technology allows XL-Trace heating cable to be overlapped or installed on plastic pipes without overheating. Low total installed cost The XL-Trace heating cable's parallel circuitry allows it to be cut to the exact length required,with no wasted cable. Its flexibility allows it to be wrapped around complex fittings and valves. All of these characteristics simplify and streamline the design of a heat-tracing system. Installation is quick and simple. Low total operating cost Building operators are assured of optimal energy efficiency 10 and low maintenance costs when an XL-Trace system is specified. YEAR Product The same features that make an XL-Trace system easy to install the first time also simplify additions or changes to the system during building renovations. For additional information,contact your nVent representative or call (800)545-6258. Catalog Number 5XL1-CR/CT 5XL2-CR/CT 8XL1-CR/CT 8XL2-CR/CT 12XL2-CR/CT Voltage 120 V 208-277 V 120 V 208-277 V 208-277 V Maximum Operating Temperature 150°F(65°C) 150°F(65°C) 150°F(65°C) 150°F(65°C) 150°F(65°C) Maximum Exposure Temperature 150°F(65°C) 150°F(65°C) 150°F(65°C) 150°F(65°C) 185°F (85°C)' Minimum Installation Temperature 0°F(-18°C) 0°F(-18°C) 0°F(-18°C) 0°F(-18°C) 0°F(-18°C) Minimum Bend Radius 1/2 in(12 mm) 1/2 in(12 mm) 1/2 in(12 mm) 1/2 in(12 mm) 1/2 in(12 mm) When the design requires 185°F(85°C)exposure temperature,all connections must be installed off the pipe. RECEIVED 09/07/2023p Raychem-DS-H51349-XLTracePipeFreeze-EN-1903 nVentAS RE BUILDING DEPARTMENT MAXIMUM CIRCUIT LENGTH IN FEET 40°F/110°F Maintain* Start-up CB 5XL1 8XL1 5XL2 8XL2 12XL2 temperature size (°F) (A) 120 V 120 V 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 V -20°F 15 101 76 174 178 183 131 138 146 111 114 117 20 134 101 232 237 245 175 184 194 148 151 156 30 201 151 349 356 367 262 276 291 223 227 234 40 270 201 465 474 478 349 368 388 297 303 312 0°F 15 115 86 199 203 209 149 157 166 120 122 126 20 153 115 265 271 279 199 209 221 160 163 168 30 230 172 398 406 419 298 314 331 239 244 252 40 270 210 470 490 530 370/399 390/420 420/443 319 326 336 20°F 15 134 100 232 237 244 173 182 192 126 129 133 20 178 133 309 315 325 231 243 257 169 172 177 30 270 200 464 473 488 346 365 385 253 258 266 40 270 210 470 490 530 370/462 390/486 420/513 340/349 344 355 40°F 15 160 119 278 283 292 206 217 229 142 145 150 20 214 159 370 378 390 275 290 306 190 194 200 30 270 210 470 490 530 370/416 390/438 420/462 285 291 300 40 270 210 470 490 530 370/554 390/584 420/616 340/398 360/406 380/419 50°F 15 - - - - - 228 240 254 152 155 160 (buried) 20 - - - - - 304 320 338 203 207 213 30 - - - - - 457 481 507 304 310 320 40 - - - - - 609 641 676 405 414 427 65°F 15 - - - - - 272 286 302 169 172 178 (indoors 20 - - - - - 362 381 402 225 230 237 grease) 30 - - - - - 543 572 603 338 345 356 40 - - - - - 610 660 720 � 431 460 490 *When maximum circuit length is listed in: - black type,the value is for applications with a 40°F maintain - red type,the value is for applications with a 110°F maintain RECEIVED 09/07/2023 Raychem-DS-H51349-XLTracePipeFreeze-EN-1903 nVentA'u�1R EN BUILDING DEPARTMENT MAXIMUM CIRCUIT LENGTH IN METERS 4°C/43°C Maintain* Start-up 5XL1 8XL1 5XL2 I 8XL2 12XL2 temperature CB size (°C) (A) 120 V 120 V 208 V 240 V 277 V 1 208 V 240 V 277 V 208 V 240 V 277 V -29°C 15 31 23 53 54 56 40 42 44 34 35 36 20 41 31 71 72 75 53 56 59 45 46 48 30 61 46 106 108 112 80 84 89 68 69 71 40 82 61 142 145 149 106 112 118 90 92 95 -18°C 15 35 26 61 62 64 45 48 51 36 37 38 20 47 35 81 83 85 61 64 67 49 50 51 30 70 52 121 124 128 91 96 101 73 74 77 40 82 64 143 149 162 113/122 119/128 128/135 97 99 102 -7°C 15 41 31 71 72 74 53 56 59 39 39 41 20 54 41 94 96 99 70 74 78 51 52 54 30 82 61 141 144 149 106 111 117 77 79 81 40 82 64 143 149 162 113/141 119/148 128/156 104/106 105 108 4°C 15 49 36 85 86 89 63 66 70 43 44 46 20 65 48 113 115 119 84 88 93 58 59 61 30 82 64 143 149 162 113/127 119/134 128/141 87 89 91 40 82 64 143 149 162 113/169 119/178 128/188 104/121 110/124 116/128 10°C 15 - - - - - 70 73 77 46 47 49 (buried 20 - - - - - 93 98 103 62 63 65 grease) 30 - - - - - 139 147 155 93 95 98 40 - - - - - 186 195 206 124 126 130 18°C 15 - - - - - 83 87 92 52 53 54 (indoors 20 - - - - - 110 116 123 69 70 72 grease) 30 - - - - - 166 174 184 103 105 108 40 - - - - - 186 201 220 131 140 149 *When maximum circuit length is listed in: - black type,the value is for applications with a 40°F maintain - red type,the value is for applications with a 110°F maintain NOMINAL POWER OUTPUT ON METAL PIPES AT 120 V/208 V 14 12 !C� ----■ 0 5XL1-CR and 5XL1-CT(120 V) $ 10 . = 5XL2-CR and 5XL2-CT(208 V) 3 6 ,, i_ _ �_ es, 8XL1-CR and 8XL1-CT(120 V) 0 O. __ === 8XL2-CR and 8XL2-CT(208 V) ml•Millisii="1-10110111�� Q 12XL2-CR and 12XL2-CT(208 V) 0 iiiIM 30 40 50 60 70 80 90 100 110 120 130 °F (-1) (5) (10) (15) (21) (27) (32) (38) (43) (49) (54) (°C) Pipe temperature RECEIVED 09/07/2023�+DC Raychem-DS-H51349-XLTracePipeFreeze-EN-1903 nVentA'o�1R LN BUILDING DEPARTMENT BUS WIRES 16 AWG nickel-plated copper BRAID/OUTER JACKET Tinned-copper braid with modified polyolefin jacket(-CR)or fluoropolymer jacket(-CT). DIMENSIONS 5XL and 8XL 12XL Maximum width 0.56 in(14 mm) 0.62 in(16 mm) Maximum thickness 0.24 in(6 mm) 0.24 in(6 mm) NOMINAL WEIGHT 92 lb/1000 ft 104 lb/1000 ft CONNECTION KITS nVent RAYCHEM RayClic or FTC connection kits must be used with XL-Trace heating cables. Refer to the Pipe Freeze Protection and Flow Maintenance Design Guide(H55838)for proper connection kit selection. APPROVALS UL 718K Pipe Heating Cable SP® LISTED C W US 41) nacxoveo SP@ u$ _W Refer to the Pipe Freeze Protection and Flow Maintenance Design Guide(H55838) and the Fire Sprinkler Freeze Protections Design Guide(H58489)for specific product approval details. GROUND-FAULT PROTECTION To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed,and to comply with the requirements of nVent,agency certifications,and national electrical codes,ground-fault equipment protection must be used on each heating cable branch circuit.Arcing may not be stopped by conventional circuit protection. Many nVent RAYCHEM control and monitoring systems meet the ground-fault protection requirement. RECEIVED 09// D0�+7/2��023 Raychem-DS-H51349-XLTracePipeFreeze-EN-1903 nVent/C'0'0711 N BUILDING DEPARTMENT North America Tel +1.800.545.6258 Fax +1.800.527.5703 thermal.info@nvent.com nee nt Our powerful portfolio of brands: nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER 09/07/2023 02019 nVent.All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates.All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. Raychem-DS-H51349-XLTracePipeFreeze-EN-1903 5