Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.635 W Bleeker St.0104-2023-BROF (11)
ICC ESEVALUATION SERVICE ICC-ES Evaluation Report ESR-1410 Reissued June 2020 This report is subject to renewal June 2022. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE shakes and shingles have higher levels of chemical PROTECTION retention than the "Class C" treated shakes and shingles. Section: 07 31 29—Wood Shingles and Shakes Fire-retardant-treated starter course materials are supplied by FSR Treatment, Inc. or Chemco, Inc. and are produced REPORT HOLDER: from No. 2 grade taper sawn shakes or No. 2 grade shingles complying with the previously referenced code FSR TREATMENT, INC. sections, and are also available in "Class B"and "Class C." Products are sold under the trade names FSR FTX. ADDITIONAL LISTEE: 4.0 DESIGN AND INSTALLATION CHEMCO, INC. 4.1 General: EVALUATION SUBJECT: The wood shakes and shingles must be installed on spaced or solid sheathing complying with the applicable FSR, FTX, FIRE-RETARDANT-TREATED WOOD code. The wood shakes must be installed in accordance SHAKES AND SHINGLES with IBC Section 1507.9, IRC Section R905.8 or UBC Section 1507.12. The wood shingles must be installed in 1.0 EVALUATION SCOPE accordance with IBC Section 1507.8, IRC Section 905.7 or UBC Section 1507.13. Fasteners must be stainless steel Compliance with the following codes: complying with ASTM A580 Type 304 or 316. The wood • shakes must be installed on roofs with a minimum slope of 2012, 2009 and 2006 International Building Code®(IBC) 4:12 (33%), while wood shingles may be installed on roofs • 2012, 2009 and 2006 International Residential Code® with a minimum slope of 3:12 (25%). (IRC) Weather exposure of the hip and ridge shakes or • 2013 Abu Dhabi International Building Code(ADIBC)t shingles must not exceed those exposures permitted for the field of the roof. tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced in this report are the same sections in the ADIBC. Starter courses at the eave must be doubled, with • 1997 Uniform Building CodeTM (UBC) the first course being full-size treated shakes or shingles or 15-inch (381 mm) treated starter-course shakes or Properties evaluated: shingles. Fifteen-inch (381 mm) or 18-inch (457 mm) • Roof covering treated shakes or shingles may be used for the final course at the ridge. • Fire classification 4.2 Class A Roof Covering: 2.0 USES Products labeled as "Class B" shakes or shingles must be The fire-retardant-treated wood shake and shingle roof installed in accordance with Section 4.1 of this report, over coverings are for use where Class A, B or C wood roof spaced or solid sheathing covered either with one layer coverings are permitted. of 1/4-inch-thick (6.4 mm) Dens-Deck® Roof Board, 3.0 DESCRIPTION manufactured by Georgia Pacific Corporation, or with one layer of mineral-surfaced cap sheet complying with The fire-retardant-treated wood shakes and shingles are ASTM D3909. Where underlayment is required, the produced from No. 1 grade western red cedar shakes underlayment shall be installed over the Dens-Deck®board complying with IBC Section 1507.9.6 (2012 and 2009 or mineral-surfaced cap sheet. Fastener length for the codes and 1507.9.5 (2006 code), IRC Section R905.8.5 or shakes or shingles must be increased for the thickness of UBC Section 1507.12, or No. 1 western red cedar shingles the Dens-Deck board or cap sheet. The Dens-Deck boards complying with IBC Section 1507.8.5 (2012 and 2009 must be fastened to spaced or solid sheathing using a codes)and 1507.8.4 (2006 code), IRC Section R905.7.4 or minimum of four fasteners per board to avoid panel shifting UBC Section 1507.13. The shakes and shingles, having a prior to installation of the shakes or shingles. The mineral- maximum moisture content of 25 percent, are pressure- surfaced cap sheet must be installed with 2-inch (51 mm) treated by FSR Treatment, Inc. or Chemco, Inc., with overlaps on the sides and ends, and attached with a proprietary fire-retardant chemicals. Treated products are sufficient number of fasteners to hold the sheet in place identified as "Class B" or"Class C." The "Class B" treated prior to installation of the shakes. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ANS. as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i w 6:1“ to any finding or other matter in this report,or as to any product covered by the report Copyright©2020 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 3 ESR-1410 I Most Widely Accepted and Trusted Page 2 of 3 4.3 Class B Roof Covering: 7.0 IDENTIFICATION Products labeled as "Class B" shakes or shingles must be 7.1 Bundles of treated wood shakes and shingles must installed in accordance with Section 4.1 of this report, bear a label noting the shingle or shake grading except that for shake installation a 36-inch-wide (914 mm), agency name and compliance with the grading Type II underlayment, complying with ASTM D226, must standards noted in the applicable code. An additional be installed under the 15-or 18-inch-long (381 or 457 mm) label, affixed to each bundle, must bear the treater's starter course at the eave line. name (FSR Treatment, Inc. or Chemco, Inc.), the 4.4 Class C Roof Covering: product name, the name of the inspection agency (ICC-ES and Fire Tech Services, Inc.), the fire Products labeled as "Class C" shakes or shingles must be classification and the evaluation report number(ESR- installed as described in Section 4.3 of this report for the 1410). Labels for "Class B" shakes must be printed Class B roof covering. with red ink and labels for"Class C" shakes must be 5.0 CONDITIONS OF USE printed with blue ink. See Figure 1 and 2 of this report for product treatment labels. The FSR Treatment, Inc., FTX fire-retardant-treated shakes and shingles described in this report comply with, Starter-course shingles and shakes must be or are suitable alternatives to what is specified in, those identified with a label bearing the treater's name(FSR codes listed in Section 1.0 of this report, subject to the Treatment, Inc. or Chemco, Inc.), the product name following conditions: (Starter-Course), the name of the inspection agency (ICC-ES and Fire Tech Services, Inc.), the fire 5.1 The shakes and shingles are treated, identified and classification, the evaluation report number (ESR- installed in accordance with this report. 1410) and the words "To be used as starter course 5.2 The use of the Class B and C shakes and shingles is only." Labels for "Class B" starter course materials limited to use on roofs where the respective must be printed with red ink and labels for "Class C" classification is permitted, except that the Class B starter course materials must be printed with blue ink. shakes and shingles are permitted to be used on 7.2 The report holder's contact information is the roofs required to have a Class A roof covering where following: they are installed as part of the assembly described in FSR TREATMENT, INC. Section 4.2 of this report. 9486—288TH STREET 5.3 The shakes and shingles are pressure-treated MAPLE RIDGE, BRITISH COLUMBIA V2W 1L1 by FSR Treatment, Inc., in Maple Ridge, British CANADA Columbia, Canada; and Chemco, Inc. in Ferndale, (604)462-0640 Washington under a quality control program with www.firesmartroofing.com inspections by ICC-ES and Fire Tech Services, Inc. 7.3 The Additional Listee's contact information is the (AA-641). following: 6.0 EVIDENCE SUBMITTED CHEMCO, INC. 6.1 Data in accordance with the ICC-ES Acceptance POST OFFICE BOX 875 Criteria for Classified Wood Roof Systems (AC107), FERNDALE,WASHINGTON 98248 dated September 2004 (editorially revised February (360)366-3500 2014). www.chemco.us 6.2 Treater's published installation instructions. 6.3 A quality control manual. ESR-1410 I Most Widely Accepted and Trusted Page 3 of 3 Class C Fire Retardant WWI. Class B Fire Retardant F• - ICC ESR•1410 g7 r ti ICC ESR-1410 ',A 'ti FIRE TECH SERVICES INC.ISSAOUAH.WA O FIRE TECH SERVICES INC.ISSAOUAH.WA 0 O.C.INSPECTION AGENCY O.C.INSPECTION AGENCY ` PRESSURE TREATED AA-64t LISTING NO.541B - PRESSURE TREATED M•641 LISTING NO.50111 Iti• SHAKES AND SHINGLES Treated by ESA TREATMENT INC '"'!!l1O3333�c____ . SHAKES AND SHINGLES Treated by FSR TREATMENT INC � MUST BE APPLIED A ACCORDANCE 9486 2BBIn Si Mape Ridge.BC,112W tU Fq t Gam: MUST BE APPLIED Al ACCORDANCE 9486-29815 St Mope F4dge.BC,V2A jS`q"v.G': WRX APPLICATION INSTRUCTIONS PIA 604462-0640 PIP 604462-X40 INCLUDED 1VITH THIS ROOFING ISSUE# I a415461T. 101 I WITH APPLICATION INSTRUCTIONS I f415G1735-101 I INCLUDED WITH THIS ROOFING ISSUE A ',.', CERT1-GUARD® CERTI-GUARD® FIRE TECX SERVCES INC. (/fsw(5\I FIRE TECH SERVICES INC. O Pressure-Treated Fire Retardant Shingles O.C.INSPECTION AGENCY C W j Pressure-Treated Fire Retardant Shingles O.C.INSPECTION AGENCY 1 ,1 and Shakes.Cedar Shake&Shingle Bureau ca l LS ING NO.SOlE I ,11, .. and Shakes.Cedar Shake&Shingle Bureau AA341 USTR4G NO.5018 FSR Treatment Inc.9486-288th ST.Maple Ridge.B.C.V2W 1 L1 1{I04►442440 FSR reatment Inc.9486.2::+ ST..Maple•idge,B.C.V2W 1 L1 1•(I04) I ' Legal for use and sale In California•t;FSf:I .'w 1150-1735-101 FSR TRMT INC Legal for use and sale In Caw •CFSM Ustee 1150-1735-101 FSR TRMT INC CLASS "B" FIRE RETARDANT ICC ESR-1410 CLASS "C" FIRE RETARDANT ICC ESR-1410 <•; �' CLASS "B" Fire Retardant F CLASS "C" Fire Retardant Passed the 10 year weathering test(Report no. .� Passed the 10 year weathering test(Report no �: FTT 21060-3).Health and Safety Code 13132(j) e'�4�71; FTT 21060-3).Health and Safety Code 13132(0 .•m...- �' and ICC ES EG 107 Listed with the California State `�;,;�a� �• and ICC ES EG 107 Listed with the California State 1:+.,n,�l (its) Fire Marshal#04150-1735-101 FSR Treatment Inc. lCl jl lftsi Fire Marshal#04150-1735101 FSR Treatment Inc. Fire Tech Services Inc. ICC ESR-1410 Fire Tech Services Inc. ICC ESR-1410 C.C.Inspection Agency ISSUE# C.C.InspectionAgency ISSUE# AA.641 Listing no.501 AAb no.501 41 Lusting no.501 FIGURE 1—PRODUCT TREATMENT LABELS FSR TREATMENT INC. Class C Fire Retardant f_ ! ! ?� ICC ESR-1410- emaAe WA 9F24V o ,Lr I -- "� - -- rl -,yy _ FINE TECH SFFJ[ES is: SSA0.11M WA ` Fire rated roofingper UL 790,ULC-5.107-M UBC-15.2 J PRESSURE TREATED 0- IISFECTIQI AGENCY WA377 LISTING NO.sot B O•- �`'�_ ,.,,_'�, ASTM•E-108.ICC ESR 1410.NFPA 256 when applied in SHAKES AND SHINGLES Tr5;rte0 by CHEW()INC :1•+'"'"7j.„ accordance with installabon instructions Issued with this roofingOUST BE APPLIED W ACCORDANCE 41e1 GwrWlew ITd FerrdWe WA.9i.' - -lot-`^'••�,i WRN APPLICATION INSTRUCTIONS Plir 1-604-46 064A 'a V 1 Legal for use in Califomia ICC Class"C"FireRetardant INCLUDED him THISROORNG ISSUE A Ia150.1735-I0lI "' CLASS "C" Fire Retardant LEGAL FOR SALE AND USE IN CALIFORNIA '�� Complies with wealhenng requiremens of State of California Passed the 10 year weathering test(Report no Hemel arc�alcry COSA tat i2 rip aria ICC ES EG t FTT 21060-3) Health and Safety Code 13132(j1 i ",,,•j � and ICC ES EG 107 Listed with the California Stag "`"' ' ° ' -' "r _ I:I! 'r "a"Le (ftsl Fire Marshal#04150-1735'101 FSR Treatment Inc FimleciSeceicesinc. ICC ESR-1410 C.C.inspocuon Agency k Chec withLocal Build ing Official for anyadditional M•841 Listing no.5010 ISSUE# requirements or restriction. Front and Reverse Front and Reverse FSR Treatment Class C FTX Class C FSR TREATMENT INC. Class B Fire Retardant ' ir"4.13 '.,r ICC ESR-1410 T.:- T'b` f,-\ i FIRE TECH SERVICES INC ISSAOUAH.WA O ( ° Fire rated roofingper UL 790 ULGS-107-M UBC 15-2 PRESSURE TREATED O.C.INSPECTION AGENCY PMi41 LISTING NO.SO1B _O \ ASTM-E-108,ICC ESR-1410,NFPA 256 when applied in SHAKES AND SHINGLES y aInd by CHEMCO INC •i'n'iAIiI)+accordance with installation instructions issued with this roofing. HOST RE APPLIED IN ACCORDANCE 4191 Gr4rdvn rid Fertidale.YJA.V.. �S. 0- -I WITH APPLICATION IN$TROCTANS PM 1.604.462.0640 " q V• 1i Legal torus,in California ICC Class"B"Fire Retardant IHnuorowm+Iins HOOF NG ISSUE. IM15011751011 iltd- CLASS "B" Fire Retardant LEGAL FOR SALE AND USE IN CALIFORNIA (0) Passed the 10 year weathering test(Report no Complies with weathering requirements of State of G FTT 21060-31.Health and Safety Code 13132tj1 Health and Salery Code 13132.710 and ICC ES EG 107 and ICC ES EG 107 Listed with the California State Passed the 10 year natural weather lest iRepon no.FIT 210eU T • mdvain CN 1a Marshal .", - Fire Marshal#04150-1735 101 FSR Treatment Inc is+nano 04150 1735 Ill Fin Tech SerfiCeSInc. ICC ESR-1410 G.C.lnegclbn Agency ISSUE# Check with Local Building Official for anyadditional AA141 Listing no.50189 requirements or nalAetiom Front and Reverse Front and Reverse FSR Treatment Class B FTX Class B FIGURE 2—PRODUCT TREATMENT LABELS FOR CHEMCO,INC.