HomeMy WebLinkAboutFile Documents.715 W North St.0103-2023-BROF (7)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
10/03/2023
linzhid
0103-2023-BROF
618 SMUGGLER LLC
715 W NORTH ST
273512117002
Extent of Work
Hardscape Areas
Landscape Areas
Existing Downspout location (to remain)
Snow Guards
Existing Gutter locations (to remain)
Heat Tape (on roof and in all gutters/DS)
Dumpster & Toilet locations
715 W North Street
Site Plan
09/07/2023
Snow stops required at all locations
where roofs could shed snow onto
walkways, stairs, alleys, decks, exits,
utilities and meters, emergency escape
and rescue opening window wells, or
adjacent properties - Ordinance 1,
2023.
HEAT TAPE MANDATORY CONTROL REQ’S.
All heat tape systems shall meet the following per (Ordinance 1 Series 2023):
-Automatic controls configured for system shut off when air temperature is above
40°F and comply with one of the following:
-shut off in absence of moisture
-shut off at night (daylight sensor or timer)
Standing Seam Panels
Standing Seam Roofing
715 W North St Roof Replacement
GAF Versashield for Class A Fire Rating
PSU30 High Temp Ice & Water Shield
24 ga. pre-finished flashing
Existing
Plywood & Fascia
Phone: 609-330-5045
Email: phil@stormkingroof.com
www.stormkngroof.com 09/07/2023
ESR-2053 | Most Widely Accepted and Trusted Page 3 of 4
TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING
VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION
ROOF COVERING2 SUBSTRATE UNDERLAYMENT1 ROOF
CLASSIFICATION
MAXIMUM
SLOPE
Class A asphalt glass fiber shingle 15/32-inch plywood One layer VersaShield® A Unlimited
Stone coated, steel, direct to deck,
0.013-inch thickness (0.330 mm),
shingles or panels
15/32-inch plywood or
spaced sheathing One layer VersaShield® A Unlimited
Steel direct to deck, 0.013-inch
thickness (0.330 mm), shingles or
panels
15/32-inch plywood or
spaced sheathing
One layer VersaShield®,
and one layer Type 30
asphalt saturated organic
felt
A Unlimited
15/32-inch plywood or
spaced sheathing One layer VersaShield® B Unlimited
Steel over battens, 0.013-inch
thickness (0.330 mm), shingles or
panels
15/32-inch plywood or
spaced sheathing One layer VersaShield® A Unlimited
Existing wood shakes or
shingles installed over
spaced or solid sheathing
Two layers VersaShield® A Unlimited
Existing wood shakes or
shingles installed over
spaced or solid sheathing
One layer VersaShield® B Unlimited
Steel, 0.016-inch thickness (0.406
mm), panels or standing seam
system
15/32-inch plywood or
spaced sheathing One layer VersaShield® A Unlimited
Copper, 0.016-inch thickness (0.406
mm), shingles or panels
15/32-inch plywood or
spaced sheathing
One layer VersaShield®,
and one layer Type 30
asphalt saturated organic
felt
A Unlimited
Existing wood shakes or
shingles installed over
spaced or solid sheathing
Two layers of VersaShield® A Unlimited
15/32-inch plywood or
spaced sheathing One layer VersaShield® B Unlimited
Existing wood shakes or
shingles installed over
spaced or solid sheathing
One layer of VersaShield® B Unlimited
Aluminum, 0.018-inch (0.457 mm),
shingles, panels, or standing seam
system
15/32-inch plywood or
spaced sheathing Two layers VersaShield® A Unlimited
15/32-inch plywood or
spaced sheathing One layer VersaShield® B Unlimited
Existing wood shakes or
shingles installed over
spaced or solid sheathing
One layer VersaShield® B Unlimited
TPO, CSM, CPA, EPDM, cap sheet,
or modified bitumen single-ply
membranes
15/32-inch plywood Two layers VersaShield® A 11/2:12
15/32-inch plywood,
insulation Two layers VersaShield® A 11/2:12
15/32-inch plywood One layer VersaShield® B 11/2:12
PVC single-ply membrane
15/32-inch plywood Two layers VersaShield® A 2:12
15/32-inch plywood,
insulation Two layers VersaShield® A 11/2:12
15/32-inch plywood One layer VersaShield® B 11/2:12
For SI: 1 inch = 25.4 mm.
1Underlayment must be installed in accordance with Section 4.0 of this report.
2Roof coverings must be recognized in a current ICC-ES evaluation report. The roof covering must comply with the Class A or B flame-spread
requirements of UL790 (ASTM E108), as applicable to the systems defined in this table.
09/07/2023
Amenity Energy Use Approved (2021 CODE)
RREMP CREMP
PERMIT #:0103-2023-BROF DATE:10/3/2023
HEAT TAPE TOTAL WATTAGE:___3000______
WATTS/FT:__________6___________________
TOTAL LINEAR FT:______500_______________
OFFSET: ____REMP PAYMENT______________
*Note:
- The first 1000W are exempt from REMP.
- All roof permits will require a sub-electrical
permit applied for by a licensed electrician.
- A sub-electrical permit must be applied for
prior to the final roof inspection as both final
inspections will occur simultaneously.
X
Sub electrical permit needed for heat tape connections and
controls - must be applied for by a licensed electrician