File Documents.610 S West End St.0138-2021-BRES (11)
PennitDetail Save Cancel Field Plan Set Must Be Printed In Color ;�`►► READ THIS OR FAIL YOUR INSPECTION! Number 0138-2021-BRES Record Type Building[Change] ' Address 610 S WEST END ST K204 Owner ©Emmy Garrigus[Change; Furred&Dropped Ceilings,Soffits,and Walls %rp 2 IleA2 Original Number 21-2970 Status Permit Review 20015 IBC 803.13 This applies to the attachment of finishes or furring to any Type Building Reason for Cancel or Corrupt assemblies that are required to be either fire-rated or Review Fail non-combustible and is separate from the fire-rated CITY OF Applicant WHITNEY NORTON Aspen Internal? No assembly requirement. ASPEN Account ANNE GRICE INTERIORS Required Bond Amount g CITY OF ASPEN Project Total Available Bond Amount Walls,Ceiling s&Soffits:If furred 1%inches or less,do one of the following: These plans'rtept at the Land Use Planning Application Bluebeam Project Id 833-292-494 4.Fill spaces with Class A material. PERMIT NO.0138-2021-BRES building site or inspection Permit Contractor JANCKILA CONSTRUCTION INC HPC-ZON-EH-UTIL Review 5.Fill spaces with inorganic or non-combustible material. delays may occur.Construction 6.Fire block 8 feet in all directions. shall conform to these plans.All Valid Business License on HPC-ZON-EH-UTIL Review-2 OWNER D2 Propoperties of Florida changes shall be approved by Account Walls:If set out(furred)greater than 1 Y.inches, the building official. Imported Eng Review Eng-CMP Rev.Util Rev. do one of the following: ADDRESS.610 S West end st,K204 Required Submissions Parks-Prkng-San Review San Rev. 4.Use a Class A finish material(such as drywall). Documents Resubmitted Conditional Inspections 5.Use non-combustible framing. PARCEL ID 273718267052 SEPARATE PERMITS ARE 6.Protect both sides with fire sprinklers. REQUIRED FOR ELECTRICAL, Approved Covid-19 Plan ,/ Conditional Final Insp Eng-Wtr Final.Util Final.San Final PLUMBING,MECHANICAL,OR Ceilings&Soffits:If dropped(furred)greater FIRE SPRINKLER WORK ►Action Items than 1' inches: Framing members,hangers,and other assembly RESIDENTIAL REFERENCES FROM 2009 IBC SMOKE ALARMS AND members must be non-combustible.You may not CV/cs=crawl space ventilation sec.1203.3. 18"x CARBON MONOXIDE ►Queue Score use wood. 24"access required 1209.1 DETECTORS REQUIRED EE=emergency escape required sec 1029 THROUGHOUT DWELLING In Type III and V construction only,you may use fire EU=enclosed usable space under stairs shall be 1-hr UNIT PER CITY OF ASPEN ret w ' le framing. construction or stair enclosure rating.No access from stair MUNICIPAL CODE 8.15 v Dates _ enclosure.1009.6.3 ` New Application Date 10/27/2021 TCO Issuance Date # I I11 RV=roof and rafter ventilation required 1203.2 �, A=Attic Access 20"x 30"1209.2 — Application Complete Date 11/9/2021 Close/CO Issuance Date , 1 PUT um�,.E,m. SA=smoke alarm(NFPA 72)required sec 907.2.11.2 If should be known that this review shall Polilloco=carbon monoxide detector req.per Aspen Muni. not relieve the applicant of their Application Accepted Date 11/9/2021 Expiration Date �v�'�� Code 8.15 responsibility to comply with the E,o°"°,'."'" SG=safety glazing required sec 2406 requirements of the Cityof Aspen Issue Date Override Expiration Date o� „ V=ventilation required sec 1203.4.2.1,IMC 402&403 q p Municipal Code.Pursuant to Last Activity Date bathroom mechanical ventilation req.per City Sec.26.104.050,any permit or approval Ordinance 31 series 2011 issued in error or otherwise not in GR=guards,42"min ht,4"max opening sec 1013 conformity t with the requirements of this v Basic Information Dwelling Separation Required-2015 IBC HR=handrails 34"-38"ht sec 1012 Y q -708 Fire Partitions,711 Horizontal Assemblies: DS=Draft stopping/fire blocking 717 Title,shall be void.Similarly,any permit Description Full interior remodel.Including all new FF&E.an additional Census Code 434-Additions.Alterations.and Conversions tc Walls and floor/ceilings separating dwelling units shall have a fire-resistance RD=Roof drainage 1503.4 or approval issued in reliance upon or to for a of filler removal and relocation of some walls. Residential Buildings rating of at least 1 hour.Walls shall extend from the top of the floor assembly RV=Roof Ventilation 1203.2 as a result of,a materially false p p g below to the underside of the floor or roof slab or deck above or to the STC=Sound transmission class not less than 50 at statement or representation made in new larger sliding glass doors and window.new dropped dwelling separations,sec 1207 theprocess of obtainingthe permit or fire-resistance-rated floor/ceiling assembly above. ceiling in living area. SI=Stairway Illumination 1205.4 development approval shall,likewise, -714:Penetrations must be protected by a through-penetration firestopp pp PD=protect against decay,sec 2304.11 be void.Anyhaving Addition of storage space on deck system.Recessed fixtures shall not reduce the required fire resistance by use REFERENCES FROM 2009 IMC person received a of a listed fixture,a listed firehood,or a drywall assembly meeting the required DE=clothes dryer exhaust,sec 504.Makeup air req'd if void or voidable permit or approval Use of Building Multi-Family Interior Remodel Only 1 fire resistance.Exhaust fans require ceiling radiation damper. over 200 CFM shall not be relieved from having to -1207 Sound Transmission:Separating walls and floor/ceilings shall have an AS=access and service space for maintenance req'd, comply with all applicable terms and Use Class Residential STC rating of at least 50.Floor/ceilings shall have an IIC rating of at least 50. sec 306 conditions of this Title and the City shall Class of Work Alteration MA=make up air required if hood exhausts greater than not be estopped from fully enforcing 400 CFM,sec 505.2 same. Permit Comments Zoning comments no changes to exterior mechanical equipment or lighting in scope of work. Any recessed light fixtures in contact with insulation must be ET=exhausts terminate 3'from prop line and openings, — — IC rated. 10'from intakes,501.2.1 IT=intake openings 10'from lot line&contaminant rilp:rifi-0) d�av JOb LOCatIOn sources(nentd,streets), ctwoD=fasten and seal all ductwork per 603.9L':zAddress 610 S WEST END ST K204.ASPEN:273718267052 Lot REFERENCES FROM 2009 IFGCDV=direct vent req'd,sec 303.3 28/2022 Site Address Display on Map Legal Description Subdivision:GANT Unit:K-204 Existing Fireplaces and Woodstoves: CA=combustion air not taken from bedrooms,bathrooms ZO N I N G -If you propose to alter the firebox of a fireplace,it shall be Or Historic Property? No Eden Address removed or converted to gas logs. storage sec 303.3 Historic District? No Primary Owner -If you propose to move or alter a woodstove,it shall be OD=outdoor appliances must be listed for outdoor use, removed or replaced with a department certified woodstove. sec 303.6 REFERENCES FROM 2009 IECC ►HPC-Planning-Zoning Details F=new or replacement glazing shall not exceed 0.35 'kpp��j 1 E„yore ....) U-Value,NFRC label required,sec 402.3.E D w( General Electrical Requirements L=50%of lamps in permanently installed lights must be I high efficacy,sec 404.1 V Building Project Details Any areas affected by the renovation must be brought SE=All exterior joints,cracks,holes to be caulked, Valuation 5500 000 00 Lot Size Sq.Ft. 6.666 up to the current electrical code including: gasketed,sealed,sec 402.4 03 21 2 0 2 2 tamperproof receptacles(NEC 406.12), REFERENCES FROM 2011 NEC EP=electric panel'happy space'30"x36"x78",not in ground-fault circuit interrupter protection(NEC 210.8), storage,sec 110.26 �'� Reason for Valuation Change Soil Disturbance Sq Ft 0 Unit Sq.Ft. 1.055 Affected Area Sq Ft 0 arc-fault protection(NEC 210.12), j imp Building Footprint Sq Ft 0 Existing Hardscape Footprint Sq 0 receptacle spacing(NEC 210.52)etc. Ft Sq Ft of Building Work Area 1 055 Existing Hardscape%of Lot 0% Building Fire Area Sq Ft Con Mit Sq Ft Total 1.055 75%of lamps in permanently installed light fixtures shall be Utility Review Sq.Ft. 189 Utility Review Sq Ft Total 0 high efficacy-IECC R404.1 %of Interior being Altered 29% New Sq.Ft. 0 ► Scope of Work Details v Building Description Code Editions 2015 IBC Required Special Inspections Other Code Editions Energy Code Compliance Building Type(IRC) De/eted d) Total Snowmelt Sq Ft Construction Type VA Total Spa Sq Ft Occupancy Group R-2 Total Pool Sq Ft Occupancy Load Amount of Onsite Renewable Generation? Fire Sprinkler Existing? No CO Description Fire Sprinkler Required? No Basement Fire Sprinkler Type 1st Floor Fire Alarms Installed? NFPA 72 2nd Floor #Wood Fireplaces 3rd Floor *Gas Log Fireplaces Additional #Gas Appliances Open Text Field For Comments #of Onsite Parking Spaces • Calvetti Engineering, Inc. „o aT LEGEND I/^1-�A[[ 3a, 66 EXISTING WALLS TO BE DEMOLISHED �Jj\� zk Andrew L Calvetti, P.E. B3 '( '( SHELVES 1 P.O. Box 4231 OWNER'S F�„=E I j EXISTING WALLS TO REMAIN om CLOSET /'_1nH000 -•' L 4JQ 'alp ��//������������ PROPOSED-NEW WALLS y Aspen, Co 81611 — o 9ENDH I 1 -r—.� �1 F __ NOTE:DIMENSION FROM DRYWALL TO DRYWALL O u }� W O �44 ' , KITCHEN DINT ("P AREA Ph (970)925-8969 TRY 4 BIE F i i _ ' �„;G o„L.TH =N g P a o<o Email:alcengrg@aol.com rORET it j W„! ! "o�� _ ° -��; ,I-� I WENDOW 'U V U a CV i_ W Q W r r 111 9/27/21 �( _ �° SEAMS NALTMBER T' asa a� o REMOVE SLIDING L— 0X12 NOM I i,if/g G4,4.DOOR IicGs-� T �—i ..�i-mJ I{ DECKa E I�rOEi p i CLOSET IBATH#1� LIVING ROOM 1 11 _ U u a City of Aspen Colorado Bldg Dept BEDROOM#2 u " ' IBATH#211(3 �1 TI �11� Q�mmg 5W" ° 201 Mill St. 1.4 a Imo/' � I- BEDROOM#1 I W; V Ng S4iop= I x rcgyF� Aspen,Colorado 81611 �— ! ,�g �� pi Y �omamV o 3�y� Ph (970)920-5080/Fax(970)920.5044 i► � —`? !�� _ 10#• Z ZOD�� a6em n W Q6QTQ EO Attn: Building Official, Plans Examiner ;._7_• __.,. HFA„k ,1f),B6� —I ------ - -_� NICHE RELOCATE AC UNIT 9] x4�'0 I�LOcaT�Ac a"iT REMOVE EATER ATE TO REMAIN Re: Desino Residence/Gant Unit#K-204/610 S West End St/Aspen WALL GLASS RREMOVE SLIDING DECKPARTIALLY REMOVE - WITH SWITCH BELOW HEATER Colorado 81611/Proposed Remodel NEW HEAERINFLOOR I— r DESINO 0 r EXISTING&DEMO FLOOR PLAN G CO Building Official: SCALE: ,,,..=1•-D•• Z N oo This letter is being written at the request of Anne Grice Interiors for the 0 W purpose of obtaining a remodel permit for the above referenced project.There is one `Z cn Z O minor anticipated structural revision: COMMON WALL TO STONES ABWALLABDVE W W n Z HAVE'HR FIRE ROCK COUNTER Cl QUITE ROCK GYPSUM W UTILIZE b Z a Provide (3) ply 7 1/4 in.cont.wood beam header for four(4)door openings providing VENTILATBOARD.SEE DETAIL ION 63D0.1�.,�• aet \ _25°�FR"""G-L°MBUSTIBLE o Q OWNER'S RANGE& Y' ` x TO REMAIN EXISTING Sox [^ Q access to Bedroom 1&Bath 1.See attached plans.The anticipated required header NEW LLSIDELIGHT W° CLOSET Y L.= B1DUEFEE is m ALL WALLS TO HAVE F---T-- �\ 1 shall be verified upon demolition of the delineated wood frame wall located between TYPE X1HRFIRE NO EXISTING FIRE��-� NEW TAP LEFOR "r SPRINKLERS IN THIS - �f' R LOWER HEAT PIPE IN Entry, Kitchen and renovated closets, pantry,and Bath 1 as delineated to be removed BOARD, ii OTED ATQUIEr °"'T ,4 DINING AREA WINDOW RUNDERDEW ROCKON SEE DETAILS ENTRY l� N HEHAINGBONE HAnARN on the existing floor plan.Should you have any further questions, please call or write. REF 44 • KITCHEN `i--- \\\\\\\\\ \-- --- - E E /I k 1'I II NEW WINDOW TO FLOOR, ,.v¢!'Q ADO j��4► ADD3PER Tp STRUCTURAL ENGINEER, ?7 S p O'SETT TOR 1 LIVING ROOM • FOR DEFAILs SEE ELEVATION DRAWN WC ANNE GRICE INTERIORS Sincerely, r y CLN ►► BEAM CONTINUOUS W/zz,3X5 DECK Y fO �1• /• CAS I LSL JAC.STUDS fl�M MOM I�+ q clEIBM n V:A�4.� L Ci IYS it xDSWINGDOORSOCNCH c"sµD ; � � E IsrlNGexlzN INu �_ roF ooR"EeELEVATION DOORS PERMIT SET an"1X', OC �`:�'// PND6WINGDOOR60CUR � RELOCATED a O BATH RI ACUNIT. 4 / Z ACROSS GUEST CLOSET, OOM#2 / �` 36Q / WNERSLLOSEi PAN CARPET /LE EXILOSTINN EBEDROOM#1 TIMBER BEAMS. 09-24-2021 111 l�^/1 ; 28 -4: BATH 1 SLIDING DOOR.T Y BATH#2 (E ELECTRIC ?/ID5.1 FOR DETAILS An eW L Calvetti, P.E.CO 36028 • PER JAMBSTUDS — " w NS 'RP'IX 'ELECTRIC — ooR = ISSUE DATE: /.►Is �: � OPENINGS SWIEOF •ELOCA,AC NED INEFLOOAF fIA Lt Irk RELOCATED `\"""`1 04/29/2021 CLIENT REVIEW SET 1► 3,.-- -„• DOORS. FOR SWING - EXISTING I a - DO(/ 1 04/12/2021 CLIENT REVIEW SET �j EXISTING��ONAL�" ,- DOORS CONDENSER I �_ 1 8 0�... Cf4, 03/30/2021 REVIEW SET CC:Whitney Norton h\\\..\.s- REMAINS WHEATER N REMAINS CONDENSER a�' :GO', Lc4,,��Ixx 09/15/2021 PERMIT SET _ 0 . P / FLOOR SLIDER - 36028 -� ` A Anne Grice Interiors, LLC , _ `�} - = - Aspen,Colorado 81611 �R 1,101~\ e / CURELESS GAINLESS DECK t ORNGE HEATERS TO REMAIN ' 11 WILINEAR WLINEAR WITH NEW COVERS ,///,/ 'b�--- Ph (970)429 4148/Fax(970)429 4149 D " DRAINEW N GEANTRE UIREMEN SEE°ETAILM3os' �'NEW WALL `Ex EW DOORS S REQUIREMENTS, `\ I HUNG SHOWER,STEAM SEE WID5.6 FOR DETAILS �'A��� Email:whitney@annegrice.com TOILETS GENERATOR SHEET TITLE: DESINO EXISTING AND • PROPOSED FLOOR PLAN GRAPHIC SCALE,1011=1, PROPOSED SCALE: v4"=1.0" FLOOR PLANS PLAN RECEIVED NORTH z , o B SHEET: 0 I D 1 .1 11/09/2021 O2i28i2O22� LERIRCUU W UMICE RECEIVED FAME °',,aZ,°,z�D FEW ASPEN WNW 11/09/2021 BUILDING DEPARTMENT ASPEN BUILDING DEPARTMENT