Loading...
HomeMy WebLinkAboutFile Documents.1012 E Cooper Ave.0102-2021-BRES (10) e e rn e n t ENVIRONMENTAL INC 189 County Rd. 135 Glenwood Springs,CO 81601 iosh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report Victorian Condos Date: 05/01/2020 1012 E. Cooper Ave. Unit 5 vi Date: 08/05/2020 Aspen, CO 81611 Date of Inspection: 04/29/2020 Element Environmental Project#: Date of Inspection: 08/04/2020 Crawford 042920 Unit 5 cu E: au Client: a: Crawford Designs Client Job Name Unit 5 Attn: TABLE OF CONTENTS z R Simon Bentley 1.0 - Scope of Work 2.0 - Sampling Requirements 0 3.0 - Sampling Methodology (i) Building Inspector: 4.0 - Laboratory 5.0 - Suspect Materials Sampled Ellen Johnson 6.0 -Table of Results 7.0 - Description of Sampling Area 'iDPHE#23799 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Joshua Johnson ',DPHE#18401 Asbestos Samples Analyzed: 12 Positive Asbestos Samples: 5 'v En nmoi 7/2o/2o21 MO4/12/2022 J RIRCOMMINUNCEIMP ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2-Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(ISO- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below. RECEIVED d T w LI; 21 e e m e n t 38g county rd 135 glenwood span f{lam int,, g7u.z743139 www.elementconsults.com ' Project#-Crawford 042920 Unit 5 ENVIRONMENTAL INC LEAD ASBESTOS H i I SDI 6 MENT 3 5.0- SUSPECT MATERIALS SAMPLES • Texture • Tape • Joint Compound • Tile Grout • Drywall • Shingles 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Light Roll Texture Throughout Surfacing 5 —3689 sq.ft. No.7—Friable ACM with low potential 2%Chrysotile in 3 of 5 Unit 5 for damage Samples (B) Tile Grout in Bath Miscellaneous 2 —100 sq.ft. Non-Friable Non-ACM No Asbestos Detected (C)08/04/20 Light Roll Texture in Attic Surfacing 3 —480 sq.ft. No.7—Friable ACM with low potential 2%Chrysotile in 2 of 3 for damage Samples (D)08/04/20 Shingles in Attic Miscellaneous 2 —200 sq.ft. Non-Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage (TSI)ACM 7-Friable ACM with low potential for damage 2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories 3-Significantly damaged friable Surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • The Light Roll Texture throughout Unit 5 • The Tile Grout in the bathroom • The Light Roll Texture in the Attic 08/04/2020 • The Shingles in the Attic 08/04/2020 RECEIVED 21 e 2 m en 189 county rd 135 glenwood spnnc-�'cObintu. 970.2743139 www.elementconsults.com Project#-Crawford 042920 Unit 5 ENVIRONMENTAL INC LEAD ASBESTOS H i 1' I SDI " MENT 4 8.0- CONCLUSION The areas on the table in Black did not contain asbestos. The areas on the table in Red contained asbestos: • The Light Roll Texture throughout Unit 5 including the attic These materials become friable when they are removed. If these materials are to be disturbed or removed,the materials MUST be remediated in accordance with the CDPHE Regulation No.8 by a licensed abatement contractor. For residential projects over 32 square feet of surfacing material,50 linear feet of pipe insulation, or 55 gallon drum of waste; and for commercial projects with 160 square feet of surfacing material, 260 linear feet of pipe insulation,or a 55 gallon drum of waste,a permit is required.The permit is through the CDPHE.Along with the permit,a final air clearance is required by a certified Air Monitoring Specialist. For projects over 3,000 square feet,a Project Design and Project Manager is required. Element Environmental is certified and can perform Final Clearances, Project Design, and Project Management if required.All work performed MUST follow all EPA,State Regulation 8, and OSHA regulations to protect the general public,the client, and the workers. Sincerely, Ellen Johnson e 4 e m en t 189 county rd 135 gLenwood springs,co 816" 727.274;'3. www.elementconsutts.com 6c� ENVIRONMENTAL INC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAT, S Ru21 R104/12r / ui /2022 KROUGUINUNCEASPEN BUILDING DEPARTMENT 9.0- LAB REPORT ti•• eurofins ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: Crawford 042920 Unit 5, 1012 E. Cooper Unit 5 LAB CODE: A205468 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 05/01/20 TOTAL SAMPLES ANALYZED: 7 #SAMPLES>1% ASBESTOS: 3 e e m en -L 18g county rd 135 glenwood springs,co 816" 7 (.274;'3: EID www.elementconsutts.com ENVIRONMENTAL AC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz s R // ui u21 04/12/2022 " COO `IMP ASPEN BUILDING DEPARTMENT 6 • eurofins Asbestos Report Summary ti By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: Crawford 042920 Unit 5, 1012 E. Cooper LAB CODE: A205468 Unit 5 METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description % J 5 Al Layer 1 A88090 White Light Roll Texture Chrysotile 2% Layer 2 A88090 Gray Sheetrock None Detected 5 A2 Layer 1 A88091 White Light Roll Texture None Detected Layer 2 A88091 Gray Sheetrock None Detected 5 A3 Layer 1 A88092 White Light Roll Texture Chrysotile 2% Layer 2 A88092 Gray Sheetrock None Detected 5 A4 Layer 1 A88093 White Light Roll Texture None Detected Layer 2 A88093 Gray Sheetrock None Detected 5 A5 Layer 1 A88094 White Light Roll Texture Chrysotile 2% Layer 2 A88094 Gray Sheetrock None Detected 5 B1 A88095 White Tile Grout None Detected 5 B2 A88096 Gray Tile Grout None Detected Page 1 of 1 e e m e n - 189 county rd 135 glenwood springs,co 816" _ (.274,'3. E ID www.elementconsults.com ENVIRONMENTAL ANC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAT, S R [:_vI // ui u21 04/12/2022 RECOMMINUNCE lIMP ASPEN BUILDING DEPARTMENT 7 tiff° eurofins ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: A205468 189 CR 135 Date Received: 04-30-20 Glenwood Springs, CO 81601 Date Analyzed: 05-01-20 Date Reported: 05-01-20 Project: Crawford 042920 Unit 5, 1012 E. Cooper Unit 5 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous % 5 Al Light Roll Texture Heterogeneous 75% Calc Carb 2%Chrysotile Layer 1 White 18% Binder A88090 Fibrous 5% Paint Bound Layer 2 Sheetrock Heterogeneous 25% Cellulose 75% Gypsum None Detected A88090 Gray Fibrous Bound 5 A2 Light Roll Texture Heterogeneous 75% Calc Carb None Detected Layer 1 White 20% Binder A88091 Fibrous 5% Paint Bound Layer 2 Sheetrock Heterogeneous 25% Cellulose 75% Gypsum None Detected A88091 Gray Fibrous Bound 5 A3 Light Roll Texture Heterogeneous 75% Calc Carb 2%,Chrysotile Layer 1 White 18% Binder A88092 Fibrous 5% Paint Bound Layer 2 Sheetrock Heterogeneous 25% Cellulose 75% Gypsum None Detected A88092 Gray Fibrous Bound 5 A4 Light Roll Texture Heterogeneous 75% Calc Carb None Detected Layer 1 White 20% Binder A88093 Fibrous 5% Paint Bound Page 1 of 3 e e m en i8g county rd 135 gLenwood springs,co 816" _'c.274,'3. www.elementconsults.com I.•�w ENVIRONMENTAL INC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz s R Nee �1/ ui u21 n104/12/2022 KROUGUINUNCE 11.P ASPEN BUILDING DEPARTMENT 8 tiff° eurofins . ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: A205468 189 CR 135 Date Received: 04-30-20 Glenwood Springs, CO 81601 Date Analyzed: 05-01-20 Date Reported: 05-01-20 Project: Crawford 042920 Unit 5, 1012 E. Cooper Unit 5 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous Layer 2 Sheetrock Heterogeneous 25% Cellulose 75% Gypsum None Detected A88093 Gray Fibrous Bound 5 A5 Light Roll Texture Heterogeneous 75% Calc Carb Layer 1 White 18% Binder A88094 Fibrous 5% Paint Bound Layer 2 Sheetrock Heterogeneous 25% Cellulose 75% Gypsum None Detected A88094 Gray Fibrous Bound 5 B1 Tile Grout Heterogeneous 75% Silicates None Detected A88095 White 25% Binder Non-fibrous Bound 5 B2 Tile Grout Heterogeneous 75% Silicates None Detected A88096 Gray 25% Binder Non-fibrous Bound Page 2 of 3 e e m en 189 county rd 135 gLenwood springs,co 816" _'c.274,'3. www.elementconsutts.com I.•�w ENVIRONMENTAL AC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz / suR 2621 J2 � /2022 °RO°` ASPEN BUILDING DEPARTMENT 9 ti:: eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: APPROVED BY: lG Yvette Nkunde-Bose Tianbao Bai,Ph.D.,CIH Laboratory Director NVIAp TESTING NVLAP LAB CODE 101768-0 Page3of3 e e m en 189 county rd 135 gLenwood springs,co 816" _'c.274,'3. i www.elementconsutts.com I.•�w ENVIRONMENTAL NC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz / suR 2621 J2 � /2022 °RO°` ASPEN BUILDING DEPARTMENT 10 eurofins ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: Crawford 080420 Victorian, 1012 E. Cooper 5 LAB CODE: A209628 TEST METHOD: EPA 600/R93/ 116 and EPA 600/M4-82/020 REPORT DATE: 08/05/20 TOTAL SAMPLES ANALYZED: 5 #SAMPLES>1% ASBESTOS: 2 e e m en t1.8g county rd 135 glenwood springs,co 816" 'c.274,'3! www.elementconsutts.com ED ENVIRONMENTAL INC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAZ s H BZi ,/ ui u21 FORG011hallIFIAIICE 1 IMP ASPEN BUILDING DEPARTMENT 11 Asbestos Report Summary ., . eurofins By: POLARIZING LIGHT MICROSCOPY PROJECT: Crawford 080420 Victorian, 1012 E. LAB CODE: A209628 Cooper 5 METHOD: EPA 600/R93/ 116 and EPA 600/ M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 5-C1 Layer 1 A140185 Beige Light Roll Chrysotile 2% Layer 2 A140185 Brown Sheetrock None Detected 5-C2 Layer 1 A140186 Beige Light Roll Chrysotile 2% Layer 2 A140186 Brown Sheetrock None Detected 5-C3 A140187 White Light Roll None Detected 5-D1 A140188 Brown,Red Shingle None Detected 5-D2 A140189 Brown,Red Shingle None Detected Page 1 of 1 e e m e n - 18g county rd 135 glenwood springs,co 816" _'c.274;'3. E www.elementconsults.com ENVIRONMENTAL NE Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz s R ,:_vl // ui u21 04/12/2022 RECOMMINUNCE lIMP ASPEN BUILDING DEPARTMENT 12 . eurofins • ASBESTOS BULK ANALYSIS ti By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: A209628 189 CR 135 Date Received: 08-05-20 Glenwood Springs, CO 81601 Date Analyzed: 08-05-20 Date Reported: 08-05-20 Project: Crawford 080420 Victorian, 1012 E.Cooper 5 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 5-C1 Light Roll Heterogeneous 63% Binder Layer 1 Beige 35% Calc Carb A140185 Non-fibrous <1% Paint Bound Layer 2 Sheetrock Homogeneous 10% Cellulose 85% Gypsum None Detected A140185 Brown 5% Fiberglass Fibrous Bound 5-C2 Light Roll Heterogeneous 63% Binder 2%Chrysotile Layer 1 Beige 35% Calc Carb A140186 Non-fibrous <1% Paint Bound Layer 2 Sheetrock Homogeneous 10% Cellulose 85% Gypsum None Detected A140186 Brown 5% Fiberglass Fibrous Bound 5-C3 Light Roll Heterogeneous 65% Binder None Detected A140187 White 35% Calc Carb Non-fibrous <1% Paint Bound 5-D1 Shingle Heterogeneous 20% Cellulose 65% Tar None Detected A140188 Brown,Red 15% Gravel Fibrous Bound 5-D2 Shingle Heterogeneous 20% Cellulose 65% Tar None Detected A140189 Brown,Red 15% Gravel Fibrous Bound Page 1 of 2 e e m en t 189 county rd 135 gLenwood springs,co 816" _'(.274;3. www.elementconsults.com ENVIRONMENTAL INC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz a fr �1/ S uR� u 21 M04/12/2022 KROUGUINUNCE 11.P ASPEN BUILDING DEPARTMENT 13 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: APPROVED BY: lGa✓•X't'o G/� - Elisabeth Thinh Tianbao Bai,Ph.D.,CIH Laboratory Director NVIAp TESTING NVLAP LAB CODE 101768-0 Page 2 of 2 e e m en 189 county rd 135 gLenwood springs,co 816" _'c.274,'3. i www.elementconsutts.com I.•�w ENVIRONMENTAL NC Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz / suR u 21 J2 � /2022 °RO°` ASPEN BUILDING DEPARTMENT 14 10.0- CERTIFICATES 4,:, !^+' Pm..s"-.,, *g't>rY- .*`«P'NY'c?i- `�4 s+Hf�•: Y and "Sv ao A / 0 ysf ca s -.,. Colar Department du De Coloradolh m,rnc ofPuhlK Health 1-; .par _ - of Puhbr H.�hh and Fn.imnrncnt : •"0, and I.n ASBESTOS ASBESTOS g CERTIFICATION* CERTIFICATION* This cantle that Thiscmifics lhm �' Joshua Jay Johnson Ellen Johnson : • Cend-It-salend-It-salon No.:I8401 Cerrlrinhoo No.:23'!99 has Itlet the requttemenls of'_5]>0]C R 5 and An(2'aal t Cxntml i h: N requircmrnts of 25]50]C.R.S. J A Q f y C naul (-} Commission Regulation No a,Pan B.and-s hembl ce'fled Sn the ( son Regulution No 9.P B d-h by -rcd by the stele nt'Cnlorada m the following disc Aline " .mtc of C'olonodo m the following dice pl'ne. Building Inspector* It- -;-:' Building Inspector* ,k .,i_ t...n- .1.aa,2021 I.sue0: July31,2019 ,' t;apim: Jel�14,21n1 F.iPlrta' Auav9101,2030 '2' :._• I w aw,ma a - .CI�Ll .worm.a2 «.uwr+ ,. .i 4 �_j1. .s area f :.,t ff>a.+a,,,,,w: .','aaa�,,w,4s..car...c;1-;,,,,4...r,,q: C I If 09' ri1 Colorado Department -.. of Public Health and Environment ASBESTOS CONSULTING FIRM This certifies that Element Environmental LLC • Registration No.:ACF-21640 ' has met the registration requirements of 25-7.507,C.R.S.and the Air Quality Control Commission Regulation No.8,Part B,and is hereby authorized to perform asbestos consulting activities as required under Regulation No 8,Part B,in the state of Colorado. ..4 Issued: January 09,2020 \yI l - Expires: January25,2021 — _- J Aulasn.d Ana ne neevuw Boat e e m en t1.8g county rd 135 glenwood springs,co 816" _ c.274,'3EID www.elementconsults.com ENVIRONMENTAL isi. Project#-Crawford 042920 Unit 5 LEAD ASBESTOS HAz S R I:_v, // � �21 04/12/2022 .aR ASPEN BUILDING DEPARTMENT