HomeMy WebLinkAboutFile Documents.610 S West End St.0138-2021-BRES (6) Architect Series® Contemporary Sliding Patio Door
?A
Glazing Performance - Total Unit
Glass Performance Values Shaded Areas Meet ENERGY STAR'
al y (mm) Performance Criteria in Zones Shown
c c NFRC Certified Gap
Type of Glazing Product# Fill `o U
U.S. Canada2
7 F LL e
Ext. Int. i li U
jN
> Zone ER Zone
Vent Units N NC SC S CA
13/16° Clear IG PEL-N-238-00001-00001 3 3 Air 1 1
with grilles-between-the-glass 11/1 1111 1 0.51 53 50
I:
with integral grilles 11 100 0.46 0.51 53 50
13/16" Advanced Low-E IG PEL-N-238-00030-00001 3 3 Argon 1 1 Iii.
with grilles-between-the-glass 11/ 1 1111 1 1
with integral grilles PEL-N-238-00161-00001 0.30 1
13/16° 8 1/11. 1111 1 1
with grilles-between-the-glass 11,1. 1/11 1 1
with integral grilles PEL-N-238-00137-00001 0.30 1
13/16" 8 1/1 1111 1 1
with grilles-between-the-glass 111 100 1 1
with integral grilles PEL-N-238-00145-00001 1 1 111
13/16" 8 111 1111 0.30 1
.51 59 51
with grilles-between-the-glass 11/ 100 0.30 0.45 51 51
with integral grilles 11 1,11 0.31 0.45 51 51
Tinted Glazing
13/16° Bronze Advanced Low-E IG PEL-N-238-00038-00001 5 3 Argon 1 1 -
with grilles-between-the-glass111 8 100 1 0.21 29 59 N m
with integral grilles PEL-N-238-00169-00001 1 1
13/16" - 8 111 4 1111 1,.29 1
with grilles-between-the-glass110L 1111 1 0.20 25 55 N m SC S
with integral grilles PEL-N-238-00173-00001 0.30 0.20
13/16" 111 1111 1 1
with grilles-between-the-glass111i6 1/11 1 0.24 39 61 N m SC S
integralwith grilles 11 1111 0.30 1
High Altitude Glazing
13/16" Advanced Low-E IG PEL-N-238-00029-00001 3 3 Air 0.33 0.28 52 56
with grilles-between-the-glass PEL-N-238-00029-00002 0.33 0.25 45 56
with integral grilles PEL-N-238-00160-00001 0.33 0.25 45 56
13/16" SunDefense Low-E IG PEL-N-238-00005-00001 3 3 Air 0.32 0.21 48 53
with grilles-between-the-glass PEL-N-238-00005-00002 0.32 0.19 42 53
with integral grilles PEL-N-238-00136-00001 0.33 0.19 42 53 II
13/16" AdvancedComfort Low-E IG PEL-N-238-00013-00001 3 3 Air 0.27 0.27 51 49
with grilles-between-the-glass PEL-N-238-00013-00002 0.27 0.24 44 49 N NCIi"
with integral grilles PEL-N-238-00144-00001 0.30 0.24 44 51 N NC
13/16" NaturalSun Low-E IG PEL-N-238-00021-00001 3 3 Air 0.33 0.51 59 49
with grilles-between-the-glass PEL-N-238-00021-00002 0.33 0.45 51 49
with integral grilles PEL-N-238-00152-00001 0.34 0.45 51 49
R-Value=1/U-Factor Climate Zones te
SHGC=Solar Heat Gain Coefficient ti,04.4_a�a
CRTk=ndibletonReiht sanceon . �.-- F '�
a.
CR=Condensation Resistance � � � `5� t ,4,11,,,,:x.. ,..
ER=Canadian Energy Rating �L_ +;y`
(1)Glazing performance values are calculated for Pine using NFRC 100,NFRC 200 and NFRC 500.Thermal performance ofAL lall61 r"fl
other wood species may vary.ENERGY STAR®values are updated to 2016(Version 6)criteria. '�j \'tiler
- fa110.ED
(2)The values shown are based on Canada's updated ENERGY STAR®2020 initiative. fik , • • _ ,fi 17l
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines. r r"
11/09/2021
Pella 2020 Architectural Design Manual I Division 08-Openings I Windows and Doors I www.Pella.com ASP
BUILDING DEPARTMENT