Loading...
HomeMy WebLinkAboutFile Documents.22 W Water Pl.0032-2023-BROF (9) CITY OF ASPEN Field Plan Set Must Be Printed In Color 1►�►I PERMIT NO.0032-2023-BROF 404 0° OWNER OTT SARA G 8 MATTHEW M • •T 13M EVALUATION �' 'ICC ,I SERVICE' r ADDRESS 22 W WATER PL ; ilif a CITY OF 273513204019 rtx� i. eanpor,ce wnn mormetwmst code. PARCEL ID r ` _ Existing gutter ASPEN replaced like for like. • compasses with Sole codes 4 "Ip APPLICATION ACCEPTED DATE: 2023-04-26 PERMIT NUMBER: 0032-2023-BROF s - 4.Drains to —laandscaping These plans muu e>s ept at the • / www.icc es.orq j (800)423-6587 (562)699-0543 A Subsidiary of the International Code Council° building site or inspection •- A, I'. Hardscape delays may occur.Construction COMMUNITY DEVELOPMENT DEPARTMENT �0 � �, • Walkway ICC ES Evaluation Report Reissued January2O23 shall conformjiiiiii to these plans.All I �► r _� changes shall be approved by �` /�� Y ES R-1389 This report is subject to renewal January 2024. �1ta�� All areas not called ing official. BUILDING PERMIT COVERSHEET YT - I� f out as hardscape CITY OF ASPEN { • are landscaping DIVISION:07 00 00—THERMAL AND MOISTURE vnth asphalt on both sides.and surfaced with mineral roofing - •• 22 • •- `•1 • PROTECTION granules on the weather side and a mineral release agent Section:07 31 13—Asphalt Shingles on the back side SEPARATE PERMITS ARE PROPERTY INFORMATION p , _ y - -; 3.3 Laminated Shingles: REQUIRED FOR ELECTRICAL, "1/4 •, REPORT HOLDER: PLUMBING,MECHANICAL,OR ADDRESS: 22 W WATER PL UNIT: y • ` - Laminated shingles.including two-layer laminated,three- FIRE SPRINKLER WORK CERTAINTEED LLC layer laminated and tri-laminate laminated shingles, are PARCEL ID: 273513204019 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE - • /` Y 9 HOUSING 1 )''. composed of multiple thicknesses of coated and surfaced SMOKE ALARMS AND • • 4 ' EVALUATION SUBJECT: fiberglass mat,cut and bonded together n different patterns. OWNER: OTT SARAGB:MATTHEW M I . CARBON MONOXIDE 4lr` - The weather side is surfaced with mineral roofing granules. PERMIT CONTRACTOR: CITY OF ASPEN-ASSET MANAGEMENT g •• ` j • CERTAINTEEO ASPHALT SHINGLESDETECTORS REQUIRED Extent of proposed _ • ' and the back side is surfaced with a mineral release agent. work ( l THROUGHOUT DWELLING ., • e ' _ 1.0 EVALUATION SCOPE 3.4 Accessory Shingles: UNIT PER CITY OF ASPEN 1 li J ori - "1 Compliance with the following codes: 3.4.1 Hip and Ridge Shingles:Hip and ridge shingles are MUNICIPAL CODE 8.15 DESCRIPTION OF WORK The existing asphalt shingle roof of 22 W Water Place has reached the end of it's usable life.The existing roof is • ,`• —' • 1 . / r ■2021,2018,2015.2012 and 2009 International Building factory-made shingles to be used for covering hips and approximately 25 years old.Project scope will include removal and disposal of the existing roof assembly,and s •,1 • tt • '1 , , Codes(IBC) ridges.The hip and ridge shingles are composed of the installation of a new roof assembly. same materials as the roof shingles,Some of the hip and Y e .t\ _ ■2021, 2018, 2015. 2012 and 2009 international ridge shingles have perforations that extend from the top of i - Residential Coda°(IRC) the cut-out to the top of the shingle,which facilitate the IT should be known that this review shall •� •` ` - .* I ■2013 Abu Dhabi International Building Code(ADIBC), tearing of the shingle Into three or four equal pieces.Others • a� ` Snow stops required at all locations 9 9 P not relieve the applicant of their where roofs could shed snow onto "The ADIBC is weed an the 2009 IBC.2009 ISC cede sections referenced are manufactured as single hip and ridge units responsibility to comply with the t 911 .-. • • • - - nand report ere Om tame sections m Inc ADlsc. _ �,�' walkways,stairs,alleys,decks,exits, 3.4.2 Starter Strip Shingles:Starter Strip shingles are requirements of the City of Aspen USE OF BUILDING Single Family FIRE SPRINKLER REQUIREDt e t' • utilities and meters,emergency escape Properties evaluated: factory-made shingles to be used as the starter course Municipal Code.Pursuant to • _ and rescue opening window wells,orp N •■Weather resistance (under the first course of roof shingles).The Starter Strip Sec.26.104.O5O,any permit or approval e �" • r A adjacent properties-IBC 1513/COA ■Fire classification shingles are composed of the same materials as the roof issued in error or otherwise not in CLASS OF WORK Residential FIRE SPRINKLER TYPE r . I • t e • 8.20.020(z). •Wind resistance shingles.The shingles are supplied in 7-inch-by-36-inch- conformity with the requirements of this �- -- • long(178 by 914 mm): 10-inch-by-36-inch-long(254 by Title,shall be void.Similarly,anypermit �• •• „� El; 2.0 USES 914 min;or 7-inch-by-39%-inch-Ion (178 by1000 min N Heat trace/tape must be self-regulating 1 Y 9 ) or approval issued in reliance upon or REQUIRED SPECIAL \ Sit®ftlpg7/2 CertainTeed asphalt shingles described in this report ips. As an alternative to factory-made starter strips. BUILDING TYPE(IRC) INSPECTIONS • , type cable and must include automatic Roof Re lac with ASTM D3462 and are Gass A roof coveringsas a result of,a materially false controls and timer capable of turningp comply n9 s der strips can be formed by removing the lower tab e.' e P 22 W MEOW n installed as described in this report. portions of the factory-made shingles except for the statement or representation made in `� • off the system when the outdoor 3.0 DESC Presidential Shake and Presidential Shake TL shingles.For the process of obtaining the permit or CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE temperature is above 50 degrees and Presidential Shake and Presidential Shake TL shingles.the development approval shall,likewise, duringdaylight hours. 3.1 General: , be void.Anyperson havingreceived a Presidential Starter shingles consist of one 13/. inch-wide CerfainTeed asphalt shingles are available as three-lab, by-40-inch-long(337 mm by 1016 mm)base shingle and void or voidable permit or approval WORK CHANGES BUILDING four-tab, no cut-out and laminated asphalt shingle roof one 11'I,-inch-wide-by-40-inch-long(286 mm by 1016 mm) shall not be relieved from having to OCCUPANCY GROUP MCI covering materials.See Table 1 and Figure 1 for recognized base shingle. comply with all applicable terms and FOOTPRINT? product names, shingle types, manufacturing locations. • overall dimensions,installed weights,maximum exposure to 3.5 Fasteners: conditions of this Title and the City shall the weather,and fastening detains.The shingles are self- not be estopped from fully enforcing CODE EDITIONS 2015 IRC TOTAL SPASQ.FT. sealing by means of adhesive strips located on either the be minimumn must complyg with ASTM a ete and must same. m ,u..th.r erns r,r the,m,t.relrt. e..Elm,Ir.1 r r.ah.c,a. be No.12 gage[0.105-Inch-diameter(2-67 min) riiiMaiiOTHER CODE EDmONS TOTAL SNOWMELT SQ-FT. Roof Asset I Fly Listed Below I 03/2023 HISTORIC PROPERTY? No TOTAL POOLSQ.FT. FORCODELUMPLIANCE linzhid FIRE SPRINKLER EXISTING? 0 Proposed Roof Assembly Drawing—Show all layers/components from the roof sheathing up. Each component must k product and manufacturer name and existing to remain components and number of layers. Show flashing and ice bat ® Existing roofing and number of layers: 3 layers: 3/4" CDX ply, #15 bldg. paper, asphalt shingles