HomeMy WebLinkAboutFile Documents.930 W Smuggler St.0113-2023-BROF (8) CITY OF ASPEN S/t7c�tif 6�v.KeS UseU _ f Field Plan Set Must Be Printed In Color �I
PERMIT 0113-2023-BROF '_1�.I� `^/ ,/1 ;
T NO. m �b�`� ��v�.�L�N� ������G� ESR•2119IMostWdelyAccepfedandT Trusted Page4of10 \ ' 'I
r
NEWMAN FAMILY TRUST t a TABLE 1—FIRE CLASSIFICATIONS
OWNER Sri o w BR/Jt� S �R�� •
ADDRESS SYSTEM ROOF ROOF MIN. DaVINCI ROOF SHINGLE
.� NO. CLASS DECK SLOPE UNDERLAYMENT' Exposure CITY OF
930 W SMUGGLER ST 2 Roors g ( ' ASPEN
Shingle n
- _.—_..._ T— —) y 1 A Min hz 312 Oneof ASTM D2 6 Type)(No.II15 asphalt-saturatedlayers
DaV nc Slate 'fi
PARCEL ID .. . ... i inch Type y ;aap
273512221001 I • •••• •t.. rr I•�•• I plywood organcrele
Pe_•'••:, • • - - DaVlncl Slate 61o7%
✓ eel SIB•• I ohplln/rz One layer GAF VersaSheltlSR2053sWntRoof Thesemuus eKe tatthe
'
'. 2 A 3:12 DaVlnci Shake 9 to 10
i�, inch plywootl Deck Protection(ESR-2053)2 plansp
_ _ i;,,,� Davinci Select Shake 9 to 10
•
Davinci Slate 6to8 building site or inspection
APPI ICATION ACCEPTED DATE: 2023-10-30 PERMIT NUMBER: 0113-2023-BROF . I _ I One layer ASTM D226 Type II(No.30)asphalt- Davinci Shake 9to 10 delays mayoccur.Construction
,II Min.'Viz- y
• . 3 A inch plywootl 3.12 saturated organic felt plus one layer of ASTM D3909 Davinci Select Shake 9 to 10
•
I mineral-surfaced cap sheetz Bellaforte Shake 12 shall conform to these plans.All
Province Slate 8 changes shall be approved
Davinci slate 6 to a 9 pp by
COMMUNITY DEVELOPMENT DEPARTMENT ��� I 24..
t tF ( Davinci Shake 91010
t`,%�� •
\'� Mln.iB/2x- Two layers ASTM D226 Type II(No.30)asphalt- DaVlnci Select Shake 9 to 10 liiiiking official.
�' �� • I % I 4 B inch plywood 3'12 coated glass-fiber-mat' Bellaforte Shake 12
BUILDING PERMIT COVERSHEET •
•«� \ Bellaforte Slate 12
CITY OF ASPEN i �`' I Promo 8
1 _—' I Davinci Slate 6 to
• Davinci Shake 9to 10 SEPARATE PERMITS ARE
• Min.i%2- One layer Eco Chief Products SolaMlde""-SRW Da Vinci Select Shake 9 to 10
PROPERTY INFORMATION ^ • �•• • I�' 5 A 3a2 REQUIRED FOR ELECTRICAL,
!Cr I • { inch plywood (ES2-4035) Bellaforte Shake 12
M 1 • •v • BenafOrteslale 12 PLUMBING,MECHANICAL,OR
ADDRESS: 930 W SMUGGLER ST UNIT: Io •II _ i ' •I••Rr ••• •••i �rovin_lala 8 FIRE SPRINKLER WORK
PARCEL ID: 273512221001 LEGAL DESCRIPTION: TAGERT LOT SPLIT •—i
OWNER: NEWMAN FAMILY TRUST i • • I I �j___••••• •••�.�I 6 A Min.'/,e--inch 3:12 One layer Eco Chief Products SolarHide'^'-SRW Davinci slate 6108
PERMIT CONTRACTOR: . • • ti— �� OSB (ESR-4035)
• I SMOKE ALARMS AND
• • •• ! DavmciSlats sloe - CARBON MONOXIDE
• l_ ,j�� DaVindShake 9fo10 DETECTORS REQUIRED
•fir, j • Min.'lo'inch One layer Eco Chief Products SolarHideTM-SRW Davinci Select Shake 9 to 10
DESCRIPTION OF WORK New roof on the house. Ir•• \ .••Br: 7 B OSB 3:12 (ESR3035) BellaforteShake 12 THROUGHOUT DWELLING
Bellaforte Slate 12
1i, .%- UNIT PER CITY OF ASPEN
Province Slate 8
_ I DavinOislate st07 MUNICIPAL CODE 8.15
Min.1p/32- Two layers of MB Technology Layfast TU35
II 8 A inch plywood 3.12 (ESR-2799) Davinci Shake 9 to 10
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? •I. �\ \ —. �• Davinci Select Shake 9to 10
I Min.'/,e-inch Two layers of Polyglass XFR Davinci Stele 8l0 8
`- 9 A 3:12 Davinci Shake 9 to 10
OSB (ESR-1897) ()Wind Select Shake 9 to 10 I
CLASS OF WORK Residential FIRE SPRINKLER TYPE It should be known that this review shall
I For SI:1 inch=25.4 mm;1ft=0.305m
I•••.I • • • • • •• • - 'ASTM D226 Type I(No.15),ASTM D226 Type II(No.30)uncle underlayment
t and ASTM D3909 cap sheet must be installed in accordance with the applicable not relieve the applicant of their
•
_ • • •• • • •►••• building code.GAF Versashield°Fire-Resistant Roof Deck Protection u must be installed in accordance with ESR-2053.Eco Chief Products reS onsibilit to comply with the
( ) INSPECTIONS
REQUIRED SPECIAL ,LS. i. • • • • • SolarHiueTM-SRW undeda t must be installed in accordance with ESR-4035.La t TU35 must be installed in accordance with ESR-2799.Pol t k p Y p Y
BUILDING TYPE IRC •• I ymen yfas ys is
INSPECTIONS 1•• i•P, 13' I XFR must be installed in accordance u with ays-t,s7. requirements of the City of Aspen
zone layer of self-adhered roofing underlayment,specified in an ICC-ES evaluation report as complying with AC48 and AC188,may be installed directly
�. • • ••so. over the plywood and beneath the ASTM D226 complying underlayment In System Nos.1,3 and 4 or over the plywood and beneath the GAF VersaShleld® Municipal Code.Pursuant to
CONSTRUCTION TYPE ENERGY CODE COMPLIANCE r I -•, • ���• Fire-Resistance Roof Deck Protection(ESR-2053)in System No.2. Sec.26.104.050,any permit or approval
• i!' ••• issued in error or otherwise not in
•WORK ORANGES BUILDING ' • •' • ,• conformity with the requirements of this
OCCUPANCY GROUPIIBC) FOOTPRINT? • r• w•B,' Title,shall be void.Similarly,any permit
i���IS • ' or approval issued in reliance upon or
woEEomoNs TorusvASQ.Fr. ...�., as a result of,a materially false
. statement or representation made in
- 9- the process of obtaining the permit or
\
OTHER CODE EDITIONS TOTAL SNOYYMELT 54FT. 10 \ \j // `'�, b development approval shall,likewise,
e void.Any peron having received a
\\\ void or voidable permit or approval
HISTORIC PROPERTY? NO TOTAL POOLSQ.FT. f� shall not be relieved from having to
•
j' �;,� RECEIVED comply with all applicable terms and
I conditions of this Title and the City shall
jla� 10/30/2023 not be estopped from fully enforcing
FIRE SPRINKLER EXISTING? I"•= ..•
• Illlu/psR•• EOiPd ALE.w
•:•:.: /••• K1/aa same.
m �•5`• :a2' 12• \ 6• ASPEN
BUILDING DEPARTMENT
z J op,SFrc' 830 Sr1VCGLEP. Sy.4gP=,v
;L
4- Snow stops require a a oca ions
.o where roofs could shed snow onto �Vj1
CITY OF ASPEN12022 427 RIO GRANDE PL ASPEN,CO walkways,stairs,alleys,decks,exits, " "
utilities and meters,emergency escape n) Q�F ri--A 10/31/2023 (�J
and rescue opening window wells,or I V G W 1
P adjacent properties-Ordinance 1,
U 2023.
linzhid
EdiYN IUstomisv_ S30Si1mo6Qt�fL Soc./(Si3 ji• 3 3 LI
�(\ /�
SUB-ELECTRICAL PERMIT REQUIRED FOR HEAT `)/ V I/t1Ct Sikkito S /DesigaTaRi4c...s LCC
EX iSPltd 6 1Ge#1'mip8 S • r TAPE
EL A sub-electrical permit is required if a heat tape system is present,no matter the
total wattage.A licensed electrician must apply for the permit.
The sub-electrical permit must be applied for prior to the final roof inspection as
both final inspections will occur simultaneously. �,/ (�2 /
SDL.44 pdtttQ YVt�l 6C�ION I(QA![ 4CFa •. G4F
HEAT TAPE MANDATORY CONTROL REQ'S.
All heat tape systems shall meet the following per(Ordinance l Series 2023): ^yoo WzI1�I I,. �/����.[''.T.��u /� �•�C�
•
W./AT .Cl > .01. -Automatic controls configured for system shut off when air temperature is above •l "t' •t(P F'VSIUWlCTORGra; KARLES C,(r
PP�Nt I" y .0 40'F and comply with one of the following:
(, shut off in absence of moisture "1.
Iiiahul off at night(daylight sensor or timer) c^
r _i Amenity Energy Use Approved(2021 CODE) U-S`yt r� /'OG�M%((IUF4CTORai : C 01 6
• `"' -i • ti ® RREMP ElCREMP
NEtF�vef r
PERMIT#:0113-2023-BROF DATE:_10/31/23
..*: . '' •
:,,,,.. HEAT TAPE TOTAL WATTAGE: 1800
WATTS/FT: 6
..T7 s. TOTAL LINEAR FT: 300
I .c1 •,. OFFSET: REMP PAYMENT
or 1
t f Al
...
Note:
^' ; --78 Ala z -The first 1000W are exempt from REMP.
-All roof permits will require a sub-electrical
L ' I permit applied for by a licensed electrician.
zL Ll lL
Eu •El 5 -A sub-electrical permit must be applied for
1 prior to the final roof inspection as both final
E inspections will occur simultaneously.
s
RECEIVEDRECEIVED