HomeMy WebLinkAboutFile Documents.1405 Red Butte Dr.0088-2022-BCHO (6)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 12/14/2022 kylas May 16, 2022 Bryan May Architecture 501 Rio Grande Pl Suite 109 Aspen, CO 81611 Attn: Bryan May RE:Structural Remodel 1405 Red Butte Dr, Aspen, CO, 81611 Bryan, We have reviewed the Permit Drawings for the remodel at 1405 Red Butte Drive provided by your office, dated December 17, 2021. The drawings show a single family residence, two stories tall, and approximately 2,000 square feet in size. We understand that as a part of the remodel, the window openings are being modified to accommodate the proposed layout. Prior to removal or demolition of any framing members, wall and ceiling finishes shall be partially removed to allow observation of the structural system. Once the structure is visible, we shall be contacted to perform a structural observation of the exposed structure in order to determine the structural implications of the proposed modifications. Demolition or removal of any framing members shall not proceed until this visit is completed. If structural reinforcement, strengthening, or modifications are necessary, we can provide sealed structural plans and details as required. We appreciate the opportunity to work with you and your team again. If you have further questions or concerns, please feel free to reach out. We look forward to the project. Sincerely, Tim Strickland, P.E. Principal 2225 E. MURRAY HOLLADAY RD., SUITE 110 ::SALT LAKE CITY, UTAH 84117 ::801.274.3950 ::structuralds.com May 13, 2022 11/29/2022 OBSERVATION REPORT Project Name:1405 Red Butte Drive Report #:01 Date:July 13, 2022 Site Time:10:30 AM Weather:Sunny Temperature:45 F Observed By:Tim Strickland, PE Accompanied:Nikolai Valdmanis, Don Stuber, Tarryn Link No items listed herein shall be interpreted as inspections or warranties of any kind. All items noted need to be verified, checked, and addressed by the project superintendent or project manager. 1.We visited the site on the morning of July 13 to observe the existing framing in order to understand the existing load path in order to design headers for the revised windows associated with the remodel. Prior to our visit, the interior finishes had been removed up to the ceiling of the second level. The state of the structure at the time of our visit is shown in Image 1 on the following page. 2.The following items were observed during this site visit: 2.1.The floor joists below the original second floor restroom had been significantly compromised. We noted one joist with no end support. Two remediation options are available, depending on whether the existing floor penetration is required to remain: ●If the penetration is to remain, provide a full depth 2x header to support the unsupported end of the existing joist shown in Image 2. The joist end and both ends of the header shall be supported by Simpson LUS210 joist hangers. Sister one additional 2x10 to each of the adjacent joists receiving the joist header. ●If the penetration is to be abandoned, sister a full length 2x10 to the existing joist, ensuring that both ends of the new joist are fully supported by the 2x4 wall at each end. See Image 2 - Action Required:YES 2.2.The floor joists below the original second floor restroom had been significantly compromised. We noted one joist that appeared to have been spliced, but the splice is inadequate for the loads imposed. Provide a new full length 2x10 joist to the existing joist, ensuring that both ends of the new joist are fully supported by the 2x4 wall at each end. See Image 3 - Action Required:YES 2.3.We observed the existing framing and have provided a header schedule for use by the contractor when enlarging existing openings to match the dimensions provided in the architectural drawings. Refer to attached schedule SDS-1 Action Required: NO 2225 E. MURRAY HOLLADAY RD., SUITE 110 ::SALT LAKE CITY, UTAH 84117 ::801.274.3950 ::structuralds.com 11/29/2022 OBSERVATION PHOTOGRAPHS IMAGE 1 - State of the structure during our 7/13 visit. Interior finishes removed and structure exposed IMAGE 2 - Unsupported floor joist. Refer to Item 2.1 for repair options 2225 E. MURRAY HOLLADAY RD., SUITE 110 ::SALT LAKE CITY, UTAH 84117 ::801.274.3950 ::structuralds.com 11/29/2022 IMAGE 3 - Insufficient joist splice. Sister new joist at this location per Item 2.2 IMAGE 4 - Overview of compromised floor framing below Level 2 bathroom. Items 2.1 and 2.2 are visible. 2225 E. MURRAY HOLLADAY RD., SUITE 110 ::SALT LAKE CITY, UTAH 84117 ::801.274.3950 ::structuralds.com 11/29/2022 OPEN OPEN WOOD HEADER CONC FND BELOW WOOD WALL GROUND LEVEL FLOOR / ROOF LEVEL WOOD HEADER NOTES: 1. SEE WOOD HEADER SCHEDULE FOR HEADER SIZE, AND NUMBER OF KING + TRIM STUDS. TYPICAL WOOD WALL ELEVATION DOUBLE 2X STUD AT END OF WALL MIN, TYP UNO STUD BLOCKING SILL ANCHOR PER SCHEDULE TOP PLATE KING STUDS TRIMMERS MAX SPAN MAX SPAN WALL BLOCKING THIRD-HT WALL BLOCKING MID-HT STUD SPACING SILL PLATE WOOD HEADER SCHEDULE MARK COMMENTSKING STUDSHEADERMAX SPAN NOTES: 1. SEE GENERAL STRUCTURAL NOTES FOR ALL OTHER REQUIREMENTS. 2. HDR 3 IS ONLY TO BE USED AT FULL HEIGHT WINDOW AT MAIN ENTRY AT BASE OF STAIRS AND IS NOT TO BE USED FOR ANY OTHER WINDOW OR DOOR OPENING. TRIM STUDS HDR-1 (2) 2x8 No. 1 3'-0" (2) 2x4 No. 1 (1) 2x4 HDR-2 (2) 11.7/8" LVL 6'-0" (4) 2x4 No. 1 (1) 2x4 HDR-3 (4) 2x8 No. 1 6'-6" (3) 2x8 No. 1 (1) 2x8 WALL STUDS TO BE 2x8. PROVIDE 5/8" DIA. X 6" TITEN HD ANCHORS AT 24" O.C. Scale: AS INDICATED Project No.: Date Status 2225 E. MURRAY HOLLADAY RD., SUITE 110 SALT LAKE CITY, UTAH 84117 801.274.3950 structuralds.com Supplemental Structural Sketch SHEET: SDS-1 1405 Red Butte HEADER SCHEDULE 22034 07/20/2022 CD July 20, 2022 11/29/2022 0088-2022-BCHO BORTZ NEIL K GRANTOR TRUST #2 1405 RED BUTTE DR 273501302010 1 MASTER PERMIT 0019-2022-BRES APPLICATION ACCEPTED DATE: 2022-11-29 PERMIT NUMBER: 0088-2022-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 1405 RED BUTTE DR UNIT: PARCEL ID: 273501302010 LEGAL DESCRIPTION: RED BUTTE OWNER: BORTZ NEIL K GRANTOR TRUST #2 PERMIT CONTRACTOR: RUTGERS CONSTRUCTION INC DESCRIPTION OF WORK Structural repair of existing deck to replace rotted joists. Includes an expansion of the deck. Revise two windows. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? No CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE (IRC) One family REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE OCCUPANCY GROUP (IBC) R-3 WORK CHANGES BUILDING FOOTPRINT? Yes CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? No 02/13/2023 justinh