HomeMy WebLinkAboutFile Documents.211 W Hopkins Ave.0078-2021-BRES (24) HealthSafe . NSPECTIO NS HealthSafe Inspections Inc 390 Apple Drive Basalt CO 81621 970-920-2100 Jim Baker CDPHE Asbestos Building Inspector#13437 Ben Baker CDPHE Asbestos Building Inspector#25863 ASBESTOS REPORT DATE 03/01/2021 CLIENT Matt Joblon PROPERTY ADDRESS of INSPECTION 211 West Hopkins Avenue,Aspen, Colorado 81611 rr,, e Air 21i r Aix _ 4 • 40, RECEIVED 1 05/21/2021 ASPEN BUILDING DEPARTMENT CLIENT BACKGROUND & PLANS The Client, Matt Joblon, is planning to move the above referenced single-family cabin, which will have impacts of disturbance, detachment, deconstruction, demolition and disposal (5D) of drywall, flooring and roofing building materials, of which some are suspect asbestos containing materials (ACM) or suspect asbestos containing building materials (ACBM). Prior to 5D, Matt Joblon is required to have an asbestos inspection by a State of Colorado CDPHE certified asbestos inspector who will collect bulk samples of the suspect ACM/ACBM and have those samples analyzed at a certified laboratory for asbestos content. Matt Joblon hired HealthSafe Inspections, Inc. (hereinafter, HealthSafe) to perform an unlimited asbestos inspection for the above referenced single-family cabin. VISUAL INSPECTION & LABORATORY FINDINGS An inspection was conducted by Ben Baker of HealthSafe on Wednesday, February 17, 2021 with tenants present during the initial survey, inspection and sample collecting.All suspect ACM/ACBM were identified by homogenous materials and sampled randomly respective to the scope of those materials slated for 5D.The suspect ACM/ACBM collected and analyzed by EPA 600 Method PLM analysis are the following: 1. Flat Finish Surfacing Texture, a homogeneous trowel-applied surfacing material/texture [samples 1-3: FF-1,2,3], collected randomly from the SE bathroom north shower wall upper east, center and lower west, respectively, using the AHERA random sampling grid# 15. This surfacing material/texture is on the partition wall for the SE bathroom shower. The estimated impact area of 5D is more than 10 sf, but less than 1,000 sf(±50 sf), requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: NONE DETECTED. 2. Drywall System, a homogeneous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [samples 4- 5: J-1,2], collected from the SE bathroom center taped joint in the center and west side, respectively. These composite layered taped and joint compounded drywall materials are on the partition wall in the SE bathroom with a flat finish applied surfacing material/texture. The estimated impact area of 5D is more than 10 sf, but less than 1,000 sf(±50 sf), requiring a minimum of at least two composite core samples of all layers. The PLM analytical estimated results: NONE DETECTED. 3. Bathroom Sheet Vinyl, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 6-7: RR-SV 1,2], collected from the north bathroom NE corner and the SE bathroom under the vanity, respectively. The PLM analytical estimated results: NONE DETECTED. 4. Kitchen and Entry Sheet Vinyl, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 8-9: KIT-SV 1,2], collected from the entry SE corner and kitchen NE area, respectively. The PLM analytical estimated results: NONE DETECTED. RECEIVED 2 05/21/2021 ASPEN BUILDING DEPARTMENT 5. Roofing Tar Paper, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 10-11: TP-1,2], collected from the entry roof in the center and cabin roof NE corner, respectively. The PLM analytical estimated results: NONE DETECTED. A total of 11 suspect homogeneous ACM/ACBM bulk samples were collected and 11 samples were analyzed. The bulk samples were analyzed by EPA 600 PLM analytical methods by a NVLAP accredited laboratory in accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers. There is NO asbestos in all 11 samples. See supporting Hayes Microbial Consulting, Inc. data report#21005480 1. HEALTHSAFE CONCLUSIONS • There is NO asbestos in any of the suspect building materials slated for 5D in this cabin relocation project. NO asbestos abatement will be required for any of the building materials.All building waste and debris can be disposed of in any landfill which accepts normal, non-hazardous building waste. Sincerely Submitted, Ben Baker RECEIVED 3 05/21/2021 ASPEN BUILDING DEPARTMENT COLORADO & FEDERAL ASBESTOS REGULATIONS SUMMARY Regulation No. 8 Part B—Asbestos of the Colorado Department of Public Health and Environment(CDPHE),Air Quality Control Commission requires a State-certified Asbestos Building Inspector to inspect and collect bulk samples of all suspect asbestos containing materials (ACM) or suspect asbestos containing building materials (ACBM) prior to their disturbance, removal or demolition and disposal. The suspect materials shall be analyzed by a NVLAP accredited laboratory by polarized light microscopy(PLM) using EPA 600 analytical method.A material which is estimated to contain more than 1% asbestos is classified as ACM/ACBM and regulated by the State and Federal governments.Any friable (able to crush or reduce to powder by finger pressure) asbestos with trace amounts of asbestos fibers or less than 1%must be point-counted using EPA 400 analytical method to prove that it is indeed less than 1%; if not, it must be classified as ACM/ACBM and shall be treated as a State and Federal regulated material.Any friable asbestos containing material (greater than 1% asbestos concentration) or ACM/ACBM that could be rendered friable during its removal or demolition and disposal shall require an asbestos abatement by a certified asbestos abatement contractor to remove and dispose of the material(s). A Colorado State (CDPHE) issued asbestos abatement permit is required for the following trigger levels of ACM/ACBM: 1. Residential buildings of four or fewer units--if more than 32 square feet of any surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing materials/textures, acoustic sprays,joint compounds,plaster, etc.), 50 feet of asbestos covered or asbestos insulated pipe or any material which would fill a 55-gallon drum is going to be disturbed, removed or disposed of, an asbestos abatement permit is required. 2. Residential complexes with more than four residential units, public access areas to a residential building, commercial and retail buildings, public and civic buildings, industrial buildings--if more than 160 square feet of surfacing materials, 260 linear feet or more than 35 cubic feet(NESHAP) or 55-gallon drum(CDPHE) of suspect ACM/ACBM is going to be disturbed, removed or disposed of, an asbestos abatement permit is required under NESHAP and by the CDPHE. See note below on OSHA. The regulations require an absolute minimum of 3 samples (EPA suggests 9)per homogenous suspect surfacing and TSI materials and an absolute minimum of 2 samples of homogenous miscellaneous materials or any number of"samples sufficient to determine whether a material is ACM" (Reg8.IV.D.3). More samples are required based on surface area or volume. These are minimums; the asbestos building inspector has the field responsibility to determine homogenous materials and the number of samples to collect per material; more than the minimum number of samples may be necessary at the discretion of the inspector.An assessment of friability and functional space conditions of the materials are also the inspector's field responsibilities. RECEIVED 4 05/21/2021 ASPEN BUILDING DEPARTMENT OSHA compliance is required for all employers and employees no matter the quantity of asbestos present with strict regulations regarding 10 sf or more of TSI or friable surfacing materials, and therefore it does not matter what the quantity or State trigger levels are: all suspect ACM/ACBM shall be inspected and tested for asbestos prior to their disturbance, removal and disposal for worker protection and safety. See EPA 40 CFR 763.121 Worker Protection Rule, OSHA 29 CFR 1910.134 Respirator Protection Standard, OSHA 29 CFR 1910.1001 General Industry Standard and OSHA 29 CFR 1926.1101 Construction Standard regulations when dealing with asbestos hazards. Note: County or City regulations may be more stringent. RECEIVED 5 05/21/2021 ASPEN BUILDING DEPARTMENT a% HAYES MICROBIAL CONSULTING #21005480 Analysis Report prepared for We would like to thank you for trusting Hayes Microbial for your analytical needs! We received 11 samples by FedEx in good condition for this project on February 22nd,2021. HealthSafe The results in this analysis pertain only to this job, collected on the stated date, and should not be used Inspections in the interpretation of any other job. This report may not be duplicated, except in full,without the written consent of Hayes Microbial Consulting, LLC.. 390 Apple Drive This laboratory bears no responsibility for sample collection activities, analytical method limitations,or Basalt, CO 81621 your use of the test results. Interpretation and use of test results are your responsibility. Any reference to Phone: (970) 920-2100 health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial. In no event, shall Hayes Microbial or any of its employees be liable for lost profits or any special, incidental or consequential damages arising out of the use of these test results. Joblan 211 W Hopkins Ave 44( nAspen, CO 81611 *A....0 Collected: February 17, 2021 Steve Hayes,BSMT(ASCP) Received: February 22, 2021 Laboratory Director Reported: March 1, 2021 Hayes Microbial Consulting,LLC. ciED ST,4 �07 /AL�o,4,,001 w 1 tia , 1 , DPH � \+T CnnuDpme 4C pROjE Health RECEIVED EPA Laboratory ID: VA01419 Lab ID: #188863 DPH License: #PH-0198 05/21/2021 Hayes Microbial Consulting,LLC. 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804) 562-3435 contact@hayesmicrobial.com Page: 1 of 4 ASPEN BUILDING DEPARTMENT Ben Baker #21005480 HealthSafe Inspections Joblan 390 Apple Drive 211 W Hopkins Ave Basalt,Co 81621 Aspen,co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 1 FF-1 Brittle/White None Detected 2 FF-2 Brittle/White None Detected 3 FF-3 Brittle/White None Detected 4 J-1 Drywall/White/Brown 12°%o Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 12°%o Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 5 J-2 Drywall/White/Brown 12°%o Cellulose Fibers None Detected Joint Compound/White None Detected Drywall/Joint Compound/White/Brown 12°%o Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 6 RR-SV-1 Vinyl Tile/White None Detected Adhesive/Yellow None Detected Collected:Feb 17,2021 Received: Feb 22,2021 Reported: Marl,2021 RECEIVED 0 H AY E S Project Analyst: /� Date Reviewed By: 1 rD5e/2 1 2 0 2 1 Renaldo Drakes, U 03 - 01 2021 Geepha Jacob, ti . VS4 V03/-01 -2021 MICROBIAL CONSULTING JJJL , 3005 East Boundary errace, uite F. Midlothian,VA.23112 (804)562-3435 contact@hayesmicrobial.com BUILDING DEPARTMENT Ben Baker #21005480 HealthSafe Inspections Joblan 390 Apple Drive 211 W Hopkins Ave Basalt,Co 81621 Aspen,co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 7 RR-SV-2 Vinyl Tile/White None Detected Adhesive/Yellow None Detected 8 KIT-SV-1 Vinyl Tile/Gray None Detected Adhesive/Yellow None Detected 9 KIT-SV-2 Vinyl Tile/Gray None Detected Adhesive/Yellow None Detected 10 TP-1 Fibrous/Black 65%Cellulose Fibers None Detected 11 TP-2 Fibrous/Black 65%Cellulose Fibers None Detected Collected:Feb 17,2021 Received: Feb 22,2021 Reported: Marl,2021 RECEIVED 0 H AY E S Project Analyst: /� Date Reviewed By: 1 rD�e/2 1 2 0 2 1 Renaldo Drakes, U 03 - 01 2021 Geepha Jacob, ti . VS4 V03/-01 -2021 MICROBIAL CONSULTING JJJL , 3005 East Boundary errace, uite F. Midlothian,VA.23112 (804)562-3435 contact@hayesmicrobial.com BUILDING DFERTI1�Et4T Ben Baker #21005480 HealthSafe Inspections Joblan 390 Apple Drive 211 W Hopkins Ave Basalt,CO 81621 Aspen,co 81611 Asbestos Analysis Information (970) 920-2100 Analysis Details All samples were received in acceptable condition unless otherwise noted on the report.This report must not be used by the client to claim product certification, approval,or endorsement by AIHA,NIST,NVLAP,NY ELAP,or any agency.The results relate only to the items tested. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines. PLM Analysis All Polarized Light Microscopy(PLM) results include an inherent uncertainty of measurement associated with estimating percentages by PLM. Materials with interfering matrix,low asbestos content,or small fiber size may require additional analysis via TEM Analysis. TEM Analysis Analysis by TEM is capable of providing positive identification of asbestos type(s) and semi-quantitation of asbestos content. Definitions 'None Detected'-Below the detected reporting limit of 1%unless point counting is performed,then the detected reporting limit is .25%. New York ELAP Per NY ELAP198.6(NOB),TEM is the only reliable method to declare an NOB material as Non-Asbestos Containing. Any NY ELAP samples that are subcontracted to another laboratory will display the name and ELAP Lab Identification number in the report page heading of those samples.The original report provided to Hayes Microbial Consulting is available upon request. RECEIVED H AY E S 05/21/2021 MICROBIAL CONSULTING 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804) 562-3435 contact@a hayesmicrobial.com C +4 of BUILDINGASP DEPARTMENT +yv.r r�`v,••'L. !^' ;'.�1•:�♦ , ;k;1 �1�1.•VV�'• 11i•�.i-r-►�•.. !fry' •�11..'r•►1�• •••ti �ri7i• . ••� �1P 1�►Y1'••.. l--. � .i�.�.;.^ ��l %gip••?at. \�, ^ � �i1 ?�' '�����—/.�i/.,•�;:..::\��'L �•iI ,•\�� � —•�.�i%' 7�?'.V~�i1'�"J .$ %1/$4.-.tiO,k\.r .t,l',9%%:i .1 N •,/ •/, ;p .��Z4 \1,,.....0 ,/,/./. 1�.. \ 1 . 4 - h . ,, r b . 1,r ../9b, . �• f• % •%'.:�b M a I''_.\ .►t` .f �% '► % O b �C\.. ./.f .%% A. „'b \►'�\, .•.1 .I,1./\li%' � 'b.\�1. ►/.r I,/ :v 1 1 r r 11„1r. /N 1. • i Pa, ' ..'.� ••♦. .4,„'''i/i./ ,e1Ve.,.\' 411..1,11,'0:`/.•o: .fD�,„' . j1/:1.1p ..IV, ym t i i}t.' AA' � ym -V A' - / }'�. ..1 .-' =•,� 1�). � •.�1�,J. it '�I�. x ti — . • .' .,. 1 ..,,,,, 1. ;(,1,,,,,,‘, ,A,,,1,.t,,, ,.1 1, it , . , . • . . r S,V.�+�1 ,1 .tt.ti,tl. is'..,rV, il. rJ, .b. ,H,Y„�1'.,,tj,lJ,.�,zj,H;�1,V,J,V,tr.n,1 .tt,U•,11, b.tr'r-•$1,44,;:%. ., ca. rill 94 f 2= r...i A.t.9.77•r; :::.„'":-.,,,:s,•1,:=::. Il— t f•.�=m 3 � w p CI. (... �. -� ono O r-tili 4' _ �r EI = to y •. .o if , 1 N C Oo ' ^ jfl \ \ `O 1 r.r• r. ...f rC .. -.--., .,_ . : , �",� � � r* N N - rd y p F•O Its •. = :3 i r �— —t •—* • �� ;AI'''. 4•Cri.:70. ( ------- - fy, 1,., D /� _ , pC�'Q :3(1,4p.r:;... „,- 4 . ..,"...,.. ....,..•., S R hI ..,. ..... ._,......e. ,., > , ..., . cD C-A.C:Z -1;;'::e;.• __. g , —1..) 0 ..,-- ..:.°4:-..-.F:- +. ; 73 --, _ x "'% . • ( " 7Q _ • .•••` j ? ' •; �t t S.t W fi 4 1 ! 11 1 1 1'. l ? A A S. lAl xti +L u�a,1..1: .rvi', li:�..tax u > > . feA oi, ,, -A , If �� r T � T 8s*� v T Tottiw:ii:1-%.,.....,.,4*64,_� �,y.. .1,. r. •:::�A•J. .r,;tr41 , •�:621:. :0071.,. . .-:•• ..•.• ,;',,.40, ,-:.. 1-- '•1...v.01.: .••..6,1..,. .:1,4:jli �,, : ;:• _./a1 4vo �. ,`, , IHIb• •i 1 4 O • �: 1 r � f ...11.0.40., .• �a \ Y •1.1 f t •/•'• `� 1. d /' .1r1r1. r• V v- /1•�•1 r� �t \ If Q/ •/li/►•.• \�` p/ •/lifr.�,•^\.�, LN tii'. aa,,C�t�:,,,r;lr i��z a 1u1 s,, /�,!ri'. ��,� .; ,; /n.�ri.__ add /r�/ �Zi, rr,.:!�n�%•I 4N1 \Z• t r•.i.... ', . y' �F . .s...,, :.......,,.. BUILDING 6EPA�TMENT /::J�1t�.%,�,• •i i'1�1e1t�•1.1•r*, i+1e�11tit1•• \ti .•t�t���t�•*•• a i t t�+•1t1ti•• �tf tttl tlttt�. \ ••+p+�11�t�tt•• sI ••01 t •gee•4•• \, •'O t�* �•�.J44•jl%°%� q 4►i11►+11.01 1. :'►1Yi14•••,11%l•/. :.��1i►•►11111111oi.. ,.i41:*:•�••••• 0;' .1,41**,jljl°6' iiiN :4j11,44Piii 4*'4.j114%0 1. 4 i41it�►►1•4•$/0i`, R%tk ��t.....i +•���►�Il0/j/fi,.eI%tkill•00+100•0//0, gti4ti:��/►11114i°0444 411411►�►/1410Ole..�\.44,4f►0►111/0404i..\y'.44 ►►/0001:01.-.sW1111i�►/O0,0#00;..'y\\'I4N,11O#,0/f/i.•,wq%,1o►1►O,0i1e,p,,,A11:,4:4�1...�. ►O'�i>�I(0j�,•A�41111iiN/f/1i/�/'\.�14►11H104/j4 r\.\114Y11,111#11�/-17'..,T410011II#1Il/li-9,.. \1,1110/H10 I11/li 1,14 ,,41/.,1410,0 IiG% \�I�W1444:0//'%`��\\`.1 04,..11,,,ifft:I INVI4., Ott, ►..�'t ' 14,\\\tV,1044� /if�\�0, q,,..: i1. /1/���\iVe:4.44..°//A\,a'r,4ei.1•i1•;,4� !J/n\;,,,11 ii44,,i %f/^\%\,!',F;ii i6' /1/�\`\'I!i;i•,iiS yG ,/f^\,\ . �,,,,•,1. 4i 14A' , l"�.:�.V . 4. .:,,. .%$4$.N\iy\• ,. 'I//r^%1V '''� ` /°/0°,n%1%`o,:,t:N,: j/ij/^4 1 ',ta;,� r//j0h\k' •y:i0�,,; jff�/eN;V , ;.,,._f/fi5.;% :....;t. 1 41---1,1; , %/lts�\Q . `"�. �'.:, \yyy\\ !//i \yyN\ fi/ \yyyy\ //li: '\y\yy\ /0/ ��yyN\s f/f, ��yy>> f//i �yyyy\ f/ f y / ,.v ����t ' •i�1C'''': aY •Y �Y V 4 Y �l:16 V Y� Y Y Y Y Y� Y Y Y W i i� f 1'tt• r „ /.•: . '� -SJI,•U;%veI,JI� I;UI U;JJI,+UI4.01 it�JU..e' L,�LJ,111,+U1,1 lii of ... .$'IJJ.....I�j J,(UI....UJ.J{l,IUl,J ifU.7---(lJ1-4,-,;UI, liul,JU�,UJ,J-AIL . ?1 �j►Yi' vv\ieivvv'�'i�vvvvvv C!►.�v+l..� v v vvv`v '•� CC ?b: * J�5.. siv (t �I��:: : \\r:•0 ¢..:� ii� ' '� i Colorado Department ...?'• ay of Public Health (K •.' ' 1� and Environment == -i) (( •'- - ice; _.: ;.:_==_ ;) ASBESTOS (« f CERTIFICATION* � '= i_.:,: fit==v\ ��) tj'^ �7,--,.. ..� '�) This certifies that = _-__` ••,/r ») Benjamin L Baker « o,"-",r_: `-, �i) ((c . _ :. Py= =i _ =0 Certification No.. 25863 ac .,\'''''''' )) has met the requirements of 25-7-507, C.R.S. and Air Quality Control ((C:':::;;)»iY;. 4 ,i )) Commission Regulation No. 8, Part B, and is hereby certified by theCitt =` : :z =''�' H state of Colorado in the following discipline: Kc = _ =~ , - ai) w > �) Building Inspector* (c >�»>;. ��_ j) Issued: September 08, 2020 {ic r :.,; ow!' A, ?)) Expires: September 25, 2021 (( " = • =.:•d, sue/ s, ) CC''; : .o ;•�%;=%= __ -4) '''This certificate is valid only with the possession of a (CC = Z4: ',:' .) current Division-approved training course certification ((� _- :,• i.. v — ((C : -:ii / •,!f��'J� , in the discipline specified above. -,4,141, . .�) Authorized L CD Representative ((C �`si�*�t.t~• • �)) SEAL «-1 ;iii%%:. ,.� ice.. CV t=-4-:-..-7'N*Tt-5 ryr► r^a� r, ter► ��� Fr►r►r►r► (C -�, •i.� i -_ '•u.�J�rt�IRII II'lanI� ;�etriti nle, IRItaltRIPIITI nJ►r„ .�I ���r 11F1:llr;I.tat .11FMMI MIVA TJhn �1 tll ln�J � un im,..,14;r *:.* ,,,,,, 4. ..- 1' ,-..- CAI :;;;; %�A .: ,% . �,..A •6a�%�\\` /°I%1,77i.' \\�'✓I%°,Jl \\`,,,gp,„,ii:. \,\\\I;::::,:'P; �\0;1i°,l'.'ii \\rI k;°/ .�4,' x,tAki'/°III1. ,Y. \ %111A,•.;::::, \ t\''41f,iii+• ►1\V/;f^,•i,,;, 14Nv/;ir!;•;��,,•;,r.,4$+ , 0_,1'4'��0�%�r \$4. 0i'','�;4';����:\i�yv/.�'�.•;�';;;,. \4N /;r/irq ',5�r,.,\4�\V1�1��,�.'•w�•�e•: ��ri1..,•;•'�i•�. \44\V/err--����+ ,'•«��:--.1\1yr1,,,,,I',;r• ,1y,:\\\vrr.:��;;W:•;';'10 ,\1V/r„1,i,/� l�•, 1�. V gq,1,;;";'g'iloV :14yy,f,,,;/j•::;',: „tkol;�''.,•• �trl V.IS,rs," Nir \t.' Vrrs1,%.��.�,,y,,kr,41 ;;;;;i�Si`. '.•. 1111\ 1b(c1ii11PIy��11111y1,*;`;',At ey":,111\\strl1i/10,V0%llllllt*4%* 111jP1Pi0f11111 ez.v.•1i/41,6,V 1' 11y'`\Zr/11r11i 111\\.Y�' f�° ilah`.i0r1 •11`st„'1111l•li'::�c 't%•�1/11�111ii'���R/ill/I/l11/1'1i1►�\i�!�t/i/11►j/11�11\4!\� `(i jij111/11.11+1�111\i`�,/t11'•1/1111/1�►\1\i` d�si/Ij►•►+�11\1\i'`i/�i,i1,► �{{I��li'�,'"r",' li-- 11/,vi%�i►1j1�1/11�+,�b,i:I�;•jl./11 1"�..�.� �Ct:•�•�1•'•i ttet�:e. �1•',i ••`t•1��•�i.4 •'•i •:mot/*.t��1*�' \ '1�.1�M•4-1°' `•:•'�•�.te•I•'�•, •/•i/,1/t/•�i' 4 �i ►1i ':4•,•••••-�11* • •i 4-•••-•�- AS'L BUILDING DEPARTMENT