Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.621 W Francis St.0008-2021-BRES (14)
aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 fax: 970-748-8521 email: stan@aec-vail.com web: www.aec-vail.com Shuford Residence Permit Comment Response To: Will Otte From: AEC Company: R+B Project: Shuford Residence Phone: 970-544-9006 Project No.: 20075 Date: 05/24/21 Re: Permit Comment Response Mechanical Comments 90. Mechanical Plans See attached cutsheet. HP-3A is 24-13/16” tall and will be mounted on a 4” equipment pad. Total unit height is less than 30”. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit TPVA0A0121AA70A Outdoor Unit Standard Model TRUZA0121KA70NA Seacoast Model TRUYA0121KA70BA INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 1.0% at 1.0 in.WG • Unique blow through design allows simple coil cleaning when the blower is removed • Multi-position installation: horizontal (left or right), vertical (up or down). For downflow configurations, the CMA-1 is recommended for proper management of condensate to prevent water blow-off in certain conditions • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control • Multiple control options available: ○kumo cloud® smart device app for remote access ○Third-party interface options ○Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Power receiver pre-charged with refrigerant volume for piping length up to 70 ft • Low ambient cooling down to -40°F providing 100% capacity (only for TRUY models with wind baffles installed) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers • Superior energy and operational efficiency TPVA0A0121AA70A & TRUZA0121KA70(N/B)A12 ,000 BTU/H MULTI-POSITION AIR HANDLER12,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR CUT SHEET FOR HP-3A Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: TPVA0A0121AA70A & TRUZA0121KA70(N/B)A test Cooling at 95°F1 Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 4,800 Maximum Power Input W 890 Rated Power Input W 890 Moisture Removal Pints/h 1.2 Sensible Heat Factor 0.77 Power Factor %87.9/87.9 Heating at 47°F2 Maximum Capacity BTU/H 19,000 Rated Capacity BTU/H 14,000 Minimum Capacity BTU/H 5,700 Maximum Power Input W 1,730 Rated Power Input W 1,070 Power Factor %96.4/96.4 Heating at 17°F3 Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,900 Maximum Power Input W 1,440 Rated Power Input W 1,400 Heating at 5°F4 Maximum Capacity BTU/H 12,100 Maximum Power Input W 2,000 Efficiency SEER 21.4 EER1 13.4 HSPF [IV]10.3 COP at 47°F2 3.82 COP at 17°F at Maximum Capacity3 2.45 COP at 5°F at Maximum Capacity4 1.77 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR]kA 5 Recommended Fuse/Breaker Size (Oudoor)A 15 Recommended Wire Size [Indoor - Outdoor]AWG 14 Indoor Unit MCA A 3.0 Fan Motor Full Load Amperage A 2.4 Fan Motor Output W 121 Airflow Rate at Cooling, Dry CFM 280–340–400 Airflow Rate at Heating, Dry CFM 280–340–400 Sound Pressure Level [Cooling]dB[A]27–31–35 Sound Pressure Level [Heating]dB[A]27–31–35 External Static Pressure in.WG 0.30–0.5–0.8 Drain Pipe Size In. [mm]3/4 FPT [19.05] Coating on Heat Exchanger — External Finish Color Galvanized steel cabinet-Powder coated Slate Gray Unit Dimensions W x D x H: In. [mm]17 x 21-5/8 x 50-1/4 [432 x 548 x 1275] Package Dimensions W x D x H: In. [mm]13-7/16 x 34-11/16 x 45-5/16 [340 x 880 x 1,150] Unit Weight Lbs. [kg]92 [41] Package Weight Lbs. [kg]104 [47] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]*°F 95 DB, 71 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum]°F 80 DB / 70 DB NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. »Wind baffles required to operate below 23°F DB in cooling mode. »Cooling-only system with wind baffle: -40°F - 115°F. »Heat pump system with wind baffle: 0°F - 115°F. »Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (TRU*A0*******BA MODELS) • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. SPECIFICATIONS: TPVA0A0121AA70A & TRUZA0121KA70(N/B)A test Outdoor Unit MCA A 11.0 MOCP A 28 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 46 Airflow Rate CFM 1590/1590 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling1 dB(A)44 Sound Pressure Level, Heating2 dB(A)46 Compressor Type INVERTER-driven twin rotary Compressor Model SNB092FNCM Compressor Rated Load Amps A 7.0 Compressor Locked Rotor Amps A 12.0 Compressor Oil Type // Charge oz.FV50S // 12 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater N/A Unit Dimensions W x D x H: In. [mm]31-13/16 (+7/16) x 11-3/16 x 24-13/16 [809 (+62) x 300 x 630] Package Dimensions W x D x H: In. [mm]37-1/16 x 16-3/16 x 27-7/16 [941 x 411 x 670] Unit Weight Lbs. [kg]93 [42] Package Weight Lbs. [kg]104 [47] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]*°F 115 DB / 0 DB Heating Air Temp [Maximum / Minimum]°F 70 DB, 59 WB / 12 DB, 10 WB Heating Thermal Lock-out / Re-start Temperatures**°F 8.0 / 12 Refrigerant Type R410A Charge Lbs, oz 4, 7.0 Chargeless Piping Length Ft. [m]70.0 [20.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m]0.2 [15] Piping Gas Pipe Size O.D. [Flared]In.[mm]1/2 [12.7] Liquid Pipe Size O.D. [Flared]In.[mm]1/4 [6.35] Maximum Piping Length Ft. [m]100 [30] Maximum Height Difference Ft. [m]100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. »Wind baffles required to operate below 23°F DB in cooling mode. »Cooling-only system with wind baffle: -40°F - 115°F. »Heat pump system with wind baffle: 0°F - 115°F. »Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (TRU*A0*******BA MODELS) • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: TPVA0A0121AA70A Control Interface 3-Pin Connector PAC-715AD BACnet® and Modbus Interface PAC-UKPRC001-CN-1 CN24 Relay Kit CN24RELAY-KIT-CM3 Connector cable for remote display PAC-SA88HA-EP IT Extender PAC-WHS01IE-E kumo station® for kumo cloud® TAC-WHS01HC-E Lockdown bracket for remote controller RCMKP1CB Remote Operation Adapter‡ PAC-SF40RM-E Thermostat Interface PAC-US444CN-1 USNAP Adapter PAC-WHS01UP-E Remote Sensor Flush Mount Temperature Sensor PAC-USSEN001-FM-1 Remote Temperature Sensor PAC-SE41TS-E Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1 Wired Remote Controller Airzone ZBS Wired Blueface Principal Controller White AZZBSBLUEFACECB Airzone ZBS Wired Lite Controller White AZZBSLITECB Airzone ZBS Wired Think Controller White AZZBSTHINKCB Airzone ZBS Wireless Lite Controller White AZZBSLITERB Airzone ZBS Wireless Think Controller White AZZBSTHINKRB Deluxe Wired MA Remote Controller† TAR-40MAAU Simple MA Remote Controller† TAC-YT53CRAU-J Touch MA Controller† TAR-CT01MAU-SB Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller MHK2 Wireless MA Receiver PAR-SR32MA-E Wireless MA Remote Controller TAR-FL32MA-E Wireless Remote Contoller PAR-SL100A-E Condensate Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 Control Wire 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel CW2042S2-100 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel CW2042S2-500 Disconnect Switch (30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 (30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W Downflow Kit Condensate Management Kit for downflow installation CMA-1 Electric Heat Lockout Electric Heat Lockout ETC-211000-MIT Electric Kit Heats 3kW Electric Heater EH03-MPA-SB 5kW Electric Heater EH05-MPA-SB Lineset 100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-100 15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-15 30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-30 50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-50 65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube Insulation) MLS141212T-65 Terminal Block Separate Terminal Power Block SPTB1 NOTES: ‡PAC-SF40RM-E (Unable to use with wireless remote controller) • Ceiling Cassette, Ceiling Suspended, Horizontal-ducted and Multi-position Air Handler Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT ACCESSORIES: TRUZA0121KA70(N/B)A Air Outlet Guide Air Outlet Guide PAC-ADG007AA-E Centralized Drain Pan Centralized Drain Pan PAC-SG63DP-E Control/Service Tool Control/Service Tool PAC-SK52ST M- & P-Series Maintenance Tool Cable Set M21EC0397 USB/UART Conversion Cable (Required for all laptop connection) M21EC1397 Drain Socket Drain Socket PAC-SJ08DS-E Hail Guards Hail Guard HG-A5 M-NET Converter M-NET Converter PAC-SJ96MA-E Mini-Split Wire 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 Mounting Pad Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 Stand 18” Single Fan Stand QSMS1801M 24” Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket -Stainless Steel Finish QSWBSS Outdoor Unit Stand — 12” High QSMS1201M Wind Baffle Front Wind Baffle WB-PA4 Rear Wind Baffle WB-RE4 Side Advanced Wind Baffle WB-SD4 Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Model Nominal Filter si ze Duct Connection PV A-A30AA4 508X508X25.4 477X402 J 77.8(3-1/8) 66(2-5/8) 36.8(1-1/2) 43(1-3/4)8(3/8) 92(3-5/8)30(1-3/16) 43(1-3/4)8(3/8) 55(2-3/16) 548(21-5/8) 117.4 (4-5/8)402(15-7/8) B(Duct)28.8(1-3/16) 76(3)C A D 52 5 . 5 ( 2 0 - 3 / 4 ) 50 . 8 ( 2 ) 47 0 ( 1 8 - 9 / 1 6 ) H 55 ( 2 - 3 / 1 6 ) G 70 ( 2 - 1 3 / 1 6 ) 8( 3 / 8 ) F 55 ( 2 - 3 / 1 6 ) E 24 ( 1 5 / 1 6 ) 13 . 2 ( 9 / 1 6 ) Control bo x Air lte r Air outle t Air inle t (Duct) Ref rigerant pipingbrazing connection(gas) Ref rigerant pipingbrazing connection(liquid) Pr imary drain pipe(Gra vity drain)ø19.05(3/4) 3/4"FPT Secondary drain pipe(Emergency draining)ø19.05(3/4) 3/4"FPT Pr imar y drain pipe(Gra vity drain)ø19.05(3/4) 3/4"FPT (Horizontal left) (Horizontal Right) Secondar y drain pipe(Emergency draining) ø19.05(3/4) 3/4"FPT Pr imar y drain pipe(Gravity drain)ø19.05(3/4) 3/4"FPT Secondar y drain pipe(Emergency draining)ø19.05(3/4) 3/4"FPT Te rminal block(Indoor / Outdoor unit connection) Te rminal block(Remote controller transmission) 2-ø4.6 Burring Holesfor electr ic heat installation ø26 Kno ck out Hole(Remote controller transmission)ø26 Kno ck out Hol e ø26 Kno ck out Hol e ø26 Kno ck out Hole (Indoor / Outdoor unit connection) (Indoor /Outdoor unit connection) (Remote controller transmission) Note 1.Keep the ser vice space for maintenance at the front . Unit:mm(in.) To p To pview Front Bottom Bottomview view Left sideview Right sideview 3 3 2 1 Model Nominal Filter Size Duct Connection 12 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8)18 24 508 x 508 x 25.4 (20 x 20 x 1) 477 x 402 (18-13/16 x 15-7/8)30 36 508 x 609.6 x 25.4 (20 x 24 x 1) 579 x 402 (22-13/16 x 15-7/8)42 Unit: mm (in.) ModelA BCDEFGHJGas Pipe Liquid Pipe 12 432 (17)376 (14-13/16)281 (11-1/8)224 (8-7/8)1275 (50-1/4)680 (26-13/16)823 (32-7/16)735.5 (29)360 (14-3/16)18 24 534 (21)477 (18-13/16)382.6 (15-1/8)266.5 (10-1/2)1378 (54-1/4)737 (29-1/16)953.5 (37-9/16)792 (31-3/16)461 (18-3/16)30 36 635 (25)579 (22-13/16)484.6 (19-1/8)317.5 (12-1/2)1511 (59-1/2)798.5 (31-7/16)1053 (41-1/2)853.5 (33-5/8)563 (22-3/16)42 Ref rigerant pipingare connection(gas) oaaao 1 Ref rigerant pipingare connection(l iquid)2 INDOOR UNIT DIMENSIONS: TPVA0A0121AA70A FORM# TPVA0A0121AA70A & TRUZA0121KA70(N/B)A - 202103 Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: mm<in> Air discharge Air intake Air intake oval hole2-10×21 drain holeø42 2-U Shaped notched holes (Foundation Bolt M10<W 3/8>) (Foundation Bolt M10<W 3/8>) 33 0 <1 3 > 30 0 < 11 -1 3 / 1 6 > 40 <1-19/32> 404.5<15-15/16> 48 <1 - 2 9 / 3 2 > 36 0 < 1 4 - 3 / 1 6 > 32 . 5< 1- 9 / 3 2 > 500<19-11/16> Min.500mm<19-11/16>Min.100mm <3-15/16> Service port FLAREɹ 12.7 (1/2F)Connection forgas pipe FLAREɹø ø 6.35 (1/4F)Connection forliquid pipe Service panelfor charge plug Service panel Earth terminal Te rminal connectionLeft ... Power supply wiringRight ... Indoor/Outdoor wiring 23.2<15/16> 99 . 5 < 3 - 1 5 / 1 6 > 16 4 . 5< 6- 1 / 2 > 49 2 <1 9 - 3 / 8 > 185.5<7-5/16> 4 3 ° 3 5 ° 2-ø 22.2<7/8> 1/2 conduit hole Installation bolt pitch Handle for moving 22 <7/8> 32 0 <1 2 - 5 / 8 > 809 <31-7/8>62 <2-15/32> 154.5 <6-3/32> 310<12-7/32> 8. 5< 11 /3 2 > 22.3<29/32> 63 0 <2 4 - 1 3 / 1 6 > Min.100mm<3-15/16> Ba s i c a l l y o p e n Min.350mm <13-25/32> Ma x . <Foundation bolt height> 18 mm < 2 3 / 3 2 > Free space around the outdoor unit(basic example) 100mm<3-15/16> or more as long asno obstacle is placed on therear and right-and-left sidesof the unit 2 sides should be open in the right, left and rear side. Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts, washers and nut must be purchased locally). FOUNDAT ION BOLT S Piping and wiring connection can be made from the rear direction only. PIPING-WIRING DIRECTION FOUNDAT ION OUTDOOR UNIT DIMENSIONS: TRUZA0121KA70(N/B)A