Loading...
HomeMy WebLinkAboutFile Documents.909 E Hopkins Ave.0056-2021-BRES (18) 0056-2021 -BRES_ZoningComments_1 10.Address Request.905 E Hopkins Lot 2.2021.03.09.pdf(1) Subject:Text Box Page:4 Please submit this request to Page Index: 4 comdevaddressing@cityofaspen Author: haleyh .com • Color: • Request previously submitted, ige Request File Name: 10.Address Request.905 E Hopkins Lot Dame ee� et 2.2021.03.09.pdf Assignment granted, Ref. Document "10.Address Assignment.909 E Hopkins (905 Lot 2) " 90.Architectural Plans.905 E Hopkins.2021.03.26.pdf(6) 7771 �POG7 gxr 0,= Subject: Cloud+ OVER Page: 5 Please ensure that this will be in Page Index: 5 conformance when built.This ,m does not leave very much room Author: haleyh �..,.d.,.., ti.�.. — s Color: • for error for max height(25'). File Name: 90.Architectural Plans.905 E Understand: Type Five Builders (GC)to comply& Hopkins.2021.03.26.pdf verify; Zoning Compliance Verification Policy Form has been included with the Permit Submission. Licensed Surveyor to be retained to spot check elevations throughout framing process. Subject: Cloud+ E. Page: 6 Verify that condensor and pad m Page Index: 6 height total is no greater than Author: haleyh 30"per 26.575.020.5.N(4): "If Color: •� — located within a setback not = ' File Name: 90.Architectural Plans.905 E adjacent to a street,these Hopkins.2021.03.26.pdf features shall not exceed thirty (30)inches above or below Sheet A-001, Keynote 3 clarified: Mfr. equipment finished grade. These features ._._. _._._. specifications subject to change, or substituted. GC may be up to thirty(30)inches notified to check requirements and verification prior to above and below finished grade ordering product. simultaneously." Subject:Text Box Page: 8 Is this floor area sheets or fire Page Index: 8 area sheets? If this is fire area Author: hale h please revise sheet name to Is this floor area sheets or y reflect correct FAR. fire area sheets?If this is Color: • re a a ple oerfec sheet name t to reflect File Name: 90.Architectural Plans.905 E Sheets Z-001 and Z-002 are FAR Calculations. t correct FAR. Hopkins.2021.03.26.pdf Sheet A-003 is the Fire Area Calculations and has been re-named. Subject: 3/16"Scale Page: 9 3' 3" Page Index: 9 Sheet A-101 Basement Floor Plan, Keynote 4 Author: haleyh clarified. House siding to continue down into window Color: ■ well -clarified. File Name: 90.Architectural Plans.905 E Hopkins.2021.03.26.pdf RECEIVED 10/07/2021 ASPEN BUILDING DEPARTMENT Subject: Cloud+ } o �;;' m��," Page: 9 Window wells in setback per LrimL building code must be 3x3'max. r lm r Page Index. 9 d rii Author: haleyh i 6; ;;` Color: ■ LI ` ari_ File Name: 90.Architectural Plans.905 E EliII Hopkins.2021.03.26.pdf ;E Subject:Text Box Page: 14 This needs to go back through Page Index: 14 RDS-these do not match the This needs to go back Author: haleyh stamped RDS sheets. Please through RDS-these do not get back in touch with Garrett to match the stamped RDS Color: • sheets.Please get back in File Name: 90.Architectural Plans.905 E amend. touch with Garrett to amend. Hopkins.2021.03.26.pdf DONE: Reference Document"20.RDS Approval.909 E Hopkins (905 Lot 2) " 90.Lighting Plans and RCPs.905 E Hopkins.2021.03.26.pdf(1) Subject:Text Box Page: 5 We are missing exterior Page Index: 5 cut-sheets on the following Author: haleyh lights: L12, L11, L5E and any We are missing exterior other exterior lights. cut-sheets on the following Color: • anyligyts:other exterior L5E ats. File Name: 90.Lighting Plans and RCPs.905 E lights. Hopkins.2021.03.26.pdf 1.L5E is used only in shower niches. 2.L11 is used only in interior storage closets. 3.Cutsheets for L2, L12, L15, L16, and D1 are attached. These are the only exterior fixtures. RECEIVED 10/07/2021 ASPEN BUILDING DEPARTMENT