Master Permit.211 W Hopkins Ave.0078-2021-BRES (10)
® KNIGHT FIRE TUBE BOILER HIGH EFFICIENCY BOILERS &WATER H EATERS Submittal Sheet KHBWHB-Sub-01 KNIGHT FIRE TUBE BOILERS - FLOOR AND WALL MOUNT MODELS Job Name: Location: n:- 211 West Hopkins Ave Aspen,CO Engineer: Agent/Wholesaler: IMEG —� Contractor: Type Gas: NG Model#: Equipment Tag(s): WHB155N B-1 JOB NOTES: > Four Pump Control 10 System Pump with Parameter for Continuous Snowmelt Boiler Operation Boiler Pump with Variable Speed Control Domestic Hot Water Pump Domestic Hot Water Recirculation > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting Separately Adjustable Space Heat/DHW Smart System Features Switching Times 0-10VDC BMS External Control Contact > Building Management System Integration 0-10 VDC Boiler Rate Output Contacts > Smart System Digital Operating Control 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Variable Speed System Pump Signal Input Multi-Color Graphic LCD Display w/Navigation 0-10 VDC Modulation Rate Output 0-10 VDC Signal to Control Variable Speed Boiler Pump Dial,Soft Keys and Loch-N-Link USB programming 0-10 VDC Input to Enable/Disable Call for Heat Modbus Contacts > Three Boiler Setpoint Temperature Inputs > Access to BMS Settings through Graphic LCD > Time Clock Plus Domestic Hot Water Prioritization Display > Data Logging > Built-in Cascading Sequencer for up to > High-Voltage Terminal Strip Hours Running,Space Heating 8 Boilers,with Cascade Redundancy 120 VAC/60 Hertz/1 Phase Power Supply Hours Running,Domestic Hot Water Multiple Size Boiler Cascade Three Sets of Pump Contacts Ignition Attempts Lead Lag Last 10 Lockouts Efficiency Optimization > Low-Voltage Terminal Strip Front End Loading Capability DHW Recirculation Pump Start/Stop > Maintenance Reminder 24 VAC Device Relay Custom Maintenance Reminder with > Outdoor Reset Control with Outdoor Air Sensor Configurable Proving Contacts Contractor Contact Information Programmable for Three Reset Temperature Inputs Flow Switch Contacts Installer Ability to De-activate Service Reminder > Programmable System Efficiency Optimizers Alarm on Any Failure Contacts > Low-Water Flow Safety Control&Indication SH Night Setback Runtime Contacts > Password Security DHW Night Setback DHW Thermostat Contacts Anti-Cycling 3 Space Heat Thermostat Contacts > Customizable Freeze Protection Parameters Outdoor Air Reset Curve System Sensor Contacts Ramp Delay DHW Tank Sensor Contacts Optional Equipment Modulation Factor Control Outdoor Air Sensor Contacts ❑CON•X•US Remote Connectivity Boost Temperature&Time Cascade Contacts ❑Modbus Communication ❑BACnet MSTP Standard Features El Flow Switch > 95%DOE AFUE Efficiency(55-285) > SMART SYSTEMTM Control ❑Low-Water Cutoff w/Manual Reset&Test > Modulating Burner with up to 10:1 Turndown** > Condensate Trap El Alarm Bell Direct Spark Ignition > ECM Variable Speed Boiler Circulating Pump El Concentric Vent Kit Low NOx Operation ❑Condensate Neutralization Kit > 110V Convenience Outlet > ASME Stainless Steel Heat Exchanger ❑BMS Gateway to LON or BACnet IP 30 PSI ASME Relief Valve > High Altitude Models Available > Top and bottom water connections(MNPT,WHB > Other Features El Multi Temperature Loop Control 55-285 Only) Automatic Reset High Limit ❑Sidewall Vent Termination > Vertical&Horizontal Direct Vent Adjustable High Limit w/Manual Reset ❑Wireless Outdoor SensoRECEi /E D PVC,CPVC,Polypropylene or SS Venting up to 100 ft. Zero Clearances to Combustible Materials El Gas Conversion Kit > Universal Vent Adapter 15-Year Limited Warranty(See Warranty for Details) > Firing Codes 0 5/21/2 0 21 Built-in Combustion Analyzer Port 5-Year Limited Parts Warranty ElM9 Standard Construction **5:1 on WH8399 ASPEN BUILDING DEPARTMENT ® FRONT LEFT SIDE IBHT G � Air Intake cill . � ./RE TUBE BO/L r -—- Gas hint Water Outlet�iIII tital°'TOP UI; , • .' r D Flue Vent Water Inlet AC o High Voltage Outlet o Electrical } C I��) A 43-3/8" E o Connection w 9 \-, f O g [ems — Low Voltage '. 9 Electrical fro 19" 1 I Connection IIV - I� F• n$ ! :•h Condensate f S e Drain K - 16"r LI '.:: , r i • . 1 . FLOOR MOUNT �v�CERTIFIED N I'� Input MBH Net Heating AHRI I Shipping Model Capacity Rating Gas Water Air Vent Weight Number Min Max AFUE% MBH MBH A B C D E F G H I I K Conn. Conn. Inlet Size (lbs.) (rJ KHB055N 8.3 55 95 51 44 3-1/2" 13-1/4" 6" 2-3/4" 37-2/3" 13-1/2" 8-1/3" 10-1/2" 15" 32-1/2" 8-1/3" 1/2" 1" 2" 2" 160 QJ KHB085N 8.5 85 95 79 69 3-1/2" 13-1/4" 6" 2-3/4" 37-2/3" 13-1/2" 8-1/3" 10-1/2" 15" 32-1/2" 8-1/3" 1/2" 1" 2" 2" 165 ,t2 KHB11ON 11 110 95 102 89 2-3/4" 14-3/4" 7-1/2" 2-3/4" 38" 14-1/3" 9-3/4" 10-1/2" 15" 33" 8-1/3" 1/2" 1" 3" 3" 170 Qf KHB155N 15.5 155 95 144 125 2-3/4" 14-3/4" 7-1/2" 2-1/2" 38" 14-1/3" 9-3/4" 10-1/2" 15" 33" 8-1/3" 1/2" 1" 3" 3" 175 Qf KHB199N 19.9 199.9 95 185 161 3" 15-1/2" 7-1/2" 2-1/2" 38-1/3" 14-1/3" 10-1/2" 11-1/2" 15" 33" 8-1/3" 1/2" 1-1/4" 3" 3" 195 Qf KHB285N 28.5 285 95 264 229 3" 15-1/2" 7-1/2' 2-1/2" 38-1/3" 14-1/3" 10-1/2" 11-1/2" 15" 33" 8-1/3" 1/2" 1-1/4" 3" 3" 205 •Information subject to change without notice.Change"N"to"L"for LP gas models. •The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. •Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system operation,extensive piping systems,etc.•The ratings have been determined under the provisions governing forced draft burners. RIGHT SIDE •� TOP High Voltage BOTTOM - t F H —'.-I Flue Vent Electrical Connection Low Voltage A F • Air Intake --- Electrical Connection Water _.�•a j AC Outlet • ��� Inlet 0 0 0 B 0 0• E I- - t� A iCO D i0, !°� ik J i�' I Condensate Drain 1 ► 1111111111111111 L Gas Inlet B • ' - N M� Water Outlet 11i N • Y Y WALL MOUNT Ama CERTIFIED° C Input Heating Net AHRI Shipping Model Max. Min. Capacity Rating A B C D E F G H I I K L M N Gas Water Air Vent Wt. Number MBH MBH AFUE% MBH MBH Conn. Conn. Inlet Size (lbs.) 425 WHB055N 55 8.3 95 51 44 40" 18-3/4" 16" 31-1/8" 8-1/2" 3-3/4" 4-1/2" 6-1/2" 7-1/4" 8-7/8" 3-1/2" 1-1/2" 1-1/2" 6" 1/2" 1" 2" 2" 139 Qf WHB085N 85 8.5 95 79 69 39-3/4" 18-3/4" 16" 31-1/8" 8-1/2" 3-3/4" 4-1/2" 6-1/2" 7-1/4" 8-7/8" 3-1/2" 1-1/2" 1-1/2" 6" 1/2" 1" 2" 2" 142 Of WHB11ON 110 11 95 102 89 41-1/4" 18-1/4" 19" 31-1/8" 10" 2-3/4" 5" 5-1/4" 11-1/2" 8-1/2" 5" 1" 1" 4-1/2" 1/2" 1" 3" 3" 159 B-1 I WHB155N 155 15.5 95 144 125 41-1/4" 18-3/4" 19-1/8" 31-1/8" 10" 2-3/4" 5" 5-1/4" 11-1/2" 8-1/2" 5" 1" 1" 4-1/2" 1/2" 1" 3" 3" 166 WHB199N 199.9 19.9 95 185 161 41-1/4" 18-3/4" 19-1/8" 31-1/8" 10-1/2" 3" 5-1/4" 6" 11" 9-1/2" 6-1/4" 1-1/2" 1-1/2" 4-1/2" 1/2" 1-1/4" 3" 3" 175 Qf WHB285N 285 28.5 95 264 229 41-3/4" 18-3/4" 21-1/8" 31-1/8" 15" 3" 3-3/4" 5-1/4" 12-1/4" 11" 6-1/4" 1-1/2" 1-1/2" 6-1/2" 1/2" 1-1/4" 3" 3" 184 (Q WHB399N 399 80 94.4* 377' 328 43-1/4" 25-1/4" 21-7/8" 34" 3-1/2" 4-1/4" 22-1/2" 3-7/8" 8-7/8" 12-1/2" 9-1/4" 2" 2" 21-1/2" 3/4" 1-1/2" 4" 4" 213 *Thermal Efficiency% •Information subject to change without notice.Change"N"to"L"for LP gas models. •The Net AHRI Water Ratings #Gross Output MBH shown are based on a piping and pickup allowance of 1.15.• Lochinvar should be consulted before selecting a boiler for **10:1 Turndown ratio and top and bottom water installations having unusual piping and pickup requirements,such as intermittent system operation,extensive piping connections are not included on WHB399. systems,etc.•The ratings have been determined under the provisions governing forced draft burners. WHB399 operates with a 5:1 turndown. E I\1E D Lochinvar,LLC III® L300eb Maddox Simpson Parkway VM Lebanon,Tennessee Park LOW XON*LocbinvarP:615.889.8900/F:615.547.1000 EM Men BER HIGH EFFICIENCY BOILERS&WATER HEATERSIFlfo ')`,/ 2021 �i ©®0 Lochinvar.com .,7 H 6/18—Prince otN BUILDING DEPARTMENT