Loading...
HomeMy WebLinkAboutMaster Permit.211 W Hopkins Ave.0078-2021-BRES (9) 211 West Hopkins Mechanical Documents House RECEIVED 05/21/2021 ERV- 1 - House Energy Recovery aldes /entilator saldes RESIDENTIAL ERV • E190-TRG • P!] ENERGY RECOVERY VENTILATOR 165 CFM at 0.40 in.w.g (ESP) c ETA US ° z,00�, r1 Made in 5 year 5 year �"� Canada Warranty Warranty Intertek CERTIFIED c22.2no113 UNIT CORE UL 1812 PRODUCT DESCRIPTION Compact size, large performance—the E190-TRG energy )NRecovery Core recovery ventilator produces approximately 165 CFM at �`0! Material: High-latent-transfer enthalpy 0.4 in w.g. (ESP) and recovers sensible and latent heat through its high-latent-transfer core. The E190-TRG has Casing been thoughtfully engineered for simple installation in and Material: Pre-painted 24-gauge galvanized steel spacious houses. Duct Connections:0 6" (0 152 mm) Insulation: Molded EPS Width: 29-3/16" (741 mm) Height: 21" (533 mm) Recommendation : Depth: 15-1/8" (384 mm) Ideal for homes from 1500ft2 to 2500ft2 Weight: 46 lbs (21 kg); Shipping Weight: 51 lbs (23 kg) Supply Damper: Motorized; Exhaust Damper: Gravity Mounting KEY FEATURES Suspended by chains with vibration-isolating springs Electronically and independently adjustable supply and exhaust blowers (FLEXControl) 0-10 Electrical requirement Gauge ports on the door for fast and reliable airflow readings VOLT 120 VAC, 60 Hz, 1.95 A, 155 W Cord Set: 48" (1219 mm)with ground Non-dust-loading backward-inclined impellers on totally enclosed motors ei Frost control Twist-in collars for easy flex-duct attachment Automatic timed recirculation, fifth port. Cycles controlled by a temperature sensor when outdoor Easy access to core and filters for cleaning temperature drops below 14°F (-10°C) Durable High Latent Transfer enthalpy core has exceptional moisture transfer for increased comfort and no drain required. Filters Recirculating defrost collar snaps into pre-punched area of FILTRATION Type : Aluminum (P/N 683959) cabinet for ducting flexibility Option : MERV 6 (P/N 683958) or high-efficiency MERV 13 (P/N 683957) g RECEIVE Blowers VENTILATION Motorized impellers (backward-inclined) 05/21/2021 ASPEN BUILDING DEPARTMENT Dimensions Controls FRONT VIEW Low voltage dry contact (24VAC) for interlock with heating/cooling systems. Yiiiil fiii r r� Digital Multifunction Control Hil (#611242) and (#611242-FC) A 21" (533 mm) J LCD Electronic Multifunction Control (P/N 611227) n I o 1 0 Ilia 0 1 ° ®p k Z93/16rr (741 mm) 20/40/60 Minute Timer(P/N 611228) SIDE VIEW TOP VIEW 26." Speed Control (Low/Intermittent/High) (632 mm) _ • 1 (P/N 611229) ACCESS (4888mm) to" .- a- PANEL (254mm) . si 1 n„mm) • I A06"Typ. ' ;' ) Mode Control C (0152 mm) �i� (116 mm) - (Recirculation) (P/N 611230) /I (267 m 5 5 ire a (384 mm) OUTSIDE SUPPLY s re AIR AIR (354 mm) RETUNR EXHAUST AIR Performance AIR E190-TRG Outside Air Net Airflow Adjusted Latent Ventilation Performance Temperature Power Sensible Total Sensible Recovery/ -1 2 Consumed Recovery Recovery tT 4 .HS max Recovery Moisture 3 ,p° °F °C CFM Us (1M Efficiency Efficiency Transfer Efficiency •♦ •Hs min _ 0 N +4 3 ♦ Flex control 7 os° • ip iiLS max Heating • ♦ 4HS 142W ♦ • •LS min 4L5 98W 32 0 51 24 52 76% 84% 0.69 a ilk_0,60 • 4 1 HS 55 W • IP • High 1 LS 36W 32 0 81 38 62 72% 78% 0.66 N en Speed 32 0 119 56 106 67% 73% 0.60 - E • o,4° -13 -25 74 35 89 60% 63% 0.63 - x 020 • a^ W A peed Cooling Y• • • ♦ 95 35 81 38 62 - - 055 56% 0,00 0 100 200 Airflow CFM Project: Architect: Location: Engineer: Model#: Contractor: Quantity: Comments: Submitted By: Date: �` ► f—— - 1 ED p You For more information, contact your Aides sales advisor,visit aldes-na.com, call 1.800.255.7749, or find us on in0 05/21/k021 ©2020 American ALDES Ventilation Corporation and©2020 ALDES Canada.El 90-TRG_1 220.Aides reserves the right to modify its products at any time to introduce new technologies. Of ASPEN BUILDING DEPARTMENT F- 1 / CU- 1 - House Furnace & LEN!WJX2 CondensingUnit Project Submittal Tag: Main House Fl Condenser: SL28XCV-048-230 Evaporator Coil: CX35-48C-F Furnace: SLP99UH090XV48C UNIT OVERVIEW AHRI Reference-206401660 Gross Cooling Net Cooling Supply EAT LAT SEER Ttl/Sens Ttl/Sens Air Flow ESP/TSP DB/WB DB/WB Voltage EER Tons (MBH) (MBH) (cfm) (in.WC) (°F) (°F) 208V/1Ph 22 4.0 48.0/34.7 46.2/32.9 1,580 0.5/0.7 80.0/67.0 52.1/52.1 60Hz 13.5 COOLING Cooling Performance Temperatures(DB/WB°F) Gross Cooling(Ttl/Sens) 48.0/34.7 MBH Ambient 82.0 Net Cooling(Ttl/Sens) 46.2/32.9 MBH Condenser Ambient Coil Moisture Removal 12.55 lb/hr Entering 80.0 67.0 Leaving-(Coil) 52.1 52.1 Leaving-(Unit) 53.6 53.6 ARI Performance Compressors Refrigerant Condensate Drain ARI Cooling 46,000.0 MBH Cooling Stages Variable Type R-410A Qty 2 Compressor Qty 1 Cond Suction Line 7/8 Size 0.75 in. Cond Liquid Line 3/8 Pipe Thread fpt Coil Suction Line 7/8 Coil Liquid Line 3/8 HEATING i Heating Performance Temperatures(DB/WB°F) Specifications Output(High/Low) 85.0/30.0 MBH Ambient 0.0 0.0 Thermal Efficiency 98.0% Input(High/Low) 88.0/31.0 MBH Entering Gas Line Size 0.5 in. Leaving 49.8 Heat Rise 49.8 SUPPLY FAN Air Flow(cfm) Supply Fan r Air Resistance(in.WC) Supply 1,580 Nominal Power 0.75hp Total 0.70 Outdoor Drive Type ECM Variable Speed Constant Ext Supply 0.50 Volume Return Speed Supply Fan Total Orientation Wet Coil 0.20 ELECTRICAL Condenser I Furnace Voltage 208V/1 Ph/60Hz Voltage 120V/1 Ph/60Hz MCA 22 amp MCA LESS THAN 12 amp MOCP 35 amp MOCP 15 amp Condenser Oper Range-Nom Volt +/-10% Oper Range-Nom Volt +/-10% ADDITIONAL DATA MIMI.. Condenser I Furnace Evaporator Coil Dimensions 39.50 in.x 35.50 in.x 47.00 in. Dimensions 29.25 in.x 21.00 in.x 33.00 in. Dimensions 22.00 in.x 24.50 in.x 28.25 in. Total Weight 296 lb Total Weight 166 lb Total Weight 60 lb RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 2 of 1PSPEN BUILDING DEPARTMENT LEIVNIJX) Project Submittal Tag: Main House Fl Field Installed Accessories Catalog Number Qty Description 44J22 1 Air Fltr and Rack Kit Side Ret(Single)Field Installed 51 W11 1 FLUSH Mount Vent Kit US Field Installed 14T65 1 Pressure Switch 2-Stage(.90/.25)(UH)Field Installed Product Features Cabinet Heavy gauge galvanized steel cabinet Heavy Gauge Cold Rolled Steel Cabinet PermaGuard" Unit Base Cooling System Non Chlorine,Ozone Friendly Refrigerant,R410A Quantum Coil/Fortified aluminum allow tube/enhanced fin coil Hi-Capacity Drier factory installed in liquid line Low Pressure Switch Twin Coils assembled in an"A"configuration Check and Expansion Valve is factory installed Accumulator Compressor Crankcase Heater Factory Installed iComfort®Communicating Control SmartHinge'Louvered Coil Protection Variable-Speed Outdoor Coil Fan Motor With Integrated Control High Pressure Transducer Variable Capacity Scroll Compressor DC Inverter Control Heating System Aluminized Steel Inshot Burners Aluminized Steel Tubular Heat Exchanger SureLight(R)Hot Surface Ignition Warranty Condenser See Limited Warranty Certificate included with unit for details Condenser Limited compressor warranty of 10 years for Residential Installations Condenser Limited compressor warranty of 5 years for Non-Residential Installations Condenser Limited warranty on all covered components of 1 year in Non-Residential Installations Condenser Limited warranty on all covered components of 10 years in Residential Installations Coil See Limited Warranty Certificate included with unit for details Coil Limited warranty on all other covered components of 1 year(Comm Use) Furnace See Limited Warranty Certificate included with unit for details Furnace Limited warranty on heat exchanger of 20 years Furnace Limited warranty on all other covered components of 1 year(Comm Use) Furnace Limited warranty on Surelight ignition control system of 1 Year(Comm Use) RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 3 of 1 P SPEN BUILDING DEPARTMENT LEI1IMIJX $ Project Submittal UNIT SUPPORT n;; 1 .iuuutiuuIIIIIIIIMIUin��tX.A FEET \ti titi0 IP\II 1111IIIIIIIIIIII111111111114 MhW�M M11 IIIIII11IIIIIN111 1X i e) ;, IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMII o 0 o 26-718 1111M'IIIINIIIUIIIIIIIIIUIIII�II�IINI I ' (4�' (683) �I� M1211111= 11MObh� I � O' PIM41�' j --_-___"'"'moIIIIIIIIIIIIIll11�41411111 & 4 (222) i 3w t I 195) • 3118 I 303/4 �4 TOP VIEW (79)���III (781) (117) TOP VIEW BASE SECTION (Large Base) 39-1/2(1003) 35 1!2(902) ► DISCHARGE t AIR'll r� I =4: — — 7 'HIGH VOLTAGE - 121*1- s = ELECTRICAL t �.:-.:.._.---.—-- —. INLET —• :_.— -- s•::•:—== =-- s W.-0.. s-= 111 - =-== SUCTION LINE - ( ) , — _--:: :•— - INLET -' s --=-:s: :•-� = ,. , f LIQUID LINE tT OW VOLTAGE INLET 16 ELECTRICAL (406) INLET , _ - - ii 18203 1 t t u u 111(25) SIDE VIEW ACCESS VIEW RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 4 of"ASPEN BUILDING DEPARTMENT LENN(JX) Project Submittal CX35-24(AJB), -30(AJB), -48(B/C), -60/60C and -60D Coils (NOTE - See next page for CX35-49C-6F and CX35-60C-6F Coils) t 314(19) j 3/4 ; r 19-1!2 3M (19) (495) (19) C OUTLET NOTE-CX354i0D coil is positioned in cabinet [ OPENING with coil face running left to right, C all other coil sizes are positioned like Jawing. 4 3.4 119) TOP VIEW I'll A 1 (1/9) i 14. 211533) ' I i 1 • / / L. / / H f SUCTION _!---- AIRLINE - l }e F 4 FLOW l � LIOUID__E—!__ _ LINE C t , >C [ . 1-1/2 .. 4_1-1 4 (38) 13 2 INLET 2-5,8 CONDENSATE INLET OPENING(67) DRAINS 20716 OPENING 9/16 D 9/16 141 (519) (1� (14} FRONT VIEW (1� SIDE VIEW Model A B C D E F G H Number in. nrn in. mm in. mm in_ mm in. mm in_ mm in_ mm in_ mm CX35 24A-6F 14-12 368 18-1/2 470 13 330 13-3/8 340 9-3/4 248 3-518 92 2-5/8 66 2-3/8 80 CX35-248-6F 17-1.2 445 18-1/2 470 18 408 18-3/8 416 8-3/4 248 3-5/8 92 2-5/8 dd 2-3/8 60 CX35 30A-6F 14-12 368 22-1/2 572 13 330 13-3/8 340 11-1/2 292 3-518 92 2-5/8 68 2-3/8 80 CX35-30B 6F 17-1/2 445 22-1/2 572 18 406 18-3/8 416 11-12 292 3-5.8 92 2-5/8 66 2-31860 CX35-48B$F 17-1/2 445 27-1/2 ON 16 408 18-3/8 416 12-1/2 .318 3-5/8 92 2-5/8 88 2-3/8 80 CX35-48C-6F 21 533 27-1/2 6gg 19-1/2 495 19-7/8 505 12-12 318 3-5.8 92 2-5I8 66 2-3 8 60 CX35-50/60C-GF 21 533 27-1/2 890 19-12 485 19-7/8 505 12-1/2 318 3-5/8 92 2-5/8 66 2-3/8 60 CX35-60D-6F 24-1,2 622 29-12 749 23 584 23-3/8 594 10 254 3-5.8 92 2-5/8 66 2-3/8 60 RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 5 of 1P►SPEN BUILDING DEPARTMENT LENNIJXJ Project Submittal UPFLOW POSITION C35/CX35 C35 44"..... Model No Cased Uncased A B A B C35/CX35 in. mm in. mm in. mm in. mm / C35/CX35-18/24B 16-1/2 419 49-1/2 1257 14-1/8 359 47-1/8 1197 // '1 �\ ,\ I C35/CX35-24B 18-1/2 470 51-1/2 1308 16-3/8 416 49-3/8 1254 // i 11\ � . C35/CX35-30B 22-1/2 572 55-1/2 1410 20-3/4 527 53-3/4 1365 l\ �� B C35/CX35 30/36B C35/CX35-30/36C 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403 �_ C35/CX35-36B 24-1/2 622 57-1/2 1461 22-3/8 568 55-3/8 1407 33 (838) C35/CX35-48B 0 ef ' ' 1 C35/CX35-48C 27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505 C35/CX35-49C 29-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562 0 V C35/CX35-50/60C 27-1/2 699 60-1/2 1537 25-7/8 657 58-7/8 1495 CX35-60C 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616 • CX35-60D 29-1/2 749 62-1/2 1588 28 711 61 1549 HORIZONTAL POSITION Model No. A B B 33 in. mm in. mm (838) CH35 0_,......,,,,,,,,-; A CH35-24B, CH35-36C, 26-1/2 673 59-1/2 1511 CH35-30B, CH35-42C, • CH35-36B, CH35-48C / 1 I. CH35-42B, CH35-51C 31-1/2 880 64-1/2 1638 // o CH35-48B, ko/N11- '1 — CHX35 :4I tiCHX35-24B, CHX35-36C, 26-1/2 673 59-1/2 1511 CHX35-30B, CI-IX35-42C, = CHX35-36B, CHX35-48C CHX35-42B, CHX35-51/61C, 31-1/2 880 64-1/2 1638 CHX35-48B, CHX35-60D RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 6 of 1PSPEN BUILDING DEPARTMENT LENI'IfiKJ Project Submittal 1 NOTE-60C and 60D size units that require air volumes over 3-1/4 EXHAUST AIR 1800 cfm must have one of the following: -01(83) OUTLET 1.Single side return air and Optional Return Air Base with transition that must accommodate required 1-7/8(48) • - 20 x 25 x 1 inch(508 x 635 x 25 mm)air filter to + maintain proper velocity. 2.Bottom return air. D 3.Return air from both sides. 4.Bottom and one side return air. SUPPLY AIR �� OPENING See Blower Performance Tables for additional information- 2 Optional Side Return Air Fitter Kit is not for use COMBUSTION with the Optional Return Air Base. AIR INTAKE �I - 2 OPTIONAL 23-3/4 Flue Condensate Trap Assembly SIDE RETURN i (3-3/ I J Furnished for external 7 AIR FILTER KIT (Either Side) 25 field installation = o (178) (635) on either side of unit. (See installation instructions TOP VIEW for additional 'Mill � information.) OWti 1J -saw air"- A _1-1/2(38) 27-3/4 Front Panel (705) — fro-- B I 9/16 I r 19-7/16 (494) `I (14 r1 1 V 6-9/16(167)r�Left 2(51) i (Either Side) 9(229) Z Right GAS PIPING INLET OPTIONAL 12-5/8(321) t + (Either Side) SIDE RETURN (Either Side) AIR FILTER KIT CONDENSATE (Either Side) 33 + TRAP CONNECTION (838) (Either Side) ELECTRICAL--t (Either6-1/2(165) INLET 11------L-) Side) (Either Side) 14-3/4 i— (584)23 �� +1(38) (375) 'Side Return 14 16 Air Opening (356) (406) (Either Side) i. = ,i IL 1-15/16(49) 4_5/8 it 3/4,1 I�I_ _�1 I I,3/4 (16) 3-114 23-1/2 (19) C (19) (97 (597) 'Bottom Return 1 Bottom Return Air Opening Air Opening FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm • SLP99UH070XV36B 17-1/2 446 16-3/8 416 16 406 7-5/8 194 SLP99UH090XV36C SLP99UH090XV48C 21 533 19-7/8 505 19-1/2 495 9-3/8 238 SLP99UH090XV60C SLP99UH110XV60C SLP99UH135XV600 24-1/2 622 23-3/8 594 23 584 11-1/8 283 RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 7 of 1PSPEN BUILDING DEPARTMENT F-2 / CU-2 - House Furnace & LEI'II'IIJX) Condensing Unit Project Submittal Tag: Main House F2 Condenser: SL28XCV-060-230 Evaporator Coil: CX35-60C-F Furnace: SLP99U H090XV60C UNIT OVERVIEW AHRI Reference-206401696 Gross Cooling Net Cooling Supply EAT LAT SEER Ttl/Sens Ttl/Sens Air Flow ESP/TSP DB/WB DB/WB Voltage EER Tons (MBH) (MBH) (cfm) (in.WC) (°F) (°F) 208V/1Ph 21.5 5.0 61.2/45.0 58.8/42.6 2,010 0.5/0.8 80.0/67.0 50.8/50.8 60Hz 12.5 COOLING W -mmmi_ mmmmmmm Cooling Performance M Temperatures(DB/WB°F) Gross Cooling(Ttl/Sens) 61.2/45.0 MBH Ambient 82.0 Net Cooling(Ttl/Sens) 58.8/42.6 MBH Condenser Ambient Coil Moisture Removal 15.23 lb/hr Entering 80.0 67.0 Leaving-(Coil) 50.8 50.8 Leaving-(Unit) 52.3 52.3 ARI Performance Compressors Refrigerant Condensate Drain ARI Cooling 57,000.0 MBH Cooling Stages Variable Type R-410A Qty 2 Compressor Qty 1 Cond Suction Line 1.125 Size 0.75 in. Cond Liquid Line 3/8 Pipe Thread fpt Coil Suction Line 7/8 Coil Liquid Line 3/8 HEATING i Heating Performance Temperatures(DB/WB°F) Specifications Output(High/Low) 87.0/30.0 MBH Ambient 0.0 0.0 Thermal Efficiency 98.7% Input(High/Low) 88.0/31.0 MBH Entering Gas Line Size 0.5 in. Leaving 40.1 Heat Rise 40.1 SUPPLY FAN Air Flow(cfm) Supply Fan = Air Resistance(in.WC) Supply 2,010 Nominal Power 1hp Total 0.83 Outdoor Drive Type ECM Variable Speed Constant Ext Supply 0.50 Volume Return Speed Supply Fan Total Orientation Wet Coil 0.33 ELECTRICAL Condenser I Furnace Voltage 208V/1 Ph/60Hz Voltage 120V/1 Ph/60Hz MCA 30 amp MCA LESS THAN 12 amp MOCP 50 amp MOCP 15 amp Condenser Oper Range-Nom Volt +/-10% Oper Range-Nom Volt +/-10% ADDITIONAL DATA 1116111F 1111111111 Condenser I Furnace Evaporator Coil Dimensions 39.50 in.x 35.50 in.x 47.00 in. Dimensions 29.25 in.x 21.00 in.x 33.00 in. Dimensions 22.00 in.x 21.00 in.x 32.25 in. Total Weight 296 lb Total Weight 166 lb Total Weight 73 lb RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 8 of 1PSPEN BUILDING DEPARTMENT LEIVNIJX) Project Submittal Tag: Main House F2 Field Installed Accessories Catalog Number Qty Description 51 W11 1 FLUSH Mount Vent Kit US Field Installed 14T65 1 Pressure Switch 2-Stage(.90/.25)(UH)Field Installed 50W99 1 Return Air Base Upflow Only Field Installed Product Features Cabinet Heavy gauge galvanized steel cabinet Heavy Gauge Cold Rolled Steel Cabinet PermaGuard" Unit Base Cooling System Non Chlorine,Ozone Friendly Refrigerant,R410A Quantum Coil/Fortified aluminum allow tube/enhanced fin coil Hi-Capacity Drier factory installed in liquid line Low Pressure Switch Twin Coils assembled in an"A"configuration Check and Expansion Valve is factory installed Accumulator Compressor Crankcase Heater Factory Installed iComfort®Communicating Control SmartHinge'Louvered Coil Protection Variable-Speed Outdoor Coil Fan Motor With Integrated Control High Pressure Transducer Variable Capacity Scroll Compressor DC Inverter Control Heating System Aluminized Steel Inshot Burners Aluminized Steel Tubular Heat Exchanger SureLight(R)Hot Surface Ignition Warranty Condenser See Limited Warranty Certificate included with unit for details Condenser Limited compressor warranty of 10 years for Residential Installations Condenser Limited compressor warranty of 5 years for Non-Residential Installations Condenser Limited warranty on all covered components of 1 year in Non-Residential Installations Condenser Limited warranty on all covered components of 10 years in Residential Installations Coil See Limited Warranty Certificate included with unit for details Coil Limited warranty on all other covered components of 1 year(Comm Use) Furnace See Limited Warranty Certificate included with unit for details Furnace Limited warranty on heat exchanger of 20 years Furnace Limited warranty on all other covered components of 1 year(Comm Use) Furnace Limited warranty on Surelight ignition control system of 1 Year(Comm Use) RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 9 of 1PSPEN BUILDING DEPARTMENT LEI1IMIJX $ Project Submittal UNIT SUPPORT n;; FEET 1 .iuuutiuuIIIIIIllW I i'n��t' A \ti titititi JP\ 1� I111IIIIIIIIIIII111111111114 MhW�M 11 1�NI�111IIIIII�IIIIIN11115�i ;, ;, IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMII o 0 o 26-718 1111M'IIIINIIIUIIIIIIIIIUIIII�II�IINI I ' (4�' (683) �I� M1211111= 11MObh� I � O' PIM41�' j --_-___wilITNIIIIIIIIIIIllll11�41411111 & 4 (222) i 3w t I 195) • 3118 I 303/4 �4 TOP VIEW (79)���III (781) (117) TOP VIEW BASE SECTION (Large Base) 39-1/2(1003) 35 1!2(902) ► DISCHARGE t AIR r� I =4: - - 7 'HIGH VOLTAGE - s = ELECTRICAL t �.:-.:.._.---.—-- —. INLET —• :_.-- -- s•::•: == =-- ::s s 111 =-= SUCTION LINE - ( ) , — _--:: :•— - INLET -' s --=-:s: :•-� = ,. , f LIQUID LINE t OW VOLTAGE INLET 16 ELECTRICAL (406) INLET , _ - - ii 18203 1 t t u u 111(25) SIDE VIEW ACCESS VIEW RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 10 of 1ASPE:N BUILDING DEPARTMENT LENNIJX) Project Submittal CX35-49C-6F and CX3540C4F t 3/4(19) 1-3/4_..., 19-1/2 314 (44) (495) (19) 19-1!2 (495) OUTLET r aPENNG CL #3/4(19) TOP V E W re_ 21 22 (S33) 3/4_ei (559) rn1 Ill (19) i 14. 1 1 % \ 11 ‘ \ 11 1 \ R / 11 '1 ' C 1/ , 1 D + f SUCTION 1 LINE / ; -.el E , - B t FAOW IR 1 1 - A LIQUD_�- - ----�--- LINE Lt 4 (38) (-1! INLET 2-58 CONDENSATE INLET OPENING (67) DRAINS OPENING 19-7!8 21-71169/16 9!16 (505) 9!16 iL (545) (14) (14) FRONT VIEW (14) SIDE VEW Model A T B C D E Number in_ mm in. mm in. mm in. mm in. mm CX35-49C-6F 10 254 3-5/8 92 29-1/2 749 2-3/8 80 2-5/8 68 CX35-60C-6F 14-''2 388 3-51 92 31-112 800 2-3;'8 80 2-5/8 88 RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 11 of 1ASPEN BUILDING DEPARTMENT LENNIJXJ Project Submittal UPFLOW POSITION C35/CX35 C35 44"..... Model No Cased Uncased A B A B C35/CX35 in. mm in. mm in. mm in. mm / C35/CX35-18/24B 16-1/2 419 49-1/2 1257 14-1/8 359 47-1/8 1197 // '1 �\ ,\ I C35/CX35-24B 18-1/2 470 51-1/2 1308 16-3/8 416 49-3/8 1254 // i 11\ � . C35/CX35-30B 22-1/2 572 55-1/2 1410 20-3/4 527 53-3/4 1365 l\ �� B C35/CX35 30/36B C35/CX35-30/36C 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403 �_ C35/CX35-36B 24-1/2 622 57-1/2 1461 22-3/8 568 55-3/8 1407 33 (838) C35/CX35-48B 0 ef ' ' 1 C35/CX35-48C 27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505 C35/CX35-49C 29-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562 0 V C35/CX35-50/60C 27-1/2 699 60-1/2 1537 25-7/8 657 58-7/8 1495 CX35-60C 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616 • CX35-60D 29-1/2 749 62-1/2 1588 28 711 61 1549 HORIZONTAL POSITION Model No. A B B 33 in. mm in. mm (838) CH35 0_,......,,,,,,,,-; A CH35-24B, CH35-36C, 26-1/2 673 59-1/2 1511 CH35-30B, CH35-42C, r • CH35 36B, CH35-48C / 1 I. CH35-42B, CH35-51C 31-1/2 880 64-1/2 1638 // o CH35-48B, ko/N11- '1 — CHX35 :4I tiCHX35-24B, CHX35-36C, 26-1/2 673 59-1/2 1511 CHX35-30B, CI-IX35-42C, = CHX35-36B, CHX35-48C CHX35-42B, CHX35-51/61C, 31-1/2 880 64-1/2 1638 CHX35-48B, CHX35-60D RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 12 of 1ASPEN BUILDING DEPARTMENT LENI'IfiKJ Project Submittal 1 NOTE-60C and 60D size units that require air volumes over 3-1/4 EXHAUST AIR 1800 cfm must have one of the following: -01(83) OUTLET 1.Single side return air and Optional Return Air Base with transition that must accommodate required 1-7/8(48) • - 20 x 25 x 1 inch(508 x 635 x 25 mm)air filter to + maintain proper velocity. 2.Bottom return air. D 3.Return air from both sides. 4.Bottom and one side return air. SUPPLY AIR �� OPENING See Blower Performance Tables for additional information- 2 Optional Side Return Air Fitter Kit is not for use COMBUSTION with the Optional Return Air Base. AIR INTAKE �I - 2 OPTIONAL 23-3/4 Flue Condensate Trap Assembly SIDE RETURN i (3-3/ I J Furnished for external 7 AIR FILTER KIT (Either Side) 25 field installation = o (178) (635) on either side of unit. (See installation instructions TOP VIEW for additional 'Mill � information.) OWti 1J -saw air"- A _1-1/2(38) 27-3/4 Front Panel (705) — fro-- B I 9/16 I r 19-7/16 (494) `I (14 r1 1 V 6-9/16(167)r�Left 2(51) i (Either Side) 9(229) Z Right GAS PIPING INLET OPTIONAL 12-5/8(321) t + (Either Side) SIDE RETURN (Either Side) AIR FILTER KIT CONDENSATE (Either Side) 33 + TRAP CONNECTION (838) (Either Side) ELECTRICAL--t (Either6-1/2(165) INLET 11------L-) Side) (Either Side) 14-3/4 i— (584)23 �� +1(38) (375) 1 Side Return 14 16 Air Opening (356) (406) (Either Side) i. = ,i IL 1-15/16(49) 4_5/8 it 3/4,1 I�I_ _�1 I I,3/4 (16) 3-114 23-1/2 (19) C (19) (97 (597) 'Bottom Return 1 Bottom Return Air Opening Air Opening FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm • SLP99UH070XV36B 17-1/2 446 16-3/8 416 16 406 7-5/8 194 SLP99UH090XV36C SLP99UH090XV48C 21 533 19-7/8 505 19-1/2 495 9-3/8 238 SLP99UH090XV60C SLP99UH110XV60C SLP99UH135XV600 24-1/2 622 23-3/8 594 23 584 11-1/8 283 RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 13 of'ASPEN BUILDING DEPARTMENT H-1 - House Humidifier condair Data Sheet - HUM-1 EL Series IT Project Name: 211 West Hopkins Project Number: Salesperson: James Murphy Date: 2021-03-18 Calculation Basis Humidification Load 10.8 lbs/h Temperature 0°F (total) Outside Air Relative Humidity 62% Duct Size 26 x 12 in. Absolute Humidity 4.6 gr/lb Duct Orientation Horizontal Temperature 55°F Before Total Air Volume 1580 CFM Relative Humidity 56 Outside Air 25% Humidification Absolute Humidity 48.4 gr/lb Air Velocity 728.1 ft./min After Temperature 55°F Altitude 8018 ft Humidification Relative Humidity 73 Absolute Humidity 63.0 gr/lb Air Pressure 10.9 psig Humidity Increase 58.4 gr/lb Temperature 72°F Space Design Relative Humidity 40% Absolute Humidity 63.0 gr/lb Product Data EL 020/208/3 Rated Power: 7.50 kW Maximum Water Pressure: 80 psig Power Circuit: 208/3/60 V/Ph/Hz Width: 16.5 in. Rated Current(MCA): 20.80 A Height: 26.4 in. Maximum Current(MOCP): 25.00 A Depth: 14.4 in. Cylinders: 1 Net Weight: 45 lbs Cylinder Type: 303 Full Weight: 55 lbs Steam Outlet OD: 0.88 in. Front Clearance: 36 in. Quantity Steam Outlets: 1 Left Clearance: 0 in. Fill Rate: 0.2 GPM Right Clearance: 0 in. Drain Rate: 1.6 GPM Ceiling Clearance: 12 in. Nominal Capacity: 20 lbs/h Floor Clearance: 24 in. Rated Capacity: 22 lbs/h Supply Water: 0.5 in. Minimum Output Range: 4 lbs/h Drain Water OD: 1.18 in. Minimum Water Pressure: 30 psig Condensate Return: 0.38 in. Header mini SAM-e 24", 3" ctr, 0.875" tube Nominal Capacity: 210 lbs/h Length: 23.1 in. Width: 23.1 in. Product Length: 12 in. RECEIVED 18.03.2021 211 West Hopkins o s 7214/2 0 21 ASPEN BUILDING DEPARTMENT -~condair Psychrometric Diagram Outside: 0 °F/62 % Mixing point: 54 °F/58 % Before humidification: 55°F/56 % After Humidification: 55°F/73 % Inside: 72 °F/40 % so 80 4iktikt{4-Na4VV474W4A1 f. At4,.:,4Z_Vv1PV‘o Ak'il *tikAkIWI e . 4-1 •41kAtip41/44'ibik'zil"*..ii°,411"641-Itikla-.4e11;%"":Z41' ''''.:NIII 2 Illik*E *29 i. dvwv,th. k.kkkTk ' ' ,if %,......„...„,,,Ntoopitts, ,, %Vb.% Ntt. 41 ''''', Alt>s- i 41 50.a�.�:4;. �►\�i\.`►i%'Z► .4` \kik �i�` � �oi� 41:4iWrAW*.t74Z.ZAI*"'A VAIV "i., Nvk,,, .� ` 1A: ' � .k\ %. S$`ems: � V 1 ORS `_t� ��� `� � /f ``��j \� . ,..IN v, o .......,-A-4.. ...,-,yc- i i 1 i 1 1 1 40 0 60 i 0 80 90 100 11 0 1 20 130 1 40 Dry bulb temperature-deg F RECEIVED 18.03.2021 211 West Hopkins 057216/2021 ASPEN BUILDING DEPARTMENT H-2 - House Humidifier condair Data Sheet - HUM-2 EL Series I Project Name: 211 West Hopkins I Project Number: Salesperson: James Murphy . , Date: 2021-03-18 Calculation Basis Humidification Load 11.9 lbs/h Temperature 0°F (total) Outside Air Relative Humidity 62% Duct Size 32 x 12 in. Absolute Humidity 4.6 gr/lb Duct Orientation Horizontal Before Temperature 55°F Total Air Volume 2010 CFM Humidification Relative Humidity 49 Outside Air 25% Absolute Humidity 42.4 gr/lb Air Velocity 752.8 ft./min After Temperature 55°F Altitude 8018 ft Humidification Relative Humidity 64 Absolute Humidity 55.0 gr/lb Air Pressure 10.9 psig Humidity Increase 50.4 gr/lb Temperature 72°F Space Design Relative Humidity 35 Absolute Humidity 55.0 gr/lb Product Data EL 020/208/3 Rated Power: 7.50 kW Maximum Water Pressure: 80 psig Power Circuit: 208/3/60 V/Ph/Hz Width: 16.5 in. Rated Current(MCA): 20.80 A Height: 26.4 in. Maximum Current(MOCP): 25.00 A Depth: 14.4 in. Cylinders: 1 Net Weight: 45 lbs Cylinder Type: 303 Full Weight: 55 lbs Steam Outlet OD: 0.88 in. Front Clearance: 36 in. Quantity Steam Outlets: 1 Left Clearance: 0 in. Fill Rate: 0.2 GPM Right Clearance: 0 in. Drain Rate: 1.6 GPM Ceiling Clearance: 12 in. Nominal Capacity: 20 lbs/h Floor Clearance: 24 in. Rated Capacity: 22 lbs/h Supply Water: 0.5 in. Minimum Output Range: 4 lbs/h Drain Water OD: 1.18 in. Minimum Water Pressure: 30 psig Condensate Return: 0.38 in. Header mini SAM-e 24", 3" ctr, 0.875" tube Nominal Capacity: 210 lbs/h Length: 23.1 in. RECEIVED 18.03.2021 211 West Hopkins o s 72V/2 0 21 ASPEN BUILDING DEPARTMENT -~condair Psychrometric Diagram Outside: 0 °F/62 % Mixing point: 54 °F/51 % Before humidification: 55°F/49% After Humidification: 55°F/64 % Inside: 72 °F/35% so e0 **N4k:- kViA‘V 1 IA 4,4. 1,14avv4 .w.N ti ,,/ _ 4%.*,_,,,,,,, ... v ,,, ,, k kV.itkkla*,, k% %k\ V 39 e ' il Aktkr a*::i‘,t7Z41A,Akikk6'%k4‘*‘*014kA" h, l, 72 NkV4 50,a .4 4!t►\ .: `� 4 �\1�`*\:',oi .VAtt•` `�,\ik,.%.•� ` �, i s ...vo.. .t.:• s4N-*,„,,,,,t4.k. ,., , t, , ‘ ',A,A*4„- o 4:4130*"16.:460i* ...:,,Si....IC. N.N1114:a. jk,VtiklikkVk ,Nitok 1...Ilk ,„,,,,.§: s.„..:voll i 1 I 1 1 1 1 40 00 60 70 80 90 100 11 0 1 20 130 1 40 Dry bulb temperature-deg F Al - EL (ELN_020) Description Nortec EL Series Electrode Steam Humidifiers An electrode humidifier that produces sterile steam at atmospheric pressure from potable water. To generate steam an electrical current is passed through the dissolved minerals in potable water. The result; the water heats itself offering the highest energy efficiency of any steam humidifier. Utilizing the patented P+I Auto- Adaptive Control, the system automatically adjusts to incoming potable water conditions optimizing water usage. In turn, energy is conserved due to low hot water drain rates. Minerals removed during steam generation process accumulate in a disposable cylinder. Replacing the cylinder is quick, easy and does not require any scraping or descaling chemicals. The intelligent control system maintains steam generation efficiency until the end of the cylinder life. Replacing the cylinder returns the humidifier to a like new condition. Steam produced by the Nortec EL can be introduced into a duct or air handler using a short absorption manifold (SAM-e)or single tube distributor(ASD, BSD, CSD)with the Nortec EL DUCT model. For direct space applications steam can be distributed by using a built-on blower pack (Nortec EL SPACE model - Blower Pack included with this model) or a remote mounted blower pack.A remote mounted blower pack may be powered by the humidifier itself(Nortec EL RM model - Blower Pack not included with this model). FEATURES • Touchscreen controller with intuitive color user interface. • Standard BMS communication protocols BACnet IP, BACnet MSTP (Slave only) and Modbus. Lonworks and BACnet BTL options available. • Standard embedded web interface for easy configuration and remote monitoring from any computer with a web browser. RECEIVED 18.03.2021 211 West Hopkins 057219/2021 ASPEN BUILDING DEPARTMENT --?condair Zone List QMA QoA DBOA RHOA DBBH RHBH DBAH RHAH DBSD RHsD WDuct HDuct HTOT Absorption Zone Tag % % % % % Location Tech HUM-1 1580 25 0 62 55 56 55 73 72 40 26 12 11 0.35 In Duct Electrode Steam HUM-2 2010 25 0 62 55 49 55 64 72 35 32 12 12 0.29 In Duct Electrode Steam ()MA=Mixed Air Volume QoA=Outside Air DBOA=Outside Air Design Dry Bulb Temperature RHOA=Outside Air Design Relative Humidity DBBH =Before Humidification Dry Bulb Temperature RHBH=Before Humidification Relative Humidity DBAH =After Humidification Dry Bulb Temperature RHAH=After Humidification Relative Humidity DBSD=Space Design Dry Bulb Temperature RHSD=Space Design Relative Humidity WDuct=Duct Width HDuct=Duct Height HTOT=Total Humidification Absorption =Absorption Distance RECEIVED 05/21/2021 ASPEN BUILDING DEPARTMENT MAU-1 - House Make Up Air Unit Specification Sheet - EM-ME/MF/MG* Packaged Electric Make-Up Air STANDARD EQUIPMENT • Models available in 900,1050,and 1200 CFM • LCD display provides status and temperatures • Voltage-240/208VAC,single phase or208VAC,three phase -Real time estimated CFM • WarmFlo®Digital Proportional Element Modulation -Desired target temperature • Inlet and outlet digital temperature sensors for precise set points -Incoming and supply temperature • Integrated powered inlet damper • LO and HI temperature set point ranges,20°F to 55°F and 60°F to 90°F • Washable aluminum mesh filter • Hi-limits,automatic and manual reset • Current transformer technology for full interlock with exhaust systems . Unique design allows for simplified installation • Included CT detects LO/MED/HI exhaust fan levels • Listed for horizontal or vertical installation • Three speeds,auto adjust based on CT input • Can be easily wall-hung • Three CT inputs available for multiple fan applications • Includes chain for suspended installations • Multiple control inputs(i.e.end switches,zone valves,etc.) • Best in the industry warranty: • Easy programming for multi-speed kitchen exhaust fans -20-year finned rod element warranty • Multiple interfacing options to external controls -2-year parts warranty • Thermostat end switch connection point • Made in the USA TEMPERATURE RISE & CFM CHART- Selecting the best model for your application: 1 Choose your desired temperature rise(this is the difference between the coldest design day temperature and desired duct air temperature). 2 Move across the chart from your desired temperature rise to the CFM required(you may have to select a model with a higher CFM and adjust down to your required CFM at installation). Example: In an application where your coldest day averages 0°F and you require 50°F duct air,choose 50°F temperature rise. If you require 500 CFM you would select the MD 10. kW 4 1 1.6 5 7.2 10 15 20 14.4 21.6 CFM CFM CFM CFM CFM CFM CFM CFM CFM 80°F 39 71 197 277 395 604 I 790 553 869 70°F 45 81 225 325 451 677 903 632 993 po H 60°F 53 95 260 379 526 790 1053 737 1160 _ 50°F 63 114 316 455 632 948 1264 885 N/A a 40°F 79 158 395 568 790 1185 N/A 1130 N/A rx 30°F 105 168 526 758 1053 N/A N/A N/A N/A SPECIFICATIONS Model kW Btu/h Amps Internal Motor Motor Phase Voltage CFM Max Fuse/ Duct Weight CB FLA HP Max Static HACR Connection EM-ME15-240-1-14 15/11.3 51182/38386 62.5/54.1 60A+30A 1.5 1/4 1 240/208 900 .50 90 14" EM-ME10-240-1-14 10/7.5 34121/25591 41.7/36.1 N/A 1.5 1/4 1 240/208 900 .50 60 14" EM-ME05-240-1-14 5/3.8 17060/12795 20.8/18.0 N/A 1.5 1/4 1 240/208 900 .50 30 14" EM-ME00-240-1-14 0 0 0 N/A 1.5 1/4 1 240/208 - 900 14" EM-ME14-208-3-14 14.4 49134 40.0 50A 1.5 1/4 3 208 - 900 .50 50 14" EM-ME10-208-3-14 9.6 32756 26.6 N/A 1.5 1/4 3 208 - 900 .50 35 14" EM-ME05-208-3-14 4.8 16378 13.3 N/A 1.5 1/4 3 208 900 .50 20 14" I EM-MF15-240-1-14 15/11.3 51182/38386 62.5/54.1 60A+30A 1.5 1/4 1 240/208 1050 .50 90 14" 1 EM-MF10-240-1-14 10/7.5 34121/25591 41.7/36.1 N/A 1.5 1/4 1 240/208 1050 .50 60 14" EM-MF05-240-1-14 5/3.8 17060/12795 20.8/18.0 N/A 1.5 1/4 1 240/208 1050 .50 30 14" EM-MF00-240-1-14 0 0 0 N/A 1.5 1/4 1 240/208 - 1050 14" EM-MF14-208-3-14 14.4 49134 40.0 50A 1.5 1/4 3 208 - 1050 .50 50 14" EM-MF10-208-3-14 9.6 32756 26.6 N/A 1.5 1/4 3 - 208 - 1050 .50 35 14" EM-MF05-208-3-14 4.8 16378 13.3 N/A 1.5 1/4 3 - 208 - 1050 .50 20 14" EM-MG20-240-1-14 20/15 68242/51182 83.3/72.1 60A+60A 3.3 - 1/2 1 240/208 1200 .50 120 14" EM-MG15-240-1-14 15/11.3 51182/38336 62.5/54.1 60A+30A 3.3 1/2 1 240/208 1200 .50 90 14" EM-MG10-240-1-14 10/7.5 34121/25591 41.7/36.1 N/A 3.3 1/2 1 240/208 1200 .50 60 14" EM-MG05-240-1-14 5/3.8 17060/12795 20.8/18.0 N/A 3.3 1/2 1 240/208 - 1200 .50 30 14" EM-MG00-240-1-14 0 0 0 N/A 3.3 1/2 1 240/208 - 1200 14" EM-MG22-208-3-14 21.6 73702 60.0 50A+30A 3.3 1/2 3 208 - 1200 .50 80 14" EM-MG14-208-3-14 14.4 49134 40.0 50A 3.3 1/2 3 - 208 - 1200 .50 50 14" EM-MG07-208-3-14 7.2 24567 20.0 N/A 3.3 1/2 3 208 1200 .50 25 14" cETI► us ('if� ELE ,I ('� INDUS � YED Intertek • Monticello,Minnesota All specifications subject to ELECTRO INDUSTRIES STANDARD TERMS 800.922.41A n 1/G n 0 n 1 AND CONDITIONS,download at www.electromn.com/terms.pdf. www.electrom G G 5/21/2019 EL923 ASPEN BUILDING DEPARTMENT Installation Specifications (Reference Installation &Operating Instructions, EI916 or EI917) This product is designed for zero clearance,but use the following mounting and spacing criteria: 1. Unit can be installed vertically or horizontally. When vertical,inlet must face down. 2. When using CT doughnut,use Class II low voltage wiring methods to connect CT to Make-Up Air unit. 3. Make mounting provisions for a 1"air space at the top. 4. The sides,any location,can be in direct contact with wood framing materials. 5. No materials shall be in contact with the cabinet housing which has a flame point less than wood,300°F(150°C). 6. Product shall be installed in a conditioned space only. 7. Heating elements are locked out when entering air temperature is>55° F(12.8°C). MAKE-UP AIR IMMI .1§ el. I LI o 221' / Electro Industries ��44 Al 0 ro nKe-uvAIR o%,� o 0 0 k. • • D 173 DETAIL A 014" 4 MALE DUCT 0 A 01 38i„ 9 1 4 01.125 x 0.875 46 16 DOUBLE KNOCKOUT 378 • 1 —, 014" MALE DUCT MODELS EM-ME*, MF* &MG* RRT-ev.K 089i19 17, , 1 1 'N1 Sheet 4 of 4 RECEIVED 05/21/2021 ASPEN BUILDING DEPARTMENT UH-1 - House Garage Unit Heater REZNOR Revision: I-UBX-UBZ-UDX-UDZ (03-21) 1034344-0 Supersedes: — (Original Version) UNIT HEATER INSTALLATION/OPERATION/MAINTENANCE MODEL UBX: STANDARD POWER VENT BLOWER TYPE MODEL UBZ: SEPARATED-COMBUSTION BLOWER TYPE MODEL UDX: STANDARD POWER VENT FAN TYPE MODEL UDZ: SEPARATED-COMBUSTION FAN TYPE 11111 z N W DANGER 0 FIRE OR EXPLOSION HAZARD • Failure to follow safety warnings exactly could result in serious injury, death, or property damage. • Improper installation,adjustment,alteration,service,or maintenance can cause serious injury, death, or property damage. • Installation and service must be performed by a qualified installer,service agency,or the gas supplier. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. �y DO NOT DESTROY. PLEASE READ CAREFULLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. 05/21/2021 ASPEN BUILDING DEPARTMENT GENERAL INFORMATION—CONTINUED Dimensions—Continued Table 5. Dimensions—Models UDX and UDZ Dimension(See Figure 3) Unit A B C D E F G H J K M NPQR S T Size InnhAR( 1/1R)(mm( 2)) 030, 13-3/4 27 10 13-13/16 29-3/4 25-9/16 6 5-15/16 3-1/2 3-11/32 17-3/8 1-9/16 4-9/32 13 9-9/16 3-3/4 2-15/16 045 (349) (686) (254) (351) (756) (649) (152) (151) (89) (85) (441) (40) (109) (330) (243) (95) (75) 060 16-3/4 27 13 13-13/1632-23/3225-9/168-11/165-15/16 6 3-11/32 17-3/8 1-9/16 4-9/32 13 9-9/16 4-1/16 2-15/16 (425) (686) (330) (351) (831) (649) (221) (151) (152) (85) (441) (40) (109) (330) (243) (103) (75) 075 16-3/4 27 13 13-13/1631-29/3225-9/168-11/165-15/16 6 3-11/32 17-3/8 1-9/16 4-9/32 13 9-9/16 4-1/16 2-15/16 (425) (686) (330) (351) (810) (649) (221) (151) (152) (85) (441) (40) (109) (330) (243) (103) (75) 100 24-3/4 27 21 13-13/16 34-9/32 25-9/16 15-5/16 5-15/16 8-29/32 3-11/32 17-3/8 1-9/16 4-9/32 13 9-9/16 5-15/32 2-15/16 (629) (686) (533) (351) (871) (649) (389) (151) (226) (85) (441) (40) (109) (330) (243) (139) (75) 125 24-3/4 27 21 13-13/16 34-9/32 25-9/16 15-5/16 5-15/16 8-29/32 3-11/32 17-3/8 1-9/16 4-9/32 13 9-9/16 5-15/32 2-15/16 (629) (686) (533) (351) (871) (649) (389) (151) (226) (85) (441) (40) (109) (330) (243) (139) (75) 150, 20-1/8 38-3/16 16 23 48-7/16 40 9-5/8 8-5/16 5-3/8 6-1/2 25-11/16 1-13/32 8-1/8 22-3/16 16-3/8 5-1/2 4-1/4 175, (511) (970) (406) (584) (1230) (1016) (244) (211) (137) (165) (652) (36) (206) (564) (416) (140) (108) 200 225, 26-1/8 38-3/16 22 23 48-7/16 40 13-1/16 8-5/16 9 6-1/2 25-11/16 1-13/32 8-1/8 22-3/16 16-3/8 8-1/16 4-5/16 250 (664) (970) (559) (584) (1230) (1016) (332) (211) (229) (165) (652) (36) (206) (564) (416) (205) (110) 300, 34-1/8 41 30 23 48-29/32 40 17-1/16 8-1/2 11 7-5/16 27-11/161-13/32 8-1/8 22-3/16 16-1/4 11-9/16 4-1/2 400 (867) (1041) (762) (584) (1243) (1016) (433) (216) (300) (186) (703) (36) (206) (564) (413) (294) (114) Clearances Units must be installed so that the clearances listed in Table 6 are provided for with regards to combustion air space, inspection, and service and for proper spacing from combustible construction. Clearance to combustibles is defined as the minimum distance from the heater to a surface or object for which it is necessary to ensure that a surface temperature of 90°F (50°C) above the surrounding ambient temperature is not exceeded. Refer to the dimensions listed in Table 4 and Table 5 and shown in Figure 2 and Figure 3 when determining clearances to combustibles. Table 6. Clearances to Combustibles Unit Size Heater 030-125 150-400 Surface Minimum Clearance(Inches(mm)) Top 1 (25) 4(102) Flue connector 6(152) 6(152) Access panel 18(457) 18(457) Non-access side 1 (25) 2(51) Bottom* 1 (25) 1 (25) Rear*" 18(457) 18(457) *Suspend the heater so that the bottom is a minimum of 5 feet(1.5 meters)above the floor. **Measure rear clearance from the fan motor. Weights 0 WARNING 0 Check the supporting structure to be used to verify that it has sufficient load carrying capacity to support the weight of the unit. Suspend the heater only from the threaded nut retainers or with a manufacturer-provided kit. Do NOT suspend from the heater cabinet. NOTE: For unit shipping weight, contact an authorized Factory Distributor. Before suspending the heater, ensure that the supporting structure to be used has sufficient load-carrytn4Capacity, r,0,, to support the weight (refer to Table 7) of the unit. 05/21/2021 10 I-UBX-UBZ-UDX-UDZ(03-21)10IN BUILDING DEPARTMENT Table 7. Unit Weights Unit Size Model 030 045 060 075 100 125 150 175 200 225 250 300 350 400 Pounds(kg) UBX 84 89 102 108 168 171 300 320 320 385 400 458 494 506 (38) (40) (46) (49) (76) (78) (136) (145) (145) (175) (181) (208) (224) (230) UBZ 85 90 103 109 169 172 301 321 321 386 401 459 495 507 (39) (41) (47) (49) (77) (78) (137) (146) (146) (175) (182) (208) (225) (230) UDX 57 62 71 76 101 106 178 193 193 211 223 277 303 316 (26) (28) (32) (34) (46) (48) (81) (88) (88) (96) (101) (126) (137) (143) UDZ 58 63 71 77 102 107 179 194 194 212 224 278 304 317 (26) (29) (32) (35) (46) (49) (81) (88) (88) (96) (102) (126) (138) (144) Combustion Air Requirements O WARNING • Do not install a unit in a confined space without providing wall openings leading to and from the space. • Unit heater models UBX and UDX are designed to take combustion air from the space in which the unit is installed and are not designed for connection to outside combustion air intake ducts. Connecting outside air ducts voids the warranty and could cause hazardous operation. • For UBZ and UDZ models, refer to the combustion air requirements in the venting instructions listed in Table 1. • UBX and UDX models must be supplied with the air that enters into the combustion process and is then vented to the outdoors. Sufficient air must enter the equipment location to replace that which is exhausted through the heater vent system. • In the past,the infiltration of outside air assumed in heat loss calculations(one air change per hour)was assumed to be sufficient.However,current construction methods,which use more insulation,vapor barriers,tighter fitting and gasketed doors and windows,weather-stripping,and/or mechanical exhaust fans,may now require the introduction of outside air through wall openings or ducts. • Under all conditions, enough air must be provided to ensure there will not be a negative pressure condition within the equipment room or space. • Requirements for combustion air and ventilation air depend upon whether the unit is located in a confined or unconfined space. A confined space is defined as a space whose volume is<50 cubic feet per 1,000 BTUh of the installed appliance input rating. An unconfined space is defined as a space whose volume is >50 cubic feet per 1,000 BTUh of the installed appliance input rating. • For confined space installation of UBX and UDX models (including those with CV option), provide openings (depending on the combustion air source)near the floor and ceiling for ventilation and air for combustion,as shown in Figure 4 and as listed in Table 8. NOTE: For further details on supplying combustion air to a confined space, refer to the National Fuel Gas Code ANSI Z223.1 a (latest edition). IIIMMEMMEMEMMIMEMIMMEMM;;I)bh. = c A � 1:4 CONFINED SPACE - C A B RECEIVED Figure 4. Confined Space Combustion Air Openings (Refer to Table 8) 05/21/2021 I-UBX-UBZ-UDX-UDZ(03-21) 1034344-0 ASPEN BUILDING DEPARTMENT GENERAL INFORMATION-CONTINUED Acoustical Considerations-Continued Table 11. Technical Data for UDX and UDZ Models (Unit Sizes 030-125) Parameter Unit Size Unit of 030 045 060 075 100 125 Measurement 30,000 45,000 60,000 75,000 105,000 120,000 BTUh Input heating capacity - - 8.8 13.2 17.6 22.0 30.8 35.2 kWh Thermal efficiency 82 83 83 83 % 24,600 37,350 49,800 62,250 87,150 99,600 BTUh Output heating capacity 7.2 10.9 14.6 18.2 25.5 29.2 kWh Gas connection,natural2 1/2 1/2 1/2 Gas connection,propane2 1/2 1/2 1/2 Inches Vent connection diameter3 4 4 4 Combustion air inlet diameter(UDZ models)3 4 4 4 Control,24V 1.0 1.0 1.0 Full load amps, 115V 1.9 2.4 2.4 3.7 4.3 5.6 Amps Maximum overcurrent protection(115V)4 15 15 15 Normal power consumption(UDX models) 109 155 155 217 276 354 Watts Normal power consumption(UDZ models) 109 155 155 228 292 370 Discharge air temperature rise 50 55 60 60 °F 456 629 769 961 1345 1537 cfm Air volume 12.9 17.8 21.8 27.5 36.7 45.9 Meter3/minute a air opening area 0.96 1.25 2.01 Foot2 Discharge p g 0.09 0.12 0.19 Meter2 Output velocity 475 656 616 770 668 763 fpm 145 200 188 235 204 233 Meter/minute Open fan motor size 0.02 0.03 0.03 0.06 1/30 1/20 Enclosed fan motor size 0.06 0.06 1/4 Horsepower Fan motor speed 1550 1550 1050 rpm Fan diameter 10 12 16 Inches Sound level @ 15 feet 40 40 49 54 55 dba 1CSA ratings for elevations up to 2,000 feet. 2Size shown is for gas connection to a single-stage gas valve-not supply line size. 3Smaller and/or larger vent and combustion air pipe diameters may be permissible. Refer to appropriate venting instructions listed in Table 1. 4MOCP=2.25 x(largest motor FLA)+smallest motor FLA Answer is rounded to the next lower standard circuit breaker size. RECEIVED 05/21/2021 14 I-UBX-UBZ-UDX-UDZ(03-21) 10 * 1 N BUILDING DEPARTMENT WH- 1 ,2 - House Water Heaters RESIDENTIAL GAS WATER HEATERS The Lochinvar 35-50 Series gas fired, tank type 35-50 SERIES water heaters are designed to provide ease of installation, low stand-by loss and years of GAS MODELS dependable service. The 35-50 Series features seven models for residential installations and six models for commercial installations, available in natural or L.P. gas. OUTSTANDING FEATURES • Stainless Steel Construction—The tank and helical heat IA)chimar exchanger are made from 444 Stainless Steel for excellent corrosion resistance without need of anode rods. • 96%Thermal Efficiency—Operating up to 96%Thermal Efficiency,the 35-50 Series employs an internal helical heat exchanger which keeps the flue products in the appliance longer for maximum heat transfer. • Whisper Quiet Operation— Ultra quiet blower and burner to g minimize noise. r, • Advanced Electronic Controls— Large touchscreen display with -e precise temperature control and advance diagnostics. 160°F ENERGY STAR max setpoint for residential models; 180°F max setpoint for commercial models. • Power Direct Vent Design—Vent in PVC, CPVC or Polypropylene for low cost installations, sidewall or rooftop. Vent 2" up to 52 equivalent feet and vent 3" up to 130 equivalent feet. • Ultra Low NOx Modulating Gas Burner—Complies with SCAQMD Rule 1146.2 and other Air Quality Management • Districts with NOx emissions less than 14ng/j. • Standards and Certifications— Design certified by CSA International per the requirements of ANSI Z21.10.3 / CSA 4.3 standards. Meets UBC, CEC and ICC National codes. Meets thermal efficiency and standby loss requirements of the U.S. Department of Energy and ASHRAE/IEC 90.1. • Temperature and Pressure Relief Valve— Factory installed. • Residential Warranty- 10-year limited tank and 10-year limited Meets ASHRAE Energy parts. Efficiency Standards • *1 Year limited tank and parts warranty when installed in a os,F, commercial application laLIM CERTIFIED.. ``���0 a lb,„„d e xo» • Commercial Warranty3-year limited tank and 1-year limitedparts. T,`", o - y y WATER QUALITY coNrENr See warranty for details. - • RECEIVED AOlt Locbinvar1 HIGH EFFICIENCY BOILERS &WATER HEATERS ASPEN BUILDING DEPARTMENT DIMENSIONS & SPECIFICATIONS TOP iIiolll "—TBP Valve , O Exhaust Outlet Additional 0 Hot Water Outlet Side Taps Cold A Air Inlet Water D E Water Inlet Gas 7Cold Connection 0Alr Inlet Additional Exhaust Outlet Side Taps % T&P Gas Supply �� Condensate Valve rain YI�� � � D j Connection C F H LEFT SIDE FRONT TOP Model Btu/hr Gallon GPH @ 1st Hour Thermal Gas Water Vent Ship Number Input Cap. 90°F Rise Recovery Efficiency A B C D E F Conn Conn Diameter Wt. 35-50 Series,Residential SWN100-035 100,000 34 129 156 96% 48-1/2" 22" 15-3/4" 40-1/2" 41" 6-1/2" 1/2" 1" 2"or 3" 150 SWN130-035 130,000 34 165 192 96% 48-1/2" 22" 15-3/4" 40-1/2" 41" 6-1/2" 1/2" 1" 2"or 3" 150 SWN150-035 150,000 34 190 217 94% 48-1/2" 22" 15-3/4" 40-1/2" 41" 6-1/2" 1/2" 1" 2"or 3" 150 SWN130-050 130,000 50 165 205 95% 62-1/2" 22" 15-3/4" 54-1/2" 55" 6-1/2" 1/2" 1" 2"or3" 176 SWN150-050 150,000 50 190 230 95% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 2"or3"" 180 WH-1,2 SWN175-050 175,000 50 222 262 96% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 3" 180 SWN199-050 199,000 50 253 293 96% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 3" 180 35-50 Series,Commercial 01130-035 130,000 34 165 192 96% 48-1/2" 22" 15-3/4" 40-1/2" 41" 6-1/2" 1/2" 1" 2"or 3" 150 01150-035 150,000 34 190 217 94% 48-1/2" 22" 15-3/4" 40-1/2" 41" 6-1/2" 1/2" 1" 2"or 3" 150 SCN130-050 130,000 50 165 205 95% 62-1/2" 22" 15-3/4" 54-1/2" 55" 6-1/2" 1/2" 1" 2"or 3" 176 SCN150-050 150,000 50 190 230 95% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 2"or 3" 180 SCN175-050 175,000 50 222 262 96% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 3" 180 SCN199-050 199,000 50 253 293 96% 62-3/4" 22" 15-3/4" 55-3/4" 56-1/4" 6-1/2" 1/2" 1" 3" 180 * In the model number,"N"indicates natural gas;replace"N"with"L"to indicate LP gas models. The SWN100-035 model has a 33 gallon rated storage capacity,a 0.90%UEF rating and a 170 GPH First Hour Rating. FOR EASE IN ORDERING BY MODEL NUMBER SC N 199 50 '� '$. This is a natural gas 35-50/series water heater.It has standard construction,199,999 Btu/hr,and 50 gallon storage capacity. ® EahinvddoxS For technical information call 800-722-2101. TFp R�V "Lochinvar 300 Maddox Simpson Parkway Lebanon,889.8900/F:315.5 reserves the right to make product changes o improvements P.615.889.8900/F.615.547.1000 HIGH EFFICIENCY BOILERS&WATER HEATERS w3©®0 Lochinvar.com without prior notice. 0 5/2 1/2 O 2 1 SWSC-01 (New) (Website Update 9/20) ASB-2.5M-12/17 Printed in U.S.A. ASPEN BUILDING DEPARTMENT 211 West Hopkins Mechanical Documents Cabin RECEIVED 05/21/2021 ERV-2 - Cabin Energy EI aides Recovery Ventilator aides RESIDENTIAL 1������ • ERV Iltagad E150-TRG • ENERGY RECOVERY VENTILATOR 125 CFM at 0.20 in.w.g (ESP) c ETA US ° 2100 Made in 5 year 5 year 1�1 V Canada Warranty Warranty Intertek CERTIFIED lI C22.2 no118 (Canada Only) UNIT CORE LJL 1812 PRODUCT DESCRIPTION Compact size, large performance—the E150-TRG energy )NRecovery Core recovery ventilator produces approximately 125 CFM at �`O! Material: High-latent-transfer membrane 0.2 in w.g. (ESP) and recovers sensible and latent heat through its high-latent-transfer core. The E150-TRG has Casing been thoughtfully engineered for simple installation in and Material: Pre-painted 24-gauge galvanized steel spacious houses. Duct Connections:0 5" (0 127 mm) Insulation: Molded EPS Width: 23-1/8" (587 mm) Height: 16-3/4" (425 mm) Recommendation : Depth: 12-3/8" (314 mm) Ideal for homes from 1500ft2 to 2500ft2 Weight: 32 lbs (15 kg); Shipping Weight: 40 lbs (18 kg) Supply Damper: Motorized Mounting KEY FEATURES Suspended by chains with vibration-isolating springs Electronically and independently adjustable supply and exhaust blowers Wall-mounting accessory available (P/N: 608575) (FLEXControl) 0-10 Electrical requirement Gauge ports on the door for fast and reliable airflow readings VOLT 120 VAC, 60 Hz, 1.3 A, 156 W Cord Set: 48" (1219 mm)with ground Non-dust-loading backward-inclined impellers on totally enclosed motors ei Frost control Twist-in collars for easy flex-duct attachment Automatic timed recirculation, fifth port. Cycles controlled by a temperature sensor when outdoor Easy access to core and filters for cleaning temperature drops below 14°F (-10°C) Durable High Latent Transfer enthalpy core has exceptional moisture transfer for increased comfort and no drain required. Filters Recirculating defrost collar snaps into pre-punched area of FlLTIIATION Type : MERV 6 (P/N 612409) cabinet for ducting flexibility Option : high-efficiency MERV 13 (P/N 612410) Blowers RECEIVED VENTZATIUN Motorized impellers (backward-inclined) 05/21/2021 ASPEN BUILDING DEPARTMENT Dimensions Controls Low voltage dry contact (24VAC) for interlock TOP VIEW - with heating/cooling systems. EXHAUST SUPPLY AIR AIR Digital Multifunction Control ��\ (#611242) and (#611242 FC) �� 0 5"Typ. (0 127 mm) — ra /I it (i) 1 (� J LCD Electronic Multifunction RECIRCULATED Control AIR � (P/N611227) ®A OUTSIDE / RETURN ACCESS ®� AIR AIR PANEL 20/40/60 Minute Timer(P/N m SIDE VIEW I FRONT VIEW - 611228) I - Ui A 2-1/4" Yiili `iiiii �r m WA.I ra, (57 mm) 1r l � 1� .N 1 �^ Speed Control (Low/Intermittent/High) ti a (P/N 611229) (483 mm) 16-3/4" Mode Control (425 mm)I - (Recirculation) (P/N 611230) o r o /e _ r y 0 0 I ® ® 1 (k 12-3/8" 2-1/4" {y{ 23-1/8" 314 mm) (57 mm) (587 mm) 25-3/8" } (645 mm) Performance E15O-TRG Ventilation Performance Outside Air Net Airflow Adjusted Latent Adjusted External Static Pressure in.w.g.(Pa) Temperature Power Sensible Sensible Recovery/ Total o 0 0 0 co Consumed Recovery Recovery Moisture Recovery o 0 0 41. in a` bo O °F °C CFM Us (1M Efficiency Efficiency Transfer Efficiency o J N w — — — — N NJ rV V7 V 0 NJJ rn V O N O In O lsi O to O to O U9 Heating 40(70) ..•••.•.......•.•. 32 0 51 24 42 68% 73% 57% t 60(100) II................. E ■■■■■■■■■■■■■■PM■■ 32 0 62 29 62 66% 72% 55% 80(135) ■■■■■■■■■■■■■ d■■■ 32 0 103 49 98 58% 64% 45% ,_ ■■■■■■■■■■MEA■■■■■ 100(170) ■■■■■■■■■R ■■■■■■■ 13 -25 50 24 64 61% 64% 55% o MENNIMENEMINEMIIMMINE ■■■■■,,.■■■■■■■■■■ Cooling Q 120(205) ■■mmai■■■■■■■■■■■■ 95 35 49 23 42 45% 52% 140(240) •• ••••••••••••••• Project: Architect: Location: Engineer: Model#: Contractor: Quantity: Comments: Submitted By: Date: 1 i D You For more information, contact your Aides sales advisor,visit aldes-na.com, call 1.800.255.7749, or find us on in f 0 05/21/ 021 ©2020 American ALDES Ventilation Corporation and©2020 ALDES Canada.El50-TRG_1220.Aides reserves the right to modify its products at any time to introduce new technologies. •Of ASPEN BUILDING DEPARTMENT F-3 / CU-3 - Cabin Heat Pump LENNOX System Project Submittal Tag: HP Cabin F1 Condenser: XP25-060-230 Air Handler: CBA38MV-060 UNIT OVERVIEW AHRI Reference-201930689 Gross Cooling Net Cooling Supply EAT LAT SEER Ttl/Sens Ttl/Sens Air Flow ESP/TSP DB/WB DB/W Voltage EER Tons _ (MBH) m (MBH) m (cfm) (in.WC) • (°F) 208V/1Ph 19.5 5.0 61.7/43.5 59.3/41.1 2,140 0.5/0.5 80.0/67.0 52.0/52.0 60Hz 12.5 COOLING ' n` Cooling Performance Temperatures(DB/WB°F) Gross Cooling(Ttl/Sens) 61.7/43.5 MBH Ambient 82.0 Net Cooling(Ttl/Sens) 59.3/41.1 MBH Condenser Ambient Coil Moisture Removal 17.08 lb/hr Entering 80.0 67.0 Leaving-(Coil) 52.0 52.0 Leaving-(Unit) 53.6 53.6 ARI Performance Compressors I Refrigerant Condensate Drain _ ARI Cooling 58,000.0 MBH Cooling Stages Variable Type R-410A Qty 2 Compressor Qty 1 Cond Suction Line 1 1/8 Size 0.75 in. Cond Liquid Line 3/8 Pipe Thread fpt Coil Suction Line 7/8 Coil Liquid Line 3/8 HEATING Heating Performance Temperatures(DB/WB°F) Output 64.1 MBH Ambient 0.0 0.0 HP Output(High/Low) 54.5/36.0 MBH Entering 0.0 HP Design -15.0 HP Output @ Design 16.3 MBH Leaving 29.7 HSPF 10.0 HP Heat Rise 7.0 Electric Heat Size 25 kW Heat Rise 29.7 SUPPLY FAN - Air Flow(cfm) Supply Fan Air Resistance(in.WC) Supply 2,140 Nominal Power 1.00 hp Total 0.50 Outdoor Required Power 1.00 hp Ext Supply 0.50 Return Drive Type ECM Variable Speed Constant Volume Supply Fan Total Speed Orientation M ELECTRICAL Condenser Air Handler Voltage 208V/1 Ph/60Hz Voltage 208V/1 Ph/60Hz Elec Heat Voltage 208 Volt 1 Phase MCA 35 amp MCA(Ckt 1/2/3) 46/38/38 amp MOCP 50 amp MOCP(Ckt 1/2/3) 50/40/40 amp Condenser Oper Range-Nom Volt +/-10% AHU FLA 4.1amp Oper Range-Nom Volt +/-10% Single Point Power MCA 122 amp Single Point Power MOCP 125 amp ADDITIONAL DATA"- W Condenser Air Handler Dimensions 39.50 in.x 35.50 in.x 47.00 in. Dimensions 24.62 in.x 21.25 in.x 62.50 in. Total Weight 335 lb Total Weight 199 lb RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 14 of 1ASPEN BUILDING DEPARTMENT LENNIJXJ Project Submittal Tag: HP Cabin F1 Field Installed Accessories Catalog Number Qty Description 16V98 1 25 KW Electric Heat 208/230 1 Ph with CB Field Installed 21 H39 1 Single Point Power Source Control Box Field Installed Product Features Cabinet Heavy gauge galvanized steel cabinet Copper Tube/Aluminum Fin Coils Multi-Position Capability,shipped from factory for upflow or horizontal app Heavy gauge galvanized steel cabinet Cooling System Non Chlorine,Ozone Friendly Refrigerant,R410A High Pressure Switch(Manual Reset) Hi-Capacity Drier factory installed in liquid line Low Pressure Switch Twin Coils assembled in an"A"configuration Check and Expansion Valve is factory installed Variable Speed(VSM)Direct Drive Blower Motor Warranty Condenser Limited compressor warranty of 5 years for Residential Installations Condenser Limited warranty on all other covered components of 5 years Condenser See Limited Warranty Certificate included with unit for details Condenser Limited compressor warranty of 5 years for Non-Residential Installations Coil See Limited Warranty Certificate included with unit for details Coil Limited warranty on all other covered components of 1 year(Comm Use) RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 15 of'ASPEN BUILDING DEPARTMENT LENI$I1X) Project Submittal _ _--- UNIT SUPPORT ~ ,eiNIIIIIM MNal FEET \ EIVD�gr1�IN INIUMMUSlt11111 I M IIIIIIIIMINl 111111111 , o ' MYIIIIIIIIIIYNNIlu11I NIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIII11IINIIIIII ' 0 0 0 26-7/8 � ' IINMI li OI11IIIIIIIIIIINI11IIIIIIIIIII1 `429)4�' ` ' 'I� ,+111111 i 1 III IIIIIIIInlllllllllllllf) 0 " ���11 11MNIIUIUYI► NNNIUIfIIIUIIIg 8-3/4-.,„lig!' WIN NIJ1111111�rrrJr ( ) \ \J 3-314 (95) 4 3-1/8 30314 _ 4-5/8 (791 —Owal (117) TOP VIEW TOP VIEW BASE SECTION (Large Base) 39 1/2(1003) _ A 35 1/2(902) wek (Depth) (Width) DISCHARGE t AIR A 1'1 I �.. o-1 -HIGH VOLTAGE o- - = ELECTRICAL o= C - _'t . - INLET - = _ (024,036) o—_ o Li :—.— 4-1/2 \HIGH VOLTAGE o_ �—`��' o co (114)� ELECTRICAL o— 3 �� SUCTION LINE N INLET o— i _ _. — — INLET q g (048. ) o— ire _ �, — = _ — = - p A o I • — - LIQUID LINE v 16.518(422) LOW VOLTAGE o— I - =W._ _ — INLET (024 036) ELECTRICAL o_ — — 18 1!2(470) INLET o— 1 . -^�.- • • •• I l i -,- T T �t c J u 8(203) 4 1 1'`J SIDE VIEW ACCESS VIEW RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 16 of 1ASPE;N BUILDING DEPARTMENT LENNIJXDProject Submittal UPF LOW POSITION SUPPLY AIR DETAIL OF PIPING PLATE 3.4 OPENING iplir 1191 Ar 1-1/II (29) SUCTIONN LINE Al (11 11 O RAINS ON DENS ATE 3.4 3.4 LI OUI D\ / (H o+it onta4 (19) 11-1!1612811 1191 I LINE D—Ow .00- \ O 2 (5,1 O Din plan ( CON DENSATE , DRAINS(2) �) \ 5-318 I Upfld Dow rif r*1 (137) `�1� Dw.rdbr.l z3r4 UNE VOLTAGE LOW VOLTAGE / 17g1 0 INLETS INLETS (Top aid Left Side) (Top aid Right Side) / 13.4 TOP VIEW / L I") 3-1.2(891 J B IA t ( ) ; I _C—� �--{r,\ --71 / U II11111114 I\I I — / I- rnuu III.III.i G , OPTIONAL I r I I AIR FLOW( ELECTRIC r (BL OWE R)I ' HEAT I I r,Yelllddl / Note - Units are shipped in one piece but I—- -I / may be disassembled into two separate sections for ease of installation. 7 n7\ ----I ' For additional circuits,use the dimples I I 4/1 A I I locate the new knockouts. ,' PIPING I I , I SUCTION I COIL I PLATE\� / H UNE \ I I --- 4 '. LLI UID`V -- I • LME —41 R`..�I — FILTER FI LT ER _ I� �1 Lii Ret F Air 1.0_ Access 411 le R`tuEm I1 1 owl i sa (16) FRONT VIEW (i'SI j2A SIDE VIEW 1161 Model A B C D E F G H No. in mm in mm in mm in mm in mm in mm in mm in mm CBA38MV-0181024 49-1/4 1251 21-1/4 540 20-5/8 524 19-3/4 502 19 483 20 508 24-5/8 625 24-5/8 825 CBA3 BM V-030 CBA36h1V-038 51 1295 21-1i4 5 ��4C 518 575 19-3/4 502 21 533 20 508 26-3/8 670 24-5/8 625 CBA38MV 042 I58-1/2 1488 21-1/4 540 24-5/8 825 19-3/4 502 23 584 20 508 27-7/8 708 30-5/8 778 CBA3 BM V-048 CBA38MV-0?C 82-112 1588 21-1/4 540 24-5/8 825 19-3/4 502 23 584 20 508 27-7;8 708 34-5/8 879 RECEIVED 05/21/2021 Project Name:211 West Hopkins Page Quote:83354 17 of'ASPEN BUILDING DEPARTMENT WH-3 - Cabin Water Heaters COMMERCIAL ELECTRIC WATER HEATERS 5 to 120 Gallon -ASME Construction COMPACT ASME HI-POWER ELECTRIC MODELS STANDARD FEATURES • Advanced Electronic Controls—LCD readout displays operational 111 and diagnostic information in words,not codes. Features Low Water Cutoff,Enable/ Disable Contacts, Element Sensing and Night Setback. At ochimur • Glass-Lined Steel Tank—The durable glass lining is fused to the tank at 1600°F to assure lasting protection against rust and corrosion while providing clean,clear hot water. ASME construction—150 psi working pressure on all models. • Powered Anode—Combined magnesium anode and powered anode provide extra protection from corrosion for long trouble- free service. a • Heating Element—Incoloy sheathed immersion type heats water faster,more economically. Low watt density, (75 watts/in2) • Energy Cut-Off—Shuts off electrical power to the elements should the water temperature in the tank reach 205°F. • ASME Temperature and Pressure Relief Valve— Factory supplied. • Non-CFC Foam Insulation—Superior material formulation provides uniform tank coverage with a thick blanket of insulating foam. This non-CFC polyurethane closed cell foam minimizes ~-- standby losses and maximizes heat retention. • Hinged Access Door—Provides easy access to electrical controls. • Immersion Thermostats with Contactors—Thermostat settings range from 80°-180°F and can be adjusted to"off"position. • 3 Year Limited Tank Warranty,1 Year Limited Parts Warranty See warranty for details OPTIONAL EQUIPMENT • Alarm on Any Failure Meets ASHRAE Energy • Temperature&Pressure Gauge Efficiency Standards • 4"X 6"Handhole Cleanout • ICC Control,BACnet and Modbus c). u�.�ICERTIFIED LOW O LEAD HLW • t a t3) Locbinvar1 HIGH EFFICIENCY BOILERS &WATER HEATERS ASPEN BUILDING DEPARTMENT Dimensions&Specifications Model Gallon Maximum Water Shipping Number Capacity kW A B C D Conn. Weight (H(X) W 005A 5 3 22" 16" 24" 4-1 4" 3 4" 82 (H(X)kW 010A 10 6 28-1/4" 18" 26" 5-1/4" 3/4" 116 (H(X)kW020A 20 18 31-3/4" 22" 28" 5-3/4" 3/4" 145 (H(X)kW 030A 30 24 43-1/4" 22" 28" 5-3/4" 3/4" 218 (H(X)kW 040A 40 36 54-3/4" 22" 28" 5-3/4" 3/4" 245 (H(X)kW 050A 50 90 66-1/4" 22" 28" 5-3/4" 3/4" 291 (H(X)kW065A 65 90 57-1/4" 26-1/2" 32-1/2" 11-1/2" 1-1/4" 344 (H(X)kW080A 80 90 58-1/4" 28" 35" 12-1/2" 1-1/4" 406 (H(X)kW 100A 100 90 70-1/4" 28" 35" 12-1/2" 1-1/4" 419 (H(X)kW 120A 120 90 70-1/4" 30-1/4" 37" 12-1/2" 1-1/4" 453 NOTE:Allow 24"clearance from front access panel for service and maintenance. FOR EASE IN ORDERING VOLTAGE SCHEDULE BY MODEL NUMBER T-208V/1 or3PH 3to24kW W-277V/1 PH 3to45kW C H X 36 040 A J 208V/1 PH 30 to 45 kW V 480V/1 PH 3 to 90 kW o oe> a c7 s��si K-208V/3PH 30to90kW X-480V/3PH 3to90kW �"7"I-- -70 9•7 P-240V/1 or 3 PH 3 to 54 kW Y-380V/3 PH 3 to 90 kW This heater is a Compact Hi-Power,480 A-240V/1 PH 60 kW Z-415V/3 PH 3 to 90 kW volt,3 phase,36 kW,40 gallon water B-240V/3 PH 60 to 90 kW M-575V/3 PH 3 to 90 kW heater with ASME construction. Amperage Table N 600V/3PH 3to90kW SINGLE PHASE THREE PHASE OUTLET kW 208V 240V 277V 480V 208V 240V 480V c G ° 3/4"NPT RELIEF 3 14.4 12.5 10.8 6.3 8.3 7.2 3.6 VALVE OPENING 6 28.8 25.0 21.7 12.5 16.7 14.4 7.2 9 43.3 37.5 32.5 18.8 25.0 21.7 10.8 I NO CONDUIT 12 57.7 50.0 43.3 25.0 33.3 28.9 14.4 OPENING 15 72.1 62.5 54.2 31.3 41.6 36.1 18.0 -. 18 86.5 75.0 65.0 37.5 50.0 43.3 21.7 24 115.4 100.0 86.6 50.0 66.6 57.7 28.9 30 144.2 125.0 108.3 62.5 83.3 72.2 36.1 HINGED 36 173.1 150.0 130.0 75.0 99.9 86.6 43.3 A ' ACCESS 45 216.3 187.5 162.5 93.8 124.9 108.3 54.1 DOOR 54 N/A 225.0 194.9 112.5 149.9 129.9 65.0 1 60 N/A 250.0 216.6 125.0 166.5 144.3 72.2 75 N/A N/A N/A 156.3 208.2 180.4 90.2 I ;4 D 90 N/A N/A N/A 187.5 249.8 216.5 108.3 B Note:All ASME models with an amp draw in excess of 120 amps receive factory installed internal fusing. 14- Note:Outlet connection for 5 thru 50 models 3/4"NPT. GPH Recovery Rate Outlet connection for 65 thru 120 models 1-1/4"NPT. INPUT Recovery Rate(GPH @°F Rise) kW Btu/hr 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F 3 10,239 41 31 34 20 17 15 13 12 11 10 10 9 6 20,478 82 62 49 41 35 31 27 25 22 21 19 18 9 30,717 123 92 74 62 53 46 41 37 34 31 28 26 12 40,956 164 123 98 82 70 61 55 49 45 41 38 35 15 51,195 205 154 123 102 88 77 68 61 56 51 47 44 _ 18 61,434 246 184 148 123 105 92 82 74 67 62 57 53 24 81,912 328 246 197 164 140 123 109 98 90 82 76 70 30 102,390 410 308 246 205 176 154 137 123 112 103 95 88 36 122,868 492 369 295 246 211 184 164 148 134 123 113 105 45 153,585 615 461 369 307 263 230 205 184 168 154 142 132 54 184,302 738 554 443 359 316 277 246 221 201 185 170 158 60 204,780 819 615 492 410 351 307 273 246 223 205 189 176 75 255,975 1,025 768 615 512 439 384 341 307 279 256 236 219 90 307,710 1,229 922 738 615 527 461 410 369 335 307 284 263 Lurhinvar,LLC For technical information call 800-722-2101.ea- 1• atiVED Lam .® 300N1addox 889.89 0/F:61090mpson reservesthe ri ht to make chan es I Lebanon,Tennessee 37090 g productg Cl5.889.8900/F:615.547.1000 without prior notice. HIGH EFFICIENCY BOILERS&WATER HEATERS ■ii ©®f=Lochinvar.com O r/71 /7 021 HPC-05 (Replaces HPC-04 8/18) (Website Update 2/21) ASB-1K-5/19-Printed in U.S.A. ASPEN BUILDING DEPARTMENT