File Documents.211 W Hopkins Ave.0078-2021-BRES (32)
REScheck Software Version 4.7.1 Compliance Certificate Project NOTE - The cabin is considered a Energy Code: 2015 IECC historical structure per the City of Location: Aspen, Colorado Aspen. The new basement along with Construction Type: Single-family Project Type: New Construction / Renovation new mechanical and lighting systems Orientation: Bldg. faces 90 deg. from North meet the IECC code requirements. Conditioned Floor Area: 1,489 ft2 However the 1st floor historical cabin Glazing Area 7 (�o(9922 HDD) Climate Zone: 7 envelope does not as retrofits to the Permit Date: envelope are not being allowed. Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 211 West Hopkins Street Matt Joblon IMEG Corp Aspen, CO 81611 Compliance: Average fenestration U-factor exceeds maximum Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter EAST WALL: Other Wall 261 0.400 97 Orientation: Front Window 1: Wood Frame:Single Pane 19 0.910 17 SHGC: 0.69 Orientation: Front SOUTH WALL: Other Wall 231 0.400 69 Orientation: Right side Window 2: Wood Frame:Single Pane 39 0.910 35 SHGC: 0.69 Orientation: Right side Window 3: Wood Frame:Single Pane 20 0.910 18 SHGC: 0.69 Orientation: Right side WEST WALL: Other Wall 261 0.400 94 Orientation: Back Window 4: Wood Frame:Single Pane 8 0.910 7 SHGC: 0.69 Orientation: Back Window 5: Wood Frame:Single Pane 19 0.910 17 SHGC: 0.69 Orientation: Back NORTH WALL: Other Wall 231 0.400 74 Orientation: Left side Window 6: Wood Frame:Single Pane 19 SHGC: 0.69 REt IVE DOrientation: Left side •e.. Project Title: Report dfj5 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 1 of 9 ASPEN BUILDING DEPARTMENT Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Window 7: Wood Frame:Single Pane 13 0.910 12 SHGC: 0.69 Orientation: Left side Window 8: Wood Frame:Single Pane 13 0.910 12 SHGC: 0.69 Orientation: Left side Floor 1: Other Floor: Over Unconditioned Space 780 0.028 22 Ceiling 1: Other Ceiling 780 0.470 367 Basement Wall 1: Other Basement Wall 280 0.050 10 Orientation: Front Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Basement Wall 2: Other Basement Wall 320 0.050 11 Orientation: Right side Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Basement Wall 3: Other Basement Wall 320 0.050 11 Orientation: Back Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Basement Wall 4: Other Basement Wall 280 0.050 10 Orientation: Left side Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Mechanical Equipment Description Fuel type Efficiency Air Source 10 HSPF, 19.5 SEER RECEIVED Project Title: Report dfs5/20J62621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 2 of 9 ASPEN BUILDING DEPARTMENT RInspectionEScheck Software VersionChecklist 4.7.1 Energy Code: 2015 IECC Requirements: 59.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, 'Construction drawings and '❑Complies 103.2 documentation demonstrate ❑Does Not See Historical [PR1]1 energy code compliance for the ,,: building envelope.Thermal ❑Not Observable NOTE on page 1 of envelope represented on ❑Not Applicable this report. construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, (documentation demonstrate ❑Does Not 403.7 lenergy code compliance for [PR3]1 lighting and mechanical systems. ['Not Observable g, Systems serving multiple ENot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is' Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: H, Manual J or other methods ['Not Observable Btu/hr Btu/hr 'approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report dfj5/ 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 3 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value. Where interior R- R- ❑Does Not table for values. insulation is used, verification may need to occur during [Not Observable Insulation Inspection. Not ENot Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not 6 manufacturer's instructions. [Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. t distance from top of wall. [Not Observable ❑Not Applicable 303.2.1 IA protective covering is installed ❑Complies [F011]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Requirement will be met. [F012] controls installed. ❑Does Not .44 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report d/55/ 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 4 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, ,average). ❑Does Not table for values. 402.3.3, 402.5 [Not Observable See Historical [FR2]1 ❑Not Applicable NOTE on page 1 of this report. 303.1.3 U-factors of fenestration products 'EComplies See Historical [FR4]1 are determined in accordance ❑Does Not 41) with the NFRC test procedure or [Not Observable NOTE on page 1 of taken from the default table. this report. ❑Not Applicable p 402.4.1.1 Air barrier and thermal barrier EComplies See Historical [FR23]1 installed per manufacturer's ❑Does Not 40 instructions. [Not Observable NOTE on page 1 of ❑Not Applicable this report. 402.4.3 Fenestration that is not site built EComplies See Historical [FR20]1 is listed and labeled as meeting EDoes Not Q AAMA/WDMA/CSA 101/I.S.2/A440 ['Not Observable NOTE on page 1 of or has infiltration rates per NFRC ill 400 that do not exceed code ❑Not Applicable this report. limits. 402.4.5 IC-rated recessed lighting fixtures EComplies [FR16 sealed at housing/interior finish Does Not and labeled to indicate . 2.0 cfm leakage at 75 Pa. [Not Observable ❑Not Applicable 405.2 All ducts in unconditioned spaces R- R- EComplies Exception: Ducts located [FR25]1 or outside the building envelope ❑Does Not completely inside the are insulated to >_R 6. ❑Not Observable building envelope. , ❑Not Applicable 403.3.5 ;Building cavities are not used as EComplies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not j [Not Observable , ❑Not Applicable 403.4 :HVAC piping conveying fluids R- R- EComplies Requirement will be met. [FR17]z 'above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R-— ['Not Observable CI Not Applicable 403.4.1 Protection of insulation on HVAC EComplies Requirement will be met. [FR24]1 piping. ❑Does Not ©J ❑Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers are EComplies [FR19]z installed on all outdoor air ElDoes Not intakes and exhausts. ['Not Observable , ❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report d/55/ 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 5 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled '❑Complies • [IN13]2 or the installed R-values ❑Does Not provided. Ilir [Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Woo-d ❑Does Not table for values. ['Nip ❑ Steel ❑ Steel [Not Observable tio ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the CO underside of the subfloor, or floor ['Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Woo-d ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable See Historical [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable NOTE on page 1 of this report. 303.2 Wall insulation is installed per ❑Complies See Historical [IN4]1 manufacturer's instructions. ❑Does Not NOTE on page 1 of [Not Observable ❑Not Applicable this report. Additional Comments/Assumptions: 1 1High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report d/55/ 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 6 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID_ 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood EDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel See Historical 402.2.6 ❑Not Observable [FI1]1 ❑Not Applicable NOTE on page 1 of this report. 303.1.1.1, Ceiling insulation installed per ❑Complies See Historical 303.2 manufacturer's instructions. EDoes Not [F12]1 Blown insulation marked every NOTE on page 1 of 300 ft2. [Not Observable this report. ❑Not Applicable p 402.2.3 ;Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ;extends over insulation. [Not Observable j ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies See Historical [F117]1 ach in Climate Zones 1-2, and EDoes Not I<=3 ach in Climate Zones 3-8. NOTE on page 1 of ENot Observable this report. ❑Not Applicable p 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air [F14]1 cfm/100 ft2 across the system or ft2 ft2 EDoes Not handlers are located within <=3 cfm/100 ft2 without air conditioned space. handler @ 25 Pa. For rough-in [Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies Exception:All ducts and air [FI27]1 determine air leakage with ft2 ft2 Does Not handlers are located within either: Rough-in test:Total ['Not Observable conditioned space. leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [F19]2 installed for control of primaryiiii ❑Does Not heating and cooling systems and initially set by manufacturer to [Not Observable code specifications. ❑Not Applicable 403.1.2 ;Heat pump thermostat installed Complies Requirement will be met. [F110]2 on heat pumps. EDoes Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Requirement will be met. [FI11]2 systemsaccessible havemanual automaticcontrols.or. EDoes Not ❑Not Observable ❑Not Applicable 403.6. All mechanical ventilation system qElComPlies Requirement will be met. [F125 fans not part of tested and listed EDoes Not HVAC equipment meet efficacy and air flow limits. ['Not Observable ENot Applicable 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIV D Project Title: Report d/55/20/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 7 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.2 ;Hot water boilers supplying heat •Complies Requirement will be met. [F126]2 through one-or two-pipe heating •Does Not systems have outdoor setback control to lower boiler water •Not Observable temperature based on outdoor ■Not Applicable :temperature. 403.5.1.1 Heated water circulation systems ❑Complies Requirement will be met. [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for 'circulating hot water system iippumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump :when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 'Electric heat trace systems ❑Complies Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 11 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the :piping. 403.5.2 Water distribution systems that ❑Complies Requirement will be met. [F130]2 have recirculation pumps that EDoes Not pump water from a heated water supply pipe back to the heated [Not Observable water source through a cold ENot Applicable water supply pipe have a demand recirculation water system. Pumps have controls ;that manage operation of the :Pump and limit the temperature of the water entering the cold ;water piping to 104°F. 403.5.4 'Drain water heat recovery units ❑Complies Exception: Requirement is [FI31]2 tested in accordance with CSA ❑Does Not not applicable. B55.1. Potable water-side pressure loss of drain water heat [Not Observable recovery units < 3 psi for ❑Not Applicable 'individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 '75%of lamps in permanent ❑Complies Requirement will be met. [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ;❑Complies Exception: Requirement is [F123]3 no continuous pilot light. ❑Does Not not applicable. d' ' [Not Observable + II ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [F17]2 ❑Does Not [Not Observable ❑Not Applicable 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report d/55/ 0/52621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 8 of 9 ASPEN BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.3 Manufacturer manuals for '❑Complies Requirement will be met. [File mechanical and water heating ElDoes Not ,systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED Project Title: Report d55/25/0152621 Data filename: \\files\Active\Projects\2021\21001159.00\Design\Mechanical\ResCheck Compliance.rck Page 9 of 9 ASPEN BUILDING DEPARTMENT