Loading...
HomeMy WebLinkAboutFile Documents.211 W Hopkins Ave.0078-2021-BRES (50) INSTALLATION GENERAL NOTES 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE 6. PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE A H i nes Inc IRRIGATION SYSTEM OF 90 PSI,AT A MAXIMUM DISCHARGE OF 10 GPM AT COMPLETION OF THE PROJECT: THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION(POC).TAP,METER, SITE WATER ENGINEERING SERVICES BACKFLOW,AND MASTER VALVE SHALL ALL BE THE SAME SIZE. VERIFY A. TWO(2)OPERATING KEYS FOR EACH TYPE OF MANUALLY 323W.DRAKE RD,SUITE 204 PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. OPERATED VALVES. City of Aspen Water Efficient Landscaping Ordinance City of Aspen Parks and Recreation Dept. FORT COLLINS,COLORADO 80528 585 Cemetery lane Telephone:970.282.1800 Pre-Submission Packet Completeness Review Aspen,CO 81611 Web:www.hlneslnc.com 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY THE CnvorASPEN WATER EFFICIENT LANDSCAPE WORKSHEET--WATER BUDGET ANALYSIS 970-920-5582 CONSTRUCTION. FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST Note:Project Applicant must complete this worksheet as it is a required element of the Landscape&Irrigation Documentation 3. COORDINATE UTILITY LOCATES("CALL BEFORE YOU DIG")OF UNDERGROUND PERFORMANCE. Package. UTILITIES PRIOR TO CONSTRUCTION. Address:211 W Hopkins Contact Info:I 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND CALCULATING GALLONS OF WATER NEEDED BY PLANT CATEGORY AND IRRIGATION TYPE Directions for Use WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE The specific irrigation water needs of each hydrozone in the design should be determined using the following formula and factors: DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS,LEGEND, PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT Irrigation Water Budget=[(ETo x Plant Factor)-Re]x Irrigated Area+Irrigation Efficiency x 0.623 Fill in these blue sections below.Some NOTES,OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION columns have drop down menus to OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF Where: assist you in filling out.The formulas REPRESENTATIVE. THE PIPE PASSING THROUGH. ETo=Reference Evapotranspiration in inches/season(May-Sept.) Reference Evapotranspiration will calculate the site average annual 5. THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE,THE FOLLOWING SHOULD 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN Re=Effective Precipitation in inches/season(May-Sept.) 27.4 inches/year water use.Once completed you may BE NOTED: ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE Irrigated Area=Hydrozone Area in Square Feet 17.1 gallons/square foot either attach this document to the LOCAL ELECTRIC UTILITY CODES. submital packet or insert it into t A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN Hydrozones Efficiency Effective Precipitation OUTSIDE PLANTING AREAS FOR CLARITY,INSTALL 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF Water Use Category Plant Factor Code 6.8 inches/year IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE WHENEVER POSSIBLE. UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE Cool Season Turf 0.90 VH r 4.2 gallons/square foot UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE High_ 0.80 H B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE NOTED IN THE LEGEND. Medium 0.65 M Irrigation Efficiency PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. Low 0.40 L Irrigation Method Default Efficiency AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM,PLANTING 11. INSTALL TWO(2)#14 AWG CONTROL WIRES ON STANDARD WIRE SYSTEMS Very Low 0.25 VL Overhead 75% MATERIALS,AND ARCHITECTURAL FEATURES. FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. Drip 90% C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION,OR USE OF CROSS TYPE FITTINGS IS NOT HYDROZON E WATER BUDGET CALCULATION ALLOWED. Complete the hydrozone table for each hydrozone. Use as many rows as necessary to provide the square footage of landscape are per hydrozone. Hydrozone Plant Water Need Hydrozone Plant Water Use Type(s) Plant Factor Irrigation Method Irrigation Efficiency Area IRRIGATION LEGEND CONSTRUCTION NOTES (Sq.Ft.) (gal/season) Zone lA Perennial L 0.40 Drip 0.90 379 1091 Zone 1B Shrub L 0.40 Drip 0.90 200 576 MA SLEEVES:CLASS 200 PVC Zone 1C Shrub - M 0.65 Drip 0.90 44 335 0 THE IRRIGATION SYSTEM POINT-OF-CONNECTION(POC)SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY Zone 2A Perennial L 0.40 Drip 0.90 186 536 I POINT-OF-CONNECTION ASSEMBLY OTHERS IN THE LOWER LEVEL MECHANICAL ROOM AT THE APPROXIMATE Zone 2B Shrub L 0.40 Drip 0.90 88 253 LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER Zone 2C Shrub M 0.65 Drip 0.90 44 335 - _ MAINLINE PIPE:CLASS 200 PVC VALVE ASSEMBLY AS INDICATED. VERIFY EXACT LOCATION OF POC WITH I y P grip 0.90 56 161 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED OWNER'S REPRESENTATIVE. Zone 4 Turf M 0.65 overhead 0.75 267 2442 - LATERAL PIPE TO SPRINKLERS: CLASS 200 PVC O2 WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE Zone 5 Turf M 0.65 'rip 0.90 201 1532 1-INCH SIZE UNLESS OTHERWISE INDICATED LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER Zone 6 Turf M 0.65 overhead 0.75 328 3000 r n WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL ,I r grip 0.90 970 7393 �J J LATERAL PIPE TO DRIP EMITTERS:UV RADIATION RESISTANT POLYETHYLENE THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR r r 3/4-INCH SIZE UNLESS OTHERWISE INDICATED,ROUTING IS DIAGRAMMATIC MAINTENANCE. FINAL LOCATION TO BE APPROVED BY OWNER'SZ REPRESENTATIVE. Kentucky Bluegrass(CST) OTAL 2763 17655 -- LATERAL PIPE TO TREE EMITTERS:CLASS 200 PVC is rated for Very High 1VERAGE IRRIGATION WATER NEED-ALL ZONES* In all ♦ / Water use(.90 plant " gallons/sq.ft./season 6.4 g 1-INCH SIZE UNLESS OTHERWISE INDICATED O THIS ZONE CONTAINS MIXED HYDROZONES. CONTRACTOR SHALL INSTALL factor).Revise the water O 'Theaveragemustbeless than the Maximum Applied Water Budget of7.5gallons/sq.t/season. ADDITIONAL DRIP EMITTERS TO MEDIUM-HYDROZONE SHRUBS TO MEET budget accordingly. ^ UNCONNECTED PIPE CROSSING NECESSARY WATERING REQUIREMENTS. 11 N Total area of irrigated public right-of-way: 639 Sq.Ft. L.f_ Z ESN INLINE DRIP TUBING:NETAFIM TLCV26-12 WITH RAINBIRD XQF DRIPLINE HEADER O THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION Total area of non-irrigated landscape: 0 Sq.Ft. 11-11 GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION 0 LL Q REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: DEVICE AT THE APPROXIMATE LOCATION SHOWN,PER CITY OF ASPEN D 1.1.117( REQUIREMENTS. = z III I I RAIN BIRD PEB(SIZED PER PLAN) W W w ® REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-100-PRB-COM O IRRIGATION SHOWN OUTSIDE OF LANDSCAPED AREAS FOR CLARITY ONLY. . Q II C INSTALL ALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREAS. C� I- O QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD SRC IRRIGATION PIPE SCHEDULE a ° C � ZCO N ISOLATION GATE VALVE ASSEMBLY:MATCO 514 CLASS 200 PVC PIPE 0 CS CC O ❑F FLOW SENSOR ASSEMBLY:RAIN BIRD FS100B SIZE FLOW(GPM) = U C 1" 0-15 CITY OF ASPEN GENERAL NOTES [� .� Z J N a a Cr) w 1-1/4" 16-25 Cl_ ap a m BACKFLOW PREVENTION ASSEMBLY.FEBCO 825YA 1-1/2" 26-35 1. APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT Eto'r U] 0 (JD 2" 36-55 EACH EMISSION DEVICE IS WITHIN THE MANUFACTURER'S L` u 3 CJ Q a CO a c0 Q ❑M WATER METER AND CURB STOP ASSEMBLY:BY OTHERS 2-1/2" 56-80 RECOMMENDED PRESSURE RANGE FOR OPTIMAL PERFORMANCE.IF 3" 81-110 PRESSURE IS NOT WITHIN THE PREFERRED RANGE,ACTIONS DESCRIBED Designed: BI.JB IN SECTION 6.1.10 OF THE WATER EFFICIENT LANDSCAPING Drafted: BI,JB m MASTER VALVE ASSEMBLY:RAIN BIRD PESB 4" 111-200 STANDARDS MUST BE TAKEN. Reviewed: MR 2. SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE • FLUSH CAP ASSEMBLY IF THERE IS A DISCREPANCY BETWEEN PIPE SIZES SHOWN ON MATCHED PRECIPITATION RATES,UNLESS OTHERWISE DIRECTED BY Date Issued: THE DRAWINGS AND THIS PIPE SCHEDULE,IT IS THE THE MANUFACTURER'S RECOMMENDATIONS. 02.DB.2019 RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE 3. ENSURE THERE IS HIGHEST POSSIBLE DISTRIBUTION UNIFORMITY,AND HEAD-TO-HEAD COVERAGE. Revision Title Date IRRIGATION DESIGNER FOR CLARIFICATION. 4. AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION INDICATES CONTROLLER AND STATION NUMBER MANAGEMENT PLAN IS REQUIRED AS DESCRIBED IN SECTION 6.7 1 Permit 2021.05.07 m �`-- INDICATES LATERAL DISCHARGE(GPM) THROUGH 6.9 OF THE STANDARDS. 2 WELS Comments 2021.07.29 ® s� INDICATES VALVE SIZE(INCHES) 4 _-_,,,, INDICATES LANDSCAPE APPLICATION a I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN -""- INDICATES PRESSURE(PSI) THE IRRIGATION DESIGN PLAN 6 7 © IRRIGATION CONTROLLER UNIT WITH RAIN SENSOR 3000 CELLULAR/ETHERNET/W I FI/CUP&STRING CONTROLLER A:RAIN BIRD ME3 ❑O LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 Sheet Title: o e • POP-UP SPRAY SPRINKLER:RAIN BIRD RD1806-S-P30 W/U-SERIES 15 NOZZLEilf-„ 07/29/2021 IRRIGATION LEGEND&NOTES PRESSURE:30 PSI RADIUS:15 FEET FLOW(GPM):Q-0.92 H-1.85 F-3.70 BRENT JEFFERY,CID DATE Sheet Number: ID#:23678 ® TREE BUBBLER ASSEMBLY:TWO(2)RAIN BIRD 1402 BUBBLERS I R 1 RECEIVED PRESSURE:30 PSI 09/13/2021 FLOW(GPM):0.50 PER BUBBLER;1.00 PER ASSEMBLY ASPEN BUILDING DEPARTMENT IRRIGATION LEGEND Hines Inc SLEEVES:CLASS 200 PVC SITE WATER ENGINEERING SERVICES 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 I- POINT-OF-CONNECTION ASSEMBLY Telephone:970.282.1800 Web:www.hlneslnacom — MAINLINE PIPE:CLASS 200 PVC 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED — LATERAL PIPE TO SPRINKLERS: CLASS 200 PVC 1-INCH SIZE UNLESS OTHERWISE INDICATED SULATERAL PIPE TO DRIP EMITTERS:UV RADIATION RESISTANT POLYETHYLENE 3 3 3/4-INCH SIZE UNLESS OTHERWISE INDICATED,ROUTING IS DIAGRAMMATIC SEPARATE DRIP ZONE TO SERVE EXISTING TREES A6 -- LATERAL PIPE TO TREE EMITTERS:CLASS 200 PVC 7.38 1-INCH SIZE UNLESS OTHERWISE INDICATED 1.. u 2.02 sL UNCONNECTED PIPE CROSSING - I 30 Ii 45;�� A5 r '` INLINE DRIP TUBING:NETAFIM TLCV26-12 WITH RAINBIRD XQF DRIPLINE HEADER . _ Al 0.87 �I� REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: .',: '. ''I t Oe 0.40 m RAIN BIRD PEB(SIZED PER PLAN) � p_�m�� 30 ® REMOTE CONTROL DRIP VALVE ASSEMBLY.RAIN BIRD XCZ-100-PRB-COM 02 : �,`� ,yd 'P '� ' i� r,•-1 A3 O QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD SRC tcti p' 10y,1 o0 .,42i� Dri. 30 45� D ��y ® N ISOLATION GATE VALVE ASSEMBLY:MATCO 514 USE AIR SPADING AND HAND DIGGING FOR ALL EXCAVATION WITHIN D R I P L I N E S OF ��� edi� SI 0.40 TREES,DO NOT PRUNE ANY ROOTS LARGER THAN 1.5".CITY FORESTER SHALL BE ti Wiz. �yJ DD�� � i �,'�9 " itivi \I�� S 30 F FLOW SENSOR ASSEMBLY:RAIN BIRD FS100B CONTACTED PRIOR TO ANY EXCAVATION EXERCISES,AND FOR INSPECTION UPON �,� ^°� _ �" �" .." s�r� v ��G m n. i,,,'_ r1/ I Z SEast va. ee-mail77- d I MAINLINE ROUTED OUTSIDE TREE DRIPLINE COMPLETION OF EXCAVATION PRIOR TO ANY FURTHER WORK. - i�u0�- I ��� .®o��.. cf A t:aii rag . $O m BACKFLOW PREVENTION ASSEMBLY:FEBC0825YA 41�1�e` I'll CTIO 0 79 ❑M WATER METER AND CURB STOP ASSEMBLY:BY OTHERS Ell �L�D�bA� 30 ., MASTER VALVE ASSEMBLY:RAIN BIRD PESB li �I „I 1L i(_ ii SEPARATE DRIP ZONE TO SERVEil © 1A 6 3 FLUSH CAP ASSEMBLY PROPOSED TREES,TYP. Oj# � '� , m 0.40 i101/64 '���1�4 ® 30 �/ INDICATES CONTROLLER AND STATION NUMBER cot':-11. �*i. I o I ®O m `� INDICATES LATERAL DISCHARGE(GPM) 5�8, �►PTO 4�L= `A INDICATES VALVE SIZE(INCHES) OL40A 1� � 114700:I�� ��f�S� f�� �� INDICATES LANDSCAPE APPLICATION 0 EN i( lw�4l)Ifib �� INDICATES PRESSURE(PSI) �� 5i'aa.>_ ��;�� -�� V�� �° OC ! :I:::30oo RIGATIONCONTROLLERUNITWI �� I� I� ' I �' ,. O z 11!. led 011 i Pere 'I���J�� i gui �ill ❑O CD ,1�® i���alnerg►.0 0 go __ al :sapIieRWMENFAIII 11 /�•� A. 0 1/ o e • POP-UP SPRAY SPRINKLER:RAIN BIRD RD1806-S-P30 W/U-SERIES 15 NOZZLE Z W •hy- I�� of el `, PRESSURE:30 PSI RADIUS:15 FEET ~ fiWA riri 410 I„ PAC 1 FLOW(GPM):Q-0.92 H-1.85 F-3.70 O L U U IV4'� so iy II SI O ® TREE BUBBLER ASSEMBLY:TWO(2)RAIN BIRD 1402 BUBBLERS w Ili L SIZE: W ',mid9 �• PRESSURE:30 PSI W PRESSURE:60 PSI •40 PI_ 1„ FLOW(GPM):0.50 PER BUBBLER;1.00 PER ASSEMBLY Q I- 04 08- FLOW:10 GPM r n F- ' �� ` I'• aCO zCO CONTROLLER ;� P ! �' CONSTRUCTION NOTES �, o o w a o 120 VAC POWER REQUIRED �4I5P II,1� y� 1'®I1 1 THE IRRIGATION SYSTEM POINT-OF-CONNECTION(POC)SHALL BE Z. °'C.() z �►" � �� °. O DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY o a :30 d 1 1 1 OTHERS IN THE LOWER LEVEL MECHANICAL ROOM AT THE APPROXIMATE o n �,I J - _ M Q t 0 CO __11 LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER L`u < 3 3DO ,� 0 ° ° VALVE ASSEMBLY AS INDICATED. VERIFY EXACT LOCATION OF POC WITH ms Designed: BI OWNER'S REPRESENTATIVE. Drafted: BI I ° Reviewed: MR •iiel,.1 — e ill O2 WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE 1 0-S!I J LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER Date Issued: WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL D2.06.2019 °, �' �> O -• THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR A Revision Title Date `°.. ° MAINTENANCE. FINAL LOCATION TO BE APPROVED BY OWNER'S 1 Permit 2021.05.07 ° ° ° REPRESENTATIVE. 2 WELS Comments 2021.07.29 ° 1 ,,,;„V-VV,,,,,;,,, , m 0 THIS ZONE CONTAINS MIXED HYDROZONES. CONTRACTOR SHALL INSTALL s ADDITIONAL DRIP EMITTERS TO MEDIUM-HYDROZONE SHRUBS TO MEET 4 c� I NECESSARY WATERING REQUIREMENTS. 5 S 5 5 S S S S S 0THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION 6 GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION DEVICE AT THE APPROXIMATE LOCATION SHOWN,PER CITY OF ASPEN REQUIREMENTS. 0 IRRIGATION SHOWN OUTSIDE OF LANDSCAPED AREAS FOR CLARITY ONLY. ID' I4 Ia' Its' INSTALL ALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREAS. SCALE 1''=6' N 0 R T H Sheet Title: IRRIGATION PLAN Sheet Number. I R-2 RECEIVED 09/13/2021 ASPEN BUILDING DEPARTMENT CALVE BOX WITH LOCKING COVER:6. SECURE CHRISTY ID TAG WITH NYLON A..._ Hines Inc ALUMINUM ENCLOSURE: BRAND LIDD WITH CARSON "MV" ZIP TIE. LABEL WITH CONTROLLER AND ITH STRONGBOX SBBC-3OAL OR STATION NUMBER. ,%/ y� y, FINISH GRADE GUARDSHACK GS-2 FINISH GRADE/TOP OF MULCH �� ii SITE WATER ENGINEERING SERVICES REDUCED PRESSURE BACKFLOW VALVE BOX WITH LOCKING COVER: � 323W.DRAKE RD,SUITE 204 ♦` REDUCED PREVENTER PER LEGEND SECURE CHRISTY ID TAG WITH NYLON VALVE BOX WITH COVER: FORT COLLINS,COLORADO 80526 ZIP TIE. LABEL WITH CONTROLLER AND CARSON 1419-46. BRAND "FM" ON 2-INCH MIN CARSON 910-4. Telephone:970.282.1800 0' �� � STATION NUMBER. LID W/ 3-INCH HIGH LTRS. BRAND LID WITH VALVE "IGV" Web:www.hIneslnc.com w w BRASS UNION (1 OF 2)�t•3>I ra�� 3/4-INCH MALE ADAPTER WITH PVC 30-INCH LINEAR LENGTH OF CAP 4-INCH PVC CL 200 PIPE COILED WIRE 1 FINISH GRADE TOP OF MULCH I 6-INCH CONCRETE PAD, 6-INCHES GRADE/TOP (LENGTH AS REQUIRED) ��I WATER PROOF CONNECTION (1 OF 2) TWO (2) CONDUCTOR TWISTED PAIR bo �oa°,0 LARGER THAN ENCLOSURE (EACH SIDE) o,= 3-INCH MINIMUM DEPTH OF Nri +� I','' ' MASTER VALVE, SIZE TO MATCH POC SHIELDED DIRECT BURIAL CABLE FOR o p o .�. 7�6 ,,�,�J17,f TYPE L COPPER (SIZED TO MATCH MODEL PER LEGENDCONNECTION TO TRANSMITTER °oo \• 3/4-INCH WASHED GRAVEL • BACKFLOW) it - --- 1 WATER PROOF CONNECTION (1 OF 2)a+ - 3M SERIES 7000 EPDXY KIT BRICK (1 OF 2) I 3-INCH MINIMUM DEPTH OF3-INCH SLEEVE (1 OF 2) FINISH c4 L 3/4-INCH WASHED GRAVELpi GRADE FLOW SENSOR PER LEGEND CLASS 200 PVC MAINLINE TO MASTER GATE VALVE WITH CROSS HANDLE, VALVE �n0 ` I._�1 PVC MAINLINE TO SYSTEM SIZED TO MATCH MAINLINE. MODEL SCH � � ' - �oOOo - MIN.10 PIPE DIA. s MIN.5 PI' DIA. PER LEGEND = _i!5 o='��0��:=-ireo'er= po�.OMAT 40 PVC MALE ADAPTER (SIZED TO Pg0\� STRAIGHT R;E°O �0� °dx;°o�0 STRAIGHT PIPE � _ MATCH BACKFLOW) „ e vo �eooeo amo ►, COPPER FEMALE ADAPTER BRICK (1 OF 4) 0 FLOW--► PVC MAINLINE PVC SCH 40 MALE ADAPTER (SPEARS "000 o°D°o O`o° 000 0. li� ���lil��� PVC MAINLINE _ TYPE K COPPER FROM METER (SIZED SR-2-0801) �'I °o O g0000°°c>7o°°oop 8 TO MATCH BACKFLOW) NON WOVEN LANDSCAPE FABRIC / `'o^^vo�po�,ago e°ooP^�� BRICK (1 OF 4) I �I PVC SCH. 40 MALE ADAPTER NOTES: (SPEARS 436 SERIES) 1. INSTALL BACKFLOW DEVICE IN ACCORDANCE WITH ALL STATE AND LOCAL CODE REQUIREMENTS. 3-INCH MINIMUM DEPTH OF 2. SLOPE TOP SURFACE OF PAD AT 0.5 %WITH BROOM FINISH. MAKE PIPE SLEEVES WITH 3/4-INCH WASHED GRAVEL NOTES: 1-1/2 INCH LARGER DIAMETER PIPE THAN PENETRATING PIPE SIZE. NON WOVEN LANDSCAPE FABRIC 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 3. ALL HINGED CONNECTION LOCATIONS AND HARDWARE TO BE TAMPER PROOF. 4. ALL WELD JOINTS SHALL BE CONTINUOUS AND GROUND SMOOTH. O UNIT ASSBACKFLO MBPRYVENTION ©ASSEMBLL MASTER YALVE © LOE LY SBENSORASS N GATE 4 VAOLVE ISLATO SEMBLY SECURE CHRISTY ID TAG WITH NYLON ZIP TIE. LABEL WITH CONTROLLER AND 2-4" 0 VALVE BOX WITH COVER: STATION NUMBER. -I IICARSON 910-4. VALVE BOX WITH COVER: CARSON r=Ta DRIP LINE TUBING LATERAL: 1/2" BRAND LID WITH VALVE "QC' 1419-4. • NETAFIM TECHLINE WITH 0.26 GPH 3-INCH MAX BRAND LID WITH VALVE NUMBER FINISH GRADE • 1 EMITTERS 12" O.C. (TYP) MODEL FINISH GRADE FINISH GRADE TOP OF MULCH 12" TLCV26-12 ' / TECHLINE TEE 6^ • � QUICK COUPLING VALVE PER LEGEND IF rjWATER PROOF CONNECTION (1 OF 2) 16 REMOTE CONTROL VALVE REFER TECHLINE TUBING TO DETAIL X '/%4 L. STAINLESS STEEL HOSE CLAMP j 30 INCH LINEAR LENGTH OF WIRE, # ØI (1 OF 2) �� M I� • PVC SUPPLY HEADER REMOTE CONTROL VALVE, SIZED AS _ 36-INCH No. 6 EPDXY COATED REBAR SHOWN ON DRAWINGS 3-INCH DEPTH OF 3/4-INCH WASHED 4SPEARS PVC TRUE UNION BALL VALVE GRAVEL WM; a.- ilaiIE_I II APPROVED GEOTECH FILTER FABRIC o`�o°°�rim ''VCre'o°1 11 BRICK OF BLANK TECHLINE '0000 0 %' cA°11 (12) / 000e o o„-. ...,..,..0 00° am (EXTEND 10" UP BOX WALL) - - // �O,3 1-�eAwn �/ -SCH 80 PVC NIPPLE, TOE 2o.oe'.° 0ez>0i (;° ° `� TUBING TECHLINE START CONNECTION Ili` _��`a_ PVC SCH 80 PIPE (LENGTH AS (LENGTH VARIES) , ■-' � REQUIRED) • ' • • (PVC TO ELL): REFER TO PRE FABRICATED SWING JOINT: PVC MAINLINE TECHLINE 3/4" DETAIL #X Z _ SPEARS 5815-010-10 • ��� MALE ADAPTERCO • . , BRICK (1 OF 4) l AREA PERIMETER ■) a PVC MAINLINE PIPE PVC SCH 40 TEE OR EL PVC TEE (SxSxT) LOOP 1' OF 2 SPARE WIRES PVC PIPING PVC EXHAUST HEADER \\* • COMBINED PRESSURE REGULATOR SCH 40 PVC TEE OR EL WITH FPT AND Y-STRAINER • • P FLUSH CAP ASSEMBLY PLUMBED TO 0 OUTLET 3.0-INCH MINIMUM DEPTH OF PVC (TYP) ^ p 3/4-INCH WASHED GRAVEL CURB OR PLANTING BED EDGE ' 1CU NOTE: CL 1. USE BARBED INSERT FITTINGS ON DRIP LATERAL PIPE WITH STAINLESS STEEL HOSE 1.NOT INSTALL SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS 0 CLAMPS. PLACE CLAMPS ON DRIP TUBING DIRECTLY OVER BARBED AREA OF FITTING. FOR EQUIPMENT APPLICATION AND INSTALLATION. • PINCH CLAMPS ARE NOT ACCEPTABLE. • 2. MAXIMUM FLOW FOR 1-INCH REMOTE CONTROL VALVE ASSEMBLY IS 10 GPM. W LLJ (f] 3. INSTALL AT A DEPTH OF 4'"-6" IN UNIFORM SOIL. i z LLJ QUICK COUPLING 6 REMOTE CONTROL DRIP PVC TECHLINE 8 SUBSURFACE DRIP > w it O VALVE ASSEMBLY VALVE ASSEMBLY O CONNECTION ASSEMBLY IN SHRUB BEDS m CD w co coV z ao VALVE BOX WITH COVER: CARSON MAINLINE, LATERAL, PIPE AND WIRE PLANT TYPE BY EMITTERS GPH PER TOTAL GPH LATERAL PIPE 0 CO D O d O 910-4, BRAND LID WITH IRRIGATION 24-V WIRE SLEEV NC N(J] COMPONENT (CV) HYDROZONE PER PLANT EMITTER PER PLANT Z . n DIFFUSER BUG CAP: FINISH GRADE CONCRETE SLAB W J 9 W RAIN BIRD MODEL DBC-025 0� a ao a -III �-FINISH GRADE LOW WATER USE TREE 3 SINGLE 1 GPH 3 GPH o 2 r (n uD II-II 1/4-INCH TUBING STAKE: 11-I I I- RAIN BIRD #TS-025 �� � a`��N < �� < I- 1/4-INCH DISTRIBUTION TUBING MED WATER USE TREE 4 SINGLE 1 GPH 4 GPH j 18„ Designed: BI =I IN LINE CHECK VALVE: � 24" /i 1 Drafted: BI 1 REFER TO NOTES BELOW HIGH WATER USE TREE 3 SINGLE 2 GPH 6 GPH Reviewed: MR MULCH BED POLY MALE ADAPTER LOW WATER USE SHRUBS 1 SINGLE 1 GPH 1 GPH 4 O 4 � 24 Date Issued: 4" 02.06.2019 L DRIP LATERAL POLYETHYLENE PIPE DRIP EMITTER MED WATER USE SHRUBS 2 SINGLE 1 GPH Sc0.5 GPH 1.5 GPHb T REFER TO SPECIFICATIONS T 4 ( ) Revision Title Date ( _ C j// 1// /j////////// HIGH WATER USE SHRUBS 2 SINGLE 1 GPH 2 GPH ; Permit 2021.05.07 o I l0 0 0 o o° °°ovog"I / / / /� Cy T4 z WELS Comments 2021.07.29 �` a o °o° 00� °°oo°°000 // LOW WATER USE PERENNIAL 1 SINGLE 1 GPH 1 GPH T 3 g vo opo o sT ° pooPr-BRICK (1 OF 2) EXCAVATED MATERIAL FINSH GRADE MED WATER USE PERENNIAL 2 SINGLE 1 GPH & 0.5 GPH 1.5 GPH PIPE WIRING 3-INCH DEPTH OF 3/4-INCH ��������� � �������������������'��\� < BEDDING& COVER MATERIAL SLEEVE SLEEVE s WASHED GRAVEL A \�V A\ V V A A V V V V�� a HIGH WATER USE PERENNIAL 2 SINGLE 1 GPH 2 GPH WARNING TAPE POLY MALE ADAPTER 7 DRIP LATERAL PIPE NOTES: 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. NOTES: I PLANT ROOT BALL NOTES:1. ALL EMISSION POINTS TO BE LOCATED ON THE UPHILL SIDE OF PLANT 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS."SNAKE" UNSLEEVED 1. DRIP LATERALS WITH MORE THAN 4 GPM SHALL UTILIZE THE HUNTER HCV IN-LINE MATERIAL. PLASTIC PIPE IN TRENCH. PROVIDE A MINIMUM OF 2" CLEARANCE TO SIDE OF TRENCH CHECK VALVE. AND BETWEEN PIPES. 2. ALL EMITTER QUANTITIES AND FLOW RATES ARE FOR RECOMMENDATION ONLY. I0' I2.5' 15' 110' 2. DRIP LATERALS WITH LESS THAN 4 GPM SHALL UTILIZE THE NETAFIM TLCV050M1-B 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE IN-LINE CHECK VALVE. THE CONTRACTOR SHALL CONSULT AND CONFIRM WITH LOCAL PRACTICE PRIOR REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP SCALE:1"=5' N 0 R T H TO INSTALLATION. AT ALI CHANGES OF DIRECTION OVER 30 DEGREES. Sheet Title: IN LINE DRIP CHECK0 SINGLE OUTLET DRIP EMITTER SCHEDULE 4111 TYPICAL TRENCHING IRRIGATION PLAN 9 VALVE ASSEMBLY 1 EMITTER ASSEMBLY DETAIL Sheet Number: I R-3 RECEIVED 09/13/2021 ASPEN BUILDING DEPARTMENT • CHRISTY ID TAG ��PROPER RAIN/FREEZE/WIND SENSOR; A..... Hines Inc PAVED SURFACE I. _ PROPERLY MOUNTED ON POST OR ' FINISHED GRADE GUTTER TO RECEIVE FULL SUN, OPEN CURB AND GUTTER IF APPLICABLE TO RAINFALL AND OUT OF SPRINKLER SITE WATER ENGINEERING SERVICES T I! In in�lir COVERAGE. 323 W.DRAKE RD,SUITE 204 T =, m IRRIGATION CONTROL WIRES SECURED TO BOX WITH NYLON ZIP TIE. WALL MOUNTED CONTROLLER FORT S,COLORADO 80526 I� (REFER TO LEGEND FOR MODEL) Telephone:970.282.1800 36" I 1 IRRIGATION VALVE/SENSOR ASSEMBLY Web:www.hineslnc.com 12" MIN (ABOVE GRAVEL) COMMUNICATION WIRE INSTALLED IN CONDUIT; MAX WIRE DISTANCE: 200'. 1 3.0-INCH MINIMUM DEPTH OF 2 WALL ROUGH GRADE (WIRELESS OPTIONAL; REFER TO LEGEND) IUP 11 3/4-INCH WASHED GRAVEL III- g5�off' ° 120 VOLT POWER SUPPLY WIRES IN I III III 2"PVC PIPE SLEEVE MARKER: INSTALL AT �� o,�°e"=sogro°a smo °o' BRICK (1 OF 4) Ih METAL CONDUIT BOTH ENDS OF EACH SLEEVE LOCATION AND APPROVED GEOTECH FILTER FABRIC • EXTEND AT LEAST 3'ABOVE GRADE. SPRAY PVC CONDUIT FOR CONTROL WIRES /////�/// HEHH,111 HE, III III- EXPOSED PORTION OF MARKER WITH GREEN (EXTEND'10' UP BOX WALL) MINIMUM 10 F..f III III—III =) �II TO LANDSCAPED AREA II III III- FLUORESCENT PAINT. •STANDARD QUICK n COUPLER OR ISOLATION PVC SWEEP ELL ! #6 BARE COPPER GROUNDING WIRE IN 24-INCH MIN ° I� �I, METAL CONDUIT GATE VALVE BOX 1 5' SIZE 4"-6'" MIN. PAVEMENT ( =; 74 4 g�Zp@ L FINISH GRADE a `; • III®-L �� a III rii ill-th— — PVC SWEEP ELL • STANDARD CARSON 1419 - �. 4"-6"MIN. MIN 12" MIN 12" - REMOTE CONTROL VALVE 1� DIRECT BURIAL CONTROL WIRES TO I MIN 12" BOX ' CONTROL VALVES SEAL ENDS OF SLEEVES WITH CLOTH - TURF OR PLANTING BED COPPER GROUNDING WIRE DUCT TAPE (TYPICAL) .: TO BRONZE CLAMP. PVC SLEEVING (TYPICAL) a�,�. 1* COPPER CLAD GROUND ROD a PAVEMENT.OR EDGING RESTRAINT NOTES:. " (5/8" X 8') PAIGE ELECTRIC NOTE: 1. INSTALL ONLY ONE RCV TO VALVE BOX. LOCATE AT LEAST 12-INCHES FROM NOTES: PART NUMBER 182007. 1) ALL SLEEVING TO BE CLASS 200 BE PVC, SIZED AS NOTED. AND ALIGN WITH NEARBY WALLS OR EDGES OF PAVED AREAS. GROUP RCV 1. INSTALL ALL WIRING PER LOCAL ELECTRICAL CODES. 2) INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ASSEMBLIES TOGETHER WHERE PRACTICAL. 2. INSTALL GROUND ROD WITHIN IRRIGATED TURF AREA. IF IRRIGATED TURF AREA IS NOT IN ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES 4. GROUP RCV ASSEMBLES TOGETHER WHERE PRACTICAL, BUT AVOID GROUPING CLOSE PROXIMITY TO CONTROLLER, INSTALL ONE (1) DRIP EMITTER FROM NEAREST DRIP VERTICALLY. MORE THAN THREE (3) STANDARD VALVE BOXES TOGETHER IN A SERIES. VALVE IN VALVE BOX HOUSING GROUNDING ROD. 5. ARRANGE GROUPED VALVE BOXES IN RECTANGULAR PATTERNS. TYPICAL SLEEVING DETAIL 14 TYPICAL VALVE BOX WALL MOUNT INSTALLATION CONTROLLER ASSEMBLY PROFILE VIEW PLAN VIEW IRRIGATION CONTROLLER. #6AWG SOLID BARE COPPER WIRE #6AWG SOLID BARE COPPER WIRE 4" X 96" X Xs" 1 COPPER GROUNDING PLATE p12" MIN +► '-'\ i /1'r14`1411,A)(1)1144i(YA4IwG N 411,6-y�k1w,/lA _il,L, 4)/Q4lk�l�kAki4M �UAk6(UrrWJ4, \\ GROUNDING CLAMP 3L �\+�i� � CONNECTION ��/ ���YYY 3W 30" MIN L W - I C J _, L L L T 3L <E / / I i�i/ - 4" X\$6" X Ys" 2L I I // � COPP'ER,GROUNQ PLATE \ \ / I / / \ \ \ V v / / / / / /� � V ACO �� �� #6AWG SOLID COPPER BARE WIRE \ 1-------#6AWG SOLID BARE COPPER WIRE I I ( \ \I \I Z _ _ 1 / 5/8"X10' GROUNDING ROD. \ / / \(C �)�ELECTRODE SPHERE OF INFLUENCE \\ \ \ // // / 0 \ \ L _ / / / / Cl N / / Z w NOTES: — / 0 1. INSTALL GROUNDING ROD OR PLATE BASED ON SITE CONDITIONS, DO NOT INSTALL BOTH. LL W (J] 2. DO NOT INSTALL ANY OTHER WIRE OR CABLES INSIDE THE SPHERE OF INFLUENCE. -- 3. INSTALL GROUNDING PLATE AT A MINIMUM OF 30-INCHES BELOW GRADE OR BELOW FROST-LINE, WHICHEVER IS DEEPER. 4. TYPICAL INSTALLATION SHOWN FOR AN IRRIGATION CONTROLLER CAPACITY OF 64 STATIONS OR LESS, INSTALL AN ADDITIONAL GROUNDING ROD/PLATE PER 64 STATIONS. 1 w w Lit 16 TYPICAL IRRIGATION CONTROLLER GROUNDING ROD OR PLATE INSTALLATION CO I- 4 CO 0 o CO oo w EL ac w � w.. fj a ao a Designed: BI Drafted: BI Reviewed: MR Date Issued: 02.06.2019 Revision Title Date ° Permit 2021.05.07 2 WELS Comments 2021.07.29 3 4 5 6 7 IO' 12.5' 15' 110' SCALE:1"=5' N 0 R T H Sheet Title: IRRIGATION PLAN Sheet Number: I R-4 RECEIVED 09/13/2021 ASPEN BUILDING DEPARTMENT