Loading...
HomeMy WebLinkAboutFile Documents.1405 Red Butte Dr.0067-2023-BCHO (7)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. A4.01 2 A4.01 3 A4.01 11 A5.02 1 A5.021 1 2 2 A A B B 1 A5.04 1 A5.04 1 A5.03 1 A5.03 1 A5.01 1 A5.01 3 3 4 4 C C 5 5 D D 4" / 1 ' - 0 " 4" / 1 ' - 0 " EXISTING CHIMNEY NEW STANDING SEAM METAL ROOF 6 6 E E 5 SNOW GUARDS SNOW GUARDS SCALE:A2.23 1/4" = 1'-0" 1 PROPOSED - ROOF PLAN NOTE: INSTALL SNOW GUARDS ABOVE ALL REQUIRED LOCATIONS: PARKING, UTILITY METERS,WALKWAYS, AND OTHER POTENTIALLY OCCUPIED AREAS STANDING SEAM METAL ROOFING FIBERGLASS-REINFORCED CLASS 'A' UNDERLAYMENT, VERSASHIELD OR SIM HIGH TEMP ICE AND WATER UNDERLAYMENT, WIP 300 HT OR SIM EXISTING SHEATHING TO REMAIN EXISTING FRAMING AND INSULATION TO REMAIN EXTERIOR ATTIC ALL LAYERS TO BE INSTALLED PER MANUFACTURER RECOMMENDATIONS AND ESR REPORT REQUIRMENTS Autodesk Docs://1405 Red Butte/2126_1405 Red Butte_Phase 1.rvtM SCALE:A2.23 1 1/2" = 1'-0" R1 ROOF ASSEMBLY NOTE: EXISTING ROOF FRAMING CANNOT SUPPORT ADDITIONAL SNOW LOADING THAT WOULD RESULT FROM THE ADDITION OF NEW INSULATION Snow stops required at all locations where roofs could shed snow onto walkways, stairs, alleys, decks, exits, utilities and meters, emergency escape and rescue opening window wells, or adjacent properties - IBC 1513/COA 8.20.020(z). Heat trace/tape must be self-regulating type cable and must include automatic controls and timer capable of turning off the system when the outdoor temperature is above 50 degrees and during daylight hours. luisp 08/02/2023ZONING SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S All snowmelt systems shall meet the following: - Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. - R10 insulation shall be installed under the area to be snowmelted or R5 insulation shall be installed under the slab edges. (Ordinance 11 Series 2011) - Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2015 IECC R403.9 and C403.2.4.5) - Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2015 IECC R403.9 and C403.2.3.5) - Inspection by testing hydrostatically at 1.5 times max system design pressure, but not less than 100psi, for 15 minutes. (2015 IMC 1208.1) 08/04/2023 linzhid 0067-2023-BCHO BORTZ NEIL K GRANTOR TRUST #2 1405 RED BUTTE DR 273501302010 Master permit under 2015 code, so change order will fall under 2015, as well. No sub-electrical permit or REMP required External Energy Use Approved RREMP CREMP PERMIT #:0067-2023-BCHO DATE:_8/9/23_ SNOWMELT:________141.7 sq ft___________ POOL: _________N/A_________________ SPA: ________N/A__________________ OFFSET:_________0.74 kW_______________ REMP SHEET: ______N/A________________ REVIEWED BY: ____LD__________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: ____95%________ X