Loading...
HomeMy WebLinkAboutFile Documents.428 E Hyman Ave.0056-2023-BCOM (10) APPLICATION ACCEPTED DATE: 2023-10-26 PERMIT NUMBER: 0056-2023-BCOM Field Plan Set Must Be Printed In Color , 0 D COMMUNITY DEVELOPMENT DEPARTMENT \/;' � 2021 IBC 601 Fire Resistive Requirements for READ THIS OR FAIL YOUR INSPECTION! BUILDING PERMIT COVERSHEET CITY OF Type of Construction: VA CITY OFASPEN ASPEN Primary Structural Frame: 1 hr Dropped Ceilings and Soffits beneath fire rated (columns,beams,girders,etc) assemblies PROPERTY INFORMATION Exterior Bearing Walls: 1 hr 2021 IBC 803.13 ADDRESS: 428 E HYMAN AVE C UNIT: Interior Bearing Walls: 1 hr This applies to the attachment of finishes or furring to any PARCEL ID: 273707339030 LEGAL DESCRIPTION: KOBEY BUILDING CONDO Floors/Ceilings: 1 hr assemblies that are required to be either fire-rated or These plans muus eKeept at the OWNER: SILVER SLAM COMMERCIAL LLC ROOF: 1 hr non-combustible and is separate from the fire-rated PERMIT CONTRACTOR: Sachse Construction and Development assembly requirement building site or inspection Company LLC Unless noted otherwise for occupancy separation or firedelays may occur.Construction separation distance. shall conform to these plans.All 1.Dropped Ceilings&Soffits:If dropped 1 a/. DESCRIPTION OF WORK Removal of two short interior fitting room partitions,adding one 6.-0"long partition,closing existing openings inches or less,do one of the following: changes shall be approved by for fitting room reconfiguration.Removal of two drinking fountains.New Millwork paneling,millwork fixtures, -Fill spaces with Class A material. Ifiliging official. refinishing of floor,new paint.Existing ceiling,floor,lighting,mechanical system,sprinkler and Fire alarm and -Fill spaces with inorganic or non-combustible material. fire protection to remain undisturbed.Existing facade,storefront,exit doors to remain.No storefront work. -Fire block 8 feet in all directions. Existing handicapped access and restrooms,to remain undisturbed. 2.Dropped Ceilings&Soffits:If dropped greater SEPARATE PERMITS ARE than 1%inches: REQUIRED FOR ELECTRICAL, Framing members,hangers,and other assembly PLUMBING,MECHANICAL,OR USE OF BUILDING Mixed-Use FIRE SPRINKLER REQUIRED? Yes members must be non-combustible.You may not FIRE SPRINKLER WORK use wood. CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13 In Type III and V construction only,you may use fire SMOKE ALARMS AND retardant treated wood or non-combustible framing. CARBON MONOXIDE DETECTORS REQUIRED REQUIRED SPECIAL BUILDING TYPE(IRO Other THROUGHOUT DWELLING INSPECTIONS r UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE COMCheck UA Alternative OCCUPANCY GROUP(IBC) M FOOTPRINT?WORK CHANGES BUILDING No pP 9 3.Dropped Ceilings&Soffits below Heavy Timber T&G ceilings,do all of the following: I-One layer 5/8"type X gypsum board directly It should be known that this review shall CODE EDITIONS 2021 IEBC TOTAL SPASQ.FT. attached with minimum level one finish. not relieve the applicant of their -Drop ceiling according to item 1 or 2 above as responsibility to comply with the OTHER CODE EDITIONS zozllec TOTAL SNowMELr sq.Fr. applicable. requirements of the City of Aspen (City Policy) Municipal Code.Pursuant to Sec.26.104.050,any permit or approval HISTORIC PROPERTY? Yes TOTAL POOL SOFT. issued in error or otherwise not in conformity with the requirements of this Title,shall be void.Similarly,any permit FIRE SPRINKLER EXISTING? Yes or approval issued in reliance upon or as a result of,a materially false statement or representation made in the process of obtaining the permit or development approval shall,likewise, be void.Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. , ATMOSPHERE 10.06.23 To the Aspen DOB, As the Architect for the Bottega Veneta Temporary Store(drawings)located at 428 Hyman Avenue,Aspen,CO,I am certifying that there is no structural impact to removing the fitting room walls shown on our demolition plan. Regards, Louis Loria,AIA CO license R ARC-400890 06 COt09 dorw ''PO ARO�x rale 11/02/2023 j1 Ft1R000t,GUMPI IANCE ;ustiTTh ,asCOLUMBUS AVENUE.SUITE 3ps,VALHALLA,NEW Teen 1059s T914nur.aaua WWW.ATMCREC EIVED 46s COLUMBUS AVENUE.SUITE 305,VALHALLA,NEW Teen 10595 T914/df!EV9T`CyTIVAMo511189ye 2023 ARCHITECTURE • INTERIORS ASPEN BUILDING DEPARTMENT