HomeMy WebLinkAboutFile Documents.428 E Hyman Ave.0056-2023-BCOM (10) APPLICATION ACCEPTED DATE: 2023-10-26 PERMIT NUMBER: 0056-2023-BCOM Field Plan Set Must Be Printed In Color , 0 D
COMMUNITY DEVELOPMENT DEPARTMENT \/;' � 2021 IBC 601 Fire Resistive Requirements for READ THIS OR FAIL YOUR INSPECTION!
BUILDING PERMIT COVERSHEET
CITY OF
Type of Construction: VA
CITY OFASPEN ASPEN
Primary Structural Frame: 1 hr Dropped Ceilings and Soffits beneath fire rated
(columns,beams,girders,etc) assemblies
PROPERTY INFORMATION
Exterior Bearing Walls: 1 hr 2021 IBC 803.13
ADDRESS: 428 E HYMAN AVE C UNIT: Interior Bearing Walls: 1 hr This applies to the attachment of finishes or furring to any
PARCEL ID: 273707339030 LEGAL DESCRIPTION: KOBEY BUILDING CONDO Floors/Ceilings: 1 hr assemblies that are required to be either fire-rated or These plans muus eKeept at the
OWNER: SILVER SLAM COMMERCIAL LLC ROOF: 1 hr non-combustible and is separate from the fire-rated
PERMIT CONTRACTOR: Sachse Construction and Development assembly requirement building site or inspection
Company LLC Unless noted otherwise for occupancy separation or firedelays may occur.Construction
separation distance. shall conform to these plans.All
1.Dropped Ceilings&Soffits:If dropped 1 a/.
DESCRIPTION OF WORK Removal of two short interior fitting room partitions,adding one 6.-0"long partition,closing existing openings inches or less,do one of the following: changes shall be approved by
for fitting room reconfiguration.Removal of two drinking fountains.New Millwork paneling,millwork fixtures, -Fill spaces with Class A material. Ifiliging official.
refinishing of floor,new paint.Existing ceiling,floor,lighting,mechanical system,sprinkler and Fire alarm and -Fill spaces with inorganic or non-combustible material.
fire protection to remain undisturbed.Existing facade,storefront,exit doors to remain.No storefront work. -Fire block 8 feet in all directions.
Existing handicapped access and restrooms,to remain undisturbed.
2.Dropped Ceilings&Soffits:If dropped greater SEPARATE PERMITS ARE
than 1%inches: REQUIRED FOR ELECTRICAL,
Framing members,hangers,and other assembly PLUMBING,MECHANICAL,OR
USE OF BUILDING Mixed-Use FIRE SPRINKLER REQUIRED? Yes members must be non-combustible.You may not FIRE SPRINKLER WORK
use wood.
CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13 In Type III and V construction only,you may use fire SMOKE ALARMS AND
retardant treated wood or non-combustible framing. CARBON MONOXIDE
DETECTORS REQUIRED
REQUIRED SPECIAL
BUILDING TYPE(IRO Other THROUGHOUT DWELLING
INSPECTIONS r UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE COMCheck UA Alternative
OCCUPANCY GROUP(IBC) M
FOOTPRINT?WORK CHANGES BUILDING No pP 9 3.Dropped Ceilings&Soffits below Heavy
Timber T&G ceilings,do all of the following: I-One layer 5/8"type X gypsum board directly It should be known that this review shall
CODE EDITIONS 2021 IEBC TOTAL SPASQ.FT. attached with minimum level one finish. not relieve the applicant of their
-Drop ceiling according to item 1 or 2 above as responsibility to comply with the
OTHER CODE EDITIONS zozllec TOTAL SNowMELr sq.Fr. applicable. requirements of the City of Aspen
(City Policy) Municipal Code.Pursuant to
Sec.26.104.050,any permit or approval
HISTORIC PROPERTY? Yes TOTAL POOL SOFT. issued in error or otherwise not in
conformity with the requirements of this
Title,shall be void.Similarly,any permit
FIRE SPRINKLER EXISTING? Yes or approval issued in reliance upon or
as a result of,a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall,likewise,
be void.Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
, ATMOSPHERE
10.06.23
To the Aspen DOB,
As the Architect for the Bottega Veneta Temporary Store(drawings)located at 428 Hyman Avenue,Aspen,CO,I
am certifying that there is no structural impact to removing the fitting room walls shown on our demolition plan.
Regards,
Louis Loria,AIA
CO license R ARC-400890
06 COt09
dorw
''PO ARO�x
rale
11/02/2023 j1
Ft1R000t,GUMPI IANCE
;ustiTTh
,asCOLUMBUS AVENUE.SUITE 3ps,VALHALLA,NEW Teen 1059s T914nur.aaua WWW.ATMCREC EIVED
46s COLUMBUS AVENUE.SUITE 305,VALHALLA,NEW Teen 10595 T914/df!EV9T`CyTIVAMo511189ye 2023
ARCHITECTURE • INTERIORS
ASPEN
BUILDING DEPARTMENT