HomeMy WebLinkAboutFile Documents.610 S West End St.0138-2021-BRES (5) HealthSa f e
I NSPECTIO NS
HealthSafe Inspections Inc
390 Apple Drive
Basalt CO 81621
970-920-2100
Jim Baker CDPHE Asbestos Building Inspector#13437
Ben Baker CDPHE Asbestos Building Inspector#25863
ASBESTOS REPORT
DATE
10/29/2020
CLIENT
Chris Desino
PROPERTY ADDRESS of INSPECTION
The Gant#K204
610 South West End Street,Aspen, Colorado 81611
.
tic
•
: THE GANT
e
ASPEN
610 S WEST ENO ST
CEIVED
1 11/09/2021
IV 4IIE n No2/28,2O22 J ASPEN
FORCOMITAWIACE
BUILDING DEPARTMENT
CLIENT BACKGROUND & PLANS
The Client, Chris Desino, is under contract to purchase the above referenced
condominium unit and is planning an interior renovation-remodel-demolition,which will
have impacts of disturbance, detachment, deconstruction, demolition and disposal
(5D) of drywall building materials, of which some are suspect asbestos containing
materials (ACM) or suspect asbestos containing building materials (ACBM). Prior to 5D,
Chris is required to have an asbestos inspection by a State of Colorado CDPHE certified
asbestos inspector who will collect bulk samples of the suspect ACM/ACBM and have
those samples analyzed at a certified laboratory for asbestos content. Chris Desino hired
HealthSafe Inspections, Inc. (hereinafter, HealthSafe) to perform an unlimited interior
asbestos inspection.
VISUAL INSPECTION & LABORATORY FINDINGS
An inspection was conducted by Ben Baker of HealthSafe on Monday, October 26, 2020
with the condominium vacant during the initial survey, inspection and sample collecting.
All suspect ACM/ACBM were identified by homogenous materials and sampled
randomly respective to the scope of those materials slated for 5D.The suspect
ACM/ACBM collected and analyzed by EPA 600 Method PLM analysis are the
following:
1. Skip Trowel Surfacing Texture, a homogeneous trowel-applied surfacing
material/texture [samples 1-5: ST-1,2,3,4,5], collected randomly from the living
room east wall south of the sliding doors next to the power outlet, entry south coat
closet west wall, laundry closet east wall, bathroom behind the toilet and kitchen
ceiling east of the north wall cabinets, respectively, using the AHERA random
sampling grid# 15. This surfacing material/texture is on the ceilings and walls of
the condominium interior. The estimated impact area of 5D is more than 1,000 sf,
but less than 5,000 sf(±1,800 sf),requiring a minimum of at least five
surfacing/texture material samples. The PLM analytical estimated results: NONE
DETECTED.
2. Drywall System Joint Compound: a homogeneous miscellaneous seam taping
compound requiring at least two samples [samples 6-7: JC-1,2], collected from
the laundry closet SW corner above the door and entry south coat closet SE
corner, respectively. This material is applied to the interior drywall system. The
PLM analytical estimated results: NONE DETECTED.
3. Drywall System, a homogeneous taped and joint compounded drywall system
(classified as a miscellaneous material as a complete integral system) [samples 8-
9: J-1,2], collected from the laundry closet SW corner above the door and entry
south coat closet SE corner, respectively. These composite layered taped and joint
compounded drywall materials are on the ceilings and walls of the condominium
interior with a skip trowel applied surfacing material/texture. The estimated
impact area of 5D is more than 1,000 sf,but less than 5,000 sf(±1,800 sf),
RECEIVED
2 11/09/2021
,,O2/28,2O229 ASPEN
FORCODttANKAICE
BUILDING DEPARTMENT
requiring a minimum of at least two composite core samples of all layers. The
PLM analytical estimated results: NONE DETECTED.
A total of 9 suspect homogeneous ACM/ACBM bulk samples were collected and 9
samples were analyzed. The bulk samples were analyzed by EPA 600 PLM analytical
methods by a NVLAP accredited laboratory in accordance with Colorado State
Regulation 8 for the presence of asbestos mineral fibers. There is NO asbestos in all 9
samples.
See supporting Hayes Microbial Consulting, Inc. data report#20039684 1.
HEALTHSAFE CONCLUSIONS
• There is NO asbestos in any of the suspect building materials slated for 5D in the
condominium interior. NO asbestos abatement will be required for any of these
building materials.All building waste and debris can be disposed of in any landfill
which accepts normal, non-hazardous building waste.
Sincerely Submitted,
Ben Baker
See 3a: .
RECEIVED
3 11/09/2021
n��4tL'
No2/28,2O229 ASPEN
FORCODttANKAICE
BUILDING DEPARTMENT
COLORADO & FEDERAL ASBESTOS REGULATIONS SUMMARY
Regulation No. 8 Part B—Asbestos of the Colorado Department of Public Health and
Environment(CDPHE),Air Quality Control Commission requires a State-certified
Asbestos Building Inspector to inspect and collect bulk samples of all suspect asbestos
containing materials (ACM) or suspect asbestos containing building materials (ACBM)
prior to their disturbance, removal or demolition and disposal. The suspect materials shall
be analyzed by a NVLAP accredited laboratory by polarized light microscopy(PLM)
using EPA 600 analytical method.A material which is estimated to contain more than 1%
asbestos is classified as ACM/ACBM and regulated by the State and Federal
governments.Any friable (able to crush or reduce to powder by finger pressure) asbestos
with trace amounts of asbestos fibers or less than 1%must be point-counted using EPA
400 analytical method to prove that it is indeed less than 1%; if not, it must be classified
as ACM/ACBM and shall be treated as a State and Federal regulated material.Any
friable asbestos containing material (greater than 1% asbestos concentration) or
ACM/ACBM that could be rendered friable during its removal or demolition and disposal
shall require an asbestos abatement by a certified asbestos abatement contractor to
remove and dispose of the material(s).
A Colorado State (CDPHE) issued asbestos abatement permit is required for the
following trigger levels of ACM/ACBM:
1. Residential buildings of four or fewer units--if more than 32 square feet of any
surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing
materials/textures, acoustic sprays,joint compounds,plaster, etc.), 50 feet of asbestos
covered or asbestos insulated pipe or any material which would fill a 55-gallon drum is
going to be disturbed, removed or disposed of, an asbestos abatement permit is required.
2. Residential complexes with more than four residential units, public access areas to a
residential building, commercial and retail buildings, public and civic buildings,
industrial buildings--if more than 160 square feet of surfacing materials, 260 linear feet
or more than 35 cubic feet(NESHAP) or 55-gallon drum(CDPHE) of suspect
ACM/ACBM is going to be disturbed, removed or disposed of, an asbestos abatement
permit is required under NESHAP and by the CDPHE. See note below on OSHA.
The regulations require an absolute minimum of 3 samples (EPA suggests 9)per
homogenous suspect surfacing and TSI materials and an absolute minimum of 2 samples
of homogenous miscellaneous materials or any number of"samples sufficient to
determine whether a material is ACM" (Reg8.IV.D.3). More samples are required based
on surface area or volume. These are minimums; the asbestos building inspector has the
field responsibility to determine homogenous materials and the number of samples to
collect per material; more than the minimum number of samples may be necessary at the
discretion of the inspector.An assessment of friability and functional space conditions of
the materials are also the inspector's field responsibilities. RECEIVED
4 11/09/2021
1)1
,,O2/28,2O229 ASPEN
FORCODttANKAICE
BUILDING DEPARTMENT
OSHA compliance is required for all employers and employees no matter the
quantity of asbestos present with strict regulations regarding 10 sf or more of TSI or
friable surfacing materials, and therefore it does not matter what the quantity or
State trigger levels are: all suspect ACM/ACBM shall be inspected and tested for
asbestos prior to their disturbance, removal and disposal for worker protection and
safety. See EPA 40 CFR 763.121 Worker Protection Rule, OSHA 29 CFR 1910.134
Respirator Protection Standard, OSHA 29 CFR 1910.1001 General Industry Standard and
OSHA 29 CFR 1926.1101 Construction Standard regulations when dealing with asbestos
hazards.
Note: County or City regulations may be more stringent.
RECEIVED
5 11/09/2021
No2/28,2O229 ASPEN
FORCODttANKAICE
BUILDING DEPARTMENT
4 H AY E S
MICROBIAL CONSULTING #20039684
Analysis Report prepared for We would like to thank you for trusting Hayes Microbial for your analytical needs!
We received 9 samples by FedEx in good condition for this project on October 27th, 2020.
HealthSafe
The results in this analysis pertain only to this job, collected on the stated date, and should not be used
Inspections in the interpretation of any other job. This report may not be duplicated, except in full,without the written
consent of Hayes Microbial Consulting, LLC..
390 Apple Drive This laboratory bears no responsibility for sample collection activities, analytical method limitations,or
Basalt, CO 81621
your use of the test results. Interpretation and use of test results are your responsibility. Any reference to
Phone: (970) 920-2100 health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial. In no event, shall
Hayes Microbial or any of its employees be liable for lost profits or any special, incidental or
consequential damages arising out of the use of these test results.
Chris Desino
The Ghant #K204
610 S West End St.
Aspen, CO 81611 44( n *„..6&_,..
Collected: October 26, 2020 Steve Hayes,BSMT(ASCP)
Received: October 27, 2020 Laboratory Director
Reported: October 29, 2020 Hayes Microbial Consulting,LLC.
‘00 ED STAT_
ii
J s /
AL'bo,,o \
w 1DPH
+T G� \ Connecticut Department
4C pROjE of tkot Health RECEIVED
EPA Laboratory ID: VA01419 Lab ID: #188863 DPH License: #PH-0198
11/09/2021
Hayes Microbial Consulting,LLC. 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804) 562-3435 contact@hayesmicrobial.com Page: 1 of 4
ASPEN
BUILDING DEPARTMENT
Ben Baker Chris Desino #20039684
HealthSafe Inspections The Ghant #K204
390 Apple Drive 610 S West End St.
Basalt,CO 81621 Aspen, CO 81611 Asbestos PLM Bulk
(970) 920-2100 EPA 600/R-93,M-4/82-020
# Sample Material Description Non-Asbestos Fibers Asbestos Fibers
1 ST-1 Brittle/White None Detected
2 ST-2 Brittle/White None Detected
3 ST-3 Brittle/White None Detected
4 ST-4 Brittle/White None Detected
5 ST-5 Brittle/White None Detected
6 JC-1 Joint Compound/White None Detected
7 JC-2 Joint Compound/White None Detected
8 J-1 Drywall/White None Detected
Joint Compound/White None Detected
Joint Compound/Drywall/White None Detected
Lab Note:Composite of Drywall&Joint Compound.
Collected:Oct 26,2020 Received: Oct 27,2020 Reported: Oct 29,2020 RECEIVED
HAY E S Project Analyst: Date. Reviewed By 1DAtey O 9 2 O 21
0MICROBIAL CONSULTING Renaldo Drakes, 10 29 2020 Darien Williams, �L' a,,,b 1110//-29 - 2020
o � '
cf�t
3005 East Boundary errace, uite F. Midlothian,VA.23112 (804)562-3435 contact@hayesmicrobial.com BUILDING DEPARTMENT
Ben Baker Chris Desino #20039684
HealthSafe Inspections The Ghant#K204
390 Apple Drive 610 S West End St.
Basalt,CO 81621 Aspen,CO 81611 Asbestos PLM Bulk
(970) 920-2100 EPA 600/R-93,M-4/82-020
# Sample Material Description Non-Asbestos Fibers Asbestos Fibers
9 J-2 Drywall/White None Detected
Joint Compound/White None Detected
Joint Compound/Drywall/White None Detected
Lab Note:Composite of Drywall&Joint Compound.
Collected:Oct 26,2020 Received: Oct 27,2020 Reported: Oct 29,2020 RECEIVED
H AY E S Project Analyst: Date: Reviewed By 1DAte/O 9 2 O 21
-
1/
Renaldo Drakes, 10 29 2020 Darien Williams, i �C a„.y 10 -29 -2020
0MICROBIAL CONSULTING ?„__g_j_?1, �, �""'_ c3005 East Boundaryrrace, F. Midlothian,VA.23112 (804)562-3435 contact@hayesmicrobial.com BUILDING DBE RTMf 4T
Ben Baker Chris Desino #20039684
HealthSafe Inspections The Ghant#K204
390 Apple Drive 610 S West End St.
Basalt,CO 81621 Aspen,CO 81611 Asbestos Analysis Information
(970) 920-2100
Analysis Details All samples were received in acceptable condition unless otherwise noted on the report.This report must not be used by the client to claim product certification,
approval,or endorsement by AIHA,NIST,NVLAP,NY ELAP,or any agency.The results relate only to the items tested. Hayes Microbial Consulting reserves the right to
dispose of all samples after a period of 60 days in compliance with state and federal guidelines.
PLM Analysis All Polarized Light Microscopy(PLM) results include an inherent uncertainty of measurement associated with estimating percentages by PLM.
Materials with interfering matrix,low asbestos content,or small fiber size may require additional analysis via TEM Analysis.
TEM Analysis Analysis by TEM is capable of providing positive identification of asbestos type(s) and semi-quantitation of asbestos content.
Definitions 'None Detected'-Below the detected reporting limit of 1%unless point counting is performed,then the detected reporting limit is .25%.
New York ELAP Per NY ELAP198.6(NOB),TEM is the only reliable method to declare an NOB material as Non-Asbestos Containing.
Any NY ELAP samples that are subcontracted to another laboratory will display the name and ELAP Lab Identification number in the report page heading of those
samples.The original report provided to Hayes Microbial Consulting is available upon request.
RECEIVED
H AY E S 11/09/2021
MICROBIAL CONSULTING 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804) 562-3435 contact@a hayesmicrobial.com c 4 of
BUILDINGASP DE RTME4NT
l v ' ;•mom, '....—,
•- +y .i.�! \�l ♦r %;, •k1 �, g-.VV*• ? '��� 11iWr1...i !fry. �,i L'r►114 „ •�� ti1-ri7 i 0' •� ~ 11P1 Y1•-_
•
i.
'- . �.• t,f1f7//%0%.-.bNt0k4'/M, ' '%ai%:LI'?_.\0 , t` /• f/W1$p '04► V •r %•/ /O. . b04 r./
f % IA -'b ./•1 .I'1\%%' 'bV,.-1
• • te,4,;1..0. �iti
� 1}'l,• ;%.. •y. fir. ; • .,„ •.. .. . 4i. i... rr ✓ -;i4} y y � � • ii
}}'' '� m 1 .' =� ) 1�. � m' .��. it . �. x tit --• // . .. - �
• •• •' r.0 1 7.1,r1. ;r,I.. iv, Mr;;*r.1,r. i i 9i , rr , , . • 1:
. S,V.�+il ,1 .tt.ti,tl. if"i,:rV. ilr rJ, .b. .H,Y, � �lJrlzH;�1.V,J.Vtr.n,1 U..11, b.tr'r- t
•
..ID - .. c�' �" ..-3. r.-1.
t ▪ 1 ^ N N CL _ = ,i
Cr r .,
•hr on
v� c i�.
rca. rill
� •...: =
0 -1 CA
.......- •,-.:•0?t ,:.: •4 = _
=r
.� CD a C'i "�Z
: V 1 Cr n 5
l � w
(• ...
0.,* 0 r-r1;"i 'ci.. /4.*,<--,.. ,::y,,4'.'\ Pr- ;#:;;;:r1;i1111."!;.i.r.'1;z11111. '.
W I..• .VSAS: 1.5 I.* •••1• w r. ra+ 0
I-:,;,k_----, .,_
5
t. c, .
_ ._: .
1...oce c.,9 .._-'--:::::!Ig-'':aA4;.-1::F''1;.::::;::.:'::::4.'2:::_k;:%''
..:47.1..iccti..-14 -3 ,..4. ,_. .7:J OM
O "�
- F
O Its •• = IIIII`
�
Z r C Mti
• v�i r =• �imill
- D /� _ , pC�'Q
.. ..,"z,.. ....,„.•.,
•
S R • hI
..,.
_� •Y• ��r 4
S'-.*. i0;".. -;_'-. 2. 1 -,-, 0 ..,-. ..,..4:-.-,,,,,:-.+.,
(P-( i;,-el :: t o- . ,--, ,. ,:..... .1
,..- ....,:, „,„
_, to ..
, ..,;.---,,,,.,,„ , o ..., ,,, . , lity.:-.,:i:.17.,..
x• A3 ,•• 73 ,..., _
"'%
k. r▪ •'•.. r -0 p . O .• •• • •,
t• *-•1.6.;:iiil '-" q --- e...•:.it*:!',1;, ?•7.204
to 't t S-t t l fi c 1 ! 1 1 l 1 1'
_ . l ? tt A S. l l .......... +r: u L'.:'1.(`F rl l i:2 Y±. l u > > .. w SI $, #''✓1
11,
:It Z1Z-c-F.it' ..-.1%.45.;•?.Nalltir 4':::::4•45%,.Istip::.0 ot i.%;•Vit ir,.;:::.ib eii."••i.Itliftle..1.c:,0 4:::109141111810SA 0)4::::1111' I) lir`t'S.:0 r ,p,
0..,
,..:, ..Z.Ikz.,.'-'4 '4:::4:. "..1; -tg:t'sir ,y,..,:l. ; .,,,:et.t. yza. ; .a,..,:17, lea. ; ..,,:,..0 ,,,,,,,,,.. ; ..i.,:e.. .),,,,,:::::4,.. .i.,:-.0.,, -- ,-.., 1
•I• d:. I'rr cif%.
"• .Pf ,�r.1i..'., r,r
.1 I r'� :•• • 'r./1� 1� /.• �'.� • �%Ilr �'•. •�'I /di :i��'�.� �'� %�111i�� ..%��A. .•
I�/% ./. :1.1i .,��:•;• •.•.• ./ If j.lj i ..:'. ..'•, .i11..1�1.1•li'� .•".: ��'•.• ':Ir..1,1!/11�• ./j'.'�t• :�•.. •'11 :i\i �'�..• •'::1. 1�11,� .♦ �•�..• ',Ir..11l�,�l: ` -V
9.15" Al10.! , .,,, ,I�;.,1b .��..• ,1/ 1b .•:•�•:. Ip..ia •:��„ ..04E •:. 4• Ip:.11r 1,, '•,_ 0 1,, JI , . , i
�;.irRii 1.1.1.1�. \bra t\',P.'rrN^•A: 'dilil•• •NA . _ /I/t,1•/ilil•.1111'�' 1. , dvAto;'•Iif.1•' 0,1; ' Va'.f �'If�.�'�;rg,41.'._Qaer,g�IIIf.4•,3.m.,.Z� -'.0,1%j• y11•r1•„' <•\4'1, E
..�_/IA➢ . ��. ��n}. ./� 1 � y;,,.Orr.�. 1� ��i. �� /rr � -- a�� N� _�•Z ,• /r, E i.i.\. ./p. '� .• V ra`J. I/rr1/i1�••��' 1 w1 "fit .i.. taksi .•4,..�►C� `j •://�I�1,4.�N.. : . 41 .I/o..•`►�\\ � �/// : /./ k=�,`��,,,-,. t
�8/ UL
02/28/2022 UILDINGDEPARTMENT
i/:44� . '�yZN,•i •\ '?\� ti Y ''\• 4r•-•..li ,• .,,.f... st f ..ti...1•-•;-.. p+f.;l 4.".• * 4xjf9. � \ .•49,4• ..i yy,v.7,f�,
f�.%,�,•. / . i'I9;;;;f'1•r+, iffl;1f•,;. � .:41feeo.e. :„ i�,•••%•i .:.:•ieo.e.i ;•gy.+4,•,•01q ,,v, .40%.1i;4444.40/:i`, i1.ii�.jj•,�� 4"•;;, .4►i1 •;la :',';1i1l ; :Y +v,00;/;,%L, .i244,44f00,4,%9y1 .,j•00:0,..n.s„. .►/100.010%).;,.;•;. /, J/•.v,,• /+1+.•,•,,o,,,,N.:,„.1z.�.+� -to, q 1q.�+►f+/�l 1/0i•cA �o►el/i//;rq,,\.if 44r• . , ,+0 4 , 'i/':•\\\1,�:�+H,1l,/lil, ,,,N.+.f,90liG%n\\ :40.f.9,0,,AI, R,.f. .00/..4, ,,,ozz.••.•O75�i , fl-,�,, i;, N/if0 fi/„/,''t , ' 1ijP,PAtY'.i•.;4 ,°% a`.,"4i. t;0 //!J-nt;rttil<</ -^\%i, 'i:/i il //°0i`► ,i;i.,4'' //-,%i. r,, 4/Js•`\, ���.:'"�.,...,, .' f4;A\%1V\,'iit' 441.0SIV ,,'',` //00;Ait%i :,t:N,: 4000,�1 \ta;,: rjlh^\\y4 t\ �,, 1/ e;V>>, r;., _/J0/i,1•;%k\'''; 1f4,•• yy� 1 , �&,;;t '�', •y /l ,yyN / At4 i:• ‘ / ' , f
4.
•;-�`r`'7.� aY •Y �Y V 4 Y i:iY V Y� . Y Y Y Y� Y Y Y W i i� f 1'tt• r „'r /��
�A -S,..0.�..„4„,.. I;U1 U;1JI,UlIUIJtJ„JUiJUI,IL...1f..„ le0 i�{ .$'6J.J,JU I j 1,lU1,Il��U�,,...„ 1,IU„....,U,,,,, lJ1,iL;lJ,;Ul, liu,�,JU�,iUJ,1 AIL _?
�j►.... \.ieivvvf�•i�'vvvvvv C!►`v° �+L•/� v v vvv`Iv ��
.'•.-_= 'A) -=_tom;10
Pig z `�f - 1 W"--:-", 0 g 44,40
^: ii�f; '-'� is
r-moo\.t: 0 ((c
Colorado Department
►ezo ay of Public Health (tc7...:;... !";:ii---:ir.r.-..zizt.r..1."..;:.::.1144,::
' �� and Environment w ==
i)
;.:_ =_ ;) ASBESTOS (« - -.:
CERTIFICATION* „ '=
;`ts'V\�•"1. ( -": /,irii Sri•
r4u
')) This certifies that c, _�__`
.4414
+•///
»i Benjamin L Baker « ,""r_:
y_= ===, _ =0 Certification No.. 25863 " '„''
.,\,c<re;; )) has met the requirements of 25-7-507, C.R.S. and Air Quality Control ((C:':::;;)»�Y;. 4
,o: )) Commission Regulation No. 8, Part B, and is hereby certified by the =`
•
ti �' il state of Colorado in the following discipline: Kc =-_ =~
..,, I L
> �� Building Inspector* (c >�»>;.
.i� i-&:rio/.11:.
�' )) ((C -:ve
��_ �) Issued: September 08, 2020 {ic r :.,;,,.�;0..
.k 2.---' W..-*....•..,,::::
( ;
= =.•%??) Expires: September 25, 2021
f) ( .
(C" '.�: .ras', :� �s _ . `
%
r.���2 tip, f;:�� '<�I��i/t
;• •
•.%;=%= m) .This certificate is valid only with the possession of a �(C = Z-:
`pt• �) current Division-approved training course certification ((�` _ ...
65,- 7.- , in the discipline specified above.
,,,����' .. .�) Authorized` CD Representative ((C �`si.*���~•
M) SEAL (C-.1 ;iii%%,., :.
ice..
.� -� '�. ;/1, iON 412. ./1f°"P.%;Iy;/1;I.•I•4 4 I%4 ON I4./1 IS;••1•11.I\./►.11, ;/1;A .,1.el%404I.(/ ,I�•nlfli I►. i �-Z_..�
\.,,-;, D
�:;; :; = H,awl l tIc.g0F, ..- -.---41:„Nii,,,,=':_l' 1'c��t� ;�emi llr;J rittilitmleJ„ I;nl►r;,�teciir„�n�,nJtnta lrrilitraym J.,,,,m n � t�iJ J Jsn�J : un im1fi;r,:..;,_.
--.
. . �-\\` /°I%//77ir \ i.-ii%1Jli \t.,/i:I°�'*ii:r..\�\\Vill°L:'P.; � 0,;:;i°h'ii \:'*kl°1 •�ti,' 1AViO/°IIIl. ,Y.'\ \ %°°„.i.--.-:..a.' °,10;:;:.;, ' �\•'Y`f� i4:-2
►1\y//if^,ri,.,;,. 14Nv/;ir!�;r;,.,,•;,�.,\Z�\v/�°( �'t�0�%�r:���, /,i'',' ;';����:\i�yv/./'�.�;�';;, \4N\//�//rq '.5�r,\4�\Vl,�,.•r.w�.�e•: l�,ii.:•,••%•••�.: \4\\\//�,r-.'-����+
AS:=-..k 41/.•',•'I j•fl;:;Sk, IZt.//.N, 1••0.:1l0-\1V//l.,irtl',•f,,,�.t�.\�:,�'Isir{F.Pl.,ti 4y//',;'0V /1,,1•`�\'Ik•fg',•,1f ij .\Z\y11: ,i of v/I it�rf;4;;Vt\�//
+•�.��•f1Y\�\����/'�lpR,f;r1,�1�\\\��y{p//rf•�•fN,�\tl\��r %/Pl,iflflat\i���j/lP1P,N�1Yy ����ii/.•IP..r1Y�1y'`�Zr//.ilP•11 flt y!ir �fy. /��/'j►i,Nt,,�\��/ d�ij���i
'•ie::zzir �tllii''„1R1i3Ois,101gkW-`''itt/itfes1010lil\\►,';llAP•,OM�s$00\�;` 101 i`.#%is$0%%iez'I'"°+di't*Vf0 4e\V lbil OstitA{►>>,"Cql'' t4 jn vi4."%/j0�101ii1,1 t.i �ii y0f.1.0'rr''.' I
4-4.(104+•�i'4 •0,0•.••t�t,�fiti .,,e0, �'�•4ott '•:•0•f••444ggb. 1:0,,,ff4+•��,�0 �0#"••0�•�olt. .dr,0.1����1tt_r �Y' IA.7►••j1.0�0.►-V 111. V4,41..
avitmQ..•• / .f•tit.t•.• / ff.v.. /f.' .f....:•t•�•0 ,, •f..,..,.• ^ .f�.�.�.t•�i• ` i�ff����•�•'., 'di\'•.f'• ``.c'r .+ �L�N'ai.f.•..�i�•�Y, /4\�`.�'•f..+.•���I
ASFORCOCC YW ANCE L
BUILDING DEPARTMENT