HomeMy WebLinkAboutFile Documents.315 E Dean St.0004-2022-TSTR (4)10/28/2020 Reviewed by Fire Jan.Legersky 10/30/2020 1'-7"Typ. 36" accessible route typ. Existing fire pit shall shut off while tent is in place All electrical light or heat to be on a programmable timer to ensure it is not left on outside of operating hours. Propane heaters may be used outside of enclosures as long as the heater has a 5' horizontal clearance to combustible materials and is not under any overhang. Typ. 30"x48" approach clearance for accessible seating A minimum of 5% of seating is required to be accessible, on an accessible route, and distributed evenly throughout the space. Table height at accessible seating shall be 28"-34" in height to comply. 44" wide minimum exit egress path to be clear and maintained to existing building exits at all times. Directional exit signage to be in place for inspection. 11/02/2020 justinh